Re: Solar Energy, A Complement To FTA by Drgreatone: 4:30pm On Nov 16, 2024
easyyoke:
Make una please help me answer๐Ÿ™ ๐Ÿ™๐Ÿ™

Does this occur while inverter is switched off? If nope, switch off the inverter
Re: Solar Energy, A Complement To FTA by Drgreatone: 4:31pm On Nov 16, 2024
Trippledots:


Same here. But na for bungalow height, and my balcony directly overlooks them, so Dem de there like rock.
Waut u mean u just put the panel on the roof without anything to hold it down? What type of roofing and is it slopy?
Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 8:06pm On Nov 16, 2024
4.2kw 120A MPPT inbuilt
7.5kwh LFP

4 Likes

Re: Solar Energy, A Complement To FTA by easyyoke: 6:02am On Nov 17, 2024
microgiant:


How can people help you with answer?

I am not vast in RE but it is better you give all information, to help those who are willing to answer your questions.

You ask a vague question and expected people to crack their brain and solve your problem.

There is no Inverter known as all in one, what brand of inverter are you using?


Lol. Hybrid inverters are the inverters called All in One. Inverters with Charge Controller, AC Charger and Inverter is called AIO. When you dont know something, just say you dont know and move on๐Ÿ˜…
Re: Solar Energy, A Complement To FTA by Iinnov8: 8:11am On Nov 17, 2024
60A Powmr MPPT Solar Charge Controller available.

Comes with free DC digital voltage meter worth 4,000

Price: 95,000 firm

1 Share

Re: Solar Energy, A Complement To FTA by KINGKONG(m): 1:24pm On Nov 17, 2024
EduTechTainMent:


Nice one. Mind sharing the brand and price you got it?

Felicity brand, got it for 280k

1 Like

Re: Solar Energy, A Complement To FTA by KINGKONG(m): 1:32pm On Nov 17, 2024
KINGKONG:


120A CC bought and installed.... Awaiting tomorrow sunlight to see it's performance

Thanks for your recommendation and advice

The inverter system is handling load like machine โ˜บ๏ธโ˜บ๏ธ

As the sun dey fire dey go, Na so the equipment dey jam am dey go

Thanks for recommendation and advise here

Inverter: Tusker 12V 1.5KVa transformer based
CC: 120A Charge controller from Felicity
Battery: 12V GSR Tall tubular battery (To be upgraded soon)
Panels: 580W X 3 from Jinko

Equipment used but not at the same time

Industrial Weaving machine using Servo-motor X 1
Industrial Sewing machine using Servo-motor X 1
Industrial Buttonhole machine X 1
Industrial Button Tacking machine X 1
Ceiling fan X 5 (Short blade)

2 Likes

Re: Solar Energy, A Complement To FTA by emmaniche: 2:01pm On Nov 17, 2024
Good Day Gurus,

Long time no post no see.

Please i need an installer in Eket, Akwa Ibom.

Did a job and was hitting 30 to 35amps. suddenly getting 12 or 13amps.

Please i need ur input and if i kud get someone to come help check it.

hit me up at 08165471453.

Thanks.
Re: Solar Energy, A Complement To FTA by Hybrid600: 3:20pm On Nov 17, 2024
Shey you want make your ears dey produce milk everywhere ๐Ÿ˜‚


swagifted:
this is the only CNG i know oo ๐Ÿ˜‚
Re: Solar Energy, A Complement To FTA by odimbannamdi(m): 3:39pm On Nov 17, 2024
Trippledots:


Baba, those cracked panels still de blast ba? ๐Ÿ˜Š

Yes boss! Still blazing!

1 Like

Re: Solar Energy, A Complement To FTA by Hybrid600: 4:32pm On Nov 17, 2024
Nicely done.
If those tubular batteries could, they for don hold you for neck for relegating them ๐Ÿ˜.



Dam5reey1:
Anyways, we successfully converted 2, units of 24V 280AH into 48V 280AH, single Unit, using the available resources..

14.4kw + 6kva..

Re: Solar Energy, A Complement To FTA by compunigeria: 4:37pm On Nov 17, 2024
Dam5reey1:
Anyways, we successfully converted 2, units of 24V 280AH into 48V 280AH, single Unit, using the available resources..

14.4kw + 6kva..


Please wont they work when connected in series to get the 48v?

If yes, what are the disadvantages of doing that compared to the above?
Re: Solar Energy, A Complement To FTA by Drgreatone: 4:39pm On Nov 17, 2024
KINGKONG:


The inverter system is handling load like machine โ˜บ๏ธโ˜บ๏ธ

As the sun dey fire dey go, Na so the equipment dey jam am dey go

Thanks for recommendation and advise here

Inverter: Tusker 12V 1.5KVa transformer based
CC: 120A Charge controller from Felicity
Battery: 12V GSR Tall tubular battery (To be upgraded soon)
Panels: 580W X 3 from Jinko

Equipment used but not at the same time

Industrial Weaving machine using Servo-motor X 1
Industrial Sewing machine using Servo-motor X 1
Industrial Buttonhole machine X 1
Industrial Button Tacking machine X 1
Ceiling fan X 5 (Short blade)








Why do I feel like u would end up cooking ur battery with that charge controller and shorten the lifespan

2 Likes

Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 6:45pm On Nov 17, 2024
compunigeria:


Please wont they work when connected in series to get the 48v?

