Re: Solar Energy, A Complement To FTA by samir101ng(m): 4:11pm On Jan 03, 2023 |
bigrovar: This !!! This power derating issue is also a point of concern apart from the intial cost of the inverter. With average temps over 30C even with the harmattan weather here in Abuja, your 5kva Victron inverter is essentially a glorified 3.7kva inverter. And at that price and performance, my wallet cannot justify such expenditure. I however tap into Bigbrovars grace to also buy Victron when the Lord blesseth my wallet. Egbon Niyi, please keep on preaching the blue gospel. Your ministry shall flourish together with Nigeria's GDP 2 Likes
|
Re: Solar Energy, A Complement To FTA by samir101ng(m): 4:19pm On Jan 03, 2023 |
NiyiOmoIyunade: Thank you Egbon Niyi for the feedback on this derating issue. My concern is can i run continuous loads over 4000w as an example above lets say 34C which is today's ambient temp for Abuja or will the inverter refuse to power the load ? I don't want to provide additional cooling for the inverter so it will be subjected to our average ambient temps. |
Re: Solar Energy, A Complement To FTA by christy99: 4:21pm On Jan 03, 2023 |
mangolpupa:thank you. I've reached out to him |
Re: Solar Energy, A Complement To FTA by emyfine08: 4:53pm On Jan 03, 2023 |
earthrealm:Can you assist on it? |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 5:19pm On Jan 03, 2023 |
mangolpupa: Warmth regards Happy new year Sir/Ma ! |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 6:07pm On Jan 03, 2023 |
emyfine08: Naah, best done by someone in your city, am not in lagos. indicate your city, perhaps someone in your city who can do it will come up, however be prepared to spend above 200k in parts, labour etc |
Re: Solar Energy, A Complement To FTA by TechGeek777: 6:17pm On Jan 03, 2023 |
NiyiOmoIyunade: |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 6:40pm On Jan 03, 2023 |
For items 2 and 3 it is best if you used a clamp meter to measure the startup surge and amps draw while the pump runs. This is safer for you as you won't break something by accident. Just clamp the live wire (only) supplying power to the pump and read the amps - if you happen to have an AC watt meter with CT coil, that can do the job and give you a direct watts reading TechGeek777: 1 Like |
Re: Solar Energy, A Complement To FTA by emyfine08: 6:45pm On Jan 03, 2023 |
earthrealm:Am not in Lagos Anambra State |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 7:12pm On Jan 03, 2023 |
Perhaps you may wish to consider the size of PV array and battery bank required to run a 3kW load sustained? If you had access to say a 10kVa el cheapo inverter that could run say 5,000w sustained would you choose to afford the required PV array and battery bank to run that 5,000w load safely and stably 24/7? Your example looks contrived to disparage a decent inverter but lacking a full view of the overall system design into which the inverter must fit. If you can shell out the cash for the necessary PV array and/or battery bank to support 3000w-5000w constant load run, then the cost of a Victron 5kVa multiplus would not bother you, it would be an opportunity to derive max value from your investment by leveraging all the value added features bundled with the inverter. samir101ng: 2 Likes |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 7:29pm On Jan 03, 2023 |
Please see my prior response [above] about proper system design and related considerations. The temperature derating behaviour is with respect to the internals of the inverter and not ambient At 25degC you can run 4,000w constant load and 5,000w for 30minutes. At 40degC you can run 3,700w constant load and ~4,500w for 30minutes. The peak loading can only be sustained until you trip the over temperature and/or overload limits and is intended for occasional bursts that equipment will present and not as standard design practice to overload the inverter. If indeed you were contemplating a 4,000w load run perpetually and you wish to exert no effort to keeping the inverter cool then you may be better served by the next large inverter size which I may add costs nearly twice as much or you could parallel 2x3kVa units after certifying they would sustain your desired loads samir101ng: 1 Like |
Re: Solar Energy, A Complement To FTA by gadgetplanetng: 9:08pm On Jan 03, 2023 |
I know this is on short notice, But I'd need someone experienced to come along for an energy audit by 10am tomorrow in Port Harcourt (Olu Obasanjo Rd). For a 10/20Kv system. |
Re: Solar Energy, A Complement To FTA by vta2008: 9:36pm On Jan 03, 2023 |
Sheisenough01: Mine is the 5.5KVA 24V version.....check the side of yours for the specs. The battery charge light finally went off after I installed 4 350w solar panels and a 15kva stabilizer. Till date the light never goes off UNLESS there's solar power and grid supply at the same time....very weird stuff. I don't know if the stabilizer is what is helping the light go off I just checked my user manual and 3.5kva as well as 5.5kva are 24V inverters. Your inverter is showing 13.5V instead of >24V. Maybe your installation wasn't done properly OR your model is the 1.5kva or 2.5kva 12v If you have the 5.5Kva model, it already comes with a PWM 24 charge controller. Hope the external charge controller isn't messing with it. Finally a few people here like NiyiOmoIyunade and isangjohnson have talked about batteries with fake ratings (180AH labeled as 220AH). Maybe na your situation *I reject am for you* I now handover to our Inverter Lords 2 Likes 1 Share |
Re: Solar Energy, A Complement To FTA by KOBOOPRINCE: 10:47pm On Jan 03, 2023 |
gadgetplanetng: Contact me I am in Port Harcourt @kobootech electrical on Facebook |
Re: Solar Energy, A Complement To FTA by Fapemz: 7:32am On Jan 04, 2023 |
Moneyyman: Go for our MPS range of portable LFP power solutions and just 600watt of solar. I will recommend MPS 3
|
Re: Solar Energy, A Complement To FTA by Moneyyman: 7:59am On Jan 04, 2023 |
How much is it? Fapemz: |
Re: Solar Energy, A Complement To FTA by mangolpupa: 8:31am On Jan 04, 2023 |
kiekie1: Happy New Year 2023 our Oga. Wishing you & household a better year ahead. 1 Like |
Re: Solar Energy, A Complement To FTA by Sheisenough01: 8:57am On Jan 04, 2023 |
vta2008: Thanks your response has helped a lot. This is the user manual attached. I've checked both sides of the inverter there is no specification written. A fake model maybe?
