Welcome, Guest: Register On Nairaland / LOGIN! / Trending / Recent / New
Stats: 3,191,028 members, 7,942,719 topics. Date: Saturday, 07 September 2024 at 03:35 PM

Solar Energy, A Complement To FTA - Satellite TV Technology (1383) - Nairaland

Nairaland Forum / Entertainment / TV/Movies / Satellite TV Technology / Solar Energy, A Complement To FTA (2277150 Views)

UPS Back-up, Also A Complement To FTA / FTA Frequency / Cctv Installation A Complement To Fta And Solar Energy (2) (3) (4)

(1) (2) (3) ... (1380) (1381) (1382) (1383) (1384) (1385) (1386) ... (1802) (Reply) (Go Down)

Re: Solar Energy, A Complement To FTA by TechGeek777: 10:56pm On Mar 30, 2023
Trippledots:


41.3v x 4panels=165.2v < Felicity 195v so Yes, the Felicity should work fine with those specs and config

Thanks for your input.

I just read on YouTube from a user with this same 100A variant.

These were his comments about a year ago "The most you can connect is 3 series. I tried 4, it brought the fault code 21 . When open current got to 171 volt. I use 100amps", although he didn't state his VOC.

My question is will this calculated 4s 165.2v increase on any condition (hold/hot weather) or will it only decrease?

Secondly is there a way to know/get the maximum daily yield from these Felicity CC?
Re: Solar Energy, A Complement To FTA by Trippledots(m): 11:09pm On Mar 30, 2023
TechGeek777:


Thanks for your input.

I just read on YouTube from a user with this same 100A variant.

These were his comments about a year ago "The most you can connect is 3 series. I tried 4, it brought the fault code 21 . When open current got to 171 volt. I use 100amps", although he didn't state his VOC.

My question is will this calculated 4s 165.2v increase on any condition (hold/hot weather) or will it only decrease?

Secondly is there a way to know/get the maximum daily yield from these Felicity CC?

Well, nothing beats hard evidence from field most times. Find out what the error code means and be sure it's not maybe a bug or firmware issue correctable with a firmware upgrade...@bolded: Ideally that doesn't increase.
Re: Solar Energy, A Complement To FTA by Bambless1(m): 12:41am On Mar 31, 2023
Peterlove11:


If you can, add additional panel and connect 3s3p.
My setup was 8 270w initially and I rarely get above 1000w solar generation. I added a panel recently and change it from 2s4p to 3s3p. The peak instant generation has jumped up to around 1.8kw. That's more than 50% increase
Thanks A Lot Senior man, in a situation where I can't get the additional panel, can I still use it in 2s4p for the mean time,
Re: Solar Energy, A Complement To FTA by Bambless1(m): 12:43am On Mar 31, 2023
Dam5reey:


8 is Good starting point if Grid is mostly available and if you don't deep discharge your batteries, I would recommend 12 as minimum.
Grid is average, in a 2s4p connection right?
Re: Solar Energy, A Complement To FTA by TechGeek777: 1:23am On Mar 31, 2023
Trippledots:


Well, nothing beats hard evidence from field most times. Find out what the error code means and be sure it's not maybe a bug or firmware issue correctable with a firmware upgrade...@bolded: Ideally that doesn't increase.


Thanks, any way to know total daily yield?
Re: Solar Energy, A Complement To FTA by Peterlove11: 3:01am On Mar 31, 2023
Bambless1:
Thanks A Lot Senior man, in a situation where I can't get the additional panel, can I still use it in 2s4p for the mean time,

Yes you can

1 Like

Re: Solar Energy, A Complement To FTA by Bambless1(m): 8:15am On Mar 31, 2023
Peterlove11:


Yes you can
💖💖
Re: Solar Energy, A Complement To FTA by Ma3ca4: 9:26am On Mar 31, 2023
30 amps pwm charge controller available for sale @ give away price of 10,000
@ first come first serve
Re: Solar Energy, A Complement To FTA by zeestone99(m): 9:38am On Mar 31, 2023
Era solar 380w solar panel - 120k
Era solar 450w solar panel - 136k
Era solar 550w solar panel - 175k
Era solar 660w solar panel - 205k
Jinko 380w solar panel - 125k
Jasolar 410w - 131k
Longi 450w - 143k
Longi 545w - 177k

