Re: Solar Energy, A Complement To FTA by JUO(m): 7:19am On Sep 28, 2015 |
chris81964:What is he still looking for? |
Re: Solar Energy, A Complement To FTA by abunafiu(m): 8:26am On Sep 28, 2015 |
JUO:I knew this quotation thing will not sattisfy the op. I suggest the op should work with vendors of his choice( many of them have their contacts published here). Feel free to choose if any one disappoints you. I bet you that no vendor will do more than what chris has done. There are many online shops too to buy from. if u check below this page....there's an advertisement from one of our own. So pls op decide on what u want and work closely with your budget. cheers. cc: JohnKester |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 12:10pm On Sep 28, 2015 |
JUO: Juo, that's the point... I actually assumed he has an installer who briefed him on solar tech / alternate power source...I just drove down to lagos today, will definitely offer him discounts whenever he sole wishes to purchase ! Thanks. |
Re: Solar Energy, A Complement To FTA by RipVanWink: 1:43pm On Sep 28, 2015 |
JUO: same clowns that were the first to bypass the prepaid meters of phcn?? hv you forgotten that they were the first to hv prepaid meters installed, n the senators of federal repuplic of nigeria were the same people who bypassed it!!!...abegi leave the clowns alone, they just hv money...........they r not wealthy!...most of them r crass, unrefined, touts...who just packed our collective wealth and r chopping...shege banza to them n thier kind 1 Like |
Re: Solar Energy, A Complement To FTA by JohnKester: 4:37pm On Sep 28, 2015 |
kiekie1: Welcome back to Lagos! Be unassuming, as your assumptions would always, more often than not, be wrong. I hope I can expect to receive your quotation or request for more details, now that you are back to Lagos. So we can kick off the discussions towards the transaction. Cheers. 1 Like |
Re: Solar Energy, A Complement To FTA by weijing3333: 3:40am On Sep 29, 2015 |
I use a 6KW system. The panels, batteries, inverter (PURE SINE WAVE) and the Charge Controller (MPPT) etc |
Re: Solar Energy, A Complement To FTA by JohnKester: 9:50am On Sep 29, 2015 |
weijing3333: 1 Like |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 3:29pm On Sep 29, 2015 |
JohnKester: Noted! Just saw your SMS.. Thanks |
Re: Solar Energy, A Complement To FTA by chris81964(m): 6:09pm On Sep 29, 2015 |
sathob:Some corrections. The panels don't get 7 hours of direct sunshine. That number varies by location. For Lagos the charts say 4.5 on average. For the batteries. You use the system voltage not the individual battery voltage. If you have a 12 24 or 48 volt inverter you divide by the inverter voltage. You also need to build in at least one day of autonomy into your system. And the final and most critical is the size of the battery bank. The minimum size it should be is 2 x your usage. The fastest way to destroy a battery is by completely discharging them and recharging them. Lead acid batteries hate that. You have given the best explanation for System and battery sizing that I have seen in a while. Keep up the good work 1 Like |
Re: Solar Energy, A Complement To FTA by GeorgeD1(m): 4:48pm On Sep 30, 2015 |
DUNKA: hello dunka, apologies for the late reply. i have really been away from the forum for a while now. yes indeed. three years on, my zenith batteries are still performing as new. if i have a choice i will buy them all over again. very soon, it will be time for my yearly 'turn-around' maintenance. i will be posting results of battery nominal voltages which will be used to compare with previous years. |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 5:38pm On Sep 30, 2015 |
