Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 7:48am On Feb 16, 2022
1000w solar street light available, #40,000. Call/WhatsApp me on 08168986461

Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 7:50am On Feb 16, 2022
10kva 48v felicity inverter available, #550,000. Call/WhatsApp me on 08168986461

Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 7:53am On Feb 16, 2022
7.5kva 48v Yohako wall mount inverter available, #250,000. Call/WhatsApp me on 08168986461

Re: Solar Energy, A Complement To FTA by ojeysky(m): 8:17am On Feb 16, 2022
ajabani4allah:
I need a very Good charger for 12.6v 100Ah LifePo Battery. If you have please send the picture and the price

I have 0 to 50A adjustable current and voltage charger for 45k
Re: Solar Energy, A Complement To FTA by earthrealm(m): 8:57am On Feb 16, 2022
smallsmall:

You sure say you reason this one well at all?
There are Hybrid Models of the same capacity or less, if the "idle power consumption" was the only problem.

Unless you saying the Inverter will not charge the batteries or it would not give output or he cant expand his battery bank to 8units or even change to Lithium batteries in the nearest future? grin

Battery size is a function of many variables but it is better to oversize the inverter from the get-go, (due to its high, initial cost outlay) and then gradually increase the size of your batteries to it (no negative consequence), than to under-size your Inverter from the beginning, then you have to pay big money to buy one of higher capacity, when your needs increase.
And you can bet, needs always increase over time.



the matter complex small, 8kva non hybrid inverter would hv about 450w idle consumption. this is about 10kwh, more than the total energy capacity of 4 units 220ah battery........................
4kw to 6kw is ok for most avg homes.......................judging from the Op's post, one can deduce that 8kw would be an overkill for him
Re: Solar Energy, A Complement To FTA by kiekie1(m): 9:59am On Feb 16, 2022
UP FOR SALE!!



GROWATT 5000 ES 48v HYBRID INVERTER FOR SALE!!!

GROWATT 5000 watts 48v ES (100a / 450 VOC 6000w inbuilt MPPT) under warranty with its accessories up for SALE "Worked just once as project sample" ...

Condition: Minty new shape . Enclosed in its carton with all accessory & warranty

Location: Lagos state

For further enquiry & purchase;
Contact,
Smartcell global services
CALL LINE: 081-350-31951
WHATSAPP::: http://.us/w/?c=a46ea5

Re: Solar Energy, A Complement To FTA by kiekie1(m): 10:07am On Feb 16, 2022
HURRY!! GET YOURS NOW !!!

SCHNEIDER 1.5KVA 24V (1000w solar input) pure sine wave inverter ..... Unit price 85,000

SCHNEIDER connext 2524 inverter ... 660,000

SCHNEIDER connext 7048 inverter .... 1,555,000

SCHNEIDER connext 8548 inverter ... 1,635,000

SCHNEIDER connext 8548 pro inverter ... 1,800,000

SCHNEIDER connext 60a mppt .... 295,000

SCHNEIDER connext 100a mppt .... 700,000

SMA sunny island 6.0 ... 1.370,000

SOROTEC 3KVA TL REVO VMII 3KW 24V - 100A MPPT ... "Updating"

SOROTEC 5.5KVA TL REVO VMII 5.5KW - 48V - 100A MPPT .... "Updating"

SOROTEC 5.5KVA TL PREVO VMII 5.5KW - 48V - 100A MPPT (PARALLEL) ... "Updating"

SOROTEC WIFI MODULE
WIFI MONITORING ROD ... 35,000

German Phocos hybrid inverter 5kw 48v - 80A MPPT .... 590,000

Gennex hybrid 3000w 24v (60a mppt) ... 300,000

Anern Hybrid 3200w 24v (80a mppt) .. 310,000

Anern hybrid 5200w 48v ...... 400,000

Axpert VMIII 3000w 34v (100a mppt) hybrid .... 450,000


ERA MONO SOLAR PANELS
Era 300w ... 73,500
Era 300w black ....75,000
Era 320w black .... 78,500
Era 330w ..... 80,000
Era 370w black ... 90,000
Era 400w ....... 97,000
Era 450w ........ 105,000

JINK0 MONO HALFCUT SOLAR PANELS
Jinko 380w .... 98,000
Jinko 400w .... 100,000
Jinko 470w .... 120,000
Jinko 540w .... 135,000

VOLTRONIC 3KVA - VM - TL
AXPERT VM 3000 - 24V - 1500W MPPT 60A ... "Updating"

