Re: Solar Energy, A Complement To FTA by bleexInc(m): 10:21pm On Nov 26, 2024 |
Hello house , Which lifepo4 battery will you recommend for a 1.5kva luminous inverter |
Re: Solar Energy, A Complement To FTA by ajabani4allah(m): 10:33pm On Nov 26, 2024 |
dollarnaira: You are welcome bro |
Re: Solar Energy, A Complement To FTA by toyeoye(m): 12:43am On Nov 27, 2024 |
HeavenlyBang: You must have had a terrible experience...smooth sailing on day 1 set of lead acid over here for years and running...and with proper maintenance |
Re: Solar Energy, A Complement To FTA by Sakopower: 6:26am On Nov 27, 2024 |
Call/WhatsApp: 08033213577
|
Re: Solar Energy, A Complement To FTA by HeavenlyBang(m): 6:38am On Nov 27, 2024 |
bleexInc: 12v or 24v? |
Re: Solar Energy, A Complement To FTA by Dageek: 7:19am On Nov 27, 2024 |
please signify If you sell genuine SPD, Breakers and AVR |
Re: Solar Energy, A Complement To FTA by Xanderone: 7:03pm On Nov 27, 2024 |
So I got this Tuya DC meter to test out it's functions. I'd been angry with dem Chinese for not thinking out a way to make a DC meter that works on Tuya platform despite the numerous smart add-ons that they have on that platform. . I present to you, the Tuya Smart DC meter. Second and fourth pictures are screenshots of some of the functions as it is on my mobile. Even though with felicity hybrid I use, I can have some online monitoring capacity. But this Tuya meter appears to pack some punches. 3 Likes 1 Share
|
Re: Solar Energy, A Complement To FTA by bleexInc(m): 7:10pm On Nov 27, 2024 |
HeavenlyBang:24v |
Re: Solar Energy, A Complement To FTA by Xanderone: 7:11pm On Nov 27, 2024 |
bsideangel: From my own experience, dust is doing a serious number on panels during the dry season especially if you are in a place where there is untarred section of a busy road. Once before, dust build-up on the panels have reduced charging output by as much as 30%. Then there is this issue of hot sun in dry season, at temperatures which exceed the optimum operating temperature of those panels. À well ventilated panel (on the underside) installation can help mitigate that heat-indicted drop in capacity 2 Likes |
Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 7:49pm On Nov 27, 2024 |
7pcs of 25kwh 48v felicity lithium battery waybill to OYO state today, all thanks to MR kazeem for the patronage, God will continue to bless you and bless everyone on this platform who has been patronizing me, and also referring my brand to others.. Una own no go spoil… To order yours call/whatsapp me on 08168986461 4 Likes
|
Re: Solar Energy, A Complement To FTA by mctfopt: 7:50pm On Nov 27, 2024 |
Xanderone: Dust can drastically reduce capacity. Those near busy dusty roads are in for some crazy power reduction this period. |
Re: Solar Energy, A Complement To FTA by mctfopt: 7:51pm On Nov 27, 2024 |
Xanderone: I keep skipping this meter when I see it. The reviews of the ones I saw wasn't too grear. Is it rugged enough? |
Re: Solar Energy, A Complement To FTA by Xanderone: 8:57pm On Nov 27, 2024 |
mctfopt: Can't tell yet. I'm just 2 days into its use. I guess time will tell. But sha, it's a new product, apparently not more than 2 months or so that it was produced and introduced intk the market cos I just saw it on AE this month. |
Re: Solar Energy, A Complement To FTA by Xanderone: 10:00pm On Nov 27, 2024 |
https://www.youtube.com/watch?v=UbZiHzflKMY?si=CI6ou-19AO3kEnIs Your LFP doesnt mind being charged to full. Li-ion may have that issue though cos I recall my Samsung phone has a battery protect setting to limit charging to 85%. With that, the charging will never reach 100% full, only stops at 85%. I know Li-ion is used in cell phones. ask4bk: 1 Like |
Re: Solar Energy, A Complement To FTA by mctfopt: 10:09pm On Nov 27, 2024 |
Xanderone: Yeah it's new. Ok, let's see how it goes. |
Re: Solar Energy, A Complement To FTA by compunigeria: 8:20am On Nov 28, 2024 |
Xanderone: Very very interesting features. Could be used for LVD, tracking the cummulative energy generated and online access.... Kindly keep us updated on the personal user experience. |
Re: Solar Energy, A Complement To FTA by Ifexabc: 10:01am On Nov 28, 2024 |
Hello Guys, Good morning.... Our product offerings include, but are not limited to, the following: JA 580 Mono Solar Panels 5kWh/48V BYD Lithium Batteries Leoch Lead Carbon 12V 200Ah Batteries Voltronic Hybrid Inverters-3KW & 5KW Victron Battery Inverters-3KVA/5KVA/8KVA/10KVA( Multiplus & Quattro brand) String Inverters-20KW/50KW/60KW/100KW ( Huawei & Goodwe brand) We believe that these high-quality products would be an excellent fit for your business. We would be thrilled to have you join our list of esteemed dealers and work together to expand the reach of these products. Please let us know if you are interested in exploring this partnership further. We also sell Perkins, MTU and Gas Generators ranging from 15kva-2500kva. 580w Panels = ₦155,000 EACH Battery = ₦400k each Whatsapp or Call: 08033664334...
