Welcome, Guest: Register On Nairaland / LOGIN! / Trending / Recent / New
Stats: 3,205,341 members, 7,992,075 topics. Date: Saturday, 02 November 2024 at 03:31 PM

Inverter Users : Lets Have Your Experience - Computers (25) - Nairaland

Nairaland Forum / Science/Technology / Computers / Inverter Users : Lets Have Your Experience (663831 Views)

Your Experience With Spectranet Internet Services / Re: Inverter Users : Lets Have Your Experience / Any One Into Security Installations Systems, Lets Have A Deal (2) (3) (4)

(1) (2) (3) ... (22) (23) (24) (25) (26) (27) (28) ... (170) (Reply) (Go Down)

Re: Inverter Users : Lets Have Your Experience by jaz(m): 10:09pm On Dec 16, 2014
zeestone99:

For 5kva 48v with 18w/12v solar panels,u will use 8 of it each cost 50k and a 48v charge controller(25k), plus inverter...everything sums up 2 700k

thanks bro. that's within budget
Re: Inverter Users : Lets Have Your Experience by zeestone99(m): 1:34pm On Dec 17, 2014
jaz:


thanks bro. that's within budget

U can contact us for purchase n installation
@ monz power solutions
tel: 08117398294


Hp 2 hear from u soon... Thnk u
Re: Inverter Users : Lets Have Your Experience by oblo(m): 5:12am On Dec 18, 2014
oblo:
A friend has used 6kva inverter for immediate sale. Working condition and very good for those of you who don't want to break the bank to get a 6kva inverter.

Location is abeokuta.
Call: 07033874048

Still available.
Re: Inverter Users : Lets Have Your Experience by johnny4u2(m): 5:12am On Dec 20, 2014
John on December 20, 2014 at 5:52 am
reply

Hi,
Your replies and inputs are highly informative.
I have a 5KVA and a 3.5KVA inverter used to power different sections of my house. Each is having 8 numbers and 4 numbers 200Ahr batteries respectively. What is the minimum rating of a generator set that I need to charge these inverters separately and also together?
Re: Inverter Users : Lets Have Your Experience by c0ogumo(m): 2:46pm On Dec 20, 2014
johnny4u2:

John on December 20, 2014 at 5:52 am
reply

Hi,
Your replies and inputs are highly informative.
I have a 5KVA and a 3.5KVA inverter used to power different sections of my house. Each is having 8 numbers and 4 numbers 200Ahr batteries respectively. What is the minimum rating of a generator set that I need to charge these inverters separately and also together?

Whats your inverter charging current?
Whats your battery bank voltage?

molley4real@hotmail.com
BB PIN: 79DD915D
whatsapp: 973-204-1296
www.solardepotng.com
Re: Inverter Users : Lets Have Your Experience by Deluxe8000(m): 8:04am On Dec 21, 2014
i have 20ah battery charger to charge my 200ah battery but it seems it discharges when main phcn source is off cos its meter reads even when phcn source is off. pls wat can i do to stop it from discharging?
Re: Inverter Users : Lets Have Your Experience by zeestone99(m): 9:32am On Dec 22, 2014
For ur inverters
Re: Inverter Users : Lets Have Your Experience by kiekie1(m): 12:27am On Jan 05, 2015
ify7:
hi can you share details. I have an issue with my "2000W must power inverter" and have not been able to get support. i don't mind in home service (if possible) as the inverter is wired to the house

Happy new year! Sorry for the late reply because of my busy schedule. My mobile number "08135031951" is in my profile info dear, I respond mainly to serious clients. Thanks
Re: Inverter Users : Lets Have Your Experience by jessicachukwu: 2:06pm On Jan 11, 2015
I would like to recommend you a website http://0700inverters.com there one can get complete information about different types of inverters.
Re: Inverter Users : Lets Have Your Experience by kiekie1(m): 2:34pm On Jan 11, 2015
HAPPY NEW YEAR PALS !!!

Latest Model EP SOLAR " i TRACER " charge controllers now in stock
60a 12v/24v/36v/48v MPPT CC with 150v max "Load control feature,inbuilt LCD display, internet kit, ethernet cords and cd rom @ 90k
EP Solar 30a PWM CC @ 30k

Trojan USA Flooded deep cycle batteries still in stock .. J185p 12v 205a

Perlight solar panels 80,140w monocrystalline , 200w & 240w polycrystalline panels also in stock

3.5kva 24v "lcd display and 70a adjustable max charge current" / 2kva 24v "20a max charge current" / 1kva 12v "20a max charge current" Pure sinewave inverters (1 year warranty).

