Welcome, Guest: Register On Nairaland / LOGIN! / Trending / Recent / NewStats: 3,208,114 members, 8,001,559 topics. Date: Wednesday, 13 November 2024 at 12:13 PM |
Nairaland Forum / Entertainment / TV/Movies / Satellite TV Technology / Solar Energy, A Complement To FTA (2384781 Views)
UPS Back-up, Also A Complement To FTA / FTA Frequency / Cctv Installation A Complement To Fta And Solar Energy (2) (3) (4)
(1) (2) (3) ... (1690) (1691) (1692) (1693) (1694) (1695) (1696) ... (1854) (Reply) (Go Down)
Re: Solar Energy, A Complement To FTA by mahkanjuh: 2:31pm On May 04 |
durodee: You have them for sale? |
Re: Solar Energy, A Complement To FTA by damilonya(m): 2:47pm On May 04 |
swagifted: Good one Pls, send me your WhatsApp number on damilonya@gmail.com. Thanks, Sir |
Re: Solar Energy, A Complement To FTA by mctfopt: 3:03pm On May 04 |
HeavenlyBang: Dang. I'm trying to see how I can wiggle my way out of Growatt's ES5000 22A maximum input current. |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 3:06pm On May 04 |
Now available Avr/current limiter with kwh(energy) display. Know how much energy you consume. Price - 18k Call/chat - 0.811739..8294
|
Re: Solar Energy, A Complement To FTA by JustCryptos: 3:12pm On May 04 |
Amador1: What exactly was your issue with the Jos guy? One of the cells of the battery I got from him 3 years ago has gone bad. He wants he to send the full bank back to Jos. I have not made up my mind yet because he is not responding to my WhatsApp messages (even though he is online) only calls. |
Re: Solar Energy, A Complement To FTA by HeavenlyBang(m): 3:36pm On May 04 |
mctfopt: Just connect in series... Also, unlike voltage, current needs to be drawn. Even if your setup is supplying 25A isc, your Growatt will only pull the 22A it's limited to. You still lose some power but not much, since it's not like you'll be getting isc anywhere near regularly. My SRNE has a max input of 13A but a 500v VOC, so I just ran my PVs in series. |
Re: Solar Energy, A Complement To FTA by xtremeidea(m): 3:45pm On May 04 |
zeestone99: Does it have wifi or an app for remote monitoring? |
Re: Solar Energy, A Complement To FTA by Amador1: 3:58pm On May 04 |
JustCryptos:If you check my previous posts, you will see the issue I’m having with my battery. I’m still waiting for the feedback from the guy he told me to go drop the battery with but you’re right, WhatsApp messages sent to him gets delivered but he doesn’t respond back to it. |
Re: Solar Energy, A Complement To FTA by Edrizz(m): 4:03pm On May 04 |
HeavenlyBang: Infact, I'm also at the Cross road on this subject matter, though it's already written on the manual that high ISC of the solar panel will not affect the inverter but my concern is that, why waste energy when I could get a panel with ISC of 13amps n below... abeg help share a panel with ISC less than 13amps |
Re: Solar Energy, A Complement To FTA by xtremeidea(m): 4:05pm On May 04 |
Hello Guys, has anyone tried this product from felicity? Any reviews? Does it work with all products.? This is not the USB version, it's comes with a serial and RJ45 connector. 1 Share
|
Re: Solar Energy, A Complement To FTA by mctfopt: 4:19pm On May 04 |
HeavenlyBang: Yeah, but I want to get close to that 6000w PV capacity. The best I could do is roughly 4500w. |
Re: Solar Energy, A Complement To FTA by kristien4(m): 4:27pm On May 04 |
mctfopt:Lol..same issue i had with my growatt 5000es, i could only use 4600w out of the 6000watts cos my panel voc don near 450v and if i parallel to drop voltage.. 22A isc wont allow. Anytime u find solution, let us know...Lol |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 4:33pm On May 04 |
xtremeidea: No sir |
Re: Solar Energy, A Complement To FTA by HeavenlyBang(m): 4:35pm On May 04 |
mctfopt: If we're being objective, you probably will never get the max output of your panels in Nigeria. When sun is out on full blast, temperatures also rise which then drops voltage. It's more likely that you get NOCT Pmax, which is around 77% of your panels' rated output. If you're getting around 20KWh daily from your 6000w setup, you're doing about as fine as you possibly can imo. If you absolutely need to get 6000w, then you just need to oversize your panels as much as you can while staying within the VOC limit of your inverter. Edrizz: Pretty much all the Jinko panels will serve you. 580W panel has about a max amperage of 13A. 1 Like |
Re: Solar Energy, A Complement To FTA by ceaser: 4:44pm On May 04 |
swagifted: I think I'm counting up to around 250 units solar panels on that sprawl of building. It may be more. Eachvoanel may not be less than 300w. I'm helplessly envious. Damn!
