Re: Solar Energy, A Complement To FTA by Boss13: 1:38pm On Jun 02, 2015 |
salam12: I have a 5KVa inverter and I believe it is a 48V inverter Wiring arrangement of panels - I don't know how to go about this Wiring arrangement of Batteries - I think it is connected in series something like that Pictures - I cannot provide pictures because I am not at home. Thanks |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 1:43pm On Jun 02, 2015 |
Boss13: We need to have an idea of how the panels r wired to be sure they are wired properly...or at least a picture of ur charge controller in action...showing the solar harvest. ur inverter being 48v, and ur charge controller being pwm , this implies that ur panels will be connected in series/parallel to still give 48v ~`60v output since you cant provide any/all of this info...ur best option is to take a professional to ur home to inspect and advice you on next step |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 1:53pm On Jun 02, 2015 |
Boss13: connecting just the solar to inverter, and not having batteries means that you dont store the solar harvest...once the sun goes down..then ur system will flat line......u already hv batteries so ur system shud be hooked to the panels tru the charge controller. mppt doesnt cause any overcharging...its just that its more expensive, so if the installer is fraudulent...he will collect money for mppt usually 100k n above for 60amp mppt n then buy 60amp pwm..wch wud be around 40k or so. u said ur solar panel charges at 66v?...this i assume is the output from the panels wch it sends to the charge controller...wch might be 24v panels hooked up in series...cos even though the panel is written 24v..it usually produces upto 36v in bright sunlight n maybe 30v on a normal day your issue is complex, u dont seem to hv much idea abt the connections, so trying to troubleshoot the fault from the internet is mission impossible,,,,,,,i blv you hv spent a lot of money already..and its still not working...this is the time to invite a profesional to go tru ur setup.. pbsolar /richmond are proffesional installers...contact them, they would help you correct ur setup and enjoy maximum satisfaction for ur money |
Re: Solar Energy, A Complement To FTA by NoMoreTrolling: 3:40pm On Jun 02, 2015 |
Where can I get a desulphator? I also need an affordable panel that can put out more than 24V on average to push charge through to a 24v battery setup. |
Re: Solar Energy, A Complement To FTA by Saipro(m): 7:33pm On Jun 02, 2015 |
abunafiu: Indeed, you did mention him having a backup plan for charging the baterries. That quells my fear on the three-day cloudy spells that love to hit without warning. Kudos! He however has been evasive on load estimates. I guess he has his reason(s). Cheers! |
Re: Solar Energy, A Complement To FTA by chris81964(m): 9:58pm On Jun 02, 2015 |
Boss13: Before you change your batteries, monitor your harvest and consumption. You have 300 AH in batteries which should take you through the night with the refrigerator and freezer switched off. You can power a few fans and a few lights through the night. Your panels add up to 2300 I am sure there is a reason for using the 300 W panel. At 50 V your batteries are not really fully charged. They should float between 52 and 54. During the bulk and absorb phase they should see between 58 and 60 Volts. Check the settings on your controller and make sure they match the battery type. I use MPPT chargers, and for the amount of money you spent on the panels and batteries you should have sprung for a really good one. It is the difference between getting your batteries to last a long time and replacing them in a very short period of time. I have had enough issues with cheap controllers and failed batteries that is makes economic sense to buy better controllers
|
Re: Solar Energy, A Complement To FTA by NoMoreTrolling: 10:09pm On Jun 02, 2015 |
I'm really jealous of you guys men! I've been thinking this up for like 2 years now, but it's time to act. Tony Stark mode activated |
Re: Solar Energy, A Complement To FTA by Boss13: 10:17am On Jun 03, 2015 |
earthrealm: I gave the installer N80,000 for the solar controller, actually it is the third controller I am buying and I specifically told him MPPT and he told me MPPT causes overcharging. How can I reach richmond or pbsolar? |
Re: Solar Energy, A Complement To FTA by Boss13: 10:25am On Jun 03, 2015 |
chris81964: Thank you so much. I made a terrible mistake. I contacted dubious and incompetent installers. The batteries I have now cannot charge more than 50V through solar and sometimes I use external charger which charges it to 53.7v. However, immediately I put on my load, it drops instantly to 50V. I have been told the batteries are fairly used and sold to me as new ones by wicked Alaba traders. The trader has promised me new ones tomorrow. I have spent so much and I cannot concentrate any longer. My inverter went off this morning by 6:01am . I need assistance |