HURRY ! HURRY !! DISCOUNT SALES !!!!!! USA TROJAN L16-RE Premium Line Flooded Lead Acid Battery 6V (410AH)20hr Rate ..... @ 75k USA TROJAN J185P-AC Signature Line Flooded Lead-Acid Battery 12V (205AH) 20hr Rate .... "NOW IN STOCK"....@65k Solarworld mono panels 255w ,260w,265w "made in Germany" etc now in stock at very discounted prices......... Latest model 10kva servo stab (AC input range 80V-270V)....... @55k 15kva 3 phase pure copper servo stab.... ..@110k Programmable timer switch with LCD display 220vac 16a........ @4k The EP Solar "I TRACER" 60a mppt controller is simply rugged compared to Morningstar price and has excellent features like: -inbuilt LCD display, -high efficiency energy harvest with advanced mppt algorithm -dual core (ARM CPU+DSP) control architecture -run data and event recording -multi phase synchronous rectification tech realizing peak conversion efficiency 98% -high reliabilty including reverse connection, over current and load short protection etc -diversified load control mode -monitor software supplement and firmware update -extensive communication capabilities (RS232, RS485 with modbus protocol, CAN bus extendable)....@95k MUST POWER 2kw 24, 3kw 24v,3kw 48v ,5kw 24v,5kw 48v, 6kw 24v,6kw 48v pure sinewave LCD power inverter " Inbuilt 35/70a Peak Charging Current" .... (In Stock) JOY and CSUN solar panels (mono crystalline & poly crystalline) .........@ discounted prices for any watt/volt Outback FM 80 ,Midnite MPPT CC.... Telecomm used intelligent battery chargers 24v 60a, 48v 30a. SMA sunny island inverters,SMA multicluster box, SMA mini central ,hoppecke flooded and deep cycle German batteries etc now in stock. Bluegate pure sinewave inverters (1kva 12v, 2kva 24v, 3.5kva 24v, 5.5kva 24v) .... In Stock *AUTHORIZED DEALER SOLAR SHOP LTD PRODUCTS* All our products come with 1 year Warranty. For best affordable prices,contact Smartcell Global Services,Lagos Nigeria. Simply call Sir Frankie "08135031951" for purchase,fast delivery and waybills .. Thanks !!! |
Re: Solar Energy, A Complement To FTA by temizeee(m): 8:17am On Oct 01, 2015 |
Some months ago,a friend seek my help to check his solar setup.he said that his system even shutdown on full sunny day...on getting there, i went up to see d panels of 80watt of 8 pieces,getting to the controller this is what the installer mounted as charge controller. pix......
|
Re: Solar Energy, A Complement To FTA by temizeee(m): 8:29am On Oct 01, 2015 |
Checking the connection,i discovered that the installer connected the 8 panels in series (voc)=20.2 d norminal voltage of each panel is 17.8v+_ i was reading 152.8v from the panel to that tin can(cc), and that is feeding a 24v 800ah deep cycle ba3. I was shocked!!! after i opened the cc here is the view
|
Re: Solar Energy, A Complement To FTA by temizeee(m): 8:41am On Oct 01, 2015 |
So i decided to add more panels which will be sufficient to charge d ba3s,installed 60amp mppt(itracer),30a cc as well all supplied by KIEKIE Now the system is running almost offgrid...went there last week he said he doesn't really care much about public power supply since the upgrade I will advise everyone to be careful of the installer that you call to do installation......i believe the ba3 will probably explode one day or get dead if there wasn't correction... Just an advice tho. D new cc pix follow: 1 Like
|
Re: Solar Energy, A Complement To FTA by temizeee(m): 8:49am On Oct 01, 2015 |
New cc setup
|
Re: Solar Energy, A Complement To FTA by kiekie1(m): 10:58am On Oct 01, 2015 |
temizeee: Been a while Bro! How is the family? Happy independence ... |
Re: Solar Energy, A Complement To FTA by temizeee(m): 12:57pm On Oct 01, 2015 |
kiekie1:doing good o.....i wish you the same. how is business? |
Re: Solar Energy, A Complement To FTA by chris81964(m): 2:44pm On Oct 01, 2015 |
HAPPY INDEPENDENCE day my Nairaland pals |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 3:57pm On Oct 01, 2015 |
temizeee: Biz is cool.. Glory be to God ! I await more transactions from you soon ! Thanks... 1 Like |
Re: Solar Energy, A Complement To FTA by Pharyn(m): 5:31pm On Oct 01, 2015 |
How do you revive a dying Trojan J185? Background: This is the design: 5kVA Indian Inverter (with 20A charging Charging Current @48V). 8 units of Trojan 12V 205Ah (J185). 4 in series. 2 paralleled with the Inverter follow-come cables. Location: Osun State. Installation date: December 2014. Current status: battery low after 45 minutes. House, how can these precious batteries be rescued? The installation was done for my Pastor's house. |
Re: Solar Energy, A Complement To FTA by Pharyn(m): 5:42pm On Oct 01, 2015 |
This is the image of the installation.
