Welcome, Guest: Register On Nairaland / LOGIN! / Trending / Recent / NewStats: 3,206,749 members, 7,996,665 topics. Date: Thursday, 07 November 2024 at 01:26 PM |
Nairaland Forum / Entertainment / TV/Movies / Satellite TV Technology / Solar Energy, A Complement To FTA (2374529 Views)
UPS Back-up, Also A Complement To FTA / FTA Frequency / Cctv Installation A Complement To Fta And Solar Energy (2) (3) (4)
(1) (2) (3) ... (93) (94) (95) (96) (97) (98) (99) ... (1850) (Reply) (Go Down)
Re: Solar Energy, A Complement To FTA by kiekie1(m): 12:11am On May 29, 2015 |
Saipro: Thanks Sir ! |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 12:21am On May 29, 2015 |
hrguru13: Hmmmn Gbagada axis! Deeper life area u mean or Bariga side ? Seeing is believing! Holla for specialised services 08135031951 ..... Thanks ! 1 Like |
Re: Solar Energy, A Complement To FTA by durodee(m): 8:06am On May 29, 2015 |
Harvest has been good since my upgrade. I have 2 settups: 6 X 255W (1.53KaW total ) solarworld Mono panels connected 3X2 to a 60amp MPPT CC to an 800amp 24v battery bank that generated 7.7kWh/day and another 6 X 180 W Poly (1.08kw) connected 1X6 through a 30amp MPPT CC generating only about half of the bigger system. The Inverter inbuilt 50amp PWM CC is now redundant but available as backup any time. Wants to dabble into thin film panels as soon as I have chance, I have a friend who keeps swearing on them! . My connections are untidy, hope to get better with time. 1 Like
|
Re: Solar Energy, A Complement To FTA by Boss13: 9:17am On May 29, 2015 |
kiekie1: Are you very good? |
Re: Solar Energy, A Complement To FTA by shithapuns: 9:54am On May 29, 2015 |
bigass: nope, though most inverters are intelligent...ie if solar and nepa are hooked up...it usually uses solar to charge, but disconnects solar when phcn/gen comes |
Re: Solar Energy, A Complement To FTA by shithapuns: 10:08am On May 29, 2015 |
hrguru13: i think there is an error somewhere..u got it mixed up. ur charge controller is 30amp....n u say current flunctuates btw 54 n 56 amps.....also 3 panels of 280w 24v cannont generate upto 54amps...not possible 2ndly for the panels to be hooked up in series, being 24v panels = 72volts minimum ....that implies ur charge controller is likely mppt 3rdly i think u mixed up ur current and voltage values.....its likely the other way round .its likely voltage is 54 - 56v and current 24.4 - 25.7amps such a system cannot run 24hrs............though i doubt u watch tv 24hrs...nor the 3 fans run 24/7 confirm the wattage of ur tv though...cos plasma flat screen tv consume up to 300w while thier led counterpats is about 140w for a 42 - 46 inch tv . there are too many variables/unknown in ur case.its best u get a professional to come look at it....or a forum member in lag cud stob by n give u guys a hand 2 Likes |
Re: Solar Energy, A Complement To FTA by JUO(m): 12:54pm On May 29, 2015 |
shithapuns:I think you are right. If the system is producing between 24-26amps the performance is not bad for a 800w setup. The lady is not telling us everything. The TV maybe plasma and there maybe fridge on this system. Madam please show us pictures and list all the load on the inverter |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 3:26pm On May 29, 2015 |
durodee: Nice ! I can see you are really enjoying the EP SOLAR 60a MPPT CC ... Cheers! |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 3:30pm On May 29, 2015 |
Boss13: Hmmn |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 3:52pm On May 29, 2015 |
HURRY HURRY HURRY !!!!!! USA TROJAN T105-RE Premium Line Flooded Lead Acid Battery 6V (225AH)20hr Rate ..... @ 40k each (just 4pcs remaining) USA TROJAN J185P-AC Signature Line Flooded Lead-Acid Battery 12V (205AH) 20hr Rate .... "ALMOST OUT OF STOCK". @ 75k each USA Trojan IND17-6V Industrial Line Flooded Lead Acid Battery 6v (1202Ah) 100hr rate... @ 280k USA OUTBACK mppt charge controller (FM 80) The EP Solar "I TRACER" 60a mppt controller is just #95k compared to Morningstar price and has excellent features like: -inbuilt LCD display, -high efficiency energy harvest with advanced mppt algorithm -dual core (ARM CPU+DSP) control architecture -run data and event recording -multi phase synchronous