If yes, what are the disadvantages of doing that compared to the above?

The BMS that came with it does not support series connection.
They may be voltage drift on the long run, also the plan was to get a 6KVA inverter to power the required load.
Re: Solar Energy, A Complement To FTA by compunigeria: 6:54pm On Nov 17, 2024
KINGKONG:


The inverter system is handling load like machine โ˜บ๏ธโ˜บ๏ธ

As the sun dey fire dey go, Na so the equipment dey jam am dey go

Thanks for recommendation and advise here

Inverter: Tusker 12V 1.5KVa transformer based
CC: 120A Charge controller from Felicity
Battery: 12V GSR Tall tubular battery (To be upgraded soon)
Panels: 580W X 3 from Jinko

Equipment used but not at the same time

Industrial Weaving machine using Servo-motor X 1
Industrial Sewing machine using Servo-motor X 1
Industrial Buttonhole machine X 1
Industrial Button Tacking machine X 1
Ceiling fan X 5 (Short blade)










in a set up like this, i believe reducing the charge controller charging current from 120A to 20-30A will prevent "choking" the battery with excessive current rush.


However,what i believe senior members can help us clarify is...

At the max current of 120A he should potentially be able to generate 1740w( 580w X3)
After reducing the current to 20A to protect the batteries, will that affect the maximum power that can be generated ?
can he still power the same load like before during peak sunlight periods?
Re: Solar Energy, A Complement To FTA by compunigeria: 6:57pm On Nov 17, 2024
Dam5reey1:


The BMS that came with it does not support series connection.
They may be voltage drift on the long run, also the plan was to get a 6KVA inverter to power the required load.


Thanks for the clarification
Re: Solar Energy, A Complement To FTA by bleexInc(m): 8:23pm On Nov 17, 2024
Hello House,

Which battery is best to use with luminous Eco volt Neo 1500va 24V inverter. Considering that Amaron quanta battery got damaged in less than a year.
Thank you
Re: Solar Energy, A Complement To FTA by Trippledots(m): 8:30pm On Nov 17, 2024
bassdow:
Don't get you

Any roof installation higher than ground floor building, please use standard rack or at at the least, a binding wire.
Re: Solar Energy, A Complement To FTA by Trippledots(m): 8:31pm On Nov 17, 2024
Drgreatone:

Waut u mean u just put the panel on the roof without anything to hold it down? What type of roofing and is it slopy?

Yes.

Asbestos roof.

Almost flat.

The panels are big..400w and above
Re: Solar Energy, A Complement To FTA by osayuwamwen(m): 10:47pm On Nov 17, 2024
Pls can i use 2 pair of 12v 100ah with 4kva inverter to power 1.5hpower submersible pump?
Re: Solar Energy, A Complement To FTA by mctfopt: 6:22am On Nov 18, 2024
osayuwamwen:
Pls can i use 2 pair of 12v 100ah with 4kva inverter to power 1.5hpower submersible pump?


1.5HP submersible consumes about 1700 watts. 2 nos of 12v 100ah is about 2400wh (I'm assuming the batteries are lithium batteries). The run hours will be less than 1 hour 30 minutes. You are also draining it at a high C-rate of 75A (I'm assuming the 4kva is a 24v inverter) which is almost 1C.


Unless you do this during heavy sunshine (I'm assuming you have like 3000w of solar panels) this will continuously strain your battery.

Also I'm assuming the battery is wired with appropriately sized cables and have fuses and breakers of right capacity.

My recommendation: consider getting a standalone solar panels + DC/AC pump to replace the current AC submersible pump, or upgrading the system to 48v and get a 48v lithium battery (from 7.5kwh upwards) to run this pump or finally to use NEPA/Gen to pump water.

6 Likes

Re: Solar Energy, A Complement To FTA by FEGEITOK: 6:50am On Nov 18, 2024
bleexInc:
Hello House,

Which battery is best to use with luminous Eco volt Neo 1500va 24V inverter. Considering that Amaron quanta battery got damaged in less than a year.
Thank you

Been running mine for 4 years and they haven't been damaged.

Are you sure this isn't a case of abuse?

1 Like 1 Share

Re: Solar Energy, A Complement To FTA by HeavenlyBang(m): 7:34am On Nov 18, 2024
mctfopt:



1.5HP submersible consumes about 1700 watts. 2 nos of 12v 100ah is about 2400wh (I'm assuming the batteries are lithium batteries). The run hours will be less than 1 hour 30 minutes. You are also draining it at a high C-rate of 75A (I'm assuming the 4kva is a 24v inverter) which is almost 1C.


Unless you do this during heavy sunshine (I'm assuming you have like 3000w of solar panels) this will continuously strain your battery.