|
Re: Solar Energy, A Complement To FTA by ask4bk(m): 11:37am On Nov 28, 2024 |
Xanderone:The man in that video has been debunked as false. If you knew the charging curve of LFP you won't say this. When charging from 3.39v sef to 3.65 is sharp upward line that could take only 3 minutes to attain. When discharging, LFP takes same quick time to move from 3.65 to 3.37 then begins an almost straight but long curve to 2.6 or below. Keeping charge at 3.65v you are not only producing heat but putting it at the high threshold and risking overcharging errors. It's good to keep it far from 3.65v to be save from charger errors, and for LFP, be it 3.4v or 3.65v, it won't take 5 minutes to return it's sitting voltage of 3.31-3.37 |
Re: Solar Energy, A Complement To FTA by ask4bk(m): 11:42am On Nov 28, 2024 |
Xanderone: I need one please. Where do you connect it? In the inverter or just the battery negative/positive terminals? |
Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 11:53am On Nov 28, 2024 |
ask4bk: Please stop saying this, I have cells I charged to 3.6V for almost a month now, it still ast 3.5V+ and it not producing any heat. 1 Like |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 1:39pm On Nov 28, 2024 |
Hello House. The following items are available. Eve 100ah 3.2v lifepo4 battery - 59k Rept 280ah 3.2v lifepo4 battery - 109k 100ah 12.8v lifepo4 battery - 270k DM to place orders and thanks for your patronage. Call/chat - 08117398294 1 Like
|
Re: Solar Energy, A Complement To FTA by imatejammer: 1:57pm On Nov 28, 2024 |
I got this quote for an inverter set up to power 3 Panasonic ceiling fans and 6 energy bulbs for 6 straight hours: (No solar panels) SMARTEN 1.5KVA INVERTER---------------------------200k STARPLUS (TUBULAR) BATT 12V/200AH-----------260K CHANGE OVER BREAKER------------------------------------8K RACK -----------------------------------20K LINE MONITOR ----------------------------------12K INSTALLATION FEE ----------------------------------35K T O T A L--------------------------------------------------------535K Is this a fair quotation? What if I want lithium battery IN THE MIX? what size and price? |
Re: Solar Energy, A Complement To FTA by HeavenlyBang(m): 3:31pm On Nov 28, 2024 |
imatejammer: The literally post above yours advertises a 12v 100ah lifepo4 battery for 270k. Powmr's is tested and costs 290k, though 1 Like |
Re: Solar Energy, A Complement To FTA by Jefferyzz(m): 3:35pm On Nov 28, 2024 |
That lead acid battery is the problem. Buy 12v 100a Lifepo4 battery from valto to replace that. Incase the inverter doesn't av an inbuilt AC n DC breaker, get d 2 n put it d DC between battery and inverter n AC between Ur inverter output n the change over. imatejammer: |
Re: Solar Energy, A Complement To FTA by ask4bk(m): 5:13pm On Nov 28, 2024 |
Dam5reey1: You are definitely not using the battery. Left unused LFP will stay at 3.6v for months if you charge it to that. Lithium doesn't leak voltage like lead batteries. But if you have it on load (without charging), there's no way it'll stay in 3.6v for a long time. It'll quickly go to it's sitting voltage below 3.4v. That's just how they work. |
Re: Solar Energy, A Complement To FTA by Valto(m): 6:52pm On Nov 28, 2024 |
imatejammer:3pcs Panasonic ceiling fan around 70w each=210w 6 energy bulb approximately 40w inverter conversion draw approximately 30w so lets say 300w for 6hrs= 1.8kwh. Even 12v 100ah 1.2kwh lithuim battery or 1pcs tubular battery can't do the job) the best battery and inverter for u is as follows 12v 2.2kwh lifepo4 lithium battery 12v 1kw hybrid inverter i can offer u both for 670k! whatsapp 08020574628 or telegram@ValtechEnergy 2 Likes 4 Shares
|
Re: Solar Energy, A Complement To FTA by Obnoxious2001(m): 7:15pm On Nov 28, 2024 |