|
Re: Solar Energy, A Complement To FTA by mangolpupa: 9:04am On Jan 04, 2023 |
drizzypat: Assuming you bought the MusT inverter for 360k and the cost of repairing that board is nearing half of the cost (180k). I will be favorably disposed to getting a new "better" quality hybrid inverter than spend that much repairing the board. Reason is that there is no guarantee that board wont go bad again. If you ever decide to go for a new inverter, my advise is to make sure you are getting one with a good history of performance/service you can verify to an extent or even better from an authorized dealer if possible. Buying from an authorized dealer will have some advantages like some form of warranty or after sales service. Often times in our country, as a general statement, Items gets worse after visiting repair shops, so weigh your options wisely. More importantly find out what caused the last issue with the inverter: was it a surge or bad connection or what? Then what could you have done to stop it from happening should be the next question. If you don't identify the cause of the last mishap, even a repaired or new inverter will sooner or later go through the same issue. |
Re: Solar Energy, A Complement To FTA by gadgetplanetng: 10:29am On Jan 04, 2023 |
gadgetplanetng: So what is actually needed. There is an existing system, Su Kam 30kv 360v inverter with 30 225ah batteries and panels with Tristar controllers (not working) They need to 1. Be moved to a new location or 2. A quotation made for a new system at the new location with the old one decommissioned. |
Re: Solar Energy, A Complement To FTA by Ajanidokun: 10:43am On Jan 04, 2023 |
Good day, I want to sell my complete 1kva inverter system. It comprises of the following: Available by Feb 5th 1kw 12v must hybrid inverter (VPM) - 50Amps inbuilt MPPT - 20amps max AC charging - lithium charging profile -manual is available 12V 200AH LifePO4 battery -100A BMS -coupled by Pelton Technology - still under warranty Solar Panels -260watt Bestcom solar panel (2pcs) Others 6mm wires, breaker and changeover Price - 440k Optional 1pcs Qasa AC/DC fan --15k Location is Abeokuta Contact 080-52-six-five-1572
|
Re: Solar Energy, A Complement To FTA by drizzypat: 11:13am On Jan 04, 2023 |
mangolpupa: Wow thanks a lot . Gen actually bought about the issue As I was charging my battery(which I normally do) Rn if I try to get another I was thinking of Ivm felicity 5kva And not connect generator to it The reason I did at first was due to not enough panels . I will have to mange d panels then for now and jst don't use gen anymore on it. |
Re: Solar Energy, A Complement To FTA by mangolpupa: 11:50am On Jan 04, 2023 |
drizzypat: Brother, I am not an expert but your Generator is not your problem. All hybrids from my humble knowledge allow grid (NEPA) or Generator pass through to charge the batteries depending on the inverter operational mode you select. My thoughts would be to 1. check your electrically wiring from generator to the inverter is adequate and properly sized 2. Put in a safety device between your generator and the hybrid inverter that will manage the V/A coming into the inverter. Seniors in the house can advise you on these devices and what they're called. 3. I would do same for the PV solar panels source coming into the inverter too. Seniors in the house can advise you on these devices and what they're called. 4. "earth" or ground" your hybrid inverter panel if possible. This is my 2 kobo thoughts. |
Re: Solar Energy, A Complement To FTA by vta2008: 1:53pm On Jan 04, 2023 |
Sheisenough01: Looks like they use the same manual for all models. Check the carton too. Ask the seller what model he sold to you. Maybe it's on the receipt sef
|
Re: Solar Energy, A Complement To FTA by Fapemz: 3:12pm On Jan 04, 2023 |
Re: Solar Energy, A Complement To FTA by samir101ng(m): 3:59pm On Jan 04, 2023 |