|
Re: Solar Energy, A Complement To FTA by mctfopt: 5:30pm On May 04 |
HeavenlyBang: The max you can get out of this 580w is 8 in series which is still 4640. Still far from 6000w. I want to go near to 6000w without need for an external charger controller. |
Re: Solar Energy, A Complement To FTA by odimbannamdi(m): 5:38pm On May 04 |
JustCryptos: Abeg, who's this Jos guy...you don't have to state his name in full and I won't quote the post so that it can be edited later |
Re: Solar Energy, A Complement To FTA by Oshomo12(m): 6:08pm On May 04 |
mctfopt: You may need to go for lower panel wattage, say, 255w Trina, voc 38v, ISC around 9a I think. You will be doing 12 in series and 2 set in parallel. 1 Like |
Re: Solar Energy, A Complement To FTA by odimbannamdi(m): 6:17pm On May 04 |
Dam5reey: Thanks for clarifying boss |
Re: Solar Energy, A Complement To FTA by TechGeek777: 6:27pm On May 04 |
odimbannamdi: https://www.nairaland.com/390522/solar-energy-complement-fta/1040#105037581 |
Re: Solar Energy, A Complement To FTA by TechGeek777: 6:30pm On May 04 |
Oshomo12: 38v * 12 Pcs = 456v still more than 450v, unless he connects 11s2p which should give him 418v |
Re: Solar Energy, A Complement To FTA by Penuelseun(m): 6:31pm On May 04 |
mctfopt:JA Solar 460w is around 11a
|
Re: Solar Energy, A Complement To FTA by ewizard1: 6:48pm On May 04 |
jonescosmos: That bar is a clamp. There are cells under it. Its how most battery designer holds their cells in place. I see lots of that. 1 Like |
Re: Solar Energy, A Complement To FTA by ewizard1: 6:50pm On May 04 |
Amador1: Can take a look at it if still interested. |
Re: Solar Energy, A Complement To FTA by ewizard1: 6:51pm On May 04 |
Valto:Nicely done. |
Re: Solar Energy, A Complement To FTA by Xanderone: 7:03pm On May 04 |
JustCryptos: I also had issue with one of the packs I helped someone to buy from him. 24v 102ah pack married to 4 pcs 350w monocrystalline via powerMr MPPT CC. It went bad before one year warranty ran out and I immediately notified him to which he was positively disposed to me sending it back for checks. But cos it happened during the peak of the sunny season, the problem only comes up when the sun is down and the battery runs down within 2 hrs on just 213L deep freezer which is the only appliance person uses it for. And since there was no immediate alternative to keep her freezer working while the pack is sent for repairs, she still hung on to it and kept managing it like that. Then came the rainy season the following year, which was already going to two years after purchase, she couldn't manage it anymore. So I had to remove one of my stacks of 24v 50ah lithium stacks and gave her to use pending the time it's sent for repairs. I have 4 stacks of the Lithium (self assembled) which I use so I'm down to 3 stacks at the moment. September 2023, I called. He said he wasn't on ground in Jos but that he has his technical person on ground there and gave the details of the recipient. I spent 19k to send it to Jos using speedaf express so as to ensure careful handling. After three days, technician called that he'd repaired it and I spent another 11k5 to bring it back, also via speedaf cos I specifically demanded for that method. After I received it, I was busy for about 1 week so couldn't even check what he did. The second week upon testing it, I was shocked to discover that ńa still exactly the same problem. As if the guy didn't open it up (although the warranty seal was broken sha which suggested it was opened). But walahi, na like say dude just kept it for 3 days and then called me that he'd repaired it without opening it up. Dejectedly, I just packed it in one corner and hadn't bothered so much since the woman that owned it is doing well without complaints with the stack I gave her from mine. I chatted the Jos guy (not the technician o) up and he indeed expressed concern that the issue persisted and suggested we do the diagnosis together via video chat. But aswear, I never get time to do that since that time. To even carry the battery alone, cos it's heavy, ńa headache for me. So trying to hook it up to any set up for diagnostics is already worrisome for me. Please note: This is the only battery that had problem out of the many I bought and referred to him. In total over the past three years, I gave him four referrals and I bought two for personal use from him. It's only that one that had problem. So he scored at least 84% assessment from me. 2 Likes |
Re: Solar Energy, A Complement To FTA by Oshomo12(m): 7:14pm On May 04 |
TechGeek777: Oh, 500v was in my head. 11 in series then. |
Re: Solar Energy, A Complement To FTA by ceaser: 7:39pm On May 04 |
bassdow: You're welcome bro. We all learn new things everyday don't we? So it's okay to be open to updated facts and ideas. |
Re: Solar Energy, A Complement To FTA by durodee(m): 7:44pm On May 04 |
mahkanjuh:No sir! Not mine |
Re: Solar Energy, A Complement To FTA by durodee(m): 8:11pm On May 04 |
Xanderone:My experience is quite similar. There was this specific pack that was sent back to Jos THREE times before a cell was changed to resolve the problem. About a year now and no new issue. All the back and forth could be distressing with all the logistic logjam in Nigeria. I have four of his packs in my house now ( 3 bought directly from him and 1 as being prior-owned by a member of this forum) I have 7 different Lithium packs in use - a Felicity 15kwh, a Pylontech US 3000,a 7.5kwh, 2x6kwh pack, 5kwh and a 3kwh and he built 4 of those packs 2 Likes 1 Share |
Re: Solar Energy, A Complement To FTA by Peterlove11: 8:11pm On May 04 |
mctfopt:You can go for 8 x 625w jinko panels all in series. Attached is the screenshot of specifications
|
Re: Solar Energy, A Complement To FTA by Xanderone: 8:56pm On May 04 |
Dam5reey1: Hi. Please can I get the link for this "Sako" guys? I want to check it their solar panel offerings and prices. I'm hearing of them for the first time though. |
(1) (2) (3) ... (1690) (1691) (1692) (1693) (1694) (1695) (1696) ... (1854) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: diabeticdeals and 3 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 54 |