Re: Solar Energy, A Complement To FTA by mctfopt: 12:34pm On Jul 09, 2022 |
litaninja: Is the SPD display still green? |
Re: Solar Energy, A Complement To FTA by litaninja(m): 2:33pm On Jul 09, 2022 |
Re: Solar Energy, A Complement To FTA by mctfopt: 2:58pm On Jul 09, 2022 |
litaninja: I hope the earthing is still effective |
Re: Solar Energy, A Complement To FTA by viperVIP: 2:59pm On Jul 09, 2022 |
If you are in Abeokuta, I have 4 panels of 225w each for sale. 60a pwm charge controller 1500va 24v PSW Inverter. If you are interested, whatsapp O813768924O |
Re: Solar Energy, A Complement To FTA by Namzy(m): 3:19pm On Jul 09, 2022 |
IYGEAL:Please I need your contact or WhatsApp number |
Re: Solar Energy, A Complement To FTA by IYGEAL(m): 3:29pm On Jul 09, 2022 |
Namzy:. |
Re: Solar Energy, A Complement To FTA by Namzy(m): 4:14pm On Jul 09, 2022 |
... |
Re: Solar Energy, A Complement To FTA by litaninja(m): 7:01pm On Jul 09, 2022 |
I did a quick test across an outlet's terminals just to check, I'm within expected voltage levels. mctfopt: |
Re: Solar Energy, A Complement To FTA by ojeysky(m): 10:25pm On Jul 09, 2022 |
litaninja: I had similar experience during my MPP days, a board replacement was the fix, thankfully mine was still under warranty so I only paid for shipping of the Board. 1 Like |
Re: Solar Energy, A Complement To FTA by mctfopt: 8:36am On Jul 10, 2022 |
litaninja: Can you elaborate on the earth test you did? |
Re: Solar Energy, A Complement To FTA by olopan(m): 11:40am On Jul 10, 2022 |
You will need a 275Vac 20/40kA SPD to be in line with your AC input/charging of the Inverter with an MCB Also a 60-90Vdc SPD in line with your solar PV or charge controller input with an MCB With circuit breakers closely match to your load demand as input&output protections. With these you should be okay. HilcomTech: |
Re: Solar Energy, A Complement To FTA by litaninja(m): 11:44am On Jul 10, 2022 |
Sure. L - N --> voltage reading 1 L - E --> voltage reading 2 N - E --> voltage reading 3 (voltage reading 2 - voltage reading 1) + voltage reading 3 = 1.7v I believe this falls in the expected range of 0 - 2v? mctfopt: 1 Like |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 1:34pm On Jul 10, 2022 |
What you really tested below is how your facility wiring was done whether it is up to code or not. A proper earth effectiveness test requires you to isolate the earth electrode (rod) and test the resistance with a earth megger/tester - I look for resistance 5 Ohms or less but a residence can get by with something as bad as 100 Ohms. In practice, what we do is not bother the earth rods at all but rather remove the main earth cable from DB or earth bus bar and test backwards from there - we connect the earth rod side of the tester to the exposed earth cable and the other two test legs to the test spikes and run the resistance test - with this scheme you are able to test the effective resistance of the total earth system from facility earth cable all the way back to the buried rods. litaninja: 5 Likes 2 Shares |
Re: Solar Energy, A Complement To FTA by Namzy(m): 4:54pm On Jul 10, 2022 |
NiyiOmoIyunade:But won't his test translate to a good earth? |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 5:49pm On Jul 10, 2022 |
litaninja: WHAT TOOL did you use to arrive at this classification of the earthing? poor earthing is the prime suspect in this scenario, since you say the spd is still green. i believe you have spd for dc and AC side?? 1 Like |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 7:04pm On Jul 10, 2022 |
Not in any way. That test is much more like an electrical isolation integrity or wire polarity test - the integrity or sufficiency of the actual earth installation was not tested at all. The results he got could be reproduced with a floating earth wire or a very very poor earth installation. The proper way to test an earth install is use a dedicated meter to perform a resistance test of the earth electrode(s) - I like to test backwards from the main earth wire of the facility - the (typically) 16mm2 wire that goes from the buried rods into the DB or earth bus bar. Namzy: 3 Likes 2 Shares
|
Re: Solar Energy, A Complement To FTA by mctfopt: 7:15pm On Jul 10, 2022 |
litaninja: The person above has beaten me to what I would've said In addition you can run a lamp test, that is place an incandescent bulb across L and E with your meter in place. The voltage reading should be the same with the bulb on live and neutral. But the best test remains using the earth tester. 3 Likes 1 Share
|
Re: Solar Energy, A Complement To FTA by Namzy(m): 7:47pm On Jul 10, 2022 |
NiyiOmoIyunade:What about a socket tester?
