Re: Solar Energy, A Complement To FTA by Tommynaku: 10:03pm On Jul 11, 2022 |
Please how much was the shipping of the inverter to Nigeria. Was there any custom duty paid? I intend making an order either on Aliexpress or Alibaba for a 48v 3.5kva inverter. I really need help from anyone that recently made a purchase from either of these platform abilityC: |
Re: Solar Energy, A Complement To FTA by FEGEITOK: 1:42am On Jul 12, 2022 |
earthrealm: Homaya 1.5KVA Maybe these are input voltages, but if they are input why tell me not to use computers and sensitive equipment on ECO mode I will act on your advice and use a DMM to measure the output voltages and report back |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 3:25am On Jul 12, 2022 |
You may be misreading your inverter manual. ECO mode does not take longer to discharge the battery - it is talking about the mains input AC voltage tolerance - in ECO mode your inverter will allow voltage from PHCN or Gen between approx 90 - 300v to pass through to your loads. In UPS mode, your inverter will allow mains voltage from PHCN or Gen from approx 170v - 275v to pass through to your loads. Also the transfer time in case of mains failure is shorter so that your sensitive equipment e.g computer does not reboot. It is clear that these basic inverters offer scant protection to your equipment or loads at the voltage levels they allow to pass through - it is always best to install voltage protection at the input side of your inverter and set a threshold between 180v - 248v. From above 265v you should witness light bulbs going pop and circuits running hot/burning out, I also don't think motor windings like to be fed too high a voltage. FEGEITOK: 4 Likes 1 Share |
Re: Solar Energy, A Complement To FTA by FEGEITOK: 6:27am On Jul 12, 2022 |
NiyiOmoIyunade: Thanks for this extra information. I have been using this inverter for some 7 months and after this trial run, I want to get the Conext inverter which is superior I hope in protection as it is in load carrying capacity. Please recommend voltage protection for me. Is it the stabilizer or is it a surge arrestor or both? If yes, then appropriate capacity of each one if both or one or the other if just one of the two as well. Thanks again. 1 Like |
Re: Solar Energy, A Complement To FTA by FEGEITOK: 6:47am On Jul 12, 2022 |
brightk: How are things now? |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 9:34am On Jul 12, 2022 |
kiekie1: Available... |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 9:34am On Jul 12, 2022 |
WE BUY DEAD/SCRAP BATTERIES!!! We also buy off scrap/dead deep cycle batteries from any state to Lagos (Terms & Condition applies) .. 12v 200a .... N20,000 12v 150a.....N15,000 12v 100a.......N10,000 2v 500a ......N6,000 Free pickup within Lagos mainland ! Shared cost logistics within Lagos Island environs . . If outside Lagos state , send the scrap batteries to your nearby Lagos park & get your payment alert immediately after confirmatory remarks from me with the transport company manager / secretary or driver (shared logistics cost depending on scrap battery quantity) .. Contact, Smartcell global services CALL:: 081-350-31951 WHATSAPP::: http://.us/w/?c=a46ea5
|
Re: Solar Energy, A Complement To FTA by earthrealm(m): 10:23am On Jul 12, 2022 |
FEGEITOK: Its a normal warning on luminous, simba and other low end inverters. The have a switch at the back normal and ups. The significant difference in the output between the 2 modes is transfer time <10s3cs for ups and greater than 10s3cs for normal/eco... What this means is if you are on nepa and nepa goes, the inverter transfers from pass thru to inverter mode, this transfer takes some time...which sensitive equipment like computer can detect and go off, but the human eye is unable to detect this. Well built and Mid to high range inverters usually have ultra short transfer times...so this warning is irrelevant |
Re: Solar Energy, A Complement To FTA by GeorgeD1(m): 10:45am On Jul 12, 2022 |
FEGEITOK: brother, this inverter specs is totally at variance with the norm and its a disaster waiting to happen. i will advice you discontinue any further use until you have the funds to purchase a replacement. what you're toying with right now is a potential multiple damage to your electronics as well as a fire hazard. i think the engineers who designed such a derelict product need to have their heads examined. a word is enough... 2 Likes |
Re: Solar Energy, A Complement To FTA by FEGEITOK: 11:21am On Jul 12, 2022 |
earthrealm: I am getting a Conext XW 8548 Pro by month end I now want everything on the inverter not just computers Thanks for this explanation |
Re: Solar Energy, A Complement To FTA by IYGEAL(m): 1:19pm On Jul 12, 2022 |
GeorgeD1: In the interim, he can deploy appropriately sized AVR between grid and input; or some voltage/current limiting device as alternative - while he source for a better inverter. If the grid is always normal, you can do without those, but you can't bank on this. |
Re: Solar Energy, A Complement To FTA by FEGEITOK: 1:40pm On Jul 12, 2022 |
GeorgeD1:Thank you very much for your concern. The issue now is to determine an appropriately sized AVR to act as an in-between the inverter and the grid |
Re: Solar Energy, A Complement To FTA by FEGEITOK: 1:42pm On Jul 12, 2022 |
IYGEAL: If I didn't ask questions, I would never have known that when you buy the cheaper inverters, that you don't get all the protection of the expensive variants. I am sure others are learning as well. When it says 1.5 KVA, does that mean that I have to get an AVR greater in capacity than 1.5 KVA? |
