Re: Solar Energy, A Complement To FTA by Adeolatunde(m): 3:57pm On Jan 31 |
Jefferyzz:Okay boss. |
Re: Solar Energy, A Complement To FTA by durodee(m): 4:24pm On Jan 31 |
I bought a rated 5.5 KVA 24v to serve a very unique need. It is not hybrid and seems light in weight for the said capacity. I wanted an inverter to carry my ACsx2 plus other domestic load during festivities when the whole house is full and there are many things going on at the same time. Obviously that will include fridge, washing machine and 1HP pumping machine. It has served the purpose well with no issues. I also use it a few times to charge my system with the national grid as I found it less sensitive to voltage fluctuations. ( I use a Servo stabilizer before inputting to the inverter) For my regular use I have a 3.5kva 24v Foresolar inverter. Can carry fridge and washing machine but NOT the pumping machine with other loads. adibo: 1 Like |
Re: Solar Energy, A Complement To FTA by Obnoxious2001(m): 4:25pm On Jan 31 |
Myself50:The first picture is a RCBO right |
Re: Solar Energy, A Complement To FTA by Alienwarfare: 4:49pm On Jan 31 |
I have 8 300w panels for my 48v system but my charge controller rarely reads above 400w. What connection should I do for the panels? |
Re: Solar Energy, A Complement To FTA by adrusa: 5:02pm On Jan 31 |
Alienwarfare: What charge controller do you have? How are your panels stringed and connected? What is the state of your battery when you wake up in the morning? Do you use NEPA to charge your batteries? A yield of 400W from a 2400W array is terrible. But, it may be perfectly normal if your battery is usually charged with NEPA and is full most of the time. |
Re: Solar Energy, A Complement To FTA by kristien4(m): 5:42pm On Jan 31 |
durodee:Whats the total wattage of your solar panels ? |
Re: Solar Energy, A Complement To FTA by kristien4(m): 5:55pm On Jan 31 |
Can an mppt charge controller output more amps than the connected solar panels can provide?. Like a charge contoller outputing 60amps from a 40amps or 30amps solar panel setup?? |
Re: Solar Energy, A Complement To FTA by Alienwarfare: 6:04pm On Jan 31 |
adrusa: What charge controller do you have? Felicity mppt 80a How are your panels stringed and connected? The formal installer did 2 series to 4 parallel but I just changed it to 4 series to 2 parallel What is the state of your battery when you wake up in the morning? Usually dead Do you use NEPA to charge your batteries? Yes when there is light but when there is no light and sun is shining bright it will still die 1 Like |
Re: Solar Energy, A Complement To FTA by ojesymsym: 6:14pm On Jan 31 |
No one here seems to mention the smart series of charge controllers from Demuda. Their charge controllers look very decent plus they are smart, have lithium profile and can be connected remotely via their app and the possibility of iOT I'd like to think. I presently use one of their small PWM and I am presently expecting a 60A MPPT. |
Re: Solar Energy, A Complement To FTA by JoeSef0(m): 6:18pm On Jan 31 |
Abeg mak una help me put mouth 😔 JoeSef0: |
Re: Solar Energy, A Complement To FTA by Puvo: 6:48pm On Jan 31 |
zeestone99: I’ll stay away from them then |
Re: Solar Energy, A Complement To FTA by JoeSef0(m): 7:18pm On Jan 31 |
What could be the issue here I noticed whenever I'm on inverter and I'm using my phone while plugged in, the phone touch start malfunctioning, even my laptop trackpad and touch also malfunction when plugged in on inverter.. this doesn't happen on gen or NEPA. Abeg who don experience this thing b4 PS: I just noticed if i turn off extension socket, the socket light doesn't go off totally until i unplug the socket |
Re: Solar Energy, A Complement To FTA by brightk(m): 7:22pm On Jan 31 |
JoeSef0:what kind of inverter are u using? |
Re: Solar Energy, A Complement To FTA by JoeSef0(m): 7:22pm On Jan 31 |
Sms sunmate 2kva brightk: |
Re: Solar Energy, A Complement To FTA by brightk(m): 7:34pm On Jan 31 |