Also I'm assuming the battery is wired with appropriately sized cables and have fuses and breakers of right capacity.

My recommendation: consider getting a standalone solar panels + DC/AC pump to replace the current AC submersible pump, or upgrading the system to 48v and get a 48v lithium battery (from 7.5kwh upwards) to run this pump or finally to use NEPA/Gen to pump water.


Remind me how 1.5 HP is 1700w again?
Re: Solar Energy, A Complement To FTA by TechGeek777: 9:06am On Nov 18, 2024
HeavenlyBang:


Remind me how 1.5 HP is 1700w again?


Real power draw is different from spec sheet based on many factors (length of pump to where pipes start from, wire Guage and wrong labeling of actual pump capacity).

What most buy as 1.5hp is mostly 2hp pump.

Ordinary this supposed to be 1.5kw, but above factors could make it consume upto 2.3kw in real usage compared to the typical 1.1kw you would seen boldly written on the body of the pump.

4 Likes

Re: Solar Energy, A Complement To FTA by mctfopt: 9:27am On Nov 18, 2024
HeavenlyBang:


Remind me how 1.5 HP is 1700w again?


This is real life measurement. I'm not using paper specs. My 1.5HP Sumo draws 7.3A @ 230V

2 Likes

Re: Solar Energy, A Complement To FTA by bassdow: 9:39am On Nov 18, 2024
Trippledots:


Any roof installation higher than ground floor building, please use standard rack or at at the least, a binding wire.
of course, me never dare just drop solar panel on top roof with nothing to hold it, even if na bungalow. Reason I was surprised when someOne said they do.

2 Likes

Re: Solar Energy, A Complement To FTA by HeavenlyBang(m): 11:34am On Nov 18, 2024
TechGeek777:


Real power draw is different from spec sheet based on many factors (length of pump to where pipes start from, wire Guage and wrong labeling of actual pump capacity).

What most buy as 1.5hp is mostly 2hp pump.

Ordinary this supposed to be 1.5kw, but above factors could make it consume upto 2.3kw in real usage compared to the typical 1.1kw you would seen boldly written on the body of the pump.

mctfopt:


This is real life measurement. I'm not using paper specs. My 1.5HP Sumo draws 7.3A @ 230V

Fair enough. TIL.
Re: Solar Energy, A Complement To FTA by kiekie1(m): 12:56pm On Nov 18, 2024
AVAILABLE!!!


Distilled water 25 Litres = N13,000 PER 25L GALLON (Selling with free 25L black Gallon)(BUY 2 GALLONS & GET 5L FREE)

Distilled water 25 Litres = N15,000 PER 25L GALLON (Selling with free 25L white Gallon)(BUY 2 GALLONS & GET 5L FREE)

Distilled water 5 Litres = N3,500 (Selling with free 5L gallon) (PROMO: BUY 12 units get 2 free)

Hydrometer = N8,000

Electrolyte 5L = N5,000

Electrolyte 25 Litres = N20,000 (with free 25L Industrial Gallon) .. (BUY 2 GALLONS & GET 5L DISTILLED WATER FREE).


๐Ÿ“ž O8135O31951

1 Like

Re: Solar Energy, A Complement To FTA by kiekie1(m): 1:40pm On Nov 18, 2024
WE BUY DEAD/SCRAP BATTERIES!!!

We also buy off scrap/dead deep cycle batteries from any state to Lagos (Terms & Condition applies) ..

You could make money from your dead or swollen batteries.


12v 200a ..... N70,000
12v 150a.......N47,500
12v 100a.......N35,000
2v 500a ........N15,000

Free pickup within some parts of Lagos mainland but Shared cost logistics within Lagos Island environs . . If outside Lagos state , send the scrap batteries to your nearby Lagos park & get your payment alert immediately after confirmatory remarks from me with the transport company manager / secretary or driver shared logistics cost depending on scrap battery quantity) ..

Scrap batteries could also be traded in for brand new battery replacements..... Prices might be reviewed from time to time

O8135O31951
Re: Solar Energy, A Complement To FTA by Gshems: 1:53pm On Nov 18, 2024
Please who sells dc breakers and spd here
Re: Solar Energy, A Complement To FTA by TechGeek777: 7:28pm On Nov 18, 2024
Gshems:
Please who sells dc breakers and spd here
https://www.nairaland.com/zeestone99

1 Like 1 Share

Re: Solar Energy, A Complement To FTA by odimbannamdi(m): 7:49pm On Nov 18, 2024
osayuwamwen:
Pls i need help my inverter has refused to power on each time I switch it on the back light on the display on but nothing is displaying on the screen, it happens like this b4 but it later come on but this time it has gone blank

Hello bro,

How were you able to work around this?

(1) (2) (3) ... (1853) (1854) (1855) (1856) (1857) (1858) (1859) ... (1997) (Reply)

Free To Air Satellite Tv General Thread

Viewing this topic: maklelemakukula(m), dayjavoo, Mrreed(m), Bruteality1, ManAdii and 5 guest(s)

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health