Re: Solar Energy, A Complement To FTA by hrguru13: 11:49am On Jun 03, 2015 |
"BEEN TRYING TO POST THIS SINCE LAST W...SPAM BOT WAHALA, HAD to use pictures" @earth realm, thanks a bunch bro. Your help is much appreciated. Will give feedback as soon as we make d suggested corrections. Thanks again. |
Re: Solar Energy, A Complement To FTA by Saipro(m): 1:34pm On Jun 03, 2015 |
Boss13: If your batteries are flooded wet cell baterries, all might not be lost yet. A desulphator could still glean some meaningful life from those batteries. I've done lots of reviving of flooded and even VRLA batteries. Gel batteries aren't so responsive to attempts at reviving. |
Re: Solar Energy, A Complement To FTA by simonolowo(m): 2:10pm On Jun 03, 2015 |
Boss13:Next time make sure d voltage and current rating of d ba3 is tested wit a meter 4 u 2 c |
Re: Solar Energy, A Complement To FTA by salam12(m): 5:09pm On Jun 03, 2015 |
Boss13: All hope not yet lost. As previously stated in one of the posts, charging 48V system with 50V is total waste of time and your external charger barely putting out 54V to the batteries will never get the batteries fully charged. The more reason battery voltage dropped to 50V moment the system is loaded. Search for pbase solar on facebook, you will get his contact details there. |
Re: Solar Energy, A Complement To FTA by Boss13: 5:26pm On Jun 03, 2015 |
Saipro: I think my batteries are gel batteries |
Re: Solar Energy, A Complement To FTA by Boss13: 5:27pm On Jun 03, 2015 |
salam12: Ok thanks off to Facebook |
Re: Solar Energy, A Complement To FTA by Boss13: 7:15pm On Jun 03, 2015 |
Thanks guys PBase Solar has been to my place. I think my installation is pretty messed up. I have to revamp it entirely |
Re: Solar Energy, A Complement To FTA by Penuelseun(m): 4:05am On Jun 04, 2015 |
Trippledots:well-done bro, can u please expatiate on ur number four point. Thanks 1 Like |
Re: Solar Energy, A Complement To FTA by Trippledots(m): 4:14am On Jun 04, 2015 |
Penuelseun: Thanks. 'Another type of hydropower technology is called pumped storage. In a pumped storage plant, water is pumped from a lower reservoir to a higher reservoir during off-peak times when electricity is relatively cheap, using electricity generated from other types of energy sources. Pumping the water uphill creates the potential to generate hydropower later on. When the hydropower power is needed, it is released back into the lower reservoir through turbines. Inevitably, some power is lost, but pumped storage systems can be up to 80 percent efficient. There is currently more than 90 GW of pumped storage capacity worldwide, with about 20 percent of that in the United States. ' -culled from http://www.ucsusa.org/clean_energy/our-energy-choices/renewable-energy/how-hydroelectric-energy.html#.VW_A9HAo8b0 |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 7:39am On Jun 04, 2015 |
Trippledots: IS THIS REALLY FEASIBLE IN PRESENT day nigeria/UR HOME?....lets try to keep it simple -- KISS |
Re: Solar Energy, A Complement To FTA by i1: 9:05am On Jun 04, 2015 |
i1:House please answer me. I need an idea. Thanks |
Re: Solar Energy, A Complement To FTA by Trippledots(m): 12:17pm On Jun 04, 2015 |
earthrealm: Was sharing a thought. that's all |
Re: Solar Energy, A Complement To FTA by simonolowo(m): 12:36pm On Jun 04, 2015 |
i1:I need to knw d wattage of each of ur appliances n d hours u want dem ON and also ur state of location all dis wil help me in my design |
Re: Solar Energy, A Complement To FTA by simonolowo(m): 1:01pm On Jun 04, 2015 |
earthrealm:pls hw much per unit |
Re: Solar Energy, A Complement To FTA by simonolowo(m): 1:18pm On Jun 04, 2015 |
Pls guys which of dis is correct. Array peak amp hr= total wat-hr/eff. Of ba3/sun shine hr Or Array peak amp hr = average amp hr per day/eff. Of ba3/ sun shine hr Urgent pls |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 1:45pm On Jun 04, 2015 |
i1: this issue has been discussed extensively...read through especially the last 4 pages.....nobody gets any kobo for the advice we take time to write here.....and i just posted something very similar to your query again, just in the last page or so for some1 to even want to attemp to answer ur questions again.....then you need to state the wattage of all those ur equipment, state how many hours u want to run them etc...divide them into day and night loads |
Re: Solar Energy, A Complement To FTA by simonolowo(m): 6:51pm On Jun 05, 2015 |