|
Re: Solar Energy, A Complement To FTA by kiekie1(m): 6:22pm On Oct 01, 2015 |
Pharyn: That inverter ain't suitable for trojan batteries and there is no solar set up in the picture as posted to supplement maximum charging and flooded battery equalisation ... If you are interested in my rugged 4kw 48v inverter which can equalise those Trojan batteries back to life and maintain optimal electrolyte level, you can contact me via my hotline contact in my profile !! Thanks |
Re: Solar Energy, A Complement To FTA by c0ogumo(m): 6:39pm On Oct 01, 2015 |
Pharyn: 1.) You need a good inverter with 40A-60A charging current and capable of equalizing the Trojan batteries. 2.) The cables are very thin, you need thicker cables. Please visit our website www.solardepotng.com for various inverter options. |
Re: Solar Energy, A Complement To FTA by Barezzi(m): 8:38pm On Oct 01, 2015 |
@temizeee Very shocking indeed! Such a dangerous setup, no protections, exposed high voltage cables... and that looks like the guy's main lounge! If e kill am dem for say na the grandma for village... |
Re: Solar Energy, A Complement To FTA by chris81964(m): 9:02pm On Oct 01, 2015 |
Pharyn: Good choice of batteries. 1. Change the cables. They need to be thicker. (depending on the voltage 35 MM is the minimum). I use 50 MM minimum 2. Get a new inverter or an AC charger 3. Check the specific gravity of each cell 4. Charge them fully. ( your charger has to be able to go through a bulk absorb and float ). Set the bulk at 29.6 5. Run an equalization charge at 31 Volts for 1 hour. This should bring them back if they are not too badly gone. You might have to repeat this many times during the week to recover the batteries. They are tough batteries and can take the abuse. Good luck. This is what happens when you get a quote and then ask someone to beat it and install the same equipment. That is what we say to a lot of people that get quotes from us. Having the recipe does not make you a chef or a good cook. 3 Likes |
Re: Solar Energy, A Complement To FTA by temizeee(m): 9:13pm On Oct 01, 2015 |
Barezzi:na so! |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 10:37pm On Oct 01, 2015 |
who is using a mustpower inverter? am thinking of upgrading my system to a 3kw/3.5kwa inverter, considering either prag 4kw or luminous 3.5kw or 4kw mustpower, i have seen prag and luminous in action...i like them..cooling fans only come on when needed n are not too loud........prag has batt life charge/life indicator.......its mustpower that i dont have any info on. can some1 pls confirm if its not loud/with fans running 24/7 and it has a batt life/charge status in percentage or bars? |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 7:43am On Oct 03, 2015 |
sad news...my morning star 45amp CC has died....my folks in the village hv been complaining that the inverter barely lasts 10mins for a couple of days now...was finally able to go check it, thinking twas the heavy rains or something...but alas in bright sunlight the CC was displaying 0amp,i checked the log and this zero harvest started 10days ago....they reported no ligtening strike...so am rally at loss what might hv damaged it......has anyone experienced this b4?...and any luck in repairing it? the unit is about 21 months old. 4 x 250w 24v renogy panels connected in series. input voltage usually hovers around 130v. system is hooked up to 2 x 200amphr luminous batts, and 1.5kva 24v luminous inverter.... any suggestions would be welcome, attached is a pic of the unit
|
Re: Solar Energy, A Complement To FTA by chris81964(m): 8:08am On Oct 03, 2015 |
earthrealm:I am playing taps. What did the manual say the input voltage should be? In Nigeria they will repair anything. Disconnect it and check all your connections. Reconnect. Sorry for your loss |
Re: Solar Energy, A Complement To FTA by hisenjos: 3:12pm On Oct 03, 2015 |
earthrealm: As suggested, check your connections. Check your pv voltage at your breaker before the charge controller. Most likely a bad panel - Have had similar experience -diode burnt out at panel connector |
Re: Solar Energy, A Complement To FTA by temizeee(m): 6:23pm On Oct 03, 2015 |
earthrealm:remove the + & - pv cable from the cc... retwist it very well n reconnect...afterall, remove all connections from the cc n reconnect them. |
(1) (2) (3) ... (108) (109) (110) (111) (112) (113) (114) ... (1853) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: ksmart027(m) and 2 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 110 |