Re: Solar Energy, A Complement To FTA by bbally: 1:55pm On Jul 12, 2022 |
abilityC: please how did you went through with the battery purchase in line with the dollar transaction restrictions from bank. I will need your help to order. |
Re: Solar Energy, A Complement To FTA by IYGEAL(m): 2:21pm On Jul 12, 2022 |
FEGEITOK: Yea, you should. 2KVA will do. Meanwhile, the AVR needs to be a good one and in good condition because I have seen AVRs pass excess voltage as received. |
Re: Solar Energy, A Complement To FTA by FEGEITOK: 2:27pm On Jul 12, 2022 |
IYGEAL: Thank you very much. I am in your debt. |
Re: Solar Energy, A Complement To FTA by mctfopt: 2:50pm On Jul 12, 2022 |
FEGEITOK: This is a rugged inverter. Cheers. |
Re: Solar Energy, A Complement To FTA by FEGEITOK: 3:44pm On Jul 12, 2022 |
mctfopt: My brother, I used to see 18 or more hours of grid power. But this year, things changed. Alternative power supply is no longer a luxury but a necessity. I don't want to talk about the fact that buying fuel in jerrycans at petrol stations is now considered a crime but buying the same fuel in jerrycans from black market suppliers on the street is legal activity. I therefore had no choice but to make alternative power arrangements, and now that I have seen some spare cash, I better improve my alternative power generating capabilities. Given the way the government and the power companies keep increasing the cost of power, I believe in the end, this project will pay for itself and reduce my dependence on outside sources for a key input for my production. I am following in your footsteps, and that is why I asked you about your experience a few days ago because I have fallen in love with the brand. 1 Like |
Re: Solar Energy, A Complement To FTA by mctfopt: 4:22pm On Jul 12, 2022 |
FEGEITOK: I agree with you, it's now a necessity to own a backup power as the government do not care about power for the masses. |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 5:28pm On Jul 12, 2022 |
Available now Sorotec 3.5kva Revo Vmii parallel 100a - 300k Sorotec 5.5kva Revo Vmii parallel 100a - 390k Parrallel kit - 30k 1 Like
|
Re: Solar Energy, A Complement To FTA by Jefferyzz(m): 7:47pm On Jul 12, 2022 |
Hi. My inverter doesn't charge my 200a 12v Lifepo4 battery efficiently. In the manual it states it's has 80a solar charger and pv input is 90-450vdc. My pv input is mostly between 126vdc to 131. The inverter at times will just stop charging and will b blinking the panel symbol.. inside hot sun at times my bms shows 12a going into my Lifepo4 cells while the inverter is not under any load. Im using 3 400w panels connected in series. My pv connection is good and intact.
|
Re: Solar Energy, A Complement To FTA by hisenjos: 7:52pm On Jul 12, 2022 |
Have you considered getting a Deye 8kw inverter. Specs are much better than the XW and has features that are extra cost on the XW. FEGEITOK: |
Re: Solar Energy, A Complement To FTA by mctfopt: 8:34pm On Jul 12, 2022 |
Jefferyzz: See if you can add three more PV and connect in series |
Re: Solar Energy, A Complement To FTA by FEGEITOK: 8:40pm On Jul 12, 2022 |
hisenjos: Will investigate the brand. Thanks for the heads-up |
Re: Solar Energy, A Complement To FTA by Jefferyzz(m): 8:43pm On Jul 12, 2022 |
Ahhh. Nah 1200w I don get currently oo. All are new panels. Ontop 12v system. mctfopt: |
Re: Solar Energy, A Complement To FTA by chris81964(m): 9:51pm On Jul 12, 2022 |
5 Likes |
Re: Solar Energy, A Complement To FTA by dollarnaira: 10:20pm On Jul 12, 2022 |
Jefferyzz: Me no like all these "all in one stuff". How do I know d inbuilt cc is mppt and not pwm? And if at all it was "mppt", how am I so sure it is a true amp rating? I like dem each by each for quick replacement in case sth happened. Inverter Cc Charger...My way. If possible test with another cc to confirm charging above d 12a. 1 Like |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 10:36pm On Jul 12, 2022 |
Jefferyzz: SO THIS YOUR INVERTER IS 12V MODEL?..u should have snapped the side, showing the specs..most high voltage hybrid inverters, their sweet spot is about 270 volts, the Voc of the avg 400 watts panel is 43 volts , so you need to increase your panel to 7 panels in series, wch wud be massive for your puny 12 volts 200 ah bank ----it appears u didnt do any serious research b4 setting up this your systenm. all is not lost.you cab either look for a decentmppt standalone charge controller... ...and connect the 3 panels to it 1 Like |
Re: Solar Energy, A Complement To FTA by bbally: 11:29pm On Jul 12, 2022 |
Jefferyzz: I will suggest you buy a solar cc separate to charge the battery and do your panels in parallel becos ur panel voc is far higher than ur battery nominal 12v. so by this, you will have higher current to charge ur battery. the new mppt (e.g powmr) will help balance the excess voltage with current for use under load. |
Re: Solar Energy, A Complement To FTA by Jefferyzz(m): 1:43am On Jul 13, 2022 |
Yh. I'm planning on getting this. Which charger controller under 100k that can handle 130vdc do you recommend. earthrealm: |
Re: Solar Energy, A Complement To FTA by Jefferyzz(m): 1:46am On Jul 13, 2022 |
Powmr 60a cannot handle more than 100vdc. Kindly check this out if it's 5n bbally:
|
Re: Solar Energy, A Complement To FTA by Jefferyzz(m): 1:50am On Jul 13, 2022 |
60a 12/24/48 techfine cc
|
(1) (2) (3) ... (1200) (1201) (1202) (1203) (1204) (1205) (1206) ... (1855) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: bkuranga(m), truthbetold22 and 3 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 68 |