Sunmart vmii 5.5kw 48v 100a hybrid inverter 500vdc - 375k

Sunmart Vmii 3.5kw 24v 100a hybrid inverter 500vdc - 320k

Sunmart Vmiii plus 3.5kw 24v 100a hybrid inverter 500vdc - 340k

Sunmart Vmiii plus 5.5kw 48v 100a hybrid inverter 500vdc - 395k

Sorotec Revo Vmii 5.5kw 48v 100a hybrid inverter 500vdc - 420k

Sorotec Revo Vmii 3.5kw 24v 100a hybrid inverter 500vdc - 340k

Sorotec 5.5kw 48v 100a hybrid inverter 500vdc parallel version (includes parrallel kit) - 460k

Sorotec 3.5kw 24v 100a hybrid inverter 500vdc parallel version (includes parrallel kit)- 380k

Sorotec Revo vmiii 5.5kw 48v 100a hybrid inverter 500vdc - 440k

Sorotec Revo vmiii 3.5kw 24v 100a hybrid inverter 500vdc - 360k

Powmr 3.2kva 24v 80a mppt hybrid inverter - 250k

Powmr 3.5kva 24v 100a mppt hybrid inverter - 340k

Powmr 5.5kva 48v 100a mppt hybrid inverter - 385k

Snadi 3.5kva 24v inverter wall mount (transformer) - 275k

Snadi 5.5kva 24v inverter wall mount (transformer) - 350k

Snadi 5.5kva 48v inverter wall mount (transformer) - 350k

Epever tracer 60a mppt charge controller - 175k

Epever tracer 100a mppt charge controller - 280k

Must 100a mppt solar charge controller - (out of stock)

Must 60a mppt solar charge controller - 130k

Must 80a mppt solar charge controller - 140k

Fangpusun flexmax 80a mppt charge controller - 270k

Fangpusun flexmax 60a mppt charge controller - 200k

Fangpusun 50a 12/24v - 90k

40amps mppt lumiax Bluetooth controller - 80k

60amps lumiax Bluetooth mppt controller - 145k

60amps 12/24/36/48v powermr mppt - 80k

Greenpole 48v 100ah lithium battery - 930k

Avr/current limiter 60a (Tomzn) - 10k

Avr/current limiter 63a 4pole (tomzn) - 25k

Change over breaker/MTS (tomzn) - 6.5k

Change over breaker/MTS 4pole (tomzn) - 15k

DC SPD 500v - 9k

DC spd 1000v (tomzn)- 10k

Ac spd 385v - 8k

Ac spd 275v (tomzn) - 9k

Ac spd 4 pole - 17k

DC Voltmeter (5v- 120v ) - 2k

Watt meter - 15k

Mc4 connectors - 650

Mc4 y connector 2 in 1 - 2.8k

Mc4 y connector 3 in 1- 4k

Mc4 y connector 4 in 1 - 8k

Programmable timer 15a UK pkug - 9k

Programmable timer 25a - 9k

solar DC fuse holder 1 pole (tomzn) - 3k

Solar DC fuse holder 2 pole (tomzn)- 5.5k

Solar DC fuse (10a/16a/20a/25a/30a) - 2k

DC breaker 10a 600v double pole (tomzn)- 6.5k

DC breaker 16a 600v double pole (tomzn) - 6.5k

DC breaker 20a 600v double pole (tomzn) - 6.5k

DC breaker single pole (32-63a) - 3k

DC breakers double pole 63a - 5k

DC breaker double pole 100a - 9k

Dc breaker double pole 125a - 10k

DC breaker double pole 100a (tomzn)- 10k

Dc breaker double pole 125a (tomzn)- 13k

Dc breaker mccb 250a double pole - 29k

Ac breaker double pole 10a (Tomzn)- 4k

Ac breaker double pole 16a (Tomzn)- 4k

Ac breaker double pole 32a (Tomzn)- 4k

Ac breaker double pole 63a (Tomzn)- 4k

Ac breaker double pole 10a (Chint)- 4k

Ac breaker double pole 16a (Chint)- 4k

Ac breaker double pole 32a (Chint)- 4k

Ha02 battery balancer - 35k

Automatic transfer switch (ATS) 63a (tomzn) - 21k (out of stock)

Automatic transfer switch (ATS) 100a (tomzn) - 26k

Automatic transfer switch (ATS) 125a (tomzn) - 26k

6 in 1 Ac display meter ( watts, voltage,kWh,amps, freq, power factor) - 15k

6way breaker enclosure - 3.5k

9 way breaker enclosure - 4.5k

12way breaker enclosure - 5k

DM for other items.

