Re: Solar Energy, A Complement To FTA by BigDickProblems: 10:23am On Jan 29
BigDickProblems:
Hi guys.

My felicity charge controller throws an “04” error-battery voltage is high. Even when the voltage of the battery is just 12.7V and not anywhere close to. 14.6V.

This has happened before, but I fixed it by disconnecting the entire CC connection and connecting it to another Controller (PWM), and after a while I reconnect back.

But this can be really stressful. Pleas what’s the solution?
I’m really seeing this Felicity charge controller as being useless and overhyped. It’s really frustrating.
Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 11:25am On Jan 29
1pcs of 10kwh 48v felicity lithium battery and 1pcs of 5kva Growatt hybrid inverter ready for delivery to Eket, akwa - ibom state.. Call/whatsapp me on 08168986461

Re: Solar Energy, A Complement To FTA by compunigeria: 4:39pm On Jan 29
BigDickProblems:

I’m really seeing this Felicity charge controller as being useless and overhyped. It’s really frustrating.
What are your settings for

Absorb
Float
And maximum charging current?
Re: Solar Energy, A Complement To FTA by BigDickProblems: 5:14pm On Jan 29
compunigeria:

What are your settings for
Absorb
Float
And maximum charging current?

I set the Absorbtion to 14.4V, and since you can’t change the float voltage of the Controller if you selected lithium battery “Lib”, it will use the same 14.4V as the Float voltage. However, I know that Lithium ion batteries floats at 13.6V.

Tha maximum charging current is 30Amp.

1 Like

Re: Solar Energy, A Complement To FTA by olopan(m): 8:24pm On Jan 29
since this was fixed temporarily before when you had it disconnected, i will advise that you have a pv breaker and a battery breaker on the charge contoller so you can reset it everytime the error pops up.
BigDickProblems:

I’m really seeing this Felicity charge controller as being useless and overhyped. It’s really frustrating.

3 Likes

Re: Solar Energy, A Complement To FTA by compunigeria: 12:20am On Jan 30
BigDickProblems:


I set the Absorbtion to 14.4V, and since you can’t change the float voltage of the Controller if you selected lithium battery “Lib”, it will use the same 14.4V as the Float voltage. However, I know that Lithium ion batteries floats at 13.6V.

Tha maximum charging current is 30Amp.


Reset all to default settings, dont limit the charging current and try it out again. That was how their service centre technician did to mine.
Re: Solar Energy, A Complement To FTA by BigDickProblems: 12:34am On Jan 30
compunigeria:



Reset all to default settings, dont limit the charging current and try it out again. That was how their service centre technician did to mine.

Oh ok thanks.

Sorry, but how do I reset to default? Do you mean I should manuallly input the default values or is there a another way to do the default settings?
Re: Solar Energy, A Complement To FTA by BigDickProblems: 12:35am On Jan 30
olopan:
since this was fixed temporarily before when you had it disconnected, i will advise that you have a pv breaker and a battery breaker on the charge contoller so you can reset it everytime the error pops up.

That’s a good idea too. I will consider that. Thanks.

1 Like

Re: Solar Energy, A Complement To FTA by Haykay2001: 2:57am On Jan 30
Is this still available? Droped a message for you on WhatsApp, but no response yet.


Iinnov8:
1. 60A PowMr MPPT Solar Charge Controller
Price: 91,500

2. 60A PowMr MPPT Solar Charge Controller plus useful DC Battery Voltage meter
Price: 95,000
Re: Solar Energy, A Complement To FTA by Iinnov8: 7:15am On Jan 30
Haykay2001:
Is this still available? Droped a message for you on WhatsApp, but no response yet.



Responded.

1 Like

Re: Solar Energy, A Complement To FTA by fuckboys: 7:18am On Jan 30
With the rain yesterday, I need to monitor my peak solar harvest today on a 3pcs of 180w africell panels. Was getting 230w peak before witn an mppt 30a cc
Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 7:22am On Jan 30
fuckboys:
With the rain yesterday, I need to monitor my peak solar harvest today on a 3pcs of 180w africell panels. Was getting 230w peak before witn an mppt 30a cc

Where una dey see rain oo?

1 Like

Re: Solar Energy, A Complement To FTA by Ifexabc: 7:29am On Jan 30
Good Morning....

Our product offerings include, but are not limited to, the following:

JA 580 Mono Solar Panels - Bifacial
5kWh/48V BYD/Leoch Lithium Batteries
11.7kWh/48V Leoch Lithium Batteries
5kWh High Voltage Deye Batteries
String Inverters-25KW/50KW/100KW/120 Goodwe brand
Hybrid Inverters 5KW - 48V - single phase - Voltronic
Hybrid Inverter 8 & 12kW - 48V - 3 phase - Deye
Hybrid Inverter 20 & 50kW - 160V-800V - 3 phase - high voltage - Deye

We believe that these high-quality products would be an excellent fit for your business. We would be thrilled to have you join our list of esteemed dealers and work together to expand the reach of these products.
Please let us know if you are interested in exploring this partnership further. We also sell Perkins, MTU and MWM Gas Generators ranging from 15kva-2500kva...

