Electrical Piping Both Surface And Conduit by topsy23: 2:33pm On Sep 14, 2020
Am creating this thread to show case our conduit and surface system of piping.

Feel free to comment ask question, Below are some steps for surface slab piping

Laying of Lighting Pipes around a Beam
• Use of blue line to determine the route up to the edge of the beam
• Vertically place a plumb to transfer the line to the base of the beam
• Horizontally place the plumb at the base of the beam to transfer the line to the other side of the beam
• Then vertically place a plumb at the other side to transfer the line to the base of the beam.
• Blue line is use to transfer the line to other lighting point locations on a straight line
• Transfer the measurements to the pipes
• The vertical length of the beam gives the bending radius of the pipes
• Use the bending spring to achieve the bending radius
• Fixing of the bent pipes around the beam
• The pipes are linked together with couplers
• Adaptable boxes to be used where many pipes are crossing each other
• Linking of pipes to distribution boards.


Contact us today for your Electrical Mechanical Design and Installation

Check out our thread

Distribution boards
https://www.nairaland.com/2668061/abb-distibution-board-schneider-distribution/6

MEP installation
https://www.nairaland.com/1233943/contact-us-electrical-mechanical-plumbing/25

Cables
https://www.nairaland.com/2326721/nigerchin-kabelmetal-coleman-cables/23

1 Like

Re: Electrical Piping Both Surface And Conduit by topsy23: 2:52pm On Sep 14, 2020
More pictures

1 Like

Re: Electrical Piping Both Surface And Conduit by topsy23: 3:53pm On Oct 07, 2020
We are second to none when it comes to neat and well arranged pipe installation

2 Likes

Re: Electrical Piping Both Surface And Conduit by topsy23: 8:21pm On Nov 22, 2020
You will only get the best from us

1 Like

Re: Electrical Piping Both Surface And Conduit by topsy23: 6:13pm On Dec 10, 2020
Thanks for your calls
Re: Electrical Piping Both Surface And Conduit by topsy23: 1:07pm On Jan 17, 2021
Our conduit and surface pipe work is second to none

Re: Electrical Piping Both Surface And Conduit by topsy23: 3:59pm On Mar 28, 2021
Happy Sunday to you all
Re: Electrical Piping Both Surface And Conduit by topsy23: 9:48am On May 10, 2021
Happy.new week ahead
Re: Electrical Piping Both Surface And Conduit by topsy23: 10:55pm On May 16, 2021
Call us today for your surface piping
Re: Electrical Piping Both Surface And Conduit by EgunMogaji2: 10:16am On Jul 15, 2021
topsy23:
We are second to none when it comes to neat and well arranged pipe installation

I believe this.
Re: Electrical Piping Both Surface And Conduit by topsy23: 8:18pm On Jul 20, 2021
Happy Eid-Mubarak to all our esteemed Muslim clients
Re: Electrical Piping Both Surface And Conduit by Enyinne(f): 11:57am On Jul 22, 2021
Happy Sallah ,
I need help . For a 3bedroom flat ,1 tv , 3 Ac ,2 water heater ,fan and fridge. Please what is the quantity of wire I should be expecting to buy .

Thanks Oga mi
topsy23:
Happy Eid-Mubarak to all our esteemed Muslim clients
Re: Electrical Piping Both Surface And Conduit by topsy23: 1:39pm On Jul 22, 2021
Enyinne:
Happy Sallah ,
I need help . For a 3bedroom flat ,1 tv , 3 Ac ,2 water heater ,fan and fridge. Please what is the quantity of wire I should be expecting to buy .