Call/chat - 08117398294

Or

Visit https://mazinegroup.com/shop to order online.

Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 10:05am On Mar 31, 2023
400w Qcell solar panels available, #95,000. Call/WhatsApp me on 08168986461

Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 10:08am On Mar 31, 2023
5kw 48v MUST hybrid inverter available, #320,000. Call/WhatsApp me on 08168986461

Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 10:10am On Mar 31, 2023
15kwh 48v felicity LBPR lithium battery available, #1,500,000. Call/WhatsApp me on 08168986461

Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 10:11am On Mar 31, 2023
15kwh 48v felicity LPBF lithium battery available, #1,700,000. Call/WhatsApp me on 08168986461

Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 10:12am On Mar 31, 2023
220Ah 12v super speed tubular battery available, #135,000. Call/WhatsApp me on 08168986461

Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 10:15am On Mar 31, 2023
2.5kva - 10kva felicity IVPS inverters available.

Call/WhatsApp me on 08168986461

Re: Solar Energy, A Complement To FTA by Trippledots(m): 2:39pm On Mar 31, 2023
TechGeek777:


Thanks, any way to know total daily yield?

I really don't know about that aspect for the product.
Re: Solar Energy, A Complement To FTA by earthrealm(m): 5:13pm On Mar 31, 2023
TechGeek777:


Thanks, any way to know total daily yield?

it doesnt show it, thats why i dont like the felicity CC. someone has described an alternate cumbersome method to install a 3rd party device for the data logging. felicity no try, for a 100k device...e supz get. data logging, if na 60k powmr wey no get am, its a bit understandable

1 Like

Re: Solar Energy, A Complement To FTA by TechGeek777: 10:09pm On Mar 31, 2023
Trippledots:


I really don't know about that aspect for the product.

Okay
Re: Solar Energy, A Complement To FTA by TechGeek777: 10:13pm On Mar 31, 2023
earthrealm:


it doesnt show it, thats why i dont like the felicity CC. someone has described an alternate cumbersome method to install a 3rd party device for the data logging. felicity no try, for a 100k device...e supz get. data logging, if na 60k powmr wey no get am, its a bit understandable

The 100A is about 150k.

Please can you tell the person maybe I can read it up.

Or if you know of any 80A with 180-190vdc that log daily harvest within the price range of 150k max kindly recommend.
Re: Solar Energy, A Complement To FTA by zeestone99(m): 10:58pm On Mar 31, 2023
TechGeek777:


The 100A is about 150k.

Please can you tell the person maybe I can read it up.

Or if you know of any 80A with 180-190vdc that log daily harvest within the price range of 150k max kindly recommend.

Only affordable cc I know is 60a
Re: Solar Energy, A Complement To FTA by TechGeek777: 3:11am On Apr 01, 2023
zeestone99:


Only affordable cc I know is 60a

Okay
Re: Solar Energy, A Complement To FTA by Oshomo12(m): 8:26am On Apr 01, 2023
Trippledots:


Is bolded referring to peak instantaneous yield or total yield for a day? Because the later should be in watt-hour units. I just want it to be clear for readers.

Peak u will get after sometimes. Those panels' watts decrease over time and it's rapid.

So the total yield for the day will be grossly affected.

Sorry for late response

1 Like

Re: Solar Energy, A Complement To FTA by Functionalsol: 2:30pm On Apr 01, 2023
15kva 48V Victron Energy Quattro inverters available for sale in Lagos.

Re: Solar Energy, A Complement To FTA by Alienwarfare: 12:10am On Apr 02, 2023
My inverter started showing this and it is no longer changing from the grid

Re: Solar Energy, A Complement To FTA by ewizard1: 5:48am On Apr 02, 2023
ewizard1:
3pcs Used Trina Solar 200W Solar Panels + 1pc used 60A PowMr CC available for sale.

Location : Isolo, Lagos.

*** SOLD ***

1 Like

Re: Solar Energy, A Complement To FTA by viperVIP: 1:03pm On Apr 02, 2023
Check behind the inverter, you should find a breaker controlling the grid input, it has tripped and you should switch it back on.