580w Panels = ₦150,000 EACH (10yrs Warranty and 25yrs Lifespan)

Re: Solar Energy, A Complement To FTA by fuckboys: 7:30am On Jan 30
Dam5reey1:


Where una dey see rain oo?
e fall wella yesterday, Lagos amuwo odofin

1 Like

Re: Solar Energy, A Complement To FTA by compunigeria: 8:44am On Jan 30
BigDickProblems:


Oh ok thanks.

Sorry, but how do I reset to default? Do you mean I should manuallly input the default values or is there a another way to do the default settings?

Disconnect all the cables, reconnect them after a while then enter the default settings Manually. We can talk via whatsapp, if there is need for further clarification.

2 Likes

Re: Solar Energy, A Complement To FTA by BigDickProblems: 9:17am On Jan 30
compunigeria:


Disconnect all the cables, reconnect them after a while then enter the default settings Manually. We can talk via whatsapp, if there is need for further clarification.

Well noted and understood. I appreciate chief. Thanks.
Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 9:52am On Jan 30
1000w and 2000w colasolar generator now available.

1000w - 340,0000
2000w - 730,0000.

Can power your fridge, Tv, laptops, lighting points etc..

Call/whatsapp me on 08168986461

Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 1:21pm On Jan 30
Good to be back again.
Back to BMS SOC thing.
This post is for educational purposes..

As a Customer service person, I support several brand now.
So a Customer reached out this yesterday and his inverter was showing 24.6V with 58% SOC on the battery.

To an average User, Our Client has 58% why is inverter showing low Voltage warning, was scared that something is wrong and turned off everything grin

So according to our client Sun has been poor and battery has not been charging well, So we checked the voltages and told our client your batteries are close to dead, but how do we explain this when battery is showing SOC at 58%..

So we explained LFP voltage curve blablabla. Client was convinced but not fully.

Fast forward to today.

Out of curiosity we received the video of the battery now at 100% but still charging at ~12.8A.

Upon inspection we saw average Voltage at 3.34 means this battery cannot be at 100% it just BMS fooling itself.

So we explained that Flat voltage curve of LFP and informed the client that the Battery will be Fully charged when the average cell voltage is at 3.45 and above and the charging current is Zero Amp.

Client now fully understand the whole LFP Curve and BMS drift.

-Solaris Surge

1 Like

Re: Solar Energy, A Complement To FTA by SourYoghurt: 1:40pm On Jan 30
Dam5reey1:
Good to be back again.
Back to BMS SOC thing.
This post is for educational purposes..

As a Customer service person, I support several brand now.
So a Customer reached out this yesterday and his inverter was showing 24.6V with 58% SOC on the battery.

To an average User, Our Client has 58% why is inverter showing low Voltage warning, was scared that something is wrong and turned off everything grin

So according to our client Sun has been poor and battery has not been charging well, So we checked the voltages and told our client your batteries are close to dead, but how do we explain this when battery is showing SOC at 58%..

So we explained LFP voltage curve blablabla. Client was convinced but not fully.

Fast forward to today.

Out of curiosity we received the video of the battery now at 100% but still charging at ~12.8A.

Upon inspection we saw average Voltage at 3.34 means this battery cannot be at 100% it just BMS fooling itself.

So we explained that Flat voltage curve of LFP and informed the client that the Battery will be Fully charged when the average cell voltage is at 3.45 and above and the charging current is Zero Amp.

Client now fully understand the whole LFP Curve and BMS drift.

-Solaris Surge
dead as in the way Mandela is dead or drained like the way our foreign reserves are drained with an option to fill it up when Nigerians are ready?
Re: Solar Energy, A Complement To FTA by Ferdiwar: 1:47pm On Jan 30
Can the client share a screenshot of the charge settings?

Dam5reey1:
Good to be back again.
Back to BMS SOC thing.
This post is for educational purposes..

As a Customer service person, I support several brand now.
So a Customer reached out this yesterday and his inverter was showing 24.6V with 58% SOC on the battery.

To an average User, Our Client has 58% why is inverter showing low Voltage warning, was scared that something is wrong and turned off everything grin

So according to our client Sun has been poor and battery has not been charging well, So we checked the voltages and told our client your batteries are close to dead, but how do we explain this when battery is showing SOC at 58%..

So we explained LFP voltage curve blablabla. Client was convinced but not fully.