[quote author=GeorgeD1 post=7591960]litaninja, sorry for replying so late. your problem is a simple one. since you already carried out an inventory of your estimated power consumption, your already on the right track to solving things. now here we go: 1) total (it equipment) power consumption = 2000w 2) total expected run time/day = 14hrs 3) watt/hours per day (2000*14) = 28,000watthours 4) assuming your using a 48v battery bank system voltage, you will need a 28,000/48 = 584ah battery bank if your using a 200ah battery, you need 4 batteries in series and at least 3 battery banks wired in parallel, i.e 12pcs 200ah batteries for your equipment to run without interuption. 5) you will need a minmum 3.5kv inverter to carry your load. for recommendations, make sure you buy original zenith 200ah batteries. personally that's what i use and i been using them close to 4yrs now without fail. also, buy either nexus, sukam or cyberpower 3.5kva inverter for reliability. also, you will no longer need those apc backup ups anymore. your inverter system acts as a better and more robust ups system with longer storage. To me I will recommend, 10units of 48v200Ah battery connected in parallel and 3.5KVA inverter if u are 2 run ur system 4 14hrs. I put dis in2 consideration in my calculation. 1.25 tolerance, ba3 efficiency 80%,dod 50% |
Re: Solar Energy, A Complement To FTA by chris81964(m): 9:23pm On Jun 06, 2015 |
There can be a series of things going on. 1. Your controller should be able to charge to the higher voltage that I mentioned. When the batteries are bad, they do't really resist a charge. Inability to get to 58 or 59 V is a function of the charger not the batteries. Do you have the right voltage from your PV? What type of charge controller do you have and how many amps is it? 2. What type of an external charger are you using and for how long do you charge the batteries? Boss13: |
Re: Solar Energy, A Complement To FTA by chris81964(m): 9:26pm On Jun 06, 2015 |
There can be a series of things going on. 1. Your controller should be able to charge to the higher voltage that I mentioned. When the batteries are bad, they do't really resist a charge. Inability to get to 58 or 59 V is a function of the charger not the batteries. Do you have the right voltage from your PV? Check the harvest from the panels. That will give you a clue. 2. What type of an external charger are you using and for how long do you charge the batteries? Boss13: |
Re: Solar Energy, A Complement To FTA by Saipro(m): 4:36pm On Jun 08, 2015 |
chris81964: Actually, bad batteries will resist a charge. It depends on the cause of the "badness". Damaged cells are certain to cause a flat voltage despite high charging current/voltage. |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 7:01pm On Jun 08, 2015 |
HURRY HURRY HURRY !!!!!! USA TROJAN T105-RE Premium Line Flooded Lead Acid Battery 6V (225AH)20hr Rate ..... USA TROJAN J185P-AC Signature Line Flooded Lead-Acid Battery 12V (205AH) 20hr Rate .... "ALMOST OUT OF STOCK". @ 68k each USA Trojan IND17-6V Industrial Line Flooded Lead Acid Battery 6v (1202Ah) 100hr rate... @ 280k USA OUTBACK mppt charge controller (FM 80) Midnite Solar Surge arrestor "DC & AC Models" ............ @ call for price The EP Solar "I TRACER" 60a mppt controller is simply rugged compared to Morningstar price and has excellent features like: -inbuilt LCD display, -high efficiency energy harvest with advanced mppt algorithm -dual core (ARM CPU+DSP) control architecture -run data and event recording -multi phase synchronous rectification tech realizing peak conversion efficiency 98% -high reliabilty including reverse connection, over current and load short protection etc -diversified load control mode -monitor software supplement and firmware update -extensive communication capabilities (RS232, RS485 with modbus protocol, CAN bus extendable)...@ call for price MUST POWER 2kw 12v, 2kw 24, 3kw 24v,3kw 48v , 6kw 24v,6kw 48v pure sinewave LCD power inverter " Inbuilt 35/70a Peak Charging Current" .... (In Stock) Bluegate pure sinewave inverters (1kva 12v, 2kva 24v, 3.5kva 24v, 5.5kva 24v) .... In Stock All our products come with 1 year Warranty. For best affordable prices,contact Smartcell Global Services,Lagos Nigeria. Simply call Sir Frankie "08135031951" for purchase,fast delivery and waybills .. Thanks !!! 1 Like |
Re: Solar Energy, A Complement To FTA by chris81964(m): 11:51am On Jun 09, 2015 |
I stand corrected. In my experience with bad batteries they will charge very quickly and discharge as quickly. Does the cell have physical damage to cause what you describe? Saipro: |
Re: Solar Energy, A Complement To FTA by Saipro(m): 2:28pm On Jun 09, 2015 |
chris81964: Specifically, I'm referring to sulphated batteries (a consequence of persistent under-charging). That would be flooded, VRLA and AGM batteries (the most common types in RE). You're however correct too as that's one form of failure. |
(1) (2) (3) ... (95) (96) (97) (98) (99) (100) (101) ... (1850) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: S4SOLOMON4(m), Dharyhor, saint2ace(m), olujosh301(m), jameslojohn(m), odimbannamdi(m), Smartslim17
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 89 |