Alienwarfare:
My inverter started showing this and it is no longer changing from the grid
Re: Solar Energy, A Complement To FTA by Dishtech(m): 8:43am On Apr 03, 2023
TechGeek777:


The (Voc): 41.30V.
Full Specs ==>
Maximum Power(Pmax): 380W
Maximum Power Voltage (Vmp): 34.74V
Maximum Power Current (Imp): 10.94A
Open-circuit Voltage (Voc): 41.30V
Short-circuit Current (Isc): 11.68A

On the other hand there's a 100A Felicity CC with below details,
Max Pv Input Voltage = 195V
PV Array MPPT Vol Range = 160-170V

My question now is, can Felicity 100A with above spec take the 8 panels using 4s2p config?

Or should I use Techfine 60A/80A with (Max PV Voltage: 150V) and go for 9 panels using 3s3p config?

Please I need the one that will produce optimally so I know the total number of panels to purchase and the exact CC to go for.
Forget about the 195v written on the Felicity charge controller. Don't give it input voltage more than 125v or else it will bring out fault light at every peak generation.
Since your VOC is 41.30v so I recommend 3s i.e 3x41.3= 123.9v.
Also since your charge controller is 100A,
At 48v the maximum solar panels used should not be more than 4800watts,
At 24v the maximum solar panels used should not be more than 2400watts.
At 12v the maximum solar panels used should not be more than 1200watts.
So if your battery system 48v I will advice you buy one more panel to make it 3s3p, if the system is 24v or12v your panel is more than the capacity of your charge controller if properly installed.

1 Like

Re: Solar Energy, A Complement To FTA by bbally: 9:48am On Apr 03, 2023
At 12v the maximum solar panels used should not be more than 1200watts.
So if your battery system 48v I will advice you buy one more panel to make it 3s3p, if the system is 24v or12v your panel is more than the capacity of your charge controller if properly installed.[/quote]

Please, does this means that a panel array in 48v connection CANNOT BE USE TO CHARGE A 12V system with a POWMR 60A for instance
Re: Solar Energy, A Complement To FTA by Dishtech(m): 10:14am On Apr 03, 2023
bbally:

At 12v the maximum solar panels used should not be more than 1200watts.
So if your battery system 48v I will advice you buy one more panel to make it 3s3p, if the system is 24v or12v your panel is more than the capacity of your charge controller if properly installed.

Please, does this means that a panel array in 48v connection CANNOT BE USE TO CHARGE A 12V system with a POWMR 60A for instance
If the system was for 48v and the panels total watts is more than 750watts at good installation and optimal generation it will affect your charge controller
Re: Solar Energy, A Complement To FTA by bbally: 10:45am On Apr 03, 2023
Dishtech:

If the system was for 48v and the panels total watts is more than 750watts at good installation and optimal generation it will affect your charge controller

So, a mppt charge controller cannot convert the 48v to 12v for better charge and carry more load without depleting the battery percentage.
Re: Solar Energy, A Complement To FTA by Dishtech(m): 12:16pm On Apr 03, 2023
bbally:


So, a mppt charge controller cannot convert the 48v to 12v for better charge and carry more load without depleting the battery percentage.
Don't get me wrong! I said your initial 48v system configuration can be used to charge the battery if;
1. The total wattage of your system is not more than 750watt since your charge controller is 60A

There are two different things! you misunderstood!
He was asking about configuration of 8 pieces of 380watt panels totalling 3040watts on a 100A Felicity charge controller with the inscription 195V Max. VOC. Which I advised that he should get 380w to be able to configure 3s3p if his battery system is 48v, but if his battery system is 24 will reduce his panels by one to configure 3s2p or 2s3p.
Note that every charge controller has a maximum solar power it can accommodate. Since your charge is 60A at 12v system you will need not more than 750w panels.

1 Like 1 Share

Re: Solar Energy, A Complement To FTA by TechGeek777: 1:26pm On Apr 03, 2023
Dishtech:

Forget about the 195v written on the Felicity charge controller. Don't give it input voltage more than 125v or else it will bring out fault light at every peak generation.
Since your VOC is 41.30v so I recommend 3s i.e 3x41.3= 123.9v.
Also since your charge controller is 100A,
At 48v the maximum solar panels used should not be more than 4800watts,
At 24v the maximum solar panels used should not be more than 2400watts.
At 12v the maximum solar panels used should not be more than 1200watts.
So if your battery system 48v I will advice you buy one more panel to make it 3s3p, if the system is 24v or12v your panel is more than the capacity of your charge controller if properly installed.

Thanks for your input.

(1) (2) (3) ... (1380) (1381) (1382) (1383) (1384) (1385) (1386) ... (1802) (Reply)

FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread

Viewing this topic: 1 guest(s)

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 54
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.