Safe Power 1.5kva 24v Indian Pure sinewave Inverter

Call Sir Frankie "08135031951" now for detailed enquiry, supplies, home delivery and waybill outside Lagos city ... THANKS !!

Re: Inverter Users : Lets Have Your Experience by dave07(m): 10:02pm On Jan 11, 2015
It's been quite a while but the thread keeps getting better
My final question. I have a load of 1.5 kW that I would want to power for 10 to 11 hrs. I have a 3.5kVa inverter (48V) and 4 12V 200AH deep cycle batteries connected in series. How long would it last?
PS Talking through how the answer is arrived at would be very helpful. I might want to play around.
With a load of 1.5kW your draw at the dc side is 31.25A, if you continue with this load for one hour, you'd have drawn 31.25Ah out of your 200Ah bank. Neglecting losses due to battery discharges and cabling and assuming you want to maintain a DoD of 50%, in order to lengthen your battery life, then you can only run this load successfully for 3hrs or 5hrs (worse case scenario & jettisoning DoD) before your inverter shuts down.
To achieve your goals you would need at least another parallel string of 200Ah 48V to bring your storage Ah to 400Ah minimum.
Alternatively you may work on your load, take lighting and some other load to dc with very low consumption, so that your overall consumption is considerably reduced.
Remember power at the dc side of your inverter=power at the ac side (theoretically speaking and assuming minimal losses) consequently current draw is a ratio of rated power to voltage. hope this helps

1 Like 1 Share

Re: Inverter Users : Lets Have Your Experience by folamingo: 4:30pm On Jan 24, 2015
Please i want to know if it is possible to use the LG gen cool inverter V air conditional on gen mode of 0.9kva on my Prag 2.5kva inverter with 4 prag 200mah batteries? I expect your response house.. Thanks

1 Like

Re: Inverter Users : Lets Have Your Experience by jonescyras(m): 11:13am On Jan 28, 2015
Hello roomies,......I need an inverter that could power my hp laptop (14 inches) + a standing fan + 1 energy bulb!.....I'm thinking about purchasing a portable generator but also concerned with the costs of fuel!.....I'm a student, and I could charge the inverter with my school gen!.....needs reply
Re: Inverter Users : Lets Have Your Experience by femiolorun(m): 6:20pm On Jan 29, 2015
jonescyras:
Hello roomies,......I need an inverter that could power my hp laptop (14 inches) + a standing fan + 1 energy bulb!.....I'm thinking about purchasing a portable generator but also concerned with the costs of fuel!.....I'm a student, and I could charge the inverter with my school gen!.....needs reply

as a student i guess you generator will be i pass my neighbor, if that is what you have and there is no regular PHCN, charging will be difficult for you most especially when its down. at times it takes 12 hours to charge a battery to full. think twice
Re: Inverter Users : Lets Have Your Experience by femiolorun(m): 6:22pm On Jan 29, 2015
folamingo:
Please i want to know if it is possible to use the LG gen cool inverter V air conditional on gen mode of 0.9kva on my Prag 2.5kva inverter with 4 prag 200mah batteries? I expect your response house.. Thanks

pls clarify the above character
Re: Inverter Users : Lets Have Your Experience by femiolorun(m): 6:25pm On Jan 29, 2015
Deluxe8000:
i have 20ah battery charger to charge my 200ah battery but it seems it discharges when main phcn source is off cos its meter reads even when phcn source is off. pls wat can i do to stop it from discharging?

the discharge is minimal but if you feel bothered, you have to do a manual work often and often buy removing the terminal to avoid discharge
Re: Inverter Users : Lets Have Your Experience by femiolorun(m): 6:31pm On Jan 29, 2015
johnny4u2:

John on December 20, 2014 at 5:52 am
reply

Hi,
Your replies and inputs are highly informative.
I have a 5KVA and a 3.5KVA inverter used to power different sections of my house. Each is having 8 numbers and 4 numbers 200Ahr batteries respectively. What is the minimum rating of a generator set that I need to charge these inverters separately and also together?

im sure the both will be at 15 amp maximum charging current, say the inverter will draw btw 15amp to 17amp when the battery is low, we are saying 30amps to 35amps at low voltage, the current tends to reduce as battery voltage rise to full voltage. so considering fridge an freezer on get 7 kva generator minimum

1 Like

Re: Inverter Users : Lets Have Your Experience by jonescyras(m): 9:05pm On Jan 29, 2015
femiolorun:


as a student i guess you generator will be i pass my neighbor, if that is what you have and there is no regular PHCN, charging will be difficult for you most especially when its down. at times it takes 12 hours to charge a battery to full. think twice
I woundnt have any problem with charging the battery!....could you pls tell me the power inverter+battery needed to power a laptop+ 1 fan + 1 energy bulb!.....and lastly, how long will the inverter last before I charge it again?......thanks so much!!!!!
Re: Inverter Users : Lets Have Your Experience by folamingo: 9:01am On Jan 30, 2015
femiolorun:


pls clarify the above character

ok, I have a 2.5kva prag inverter with 4 200A batteries. I recently heard about an LG 1HP AC that can work at 0.9kva using a generator mode feature on it. In order words reducing the start up power consumption that normal traditional AC exhibit.

