Re: Solar Energy, A Complement To FTA by isangjohnson: 1:47am On Dec 14, 2022 |
durodee:I've not checked the voltage range in the manual yet but if it's in that range, do you suggest I should go for 10S1P in order to arrive at 493V and 94A? Mppt max charge current is 100A. 12pcs/6S2P is 113A. I think few losses from 10mm cables could bring it down to probably 93A. I've done 84A with 60A CC max charging current and 3S3P x 49.3Voc = 148V going into Max Mppt CC of 150Vdc with 6mm cables before. I was relaxed because I knew there would be greater loss due to the 6mm cables. |
Re: Solar Energy, A Complement To FTA by isangjohnson: 1:52am On Dec 14, 2022 |
jonescosmos:Vmp is 41.5v Imp is 10.8A Is 10S1P better than 6S2P interms of waking up the CC early and sleeping late? Downside: With my existing 450w Pv, I may be finding it difficult to really get a perfect setpoint as I'm struggling to push my array close to 6kw limit just to accommodate day time loads and fill up my battery at the same time. |
Re: Solar Energy, A Complement To FTA by durodee(m): 3:09am On Dec 14, 2022 |
isangjohnson:Yes to the question. Also note that there is a reason National grid transmits long distances using HIGH voltage: there is less energy loss and also affording the use of thinner wires as the case may be. So I have a basic principle with high voltage hybrid inverters. I will ramp up the voltage as high as I can first before thinking of parallel setup. Just be careful you don't break the voltage ceiling. If you break the amp ceiling, the Cc will just cap it at its capacity and continue working. If you break the voltage ceiling, then................ In extremely maxing out the capacity of equipment just remember that most times, the benefits does not always outweigh the risks. 3 Likes |
Re: Solar Energy, A Complement To FTA by Oshomo12(m): 6:25am On Dec 14, 2022 |
isangjohnson: First thing first, check your mppt voltage range before taking suggestions. Plz do this first. 1 Like |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 7:14am On Dec 14, 2022 |
isangjohnson: Guess you didnt plan it properly from the get go, i mean the voc issh vis a vis the hybrid panel layout. hybrids perform best if the incoming Voc are above 280v. in one of my installs, am running 7s2p 330w panels with Voc of 43v. i think at this late hour, you have 2 options 1. reconfirm your hybrid limits, and consider buying 2 additional panels, so as to run 7s2p 2. sacrifice 1 panel - sell or keep it aside...and run 11s1p with the existing panels you have already |
Re: Solar Energy, A Complement To FTA by isangjohnson: 7:33am On Dec 14, 2022 |
earthrealm:The hybrid limit has been confirmed as stated in the previous page (120v to 500v). 7S2P x 450/48 is 131A which is greater than the Max Mppt charging current of 100A. 11S1P will give out 113A which is in considerable range as losses may step it down to about 95A. Fortunately, I'm yet to buy the additional panels hence my reason for asking all these questions. I've bought the 5kw hybrid inverter already and I'm planning to buy additional 450w PVs to add to the existing 9 pcs of 450w before going into upgrading proer. |
Re: Solar Energy, A Complement To FTA by isangjohnson: 7:33am On Dec 14, 2022 |
durodee:Thanks for your advice sir |
Re: Solar Energy, A Complement To FTA by jonescosmos(m): 7:55am On Dec 14, 2022 |
Yes, TechLand is a trusted dealer, I transacted with them yesterday, communications was with the MD directly. They shipped out my 26pcs of 600w Canadian Solar panels yesterday fingers crsooed I would recieve them soon enough. And guess what, The man is from my state, hehehehe, small world. TechGeek777: 2 Likes |
Re: Solar Energy, A Complement To FTA by isangjohnson: 7:55am On Dec 14, 2022 |
Oshomo12:The range and every other parameters has been confirmed and stated here in the previous page. |
Re: Solar Energy, A Complement To FTA by Sapiosexuality(m): 7:56am On Dec 14, 2022 |
Pojomojo:Someone once posted some sites on this and I can still remember GennexTechnologies dot com. Try and let us know 1 Like 1 Share |
Re: Solar Energy, A Complement To FTA by isangjohnson: 8:03am On Dec 14, 2022 |
Thanks everyone for your advice. I'll go for 10S1P configuration. |
Re: Solar Energy, A Complement To FTA by jonescosmos(m): 8:12am On Dec 14, 2022 |
This is the best setup for you as per the MPPT of 500V Max ooo. You had mentioned 12pcs of PVs, please make sure you aren't gonna be setting up 12s of this PVs to this system. You might fry it. If you must use up all the 12 PVs, 6s2p is the way to go. isangjohnson: |
Re: Solar Energy, A Complement To FTA by jonescosmos(m): 8:35am On Dec 14, 2022 |
Please take a look at the attached pictures. 10s, 12s and 6s2p configs. Based on your Vmp and Imp. isangjohnson:
|
Re: Solar Energy, A Complement To FTA by jonescosmos(m): 8:44am On Dec 14, 2022 |
Just to clarify on this Max Amps, the Hybrid rated at 100A means that's the max it can suck out of a the input Amps supplied, So if you have a PV of 131A comming in, remember that the PV cannot supply if there is no demand. So even if the Inverter demands 100A of it's capacity from the PV, the rest 31Amp is not gonna be supplied. This is different from telling your Inverter to charge a battery rated 100A at 131A or a battery rated 60A at 100A, of course it will fry the battery eventually. But for Voltage, don't push your luck above the system ratings. isangjohnson: |