|
Re: Solar Energy, A Complement To FTA by litaninja(m): 9:31pm On Jul 10, 2022 |
mctfopt NiyiOmoIyunade earthrealm Thanks for the input / suggestions. I haven't seen an actual incandescent bulb in a while , but would try to find one during the week and run the lamp test. For the resistance test suggested by NiyiOmoIyunade, I'd need to find some time and the meter to carry out that test later on. Plus no be me get house, na baba landlord house, I'd need to start digging some concrete floors, e.t.c. Chai. mctfopt: |
Re: Solar Energy, A Complement To FTA by litaninja(m): 9:38pm On Jul 10, 2022 |
Regular Meter readings. But also got the suggestion to ran a lamp test with a meter inline which I'll carry out during the week. Yes, I have SPDs on the AC and DC sides. earthrealm: |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 9:49pm On Jul 10, 2022 |
litaninja: shud be easier doing a new dedicated earthing for yourself..ie if landlord has no isssh |
Re: Solar Energy, A Complement To FTA by litaninja(m): 10:06pm On Jul 10, 2022 |
I'd have to get the permission from him and that would also entail breaking up the concrete flooring of the compound as every single inch of ground is covered earthrealm: |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 10:06pm On Jul 10, 2022 |
No you do not need to dig up or disrupt anything. The way the tester works it has 3 wires - if you look at my picture the green wire clamps to your earth rod, while the yellow and red wires go to two test spikes that come with the test meter (you drive the spikes into the ground at certain distances from the main earth rod being tested) For your purpose simply take the main earth wire that serves your house or flat and assume that is your earth rod and attach the tester to it then go outside to bury the other short test spikes - a flower bed or such is a good place to use worst case. You need to disconnect the earth wire and keep it isolated while doing this test - you can easily use a long 2.5mm cable to reach from outside where you will do the test to inside where your earth wire probably rests litaninja: 3 Likes |
Re: Solar Energy, A Complement To FTA by litaninja(m): 10:28pm On Jul 10, 2022 |
Hmmm, noted. I'll make out the time to test that. In addition, is there anyway to test or determine if an SPD is faulty? NiyiOmoIyunade: |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 11:03pm On Jul 10, 2022 |
The way the utility provider does earthing in naija, the transformer neutral and earth rod may be bonded at the transformer. An electrician may further bond your neutral and earth busbar inside your DB to escape doing a proper earth or 'solve' an earth leakage problem - if you are in this situation then the bulb tests e.t.c will fail. litaninja: 1 Like 1 Share |
Re: Solar Energy, A Complement To FTA by isangjohnson: 11:22pm On Jul 10, 2022 |
Please my friend wants to know if it's possible to add LFP to his existing setup. He has about 3kw pv hooked on 48v 3.5kva Felicity and CC with 11kwh LA. Now, he wants to introduce Lfp into the system as an additional bank. The same pv and Inverter/cc will service the two battery bank (LA and LFP) If LA bank takes care of this night, LFP bank will take care of another night. Is just a matter of change over to a preferred bank. |
Re: Solar Energy, A Complement To FTA by litaninja(m): 1:21am On Jul 11, 2022 |
I can confirm neutral & earth are not bonded at the premises. Can't say the same for the transformer though. I'll do what I can about the tests suggested earlier as well. NiyiOmoIyunade: |
Re: Solar Energy, A Complement To FTA by FEGEITOK: 10:14am On Jul 11, 2022 |
Big question: Should I run an AVR from the output of the inverter? So that my load is not directly connected to the inverter but indirectly connected to the inverter through the AVR? Is this acceptable practice? |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 12:11pm On Jul 11, 2022 |
FEGEITOK: what do you hope to achieve by this/ inverter output is stable..avr iisnt needed, perhaps if you explain why u think u need an avr, then we can advice you better 6 Likes |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 12:20pm On Jul 11, 2022 |
isangjohnson: what u ask is doable. but for advanced users and alot of failsafe measures are needed to pull this off. so the simple answer to you, being a basic user is No dont do it..manage ur leadacid bank till it dies, then u switch to lithium. or decommision the leadacid battery....n go lithium fully |
Re: Solar Energy, A Complement To FTA by FEGEITOK: 6:08pm On Jul 11, 2022 |
earthrealm: My inverter has 2 modes ECO and UPS. ECO Mains high cut 290V +/- 10V ECO Mains high cut recovery 280V +/- 10V ECO Mains low cut 100V +/- 10V ECO Mains low cut recovery 110V +/- 10V ECO takes longer to discharge but has a range that hits 290 Volts UPS discharges faster but has a safer range of not more than 265 Volts UPS Mains high cut 265V +/- 10V UPS Mains high cut recovery 255V +/- 10V UPS Mains low cut 180V +/- 10V UPS Mains low cut recovery 190V +/- 10V Says to use UPS mode to run computers/sensitive equipment. Says not to use ECO mode to run computers. I am running computers on the inverter, but I don't wish to fry them. ECO mode is the default mode. I want to take advantage of the ECO mode but limit the risk to my equipment. |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 10:01pm On Jul 11, 2022 |
FEGEITOK: What is the make and model of this inverter?. No normal inverter outputs these above normal voltages, i wud even be wary of exposing my electronics to 265volts, not to talk of 290volts I think these voltages are input voltages, not output. You should use a dmm and measure the output of the inverter to be sure of these output voltages you posted 2 Likes |
(1) (2) (3) ... (1199) (1200) (1201) (1202) (1203) (1204) (1205) ... (1855) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: staticstring
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 93 |