VOLTRONIC 5KVA - VM - TL
AXPERT VM 5000 - 48V - 3000W MPPT 60A ... Updating

VOLTRONIC 5KVA - MKS - TL
AXPERT MKS 5000 - 48V - 4000W MPPT 80A ... 395,000

VOLTRONIC 7.2KVA - MAX - TL
AXPERT Max 7200 - 48V (wifi & parallel compatible) - 8000W MPPT 80A PV 500 .... 800,000

VOLTRONIC WIFI MODULE
WIFI CONNECTIVITY MODULE ...... 30,000

VOLTRONIC PARALLEL KIT
PARALLEL CONNECTION KIT .... Updating

AXPERT VMIII 3kw 24v TL 100A MPPT ... 450,000

AXPERT VMIII 5kw 48v TL 100A MPPT ... 550,000

AXPERT VMIV 5.6kw 48v TL 120A MPPT .... 650,000

AXPERT VMII 5kw 48v TL 100A MPPT with parallel kit..... 630,000

AXPERT VMIV 5.6kw 48v TL 120A MPPT with parallel kit ... 720,000

AXPERT VMII 8kw 48v TL 150A MPPT ...... 1,150,000

Parallel kits "MKS & MKII" .... 40,000

GROWATTS PRODUCTS:

GROWATT 3KVA TL KVA 424V HVM-50A MPPT ... 335,000

GROWATT 3KVA TL KVA 48V HVM-50A MPPT .. 300,000 "Promo"

GROWATT 3.5kVA TL KVA 48V ES-80A MPPT .. 500,000

GROWATT 5KVA TL5KVA 48V HVM-P-80A MPPT .. "updating"

GROWATT 5KVA TL5KVA 48V ES-100A MPPT Battery less hybrid inverter ... 600,000

GROWATT 6KVA T6KVA 48V HVM TRANS -80A MPPT ... Updating

GROWATT 8KVA T8KVA 48V HVM TRANS -120A MPPT ... 875,000

GROWATT 10KVA T10KVA 48V HVM TRANS -120A MPPT .. Updating

GROWATT 12KVA T12KVA 48V HVM TRANS -120A MPPT ... Updating

Growatts WIFI / GPRS module ... 30,000

LITHIUM BATTERIES:

SHOTO 4.8kwh lithium ion Battery .. 970,000

GROWATT HOPE 3.3kwh lithium ......... 700,000

PYLONTECH US 2000 2.4kwh lithium .... 648,000

PYLONTECH US 3000 3.6kwh lithium .... 905,000



EPEVER 5KVA 5KVA 48V 80A MPPT PV200V ... 350,000

USA TROJAN 12v 205A battery .... 223,000

BATTERY BALANCER 48V .... 35,000

BATTERY DESULFATOR/REJUVENATOR REJUVENATOR 12V, 24V, 36V, 60V, 72V ... 35,000

Quanta 200a battery ..... 160,000 "unit price".

Monbat 200a battery .... 190,000

Exide Index 200a battery ..... 160,000

C & D AES 196a battery .... 190,000

HBL Optimus 200a battery ..... 150,000

Matrix 220a battery ... 125,000

Novel solar 220a Tubular battery .... 124,000

Exulted / 220a Tubular battery.... 130,000

Genus 230a lead carbon Tubular battery... 140,000

Ritar 200AH 12V battery price is 145,000/- per battery.

Ritar 150AH 12V slim ..... 132,000

Ritar 105AH 12V Slim ... 122,000

MERCURY BATTERY Available Now With One Year Warranty!

Mercury 100ahs deep cycle battery ..75,000

Mercury 220a tubular ... 125,000

Pure sine wave 1kva 12v inverter ... 65,000

Epever 40a mppt "programmable user friendly lcd interface" .... 70,000

Pro solar roof mount set "comfortably takes four units of 300 to 600w panels" .... 45,000

All brand new with standard warranty!

Contact,
Smartcell global services
CALL ONLY:: 081-350-31951
WHATSAPP::: http://.us/w/?c=a46ea5

Re: Solar Energy, A Complement To FTA by CAROLYN19: 11:25am On Feb 16, 2022
For Industrial Power Backup Solution equipment such as 6KVA TO 1000KVA VERTIV/EMERSON/ LIEBERT UPS, SCHNEIDER INVERTERS, 3KVA TO 1000KVA AUTOMATIC VOLTAGE REGULATOR & All sizes of GASTON BATTERIES. Call/Watsapp us on 08066332919. We have offices in Lagos &Abuja and we do nationwide delivery

Re: Solar Energy, A Complement To FTA by ajabani4allah(m): 10:09pm On Feb 16, 2022
dollarnaira:


Output voltage of 12.8 is for lithium settings for 3s. Lead acid charges at 14.4v at automatic setting. The manual settings go as far as 15.7v.

