Re: Solar Energy, A Complement To FTA by ewizard1: 10:49am On Dec 26, 2023 |
dollarnaira:And what I say is "if you match with exact rating or more of another mosfet" it should work with ALL nverters. It's not like there's a sense pin or signal from the mosfet the inverter use to check the replaced one. Once the installed resistor can fully turn on and drain the mosfet according to the frequency the mosfet are driven, and the mosfet can handle the power they're installed for, the inverter can not tell if the mosfet inside it is Model X or Y Resistance, D/SCapacitance, Rise Time, etc. Match these closely and replacement should work. 2 Likes |
Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 11:42am On Dec 26, 2023 |
Merry Christmas and a prosperous new year in advance from all of us @Manuel Solar Energy Enterprise
|
Re: Solar Energy, A Complement To FTA by lovediehatelive(m): 5:18pm On Dec 26, 2023 |
Please which rechargeable fan will you suggest for me? If it can be possible to charge it with USB, it will be good. If not please which one would you suggest |
Re: Solar Energy, A Complement To FTA by kristien4(m): 5:32pm On Dec 26, 2023 |
@everyone, can an inverter with inbuilt Ac charger, and an external MPPT charger be connected to same battery to charge at thesame time... will it overcharge/spoil the battery... since both will be charging same time.?? |
Re: Solar Energy, A Complement To FTA by Obnoxious2001(m): 5:39pm On Dec 26, 2023 |
kristien4:No. Both unit has voltage and current regulation abilities. 1 Like |
Re: Solar Energy, A Complement To FTA by Drgreatone: 6:01pm On Dec 26, 2023 |
I av come again with my curiosity. How do u determine the wire guage from solar panel to charge controller. Gone through different sites and seeing different recommendation. Someone recommended 10mm for use wit 800watts panel that 4mm wud be too small yet google gave a max volt/amps of 1000/36 for a 4mm double core wire. Distance is about 5 to 6m. Thank you for ur kind responses |
Re: Solar Energy, A Complement To FTA by odimbannamdi(m): 6:48pm On Dec 26, 2023 |
kristien4: This is even recommended, as long as both devices (the inverter charger and MPPT controller) won't charge the battery above its recommended max voltage. But the inbuit charger would most times stop charging at 13.5 or even lower, then the controller will charging up to 14.0 and above, as set. 1 Like |
Re: Solar Energy, A Complement To FTA by odimbannamdi(m): 6:50pm On Dec 26, 2023 |
Drgreatone: If you can afford 10mm2, perfect. Otherwise, 6mm2 is good too. |
Re: Solar Energy, A Complement To FTA by Queed: 7:02pm On Dec 26, 2023 |
dollarnaira: It works with all inverters bro, and generally all power converters. Once you can get a matching FET, or even better (voltage, current, on resistance, gate capacitance, rise time etc..) rating, it will definitely work. The major problem with repaired electronics is that the root cause is often ignored (did something not behave as it was designed to that made the FET go bad?) , or the damage to to FET had resulted to a slight damage of another device (eg. The FET driver), just changing the FET with the same or similar type in either of this case will definitely be a temporary solution. 4 Likes |
Re: Solar Energy, A Complement To FTA by Obnoxious2001(m): 7:07pm On Dec 26, 2023 |
Drgreatone:1.For every electrical system, your aim should be to have a voltage drop of Less than (<3%). This is the reason why on this forum, some people have complained of their submersible pumps consuming more power than expected. 2. Your ampacity/current from your solar panels (every wire has an ampacity chart you can check it out). If you have a low voltage and a higher current, the more thicker cables you require and vice versa. I think this is basically all I can contribute on this 1 Like |
Re: Solar Energy, A Complement To FTA by Drgreatone: 7:11pm On Dec 26, 2023 |
odimbannamdi:Thank you sir. I used to think 10mm2 is an overkill for such small system? But then, is the 4mm a bad choice though? Do u av a chart or something which I can use and compare. Different things abound in google and its difficult knowing which is right unless one has the basic knowledge. |
Re: Solar Energy, A Complement To FTA by kristien4(m): 7:15pm On Dec 26, 2023 |
odimbannamdi:Thanks |
Re: Solar Energy, A Complement To FTA by Drgreatone: 7:15pm On Dec 26, 2023 |
Obnoxious2001:Thank you. Do u have a wiring chart i can use? Panels are connected in series so sud at optimum conditions be getting abt 64v wit about 12amps? Same panel size in 2 different installations having 2kva12v and 4.2kva24v hybrid inverter with both 4mm2 wires coming from the panel. Yet the 4.2 gets higher solar volt input abt 55v compared to abt 30 in the 2kva. |
Re: Solar Energy, A Complement To FTA by kristien4(m): 7:15pm On Dec 26, 2023 |
Obnoxious2001:Thanks 1 Like |
Re: Solar Energy, A Complement To FTA by lovediehatelive(m): 7:59pm On Dec 26, 2023 |
bbeckky: Please Pardon my curiosity o. This one I'm seeing thunder there, hope it didn't directly strike your device? And please what should one do to protect solar system against thunder |
Re: Solar Energy, A Complement To FTA by temizeee(m): 11:01pm On Dec 26, 2023 |