From the recent comments i have been seeing a lot of people it seems are using their generators to charge their batteries using the inverters internal charger. While there is nothing inherently wrong with using a generator to charge your batteries with your inverter, you need to make sure certain safety precautions and parameters are set before blowing up certain components of your system. I would like to assume that majority of the members here are using a pure sine wave inverter which outputs a clean voltage of 220-230v 50hz to your appliances. However, it doesn't like the voltage fluctuations, frequency shifts and spikes that a lot of "some" peoples generators output thereby damaging their inverters. Your generators alternator must be outputting a steady voltage to the inverter. You need to check and ensure the voltage and frequency coming out of the output of your generator going to the inverter, some inverters will refuse to charge and reject such dirty voltages but ultimately will blow a component so lets be very, very careful with the types of generators we use for charging. Generators with the AVR (Automatic Voltage Regulator) function are designed to maintain a consistent voltage level, causing it to be less likely to damage sensitive equipment. Named brands like Honda, Thermocool, Sumec, Fireman etc have this AVR built in but confirm to be sure that the voltage is within specs and adjusted if necessary. 2 Likes |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 4:37pm On Jan 04, 2023 |
drizzypat: We have Sorotec and sunmart. Sunmart vmii 5.5kw 48v 100a hybrid inverter 500vdc - 375k Sunmart Vmii 3.5kw 24v 100a hybrid inverter 500vdc - 320k Sunmart Vmiii 3.5kw 24v 100a hybrid inverter 500vdc - 335k Sunmart Vmiii 5.5kw 48v 100a hybrid inverter 500vdc - 395k Sorotec Revo Vmii 5.5kw 48v 100a hybrid inverter 500vdc - 420k Sorotec Revo Vmii 3.5kw 24v 100a hybrid inverter 500vdc - 340k Sorotec 5.5kw 24v 100a hybrid inverter 500vdc parallel version (includes parrallel kit) - 450k Sorotec 3.5kw 24v 100a hybrid inverter 500vdc parallel version (includes parrallel kit)- 375k Sorotec Revo vmiii 5.5kw 48v 100a hybrid inverter 500vdc - 440k Sorotec Revo vmiii 3.5kw 24v 100a hybrid inverter 500vdc - 360k Powmr 3.2kva 24v 80a mppt hybrid inverter - 250k Powmr 3.5kva 24v 100a mppt hybrid inverter - 340k Powmr 5.5kva 48v 100a mppt hybrid inverter - 385k |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 4:49pm On Jan 04, 2023 |
drizzypat: 1) You can get Avr to protect your input. 2) have a change over to bypass the gen wen you are on Gen. This is if you are not sure the generator charges your inverter properly cos some generators can be quite terrible. 3) if you don't like the stress of switching your change over anytime you want to use gen, you can incorporate an Ats. This will automatically give you generator power without going into your inverter. We sell all items listed. Avr - 10k Avr 3 phase (4 pole) - 25k Ats(automatic transfer switch) 63a - 21k ( out of stock) Ats 100a - 24k Ats 125a - 25k Call/chat - 08117398294 |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 4:55pm On Jan 04, 2023 |
christy99: I meant your solar panels |
Re: Solar Energy, A Complement To FTA by mangolpupa: 6:22pm On Jan 04, 2023 |
House, does anyone have the experience or knowledge of using bentonite or merconite for earthing instead of charcoal and salt. if yes, what is your experience and how much did the bentonite cost per bag (how many kg is in a bag) or merconite cost per bag. If the house knows anyone who does please let me know. |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 6:41pm On Jan 04, 2023 |
Bentonite clay and marconite are good materials but you are better off with an industrial premixed GEM - see pic below This will give a very low resistance (highly conductive) and non-corrosive earth with stable and permanent readings for 30 years or more. Each GEM bag should cost under 25k at current prices. If anyone will cheap out and use charcoal then they should get the powder form or grind/pound the lumps into as fine/powdery form as they can manage. Salt leaches out of the install site as rainfall comes and goes every season and may also corrode the copper so I do not encourage the use - if you must use salt then test your soil resistivity and dose regularly. mangolpupa: 2 Likes
|
Re: Solar Energy, A Complement To FTA by mangolpupa: 7:15pm On Jan 04, 2023 |
NiyiOmoIyunade: Exactly why I decided to look "outside the box" , away from traditional coal & industrial salt combination. Do you know of GEM brand you can recommend? Can this be easily sourced from building material merchants, chemical merchants or ... |
(1) (2) (3) ... (1331) (1332) (1333) (1334) (1335) (1336) (1337) ... (1854) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: omonla5, kashman04(m), Peterlove11, Hero2t and 5 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 119 |