rectification tech realizing peak conversion efficiency 98% -high reliabilty including reverse connection, over current and load short protection etc -diversified load control mode -monitor software supplement and firmware update -extensive communication capabilities (RS232, RS485 with modbus protocol, CAN bus extendable) MUST POWER / POWERSTAR LIGHT 2kw 12v, 3kw 24v, 6kw 24v, pure sinewave LCD power inverter " Inbuilt 35/70a Peak Charging Current" .... (In Stock) Bluegate pure sinewave inverters (1kva 12v & 2kva 24v) .... In Stock All our products come with 1 year Warranty. For best affordable prices,contact Smartcell Global Services,Lagos Nigeria. Simply call Sir Frankie "08135031951" for purchase,fast delivery and waybills .. Thanks !!! 1 Like |
Re: Solar Energy, A Complement To FTA by hrguru13: 6:06pm On May 29, 2015 |
Sorry, been really busy. My husband has corrected me on a few points (he's not on naira land). The panels are in parallel, the controller is pwm, my TV is 73w( 32 inch Sony Bravia). I saw the figures myself ie the voltage and current figures on the controller when it was on. I hv attached pics of d controller, it is off at d moment though as it has been disconnected . also hv a pic of d inverter (cyberpower). Tanks guys for d responses.
|
Re: Solar Energy, A Complement To FTA by Saipro(m): 7:15pm On May 29, 2015 |
Things are a bit clearer now. Apparently, there's little (if anything) wrong with your system. I think we have an I/O mismatch (Input/Output) on our hands. It's not just the load on the system that matters but for how long the load is on and how the load varies with time (daytime load vs nighttime load) and other seemingly minor details which can bedevil a perfectly good RE system. @Frank (kiekie1): It's nice you've changed the name on your EP Solar CC as it's truly "iTracer" and not "eTracer". By the way, they're almost identical if not for the load output which boosts the iTracer's specs. |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 8:07pm On May 29, 2015 |
Saipro: Well noted Sir ! |
Re: Solar Energy, A Complement To FTA by JUO(m): 8:10pm On May 29, 2015 |
hrguru13:to be frank with you 3 280w in parallel on mppt cannot produce 600w not to talk of pwm. I think the problem here is the cc because I have had similar problem with pwm, initially I was thinking my panels were bad. Imagine charging battery for a whole day and at the end you get 0.2v, is annoying. I was using 3 130w in parallel with a 30amps pwm cc this thing can't power my 80w fridge. I was surprised when I got 20amp mppt this was the result
|
Re: Solar Energy, A Complement To FTA by JUO(m): 8:41pm On May 29, 2015 |
Contact kiekie or Richmond for a good cc and change the connection . Presently I have similar setup and I get 4kwh sometimes
|
Re: Solar Energy, A Complement To FTA by c0ogumo(m): 9:40pm On May 29, 2015 |
6300W Solar installation in Ibadan 12 x 275 Solarworld panels 12 x 250 Renogy Panels 2 x Xantrex xw mppt 60 1 x Xantrex xw6048 1 x Xantrex SCP 1 x Xantrex PDP 8 x Trojan IND17-6V More pics to follow The Solar Depot Nigeria www.solardepotng.com
|
Re: Solar Energy, A Complement To FTA by hrguru13: 11:11pm On May 29, 2015 |
JUO:Thanks @JUO. Frm ur answer and other comments on d thread, I agree that an mppt cc will b a better option than wat we hv nw. Do u think dt's d only problem? |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 11:17pm On May 29, 2015 |
c0ogumo: Nice one Bro! You are good to go , remember safety 1st..Also include AC & DC surge protectors ok? keep it up |
Re: Solar Energy, A Complement To FTA by i1: 4:18am On May 30, 2015 |
Thanks in advance. Please I want to know how much it will costs to setup a solar Inverter system to power the following 1. My television and dvd/home theatre 2. About 8 bulbs. 3. 3 standing fans for night use. 4. Charging laptops and phones. This fuel scarcity chai... 2 Likes |
Re: Solar Energy, A Complement To FTA by Saipro(m): 2:42pm On May 30, 2015 |
c0ogumo: Simply awesome. How I wish I had your batteries! ..... even if just four of them. The wonders I'd be capable of ...... |
Re: Solar Energy, A Complement To FTA by Saipro(m): 2:50pm On May 30, 2015 |