Probably you had a defective one.

If the setting of the lithium battery is 4s what would be the correct charging voltage of the charger?
Re: Solar Energy, A Complement To FTA by dollarnaira: 11:16pm On Feb 16, 2022
ajabani4allah:


If the setting of the lithium battery is 4s what would be the correct charging voltage of the charger?
13.8v
Re: Solar Energy, A Complement To FTA by ajabani4allah(m): 11:39pm On Feb 16, 2022
dollarnaira:

13.8v

I thought it will be 14.8v because voltage of each of the 4cells in series is around 3.7 totaling 14.8v
Re: Solar Energy, A Complement To FTA by olopan(m): 1:59am On Feb 17, 2022
@ajabani4allah & @dollarnaira

A quick contribution to your conversation

LiFePO4 @ nominal voltage is @3.2V while fully charge at 3.6V - so a 3s/4s is 9.6V/12.8V charging to full voltage will be 10.8V/14.4V

While Li-ion @ nominal is 3.7V while fully charged is 4.2V - so a 3s is 11.1V charging to full voltage is 12.6V

LiFePO4 is closely related to Lb based batteries when been used with conventional inverters

2 Likes

Re: Solar Energy, A Complement To FTA by chris81964(m): 5:22am On Feb 17, 2022
Re: Solar Energy, A Complement To FTA by dollarnaira: 6:38am On Feb 17, 2022
ajabani4allah:


I thought it will be 14.8v because voltage of each of the 4cells in series is around 3.7 totaling 14.8v

Thought u were talking of LifePO4 at 4s.
Yes lithium ion at 4s is 14.8v(nominal charge).
Full charge is 16.8v
Re: Solar Energy, A Complement To FTA by dollarnaira: 6:42am On Feb 17, 2022
olopan:
@ajabani4allah & @dollarnaira

A quick contribution to your conversation

LiFePO4 @ nominal voltage is @3.2V while fully charge at 3.6V - so a 3s/4s is 9.6V/12.8V charging to full voltage will be 10.8V/14.4V

While Li-ion @ nominal is 3.7V while fully charged is 4.2V - so a 3s is 11.1V charging to full voltage is 12.6V

LiFePO4 is closely related to Lb based batteries when been used with conventional inverters
@olopan
Safe charging for LifePO4 3.2v at 4s is 13.8v.Some do 14.0 but i safety do 13.7v to extend battery life.
Re: Solar Energy, A Complement To FTA by Dishtech(m): 8:33am On Feb 17, 2022
ajabani4allah:


If the setting of the lithium battery is 4s what would be the correct charging voltage of the charger?
The Maximum charging voltage.
If Li ion battery= 4.2 x 4= 16.8 but if LiFeO4= 3.65 x 4=14.6 but you can charge Li ion at 4x4= 16v, and LiFeO4 at 3.5x4= 14volt. Because lithium batteries are not to left on a peak voltage of 4.2v and 3.65v per cell of Li ion and LiFeO4 respectively.
Re: Solar Energy, A Complement To FTA by AkoEja: 12:06pm On Feb 17, 2022
Does anyone here use Lithium Titanate batteries?
Can you give us some review of real-world experience or point in the direction of one?
Any suppliers locally in Nigeria?
Re: Solar Energy, A Complement To FTA by ajabani4allah(m): 12:08pm On Feb 17, 2022
Dishtech:

The Maximum charging voltage.
If Li ion battery= 4.2 x 4= 16.8 but if LiFeO4= 3.65 x 4=14.6 but you can charge Li ion at 4x4= 16v, and LiFeO4 at 3.5x4= 14volt. Because lithium batteries are not to left on a peak voltage of 4.2v and 3.65v per cell of Li ion and LiFeO4 respectively.

I have a 12vDC ceiling fan and a 12v plasma tv I can plug directly to the battery. I am considering the Li ion 4s(16.8v full charge) cells because my fan doesn't start at the 12v rated voltage it starts around 14v but I am thinking if this will not damage the tv and the fan

Also, which of the batteries has more life cycle?
Re: Solar Energy, A Complement To FTA by taiwooguns33(m): 7:17pm On Feb 17, 2022
Pls can somebody help me with names of 1.5 or 2kva 24volt pure sine wave inverter with low idle consumption.
Re: Solar Energy, A Complement To FTA by kiekie1(m): 5:41am On Feb 18, 2022
WE BUY DEAD/SCRAP BATTERIES!!!