Re: Solar Energy, A Complement To FTA by Namzy(m): 8:57am On Dec 14, 2022 |
jonescosmos:Also max voltage is different from working voltage range. I've seen some mppt at 450v. 1 Like |
Re: Solar Energy, A Complement To FTA by Namzy(m): 8:59am On Dec 14, 2022 |
isangjohnson: I will reconfigure and make sure it doesn't exceed 450v. Your panels can exceed Voc on some certain cold days so having them near 500v is also risky |
Re: Solar Energy, A Complement To FTA by jonescosmos(m): 9:17am On Dec 14, 2022 |
Very correct Namzy: |
Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 1:11pm On Dec 14, 2022 |
2pcs of 15kwh 48v felicity lithium battery. 1pcs of 5kva 48v Growatt hybrid inverter ES All ready for delivery to port harcourt. Call/WhatsApp me on 08168986461. 1 Like
|
Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 1:14pm On Dec 14, 2022 |
15kwh 48v felicity lithium batteries still available, #1,600,000. Call/WhatsApp me on 08168986461
|
Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 1:15pm On Dec 14, 2022 |
220AH 12v Luminuos tubular batteries available, #170,000. Call/WhatsApp me on 08168986461
|
Re: Solar Energy, A Complement To FTA by isangjohnson: 1:21pm On Dec 14, 2022 |
Namzy:Thanks for drawing my attention to this. |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 2:07pm On Dec 14, 2022 |
isangjohnson: Ok, most smart hybrids will throttle the current if its beyond its max spec, its usually exceeding Voc that causes outright damage. Dep3nding on your risk tolerance, you can try 7s2p and see what happens. The 134amps you calculated wud only occur at optimum inclination and sunlight...which in real life rarely happens for longer than 5mins bursts. If you wanna play it safe, just do your 11s1p and call it a day, or alternatively if you want to maximize everything consider buying a cheap standalone cc like powmr and 2 more panels. So u run 3s1p on the cc and 11s1p on the hybrid |
Re: Solar Energy, A Complement To FTA by isangjohnson: 2:48pm On Dec 14, 2022 |
earthrealm:The alternative idea seems good but instead of buying another standalone CC, can my Morningstar Mppt CC with 60A max input current, 150Vdc max input voltage with operating voltage range of 10v to 72v handle this job? |
Re: Solar Energy, A Complement To FTA by TSHIRT2: 4:20pm On Dec 14, 2022 |
[quote author=TSHIRT2 post=119134647]Good evening all,which of the configuration is best for 6 pieces of 300w panel in a 24v system with 60amp epever charger controller, 3s2p or 2s3p. Anyone to my rescue |
Re: Solar Energy, A Complement To FTA by kuss: 4:38pm On Dec 14, 2022 |
Please connect me with someone that can help me repair my pulse repair charger It refused to come on since yesterday Cheked the fuse is still intact 1 Like |
Re: Solar Energy, A Complement To FTA by Pojomojo: 5:18pm On Dec 14, 2022 |
Pojomojo:*3kw 24volt Hybrid Inverter Setup + Solar* 1. 3kw 24volt Hybrid inverter (80Amps MPPT) = #220,000 2. 12v 220AH battery 2pcs = #165,000 x 2 = #300,000 (Tubular battery) 3. 300watts Solar panels 6pieces (1.6kw) = #60,000 x 6 = #360,000 4. Solar mounting rails on roof and its accessories = #24,000 5. AC & DC Cables = #70,000 6. AC and DC breakers, MC4 connectors, Trunking, breaker box, Input AVS, DC Surge, ChangeOver. = #40,000 7. Logistics to site of work = Negotiable 8. Installation = #40,000 TOTAL = Please he reviewed and gave me the quote above. Please, your inputs will be appreciated. |
Re: Solar Energy, A Complement To FTA by mctfopt: 6:14pm On Dec 14, 2022 |
jonescosmos: Go Jinko, PVs are so good. In no distant future, I foresee the "Canadian solar treatment". People buying junk and sticking a Jinko solar tape on it. |
Re: Solar Energy, A Complement To FTA by jonescosmos(m): 6:34pm On Dec 14, 2022 |
WOW, I see, thanks for this info. mctfopt: |
Re: Solar Energy, A Complement To FTA by jonescosmos(m): 6:41pm On Dec 14, 2022 |
Perhaps you should be more transparent by naming the products he intends to supply to you. 1, Brand of Inverter (very important) 2, Brand of Battery (Also 165,000x2 is not = #310,000 or #300,000) 3, Brand of Solar panels (Also 300w x6 is not = 1.6kw) 4, Others are at your dicretion. Cheers. Pojomojo: |
Re: Solar Energy, A Complement To FTA by isangjohnson: 7:19pm On Dec 14, 2022 |
Pojomojo:Someone suggested previously here that the installer should put the names of various components he intends to buy for you. You may still come back to seek help and it may be too late then. I suggest you get everything right from the beginning so you can enjoy your investment. 3 Likes |
Re: Solar Energy, A Complement To FTA by jonescosmos(m): 7:27pm On Dec 14, 2022 |
Exactly isangjohnson: |
Re: Solar Energy, A Complement To FTA by vta2008: 8:38pm On Dec 14, 2022 |
toyeoye: Abeg why did you get a charge controller for your inverter? I have the famicare 5.5kva 24v inverter and it comes with internal pwm solar charge controller. |
(1) (2) (3) ... (1316) (1317) (1318) (1319) (1320) (1321) (1322) ... (1854) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: suretx(m), de3lar(m), Deesmo07 and 1 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 70 |