My question is does the generator of 2.5kva and the inverter of 2.5kva operate in the same manner, and would it be safe to connect the LG 1HP AC that has the feature of Generator mode to the inverter?

Thanks

1 Like

Re: Inverter Users : Lets Have Your Experience by femiolorun(m): 9:08pm On Jan 30, 2015
folamingo:


ok, I have a 2.5kva prag inverter with 4 200A batteries. I recently heard about an LG 1HP AC that can work at 0.9kva using a generator mode feature on it. In order words reducing the start up power consumption that normal traditional AC exhibit.

My question is does the generator of 2.5kva and the inverter of 2.5kva operate in the same manner, and would it be safe to connect the LG 1HP AC that has the feature of Generator mode to the inverter?

Thanks


the 2.5kva inverter will run your ac well, adding the start up consumption you get up to 1500w and you are left with 500watt to plat with, but if you say it doesn't consume better for you. inverter and generator produce same voltage, frequency rating but mode of operation is different. if you are sure abt the ac parameter you said go ahead
Re: Inverter Users : Lets Have Your Experience by jonescyras(m): 9:30pm On Jan 30, 2015
I'm about purchasing this laptop power bank called "CT ALL IN ONE 96000mah laptop POWER BANK"....has anyone used this before, pls would you recommend it,I have only planned to use it with a laptop alone. Not with other electronics attached!.....thanks

Link

www.joshnka.com/index.php?id_product=8&controller=product

Though the one in the link is a refurbished one or used!....I am purchasing a new one at
14k.
Re: Inverter Users : Lets Have Your Experience by leo2008: 10:56am On Feb 02, 2015
folamingo:


ok, I have a 2.5kva prag inverter with 4 200A batteries. I recently heard about an LG 1HP AC that can work at 0.9kva using a generator mode feature on it. In order words reducing the start up power consumption that normal traditional AC exhibit.

My question is does the generator of 2.5kva and the inverter of 2.5kva operate in the same manner, and would it be safe to connect the LG 1HP AC that has the feature of Generator mode to the inverter?

Thanks


hello...have you tried the setup u wrote above, because that is what am planning to do....how long does the inverter last with the gen cool ac on......and how long does it take the inverter to charge the batteries back
Re: Inverter Users : Lets Have Your Experience by Druss(m): 10:50pm On Feb 21, 2015
dave07:
It's been quite a while but the thread keeps getting better

With a load of 1.5kW your draw at the dc side is 31.25A, if you continue with this load for one hour, you'd have drawn 31.25Ah out of your 200Ah bank. Neglecting losses due to battery discharges and cabling and assuming you want to maintain a DoD of 50%, in order to lengthen your battery life, then you can only run this load successfully for 3hrs or 5hrs (worse case scenario & jettisoning DoD) before your inverter shuts down.
To achieve your goals you would need at least another parallel string of 200Ah 48V to bring your storage Ah to 400Ah minimum.
Alternatively you may work on your load, take lighting and some other load to dc with very low consumption, so that your overall consumption is considerably reduced.
Remember power at the dc side of your inverter=power at the ac side (theoretically speaking and assuming minimal losses) consequently current draw is a ratio of rated power to voltage. hope this helps

It helped a lot. I had made similar calcs and reduced my load to about 800W (TV, laptop, 2 fans and one monitor plus some small appliance) and for the first seven weeks I used this for greater than 10 hrs. For some reason however I am now only getting 5 hours with the same arrangement. Even with the TV and fans only on I am getting 8 hrs. I am hoping that the inverter guy didnt install crap. I have called him to change the batteries as I suspect one has failed and as they are still under warranty but he is dodging me (typical). I am very shocked as I wasnt expected this until at least a year.