imatejammer: I think this is fair enough. |
Re: Solar Energy, A Complement To FTA by Tucode: 7:51pm On Nov 28, 2024 |
Hello guys, good evening. Can anyone tell me about SMS hybrid inverter in terms of durability and performance? I am planning to get a 10.2kva sms transformerless hybrid inverter to replace my older inverter that got damaged. Also, I heard that transformer based inverters are better than transformerless inverters. Also, is there any need for me to add another mppt charge controller to an hybrid inverter that already has a 160A mppt controller? The installer was telling me that I should still get a separate charge controller for it… Please Nairaland inverter profs, I need your urgent response. Finally, apart from Felicity brand, which other inverter brands are reliable and durable and affordable? Thank you. |
Re: Solar Energy, A Complement To FTA by brightk(m): 8:10pm On Nov 28, 2024 |
Tucode:wat exactly damaged d previous one? So we can recommend something better |
Re: Solar Energy, A Complement To FTA by Tucode: 8:34pm On Nov 28, 2024 |
brightk: Okay. The system was installed in first week of August this year. By first week of September, the charge controller had gotten bad. The charge controller would not read (the watts and amps will be showing 0.00) but the battery will be charging. It’s a 15kwh Felicity lithium battery. The charge controller is also felicity. So the installer took the charge controller to the company to repair. He brought it back 3 weeks later. After 5 days, the charge the issue resurfaced. The controller won’t read anything but the battery will charge (although it charges slower than it normally does with the controller ). We kept using the system like that while waiting for the installer to return the charge controller. Then two Sundays ago, we got back from church and smelled something burning, we went to check and it was the inverter (10kva felicity non hybrid inverter). The installer came to remove everything and took it back to the company and they said the inverter was burnt. I have never loaded beyond 28% on the inverter since we got it. That’s what happened. I don’t know how manage it happened. |
Re: Solar Energy, A Complement To FTA by brightk(m): 9:58pm On Nov 28, 2024 |
Tucode: the same thing would happen if you buy another set of equipment... there seems to be a connection problem here.. An inverter doesnt get burnt in a hurry.. something must have triggered it.. if i may ask do you have enough protection attached to these devices.. How are we sure those equipments are original esp the felecity charge controller.. As for the lithium battery i have never used felecity but since you do, do you have a way of monitoring what goes in and out of the battery.. and your panels, what brands and how are they connected( ![]() i think you may need another installer.. maybe you can snap the remaining skeletal structure.....lets have a look esp the protection part.. Also state your location maybe someone here can come have a look 2 Likes 1 Share |
Re: Solar Energy, A Complement To FTA by mctfopt: 11:40pm On Nov 28, 2024 |
@tucode follow @brightk suggestion. Inverter does not just burn . I know. I once used one 1.5kva Luminous inverter for 8 years. Crazy thing inverter is still in service, no longer with me though. If all connections are ok and house does not have a wiring problem, then inverter should not go bad, especially without thunderstorms as we are in dry season. 1 Like |
(1) (2) (3) ... (1858) (1859) (1860) (1861) (1862) (1863) (1864) ... (1921) (Reply)
Free To Air Satellite Tv General Thread
Viewing this topic: 2 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2025 Oluwaseun Osewa. All rights reserved. See How To Advertise. 71 |