Re: Solar Energy, A Complement To FTA by chris81964(m): 4:28pm On Jan 08, 2016
How much of my battery is my light bulb using?

https://www.youtube.com/watch?v=JoLR1TN-_rI

1 Like

Re: Solar Energy, A Complement To FTA by Im2Busy2Bother: 4:35pm On Jan 08, 2016
chris81964:


I would buy a second controller and call it a day. Less headache and not much in the thought process department.
Should he decide he needs the headache, the voltage of his existing panels needs to be brought close to the voltage of the newer bigger one. He will lose some of the benefits he got from buying the larger panels after going through all that headache.
My two cents.

Thank you for taking out time in your busy schedule to drop a comment. I'll relay your observation to him.

How do you bring the voltage of existing panels to that of new one?
Re: Solar Energy, A Complement To FTA by chris81964(m): 5:09pm On Jan 08, 2016
Im2Busy2Bother:


Thank you for taking out time in your busy schedule to drop a comment. I'll relay your observation to him.

How do you bring the voltage of existing panels to that of new one?

Series connections
Re: Solar Energy, A Complement To FTA by Im2Busy2Bother: 7:38am On Jan 09, 2016
chris81964:


Series connections

Thank you
Re: Solar Energy, A Complement To FTA by AkoEja: 7:02am On Jan 10, 2016
Can you gurus comment on my setup?
My total load comes to 450 watts . Small fridge and a freezer consuming 200W, LED TV 110W, Light's and fans 140W.

Setup is as follows
Inverter ...1.5KVa
MPPT Charge controller.....40W
Two 200AH Quanta Batteries ....connected in parallel for 24 Volts.
Two 190W solar panels

Assuming I run this load for approximately 7 hours per day.....though will not all run at once. Generally will only run freezer when it's sunny.

Please do you think this is adequate...and if not ..why?
Re: Solar Energy, A Complement To FTA by chris81964(m): 7:42am On Jan 10, 2016
AkoEja:
Can you gurus comment on my setup?
My total load comes to 450 watts . Small fridge and a freezer consuming 200W, LED TV 110W, Light's and fans 140W.

Setup is as follows
Inverter ...1.5KVa
MPPT Charge controller.....40W
Two 200AH Quanta Batteries ....connected in parallel for 24 Volts.
Two 190W solar panels

Assuming I run this load for approximately 7 hours per day.....though will not all run at once. Generally will only run freezer when it's sunny.

Please do you think this is adequate...and if not ..why?
You can do the math yourself
Figure the Watt hours divide by 24 to determine your consumption in AH. That number is how many AH you use. Now determine the minimum depth of discharge for your batteries and increase the ah to compensate.
Then divide the total Watt hours by 4.5 if no NEPA or 6 if you have NEPA. That will answer the question about your Panels.
Re: Solar Energy, A Complement To FTA by semitunde: 11:29am On Jan 10, 2016
kiekie1:
HURRY ! HURRY !! DISCOUNT SALES !!!!!!

TROJAN IND 17-6V industrial line flooded lead acid batteries (1202AH) ......@ 340k

USA TROJAN L16-RE Premium Line Flooded Lead Acid Battery 6V (410AH)20hr Rate *limited quantity*..... @ 75k

USA TROJAN J185P-AC Signature Line Flooded Lead-Acid Battery 12V (205AH) 20hr Rate .... "NOW IN STOCK"....@65k

Solarworld mono panels 255w ,260w,265w "made in Germany" etc now in stock at very discounted prices.........

YACHI SOLAR PANELS:
80w poly............. 13000
130w poly........... 19000
130w mono........ 24000
200w mono........ 35000
250w mono........ 45000
300w mono........ 62000

JOY SOLAR MODULES

POLY SOLAR PANEL:
80W N10000. 100W N13500. 120W N16000. 130W N16500. 160W N23000. 170W N25000. 180W N26000. 250W N30000. 280W N40000.

MONO SOLAR PANEL:
80W N12000. 100W N15000. 110W N15500. 120W N18000. 130W 20000.180W N28000.

Latest model A&E 10kva wall mount servo stab (AC input range 80V-270V)....... @50k

Must power star light inverters with charge current adjustable variable,LCD display,wall mount,remote port,load wattage display,flooded/gel/agm battery settings,battery equalisation and desulphation settings...
1kw 12v =50k
1.5kw 12v =60k
2kw 12v =75k
2kw 24v =75k
3kw"4kva" 24v =120k
4kw 24v/48v =140k
5kw 24v/48v =160k
6kw"7.5kva"24/48v=210k
8kw 192v. =350k
10kw 96v. =380k

Must power inverter boards ...@25k

Programmable timer switch with LCD display 220vac 16a........ @5k

New Epsolar Tracer A series available.30a 12-24v auto select. . Max pv input voltage 100v. It has excellent features like: -inbuilt LCD display,
-high efficiency energy harvest with advanced mppt algorithm
-dual core (ARM CPU+DSP) control architecture
-run data and event recording
-multi phase synchronous rectification tech realizing peak conversion efficiency 98%
-high reliabilty including reverse connection, over current and load short protection etc
-diversified load control mode
-monitor software supplement and firmware update
-extensive communication capabilities (RS232, RS485 with modbus protocol, CAN bus extendable)....@40k


*AUTHORIZED DEALER SOLAR SHOP LTD PRODUCTS*
All our products come with 1 year Warranty

For best affordable prices,contact Smartcell Global Services,Lagos Nigeria. Simply call Sir Frankie "08135031951" for purchase,fast delivery and waybills .. Thanks !!