Thanks Oga mi

Below is the quantity of cables needed

1.5mm for lighting, ceiling fan, extractor fan
Red. 4
Black 3
Green 2

2.5mm for socket
Red 2
Black 2
1.5mm green 2

4mm for AC and water heater
Red. 2
Black 2
2.5mm green 2

10mm
Red 1
Black 20m

1 Like

Re: Electrical Piping Both Surface And Conduit by Enyinne(f): 2:25pm On Jul 22, 2021
Thank u sir
topsy23:


Below is the quantity of cables needed

1.5mm for lighting, ceiling fan, extractor fan
Red. 4
Black 3
Green 2

2.5mm for socket
Red 2
Black 2
1.5mm green 2

4mm for AC and water heater
Red. 2
Black 2
2.5mm green 2

10mm
Red 1
Black 20m

Re: Electrical Piping Both Surface And Conduit by topsy23: 2:31pm On Jul 22, 2021
Enyinne:
Thank u sir

You are welcome
Re: Electrical Piping Both Surface And Conduit by topsy23: 2:10pm On Jul 24, 2021
Happy weekend
Re: Electrical Piping Both Surface And Conduit by Enyinne(f): 2:04pm On Jul 25, 2021
Sir , if i hv plan to have solar power in the house ,what should i add more to take it into consideration . Hope to hear from u .thanks
topsy23:


You are welcome
Re: Electrical Piping Both Surface And Conduit by topsy23: 3:05pm On Jul 25, 2021
Enyinne:
Sir , if i hv plan to have solar power in the house ,what should i add more to take it into consideration . Hope to hear from u .thanks

That means you need to add additional small single phase distribution board like or 6ways

So that 80or 90% of light will be in solar and some selected socket .

1.5mm for lighting, ceiling fan, extractor fan + external light
Red. 5
Black 4
Green 2

2.5mm for socket
Red 2
Black 2
1.5mm green 2

4mm for AC and water heater
Red. 2
Black 2
2.5mm green 2

10mm
Red 1
Black 20m

6mm 3-core for inverter 30m

And let your electrician provide a by-pass for the inverter in- case the solar inverter is ready to be installed or faulty so that all the light will be working on grid/generator
Re: Electrical Piping Both Surface And Conduit by Enyinne(f): 3:59pm On Jul 25, 2021
Thanks . Pls do u hv a good electrician that can do this job .
A flat of 3bedroom out of 4 flats. Fixing only 1 flat now to move in .
Location Ajah
topsy23:


That means you need to add additional small single phase distribution board like or 6ways

So that 80or 90% of light will be in solar and some selected socket .

1.5mm for lighting, ceiling fan, extractor fan + external light
Red. 5
Black 4
Green 2

2.5mm for socket
Red 2
Black 2
1.5mm green 2

4mm for AC and water heater
Red. 2
Black 2
2.5mm green 2

10mm
Red 1
Black 20m

6mm 3-core for inverter 30m

And let your electrician provide a by-pass for the inverter in- case the solar inverter is ready to be installed or faulty so that all the light will be working on grid/generator
Re: Electrical Piping Both Surface And Conduit by topsy23: 4:30pm On Jul 25, 2021
Enyinne:
Thanks . Pls do u hv a good electrician that can do this job .
A flat of 3bedroom out of 4 flats. Fixing only 1 flat now to move in .
Location Ajah

You mean my workers
Re: Electrical Piping Both Surface And Conduit by Enyinne(f): 4:40pm On Jul 25, 2021
A good electrician that can do it . The job is at Sangotedo. I don't know ur location.?
If your company can do it , we can discuss over it
topsy23:


You mean my workers
Re: Electrical Piping Both Surface And Conduit by topsy23: 7:16pm On Jul 25, 2021
Enyinne:
A good electrician that can do it . The job is at Sangotedo. I don't know ur location.?
If your company can do it , we can discuss over it

We can handle it for you.

You can send me the plan on whatsapp
Re: Electrical Piping Both Surface And Conduit by Mykel51(m): 7:49pm On Jul 25, 2021
You carry out the MEP design and construction right ?
Re: Electrical Piping Both Surface And Conduit by topsy23: 8:05pm On Jul 25, 2021
Mykel51:
You carry out the MEP design and construction right ?