Setup

3.5KVA 48V Mopower inverter
4 12V 200AH Deep Cycle Zenith batteries

I also asked him to install a battery equaliser which he refused to initially and which he is blaming for my misfortunes.
Re: Inverter Users : Lets Have Your Experience by zeestone99(m): 12:18pm On Feb 23, 2015
Contact us for ur inverter n solar installations.... Get expert installation from us, a trial will convince u n for dose dat called us for installation thnk u 4 giving us a trial n we r glad we surpassed ur expectations
Re: Inverter Users : Lets Have Your Experience by c0ogumo(m): 2:26pm On Feb 23, 2015
Please visit our website www.solardepotng.com for affordable inverters and accessories
Re: Inverter Users : Lets Have Your Experience by raii: 3:50am On Feb 27, 2015
My 3 5kva luminous inverter backed by 4 batteries usually powers my fridge, tv and fans dor two days when fully charged. Now it doesn't power all these items for 24hrs except the fridge is off. What could cause this.

I have had the inverter for 8months.
Re: Inverter Users : Lets Have Your Experience by c0ogumo(m): 7:43am On Feb 27, 2015
raii:
My 3 5kva luminous inverter backed by 4 batteries usually powers my fridge, tv and fans dor two days when fully charged. Now it doesn't power all these items for 24hrs except the fridge is off. What could cause this.

I have had the inverter for 8months.

To be able to help, please supply the following info:

What is your inverter max charging current?
Is your system voltage 24Volt or 48Volt?
What is the capacity of your four batteries? 12V 200AH ?
How many hrs/day do you have NEPA light on average?
Do you have a solar system to charge your batteries?
What is the make and voltage for each battery?

What is the power consumption for each item mentioned above
TV, Fridge, Fan in watts?

Thanks

www.solardepotng.com
Re: Inverter Users : Lets Have Your Experience by temizeee(m): 7:44am On Feb 27, 2015
raii:
My 3 5kva luminous inverter backed by 4 batteries usually powers my fridge, tv and fans dor two days when fully charged. Now it doesn't power all these items for 24hrs except the fridge is off. What could cause this.

I have had the inverter for 8months.
possible problem:your battery is degrading
question: when did u installed the 4 batteries?
possible solution: you will replace the battery according to the spec of the present.
Re: Inverter Users : Lets Have Your Experience by kiekie1(m): 9:36pm On Feb 28, 2015
HURRY HURRY HURRY !!!!!!

1. USA TROJAN T105-RE Premium Line Flooded Lead Acid Battery 6V (225AH)20hr Rate ..... @ 34k

2. USA TROJAN J185P-AC Signature Line Flooded Lead-Acid Battery 12V (205AH) 20hr Rate .... 65k

PRAG pure sinewave power inverter " Inbuilt 70a Peak Charging Current" .... (In Stock)

POWERSTAR LIGHT 2kw 12v, 3kw 24v, 4kw 48v, 5kw 48v, 6kw 48v pure sinewave power inverter " Inbuilt 35/0a Peak Charging Current" .... (In Stock)

Latest Model EP SOLAR " i TRACER " charge controllers now in stock
60a 12v/24v/36v/48v MPPT CC with 150v max "Load control feature,inbuilt LCD display, internet kit, ethernet cords and cd rom ..... 90k

EP Solar 30a PWM CC ..... 30k

PERLIGHT SOLAR MONO & POLYCRYSTALLINE PANELS (12v 80w to 24v 290w) ...........now available

MERCURY & BLUEGATE 3.5kva 24v Pure sinewave lcd inverter (inbuilt 70ahm intelligent max charger for large battery bank) #charges with Gen unlike Cyberpower,, easy installation unlike cyberpower,,powers heavier appliances"inductive/resistive/motors/rectifier loads" with the help of 40 inbuilt powerful mosfets driving out o/p capacity of 2500w and max surge protect of 7500w under 0.7 power factor.......... 90k


All our products come with 1 year Warranty.

CALL SIR FRANKIE NOW FOR SUPPLIES / WAYBILLS +2348135031951 .... THANKS
Re: Inverter Users : Lets Have Your Experience by bobojoshua(m): 3:52pm On Mar 01, 2015
sleekman:


Ultimate AGM
Hoppecke (I hope I got d spelling right) -dis is a German product and its badass
Hipower Lithium -this is another very good battery.
Haze Solar
Lifeline
Trojan
Synergy

Pls note batteries on this list last btw 5-10yrs depending on its use. 100Ah Hoppecke 4 instance equals 2-3 chinese equivalents

(1) (2) (3) ... (22) (23) (24) (25) (26) (27) (28) ... (170) (Reply)

How To Hack Any Wifi Network Password Using Cmd / Huawei USB Modem Unlocker - Download Here! / Post Your Computer (PC) Troubles Here.

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health