We also buy off scrap/dead deep cycle batteries from any state to Lagos (Terms & Condition applies) ..

12v 200a .... N20,000
12v 150a.....N15,000
12v 100a.......N10,000
2v 500a ......N6,000

Free pickup within Lagos mainland ! Shared cost logistics within Lagos Island environs . . If outside Lagos state , send the scrap batteries to your nearby Lagos park & get your payment alert immediately after confirmatory remarks from me with the transport company manager / secretary or driver (shared logistics cost depending on scrap battery quantity) ..

Contact,
Smartcell global services
CALL:: 081-350-31951
WHATSAPP::: https:///2348170385620

Re: Solar Energy, A Complement To FTA by Dishtech(m): 6:07am On Feb 18, 2022
ajabani4allah:


I have a 12vDC ceiling fan and a 12v plasma tv I can plug directly to the battery. I am considering the Li ion 4s(16.8v full charge) cells because my fan doesn't start at the 12v rated voltage it starts around 14v but I am thinking if this will not damage the tv and the fan

Also, which of the batteries has more life cycle?
I can't guarantee you that because most electronic has a maximum high voltage tolerance level. I can advise you to make a different power bank for the fan with 4s lithium battery and 3s for the TV. You can equally buy a boost converter
Re: Solar Energy, A Complement To FTA by ceaser: 6:34am On Feb 18, 2022
ajabani4allah:


I have a 12vDC ceiling fan and a 12v plasma tv I can plug directly to the battery. I am considering the Li ion 4s(16.8v full charge) cells because my fan doesn't start at the 12v rated voltage it starts around 14v but I am thinking if this will not damage the tv and the fan


A buck converter will be your best option if you are to use a 4s (16.8v) Li-ion pack. In fact using a 14s in this scenario is not a bad idea. But if your TV does well on 12v input and your DC fan does not pick up at that voltage until it gets to 14v, the two volts disparity means you will need one buck converter for each device - one set at 12v output for the TV and the second one set at 14v output for the DC fan.

You can check up on AliExpress for good buck converters.

ajabani4allah:

Also, which of the batteries has more life cycle?

Both Li-ion and LFP are good chemistries with appreciable life cycle. Li-ion initially has much less cycles (around 2500) than LFP but new improvements have significsntly extended that, though not at par with the 4000 cycles boasted by LFP yet.

Li-ion has significantly more energy density than LFP such that Tesla and some other BEV makers prefer to use it for their high performance trims where rapid rush/drawing of electric current is required. However Li-ion is less safer than LFP with the risk of fires. But even fire risk with Li-ion is significantly low with use of proper Battery Management System devices.

Dishtech:

I can't guarantee you that because most electronic has a maximum high voltage tolerance level. I can advise you to make a different power bank for the fan with 4s lithium battery and 3s for the TV. You can equally buy a boost converter

I guess you have a typo there. What he requires is a buck converter to bring 16.8v down to lower voltages.
Re: Solar Energy, A Complement To FTA by alstacs(m): 7:39am On Feb 18, 2022
NiyiOmoIyunade:
Yes flooded batteries indeed exhibit lower voltage than other lead acid chemistries while at rest and at work.

However at 58v you are not charging your batteries to full. In general flooded batteries need to get to a minimum of about 14.6v per 12v battery i.e 58.4v for the battery pack. Ideally they should absorb at 14.7 to 14.8v per 12v battery which is a range of 58.8v to 59.2v for the battery pack.

Every month or so, you need to equalize the batteries and get them into the 15v per 12v battery range

It will be useful to read your battery data sheet (some info should be on the battery case) and adjust charging parameters accordingly if your inverter is capable.

If at any point in troubleshooting , the dealer swapped out or topped off electrolyte, then you are in a delicate place as they may have used too strong or too weak of a mix - an hydrometer is your best friend to know the SG and SoC of your batteries and inform your next steps.



Good morning house.. Please what is the minimum cutoff voltage for tubular batteries?

I realised the default on Ipower inverter is 10.5V for a 12V system and 42V for a 48V system. I consider this abysmally low based on what I see here.
I would like to change the default settings but I need guidance on the figure knowing fully well these batteries show low voltages even when fully charged and the charging source removed

Re: Solar Energy, A Complement To FTA by ajabani4allah(m): 8:14am On Feb 18, 2022
ceaser:


A buck converter will be your best option if you are to use a 4s (16.8v) Li-ion pack. In fact using a 14s in this scenario is not a bad idea. But if your TV does well on 12v input and your DC fan does not pick up at that voltage until it gets to 14v, the two volts disparity means you will need one buck converter for each device - one set at 12v output for the TV and the second one set at 14v output for the DC fan.