Yes sir
Design and build

1 Like

Re: Electrical Piping Both Surface And Conduit by topsy23: 10:26am On Jul 31, 2021
Mykel51:
You carry out the MEP design and construction right ?

Good morning sir

1 Like

Re: Electrical Piping Both Surface And Conduit by folmus: 9:44am On Aug 30, 2021
@topsy23,

What quantities (rough estimates) of cables will be needed for wiring 2 Units of 2 beds and 5 Units of mini flat. ?

Let's see if we can do something together.


Thanks
Re: Electrical Piping Both Surface And Conduit by topsy23: 12:44pm On Aug 30, 2021
folmus:
@topsy23,

What quantities (rough estimates) of cables will be needed for wiring 2 Units of 2 beds and 5 Units of mini flat. ?

Let's see if we can do something together.


Thanks

Thanks for the message

For 2units of 2bedroom flat below is the list of cables needed

1.5mm
Red. 4
Black 3

2.5mm
Red 3
Black 3
1.5mm green 3

4mm for AC
Red 2
Black 2
2.5mm green 2

For 5-units of mini flat i.e room and a sitting
1.5mm
Red 6
Black 6

2.5mm
Red 4
Black 4
1.5mm green 4

4mm
Red 3
Black 3
2.5mm green 3

6mm for DB for single phase DB
Red 1
Black 1
Green 4mm 1

Above depends on number of AC
Re: Electrical Piping Both Surface And Conduit by topsy23: 5:06pm On Aug 31, 2021
On going surface pipe work

Re: Electrical Piping Both Surface And Conduit by topsy23: 9:04am On Sep 23, 2021
More picture

Re: Electrical Piping Both Surface And Conduit by Abiola365: 6:04pm On Sep 23, 2021
topsy23:
Am creating this thread to show case our conduit and surface system of piping.

Feel free to comment ask question, Below are some steps for surface slab piping

Laying of Lighting Pipes around a Beam
• Use of blue line to determine the route up to the edge of the beam
• Vertically place a plumb to transfer the line to the base of the beam
• Horizontally place the plumb at the base of the beam to transfer the line to the other side of the beam
• Then vertically place a plumb at the other side to transfer the line to the base of the beam.
• Blue line is use to transfer the line to other lighting point locations on a straight line
• Transfer the measurements to the pipes
• The vertical length of the beam gives the bending radius of the pipes
• Use the bending spring to achieve the bending radius
• Fixing of the bent pipes around the beam
• The pipes are linked together with couplers
• Adaptable boxes to be used where many pipes are crossing each other
• Linking of pipes to distribution boards.


Contact us today for your Electrical Mechanical Design and Installation

Check out our thread

Distribution boards
https://www.nairaland.com/2668061/abb-distibution-board-schneider-distribution/6

MEP installation
https://www.nairaland.com/1233943/contact-us-electrical-mechanical-plumbing/25

Cables
https://www.nairaland.com/2326721/nigerchin-kabelmetal-coleman-cables/23
this is great, I just discover this thread and it's really educative, as a young electrical technician/engineer I thought I have known almost all about electrical piping before but your jobs makes me realize I still have a lot to learn, you are doing a great job sir.
Re: Electrical Piping Both Surface And Conduit by topsy23: 6:57pm On Sep 23, 2021
Abiola365:
this is great, I just discover this thread and it's really educative, as a young electrical technician/engineer I thought I have known almost all about electrical piping before but your jobs makes me realize I still have a lot to learn, you are doing a great job sir.

Thanks for your comment
Re: Electrical Piping Both Surface And Conduit by topsy23: 9:53pm On Oct 10, 2021
Decking pipe work

(1) (2) (3) (Reply)

Lekki Vale is Located At Bolorunpelu Opposite The New Lekki Airport ,N5.5m / BEST & AFFORDABLE BUILDING APPROVAL PLAN, CONSTRUCTION AND APPROVAL DRAWING IN N / Fire Accident Occur At Shibiri Ojo, Lagos (photos)

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 32
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.