Fast forward to today.

Out of curiosity we received the video of the battery now at 100% but still charging at ~12.8A.

Upon inspection we saw average Voltage at 3.34 means this battery cannot be at 100% it just BMS fooling itself.

So we explained that Flat voltage curve of LFP and informed the client that the Battery will be Fully charged when the average cell voltage is at 3.45 and above and the charging current is Zero Amp.

Client now fully understand the whole LFP Curve and BMS drift.

-Solaris Surge
Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 2:47pm On Jan 30
Ferdiwar:
Can the client share a screenshot of the charge settings?


Was set as per manufacturer's recommendations..
27.8V CV and FLV and 24V CUV
Re: Solar Energy, A Complement To FTA by OgogoroFreak(m): 4:36pm On Jan 30
Which of these inverters should I go for and why?

Re: Solar Energy, A Complement To FTA by dollarnaira: 5:13pm On Jan 30
OgogoroFreak:
Which of these inverters should I go for and why?

Waec 2025
English essay.
No 2.
Nawa o.

Upon the loads of knowledge here? cool

2 Likes

Re: Solar Energy, A Complement To FTA by brightk(m): 5:27pm On Jan 30
Dam5reey1:
Good to be back again.
Back to BMS SOC thing.
This post is for educational purposes..

As a Customer service person, I support several brand now.
So a Customer reached out this yesterday and his inverter was showing 24.6V with 58% SOC on the battery.

To an average User, Our Client has 58% why is inverter showing low Voltage warning, was scared that something is wrong and turned off everything grin

So according to our client Sun has been poor and battery has not been charging well, So we checked the voltages and told our client your batteries are close to dead, but how do we explain this when battery is showing SOC at 58%..

So we explained LFP voltage curve blablabla. Client was convinced but not fully.

Fast forward to today.

Out of curiosity we received the video of the battery now at 100% but still charging at ~12.8A.

Upon inspection we saw average Voltage at 3.34 means this battery cannot be at 100% it just BMS fooling itself.

So we explained that Flat voltage curve of LFP and informed the client that the Battery will be Fully charged when the average cell voltage is at 3.45 and above and the charging current is Zero Amp.

Client now fully understand the whole LFP Curve and BMS drift.

-Solaris Surge
if u want to discredit someone,please do it in a way no one suspects u of been envious.......

4 Likes

Re: Solar Energy, A Complement To FTA by HeavenlyBang(m): 5:55pm On Jan 30
OgogoroFreak:
Which of these inverters should I go for and why?

Growatt of course.

1 Like

Re: Solar Energy, A Complement To FTA by JUO(m): 6:31pm On Jan 30
Flex max Fangpusun
80A-12-60v-150v 300k only 5pcs
60A-12-60v-150v 280k only 3pcs

Blue solar
70A-12-48v-150v 290k
60A-12-48v-150v 250k
45A-12-48v-150v
50A-12-24v-100v 100k only 5pcs
30A-12-24v-100v
Model with inbuilt display
70A-12-48v-150v 300k
60A-12-48v-150v
50A-12-24v-100v 120k only 5pcs

Lithium cells
EVE 280ah 115k minimum order 16pcs
Available. Promo valid for only one month
080-987-337-09
Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 7:01pm On Jan 30
brightk:
if u want to discredit someone,please do it in a way no one suspects u of been envious.......

Not Again!
Re: Solar Energy, A Complement To FTA by mctfopt: 7:02pm On Jan 30
OgogoroFreak:
Which of these inverters should I go for and why?

Growatt any day.

2 Likes

Re: Solar Energy, A Complement To FTA by mctfopt: 7:04pm On Jan 30
brightk:
if u want to discredit someone,please do it in a way no one suspects u of been envious.......


Please can we allow people share their experience on this platform without attacking the messenger? Some may have things to share, which they may be reluctant to share, if they see attacks on people who share their experience.

6 Likes

Re: Solar Energy, A Complement To FTA by obitobe: 7:36pm On Jan 30
Their new rebranded charge controllers are quiet troublesome. Seen people complain about it.

BigDickProblems:

I’m really seeing this Felicity charge controller as being useless and overhyped. It’s really frustrating.
Re: Solar Energy, A Complement To FTA by Valto(m): 7:47pm On Jan 30
perfect installation! cheesy
place your order today, we can waybill /deliver to any location in Nigeria and west Africa.

5 Likes

(1) (2) (3) ... (1899) (1900) (1901) (1902) (1903) (1904) (1905) ... (1997) (Reply)

Free To Air Satellite Tv General Thread

Viewing this topic: jmaine, bigbauer(m), brightk(m), Haykay2001 and 2 guest(s)

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2025 Oluwaseun Osewa. All rights reserved. See How To Advertise. 52
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.