JUO: Didn't say the system is optimal or perfect. Merely sufficiently set up to be functional. There's always room for improvement. Who knows the orientation of her PV panels. Or the wiring set up (Ac side or DC side or both could be less than optimal). A lot of factors. What I meant is, with her equipment, things could be rearranged to work. However, in RE systems, the rule of thumb: work out your working load => size your battery bank to match your needs (if you require a bank, that is) => have PV array capable of recharging your battery bank (as a minimum requirement). |
Re: Solar Energy, A Complement To FTA by Saipro(m): 2:57pm On May 30, 2015 |
c0ogumo: As much as I admire your setup, upon closer inspection, there appears a fundamental flaw (pretty common in RE): your PV array is somewhatinadequate for maintaing your bank - unless you plan to sparingly draw energy from the battery bank. Even then, you'd have to take an entire day or two to charge back if you somehow draw up to 50% DoD. A given however, is the fact that your array is capable of supplying enough charge current to keep your batteries "happy". I'm quite curious as to the application to which this setup would be attending to. You could PM me if you'd prefer to keep things discrete. PS: Pardon my overly enthusiastic and unsolicited comments but my inferences are based on the fact that your setup looks like something meant to power equipment with either high-surge starting current or equipment with steady but high power consumption. |
Re: Solar Energy, A Complement To FTA by Boss13: 5:01pm On May 30, 2015 |
Saipro: Why do you say that because it is not monocrystalline Panels? |
Re: Solar Energy, A Complement To FTA by bigass(f): 8:53pm On May 30, 2015 |
shithapuns: Do you still have to pass the wires from the Solar panels through the inverter? Or just directly from the CC to the battery bank. |
Re: Solar Energy, A Complement To FTA by RipVanWink: 9:20pm On May 30, 2015 |
bigass: see how it goes solar panel -- charge controller -- inverter then connect ur inverter normally, with the positive n negative leads on the battery, same place you terminated the wires from the charge controller note: the charge controller and inverter must have same operating voltage -- 12v/24v/48v , if its an mppt charge controller, even better, as you can have upto 150v dc coming in from the panels, but once u programm ur cc to the inverter voltage...then u r still good |
Re: Solar Energy, A Complement To FTA by bigass(f): 12:05am On May 31, 2015 |
RipVanWink: The bolded part is confusing. You said wire from CC ends in inverter then you said on battery where the wires from CC ends. From your explanation the wire from CC ends in the inverter. Where on the inverter. The only input source I see on my inverter is for direct electricity from PHCN or GEN. Then the wires to the battery. I thought that the charge controller send the power to the battery. From your explanation, it means you can not use both sun and phcn to charge |
Re: Solar Energy, A Complement To FTA by bigass(f): 12:38am On May 31, 2015 |
Sorry ooo Please we want to add solar panels to our inverter. But I am more confused about how these things work. We use 1.5 Luminous inverters with 2 200AH batteries. How many solar panels would I need. How do i know if my inverter can work with solar panels. Aside panels what else would I need. How do you prevent over charging with solar. Can solar and PHCN work together in charging battery bank. How do you run the wires from the solar panel to the battery alongside with ones from phcn? |
Re: Solar Energy, A Complement To FTA by cardoso111(m): 3:33am On May 31, 2015 |
bigass: You need to tell us what equipment that you have in your home |
Re: Solar Energy, A Complement To FTA by Saipro(m): 6:52am On May 31, 2015 |
bigass: Or at least give an estimate of your average (slight overestimation though) of your daily power load. That way, your battery bank can be deemed adequate or not and your panels can be matched to replenish the power drawn from your bank. But that's the oversimplified version |
(1) (2) (3) ... (93) (94) (95) (96) (97) (98) (99) ... (1850) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: idsolar(m) and 2 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 76 |