dollarnaira:i see shades coming through for the panel…. The positioning seems off |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 11:08pm On Dec 26, 2023 |
XMAS FLASH SALES!! HURRY NOW!!! High quality Gizmo solar panel 380W mono 108 half cell ..... Minimum order : 4 units upward. Quantity below 4 units ... 90k See attached picture below for nameplate details. Contact, Smartcell global services CALL LINE::::: 081-350-31951 WHATSAPP::: 081-703-85620
|
Re: Solar Energy, A Complement To FTA by mctfopt: 10:56am On Dec 27, 2023 |
mikeayus: I may be biased, but I'll say it is PowMr. This is because I have a friend that was having so many issues with his Felicity charge controller, but when he changed to PowMr, the problem disappeared. 1 Like |
Re: Solar Energy, A Complement To FTA by dollarnaira: 11:34am On Dec 27, 2023 |
temizeee:He was in a tight corner Your position is different The idea is the point |
Re: Solar Energy, A Complement To FTA by mikeayus(m): 2:26pm On Dec 27, 2023 |
mctfopt: Okay,thanks for this response. |
Re: Solar Energy, A Complement To FTA by gadgetplanetng: 4:25pm On Dec 27, 2023 |
Get a good sachet inverter I replaced a 1.5kv Schneider Homaya (that has been with Schneider since July) with one and the difference is clear. Battery lasts longer, less wahala. bbeckky: |
Re: Solar Energy, A Complement To FTA by tsiriman(m): 4:32pm On Dec 27, 2023 |
jonescosmos: Please where did you order these 8kW from? Did you order directly from them or you ordered through a 3rd party? |
Re: Solar Energy, A Complement To FTA by tsiriman(m): 4:35pm On Dec 27, 2023 |
gadgetplanetng: Which one be sachet inverter again? |
Re: Solar Energy, A Complement To FTA by Ferdiwar: 5:34pm On Dec 27, 2023 |
10mm for 800w is an over kill. 4mm is ok for it especially if you're doing more of voltage than current. Some inverters manufacturers are more doing inverters with higher PV voltage and less current with recommendations of 4mm from the Solar panels to the inverter. Drgreatone: |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 6:53pm On Dec 27, 2023 |
First you look at how you are arranging your solar panels in series and parallel. Say you had 4 units of 550w panels in 2S2P, it would call for a different cable gauge than if you had them in 4S over thesame distance. So you look at the max amps your panel will generate - in the 550w panel case about 13.5a per panel so if you had a 2S2P arrangement you would be sending 26a from solar panel to charge controller - that calls for a 6mm2 cable as minimum gauge to carry that 26a then to have a less than 3% voltage drop you may need to upsize to 10mm2 (depends on distance and you use a voltage drop vs distance chart for this). If you were setting same panels in 4S for a max amps of 14a but much higher voltage then a 6mm2 cable would be perfectly fine even across a relatively large distance (again the charts will tell you minimum cable gauge to maintain X% voltage drop over X distance). In this 4S config you could even get away with 4mm2 cable but I would not recommend. This above is the general science - for your 800w situation how many panels do you have? What are the panel VmP and lmp (current) and how do you plan to arrange the panels? 2 in series then 2 in parallel or 4 in series? We can know your exact cable gauge needed if you answer these questions. Drgreatone: 1 Like |
Re: Solar Energy, A Complement To FTA by Drgreatone: 7:13pm On Dec 27, 2023 |
Ferdiwar:Thank you sir |
Re: Solar Energy, A Complement To FTA by Drgreatone: 7:20pm On Dec 27, 2023 |
NiyiOmoIyunade: Thank you boss. Its just 2 415watt panels with 32v and abt 13amp connected in series. Used a 4mm double core wire. Saw that it can take up to 1000v and abt 30amps online, just needed ppl's personal experience/choice. |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 7:38pm On Dec 27, 2023 |
The online voltage drop calculators say that you are fine. If your transmission distance increased more than 6m one way, the answer could change quickly. Drgreatone: 1 Like
|
Re: Solar Energy, A Complement To FTA by Drgreatone: 10:56pm On Dec 27, 2023 |
NiyiOmoIyunade:Thank you sir |
Re: Solar Energy, A Complement To FTA by bbeckky: 10:23am On Dec 28, 2023 |
mctfopt:Actually why I kept returning it to him is because he fixed the board for 45k and I thought I should be able to get value for that money. I told him to change the board actually because it seems the board he used is t a match. |
Re: Solar Energy, A Complement To FTA by obitobe: 1:48pm On Dec 28, 2023 |
Good day people, please i want to find out if Yohako hybrid inverter especially the 3.5kva/24v has that feature of remote monitoring. I see it has a rs323 in the pack. i just want to be sure before proceeding to buy the wifi module. |
Re: Solar Energy, A Complement To FTA by Jefferyzz(m): 4:07pm On Dec 28, 2023 |
Stay away from yohako product. There are lots of substandard products under yohako umbrella, there no way u u can figure out the good one. This features u mentioned is on growatt, powmr, felicity, srne etc n price is budget as well. obitobe: 2 Likes |
(1) (2) (3) ... (1536) (1537) (1538) (1539) (1540) (1541) (1542) ... (1855) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: Scientheosopher(m), Queed and 3 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 76 |