You can check up on AliExpress for good buck converters.



Both Li-ion and LFP are good chemistries with appreciable life cycle. Li-ion initially has much less cycles (around 2500) than LFP but new improvements have significsntly extended that, though not at par with the 4000 cycles boasted by LFP yet.

Li-ion has significantly more energy density than LFP such that Tesla and some other BEV makers prefer to use it for their high performance trims where rapid rush/drawing of electric current is required. However Li-ion is less safer than LFP with the risk of fires. But even fire risk with Li-ion is significantly low with use of proper Battery Management System devices.



I guess you have a typo there. What he requires is a buck converter to bring 16.8v down to lower voltages.


Thanks so much for this knowledge based answer, I really appreciate

1 Like

Re: Solar Energy, A Complement To FTA by Dishtech(m): 9:36am On Feb 18, 2022
ceaser:


A buck converter will be your best option if you are to use a 4s (16.8v) Li-ion pack. In fact using a 14s in this scenario is not a bad idea. But if your TV does well on 12v input and your DC fan does not pick up at that voltage until it gets to 14v, the two volts disparity means you will need one buck converter for each device - one set at 12v output for the TV and the second one set at 14v output for the DC fan.

You can check up on AliExpress for good buck converters.



Both Li-ion and LFP are good chemistries with appreciable life cycle. Li-ion initially has much less cycles (around 2500) than LFP but new improvements have significsntly extended that, though not at par with the 4000 cycles boasted by LFP yet.

Li-ion has significantly more energy density than LFP such that Tesla and some other BEV makers prefer to use it for their high performance trims where rapid rush/drawing of electric current is required. However Li-ion is less safer than LFP with the risk of fires. But even fire risk with Li-ion is significantly low with use of proper Battery Management System devices.



I guess you have a typo there. What he requires is a buck converter to bring 16.8v down to lower voltages.

Typo error, I mean buck converter I believe he should understand that it was a typographical error.
Re: Solar Energy, A Complement To FTA by Thunderbolt: 10:52am On Feb 18, 2022
Trying to get a relatively cheap hybrid inverter.
Could someone kindly recommend which I should go for between the 2 brands, MUST and FELICITY?

Thanks
Re: Solar Energy, A Complement To FTA by Valto(m): 11:27am On Feb 18, 2022
Thunderbolt:
Trying to get a relatively cheap hybrid inverter.
Could someone kindly recommend which I should go for between the 2 brands, MUST and FELICITY?

Thanks
none are good enough. get a SOROTEC or ANERN.
Re: Solar Energy, A Complement To FTA by ojeysky(m): 12:06pm On Feb 18, 2022
earthrealm:


the matter complex small, 8kva non hybrid inverter would hv about 450w idle consumption. this is about 10kwh, more than the total energy capacity of 4 units 220ah battery........................
4kw to 6kw is ok for most avg homes.......................judging from the Op's post, one can deduce that 8kw would be an overkill for him

It's safer to say "could have" as there are 8kw non hybrid that consumes way less than that

1 Like

Re: Solar Energy, A Complement To FTA by Thunderbolt: 4:20pm On Feb 18, 2022
Valto:
none are good enough. get a SOROTEC or ANERN.

Thanks so much for the advice.
However these brands seem to be a bit difficult to find.
Re: Solar Energy, A Complement To FTA by earthrealm(m): 5:49pm On Feb 18, 2022
Thunderbolt:


Thanks so much for the advice.
However these brands seem to be a bit difficult to find.

Yeah, they are rugged, and thus cost slightly more than their contemporaries, thus people shy away from buying them
Re: Solar Energy, A Complement To FTA by adrusa: 5:51pm On Feb 18, 2022
Valto:
none are good enough. get a SOROTEC or ANERN.

Well, I have had a Felicity for more than a year. Has never coughed for a single day.
Re: Solar Energy, A Complement To FTA by Valto(m): 6:02pm On Feb 18, 2022
earthrealm:


Yeah, they are rugged, and thus cost slightly more than their contemporaries, thus people shy away from buying them
ANERN 24v is not that costly sha he can get it much less than 300k.

(1) (2) (3) ... (1123) (1124) (1125) (1126) (1127) (1128) (1129) ... (1855) (Reply)

FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 69
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.