JoeSef0:hmmm. Was it liie this the first day u installed?. There might be issues on your inverter |
Re: Solar Energy, A Complement To FTA by durodee(m): 7:37pm On Jan 31 |
1) 255wx6 Mono panels as 3s2P + 60amps Epever MPPT Cc 2) 180wx3 Poly panels in 3s +60 amps Powmr MPPT Cc 3) 100wx5 Thin film panels in 5p+30amp Epever MPPT Cc Connected to @15kwh of LiPO4 batteries kristien4: 1 Like |
Re: Solar Energy, A Complement To FTA by ojesymsym: 7:39pm On Jan 31 |
Start by checking your neutral connection. JoeSef0: |
Re: Solar Energy, A Complement To FTA by durodee(m): 7:41pm On Jan 31 |
Do you use the same socket for your equipment when on Nepa or inverter or do you have a seperate setup for your inverter? If a seperate setup check your connections and earthing. There is a bridge of wire somewhere. JoeSef0: |
Re: Solar Energy, A Complement To FTA by durodee(m): 7:42pm On Jan 31 |
Most likely culprit ojesymsym: |
Re: Solar Energy, A Complement To FTA by JoeSef0(m): 8:01pm On Jan 31 |
It's same setup I didn't do load selection or anything like that durodee: |
Re: Solar Energy, A Complement To FTA by JoeSef0(m): 8:02pm On Jan 31 |
It's a one week old installation, brightk: |
Re: Solar Energy, A Complement To FTA by ewizard1: 8:03pm On Jan 31 |
kristien4:Possible! Charge Controller can output 50v @ 60A if Solar panels gives 75v @ 40Amps. Same power. |
Re: Solar Energy, A Complement To FTA by brightk(m): 8:08pm On Jan 31 |
HAS anyone patronised techland. I got the contact here on this thread a long time ago but because no recommendations i didnt use them |
Re: Solar Energy, A Complement To FTA by adrusa: 8:47pm On Jan 31 |
Alienwarfare: Sounds like you do have a serious issue then. All these answers checked out well. You should certainly get more than what you are getting. You need someone truly knowledgeable to help you review the installation. One other quick thing that you can check is if your Charge controller is set to limit the charging current. |
Re: Solar Energy, A Complement To FTA by TechGeek777: 9:19pm On Jan 31 |
olopan: Does it mean it's better not to ground it if there's no arrestor close by? |
Re: Solar Energy, A Complement To FTA by TechGeek777: 9:20pm On Jan 31 |
kristien4:okay |
Re: Solar Energy, A Complement To FTA by TechGeek777: 9:21pm On Jan 31 |
isangjohnson: You dey ask good questions shall oh. Maybe one original pass the other |
Re: Solar Energy, A Complement To FTA by kristien4(m): 9:30pm On Jan 31 |
ewizard1:Thanks |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 11:27pm On Jan 31 |
durodee: lolz, I no sabi wetin sorotec do una. i have 4 sites with sorotec, with oldest going on 4yrs now...zero issues..maybe its the models you bought. i bought the mid range models back then 3 units of revo ii...the one with touchscreen and 1 unit revo E, all firing strong. the revo E sometimes has the float bug...other than that my experience with sorotec is great. which models give una problem? 2 Likes |
Re: Solar Energy, A Complement To FTA by mctfopt: 12:52am On Feb 01 |
brightk: They are cool. You can do business with 'em. |
Re: Solar Energy, A Complement To FTA by mctfopt: 1:03am On Feb 01 |
Adeolatunde: There is a seller here that sells variable output voltage charger here, Valto. https://www.nairaland.com/390522/solar-energy-complement-fta/1131#110684591 But if you don't like the charger due to cost or availability, you can buy a normal charger and get a variable DC to DC buck converter like this type from Konga with image attached below that can take a DC input (say a normal 12v charger's output) as input with variable DC output with you can use to do top balancing 1 Like
|
Re: Solar Energy, A Complement To FTA by Valentinooo: 7:36am On Feb 01 |
Anybody has an idea of the cost of installing thunder arrestor. I think I need one |
(1) (2) (3) ... (1561) (1562) (1563) (1564) (1565) (1566) (1567) ... (1822) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: 1 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 47 |