Can you give me a configuration with cost, of a 5kva inverter supply with solar panel?

The capacity and type if batteries needed, type of inverter recommended, type/size/no of panels and cost for the required solar panels to charge the set up?
Re: Solar Energy, A Complement To FTA by AkoEja: 11:31am On Jan 10, 2016
You can do the math yourself
Figure the Watt hours divide by 24 to determine your consumption in AH. That number is how many AH you use. Now determine the minimum depth of discharge for your batteries and increase the ah to compensate.
Then divide the total Watt hours by 4.5 if no NEPA or 6 if you have NEPA. That will answer the question about your Panels.
Thanksfor your help.
My AH is therefore 450 x7 x 1.6 = 210AH for 40 % depth of discharge.
Divided by 24 gives me 46.6 AH
What is the basis for dividing by 4.5 with no NEPA or 6 with NEPA?
Many thanks again
Re: Solar Energy, A Complement To FTA by semitunde: 11:35am On Jan 10, 2016
.
Re: Solar Energy, A Complement To FTA by semitunde: 11:37am On Jan 10, 2016
chris81964:

You can do the math yourself
Figure the Watt hours divide by 24 to determine your consumption in AH. That number is how many AH you use. Now determine the minimum depth of discharge for your batteries and increase the ah to compensate.
Then divide the total Watt hours by 4.5 if no NEPA or 6 if you have NEPA. That will answer the question about your Panels.

Pls, Can you give a configuration with cost, of a 5kva inverter supply with solar panel?

The capacity and type of batteries needed, type of inverter recommended, type/size/no of panels and cost for the required solar panels to charge the set up?

Thanks.
Re: Solar Energy, A Complement To FTA by abunafiu(m): 1:49pm On Jan 10, 2016
semitunde:


Pls, Can you give a configuration with cost, of a 5kva inverter supply with solar panel?

The capacity and type of batteries needed, type of inverter recommended, type/size/no of panels and cost for the required solar panels to charge the set up?

Thanks.
I suggest you go tru bigrovar's post ahead Where he presented details to assist in recommending solar panels etc.
You need to list ur appliances and the number of hours of use etc.
They way you placed your question might not get answers here.
so kindly rephrase sir.
Re: Solar Energy, A Complement To FTA by chris81964(m): 2:30pm On Jan 10, 2016
semitunde:


Pls, Can you give a configuration with cost, of a 5kva inverter supply with solar panel?

The capacity and type of batteries needed, type of inverter recommended, type/size/no of panels and cost for the required solar panels to charge the set up?

Thanks.
Good day. Please visit our website. http://atlanticwastepower.com/store/
Re: Solar Energy, A Complement To FTA by chris81964(m): 2:38pm On Jan 10, 2016
AkoEja:

Thanksfor your help.
My AH is therefore 450 x7 x 1.6 = 210AH for 40 % depth of discharge.
Divided by 24 gives me 46.6 AH
What is the basis for dividing by 4.5 with no NEPA or 6 with NEPA?
Many thanks again

Bros your numbers are off. How did you get 450?
Take your load eg TV 150 watts.
You will watch TV for 8 hours a day. 150 x 8 = 1200 watt hours.
Do the calculation for all your lights fans and appliances you want to run on solar power. Add up the total
If your total is 1200 watt hours. To determine how much in battery you will be using
1200 / 24 =50 AH. (24 is the voltage of your inverter)
At a 50% SOC that number is 100 AH. You can figure what 40% will be.
To determine the panels 1200 / 4.5 = 267 watts. You will need 267 watts in panels to maintain that TV for 8 hours. (4.5 hrs = sun hours)
We have answered these questions many times before. Go back and read comments and threads explaining what these numbers mean.

2 Likes 1 Share

Re: Solar Energy, A Complement To FTA by bobojoshua(m): 2:57pm On Jan 10, 2016
chris81964:


Bros your numbers are off. How did you get 450 AH?
Take your load eg TV 150 watts.
You will watch TV for 8 hours a day. 150 x 8 = 1200 watt hours.
Do the calculation for all your lights fans and appliances you want to run on solar power. Add up the total
If your total is 1200 watt hours. To determine how much in battery you will be using
1200 / 24 =50 AH. (24 is the voltage of your inverter)
At a 50% SOC that number is 100 AH. You can figure what 40% will be.
To determine the panels 1200 / 4.5 = 267 watts. You will need 267 watts in panels to maintain that TV for 8 hours. (4.5 hrs = sun hours)
We have answered these questions many times before. Go back and read comments and threads explaining what these numbers mean.
Re: Solar Energy, A Complement To FTA by AkoEja: 4:53pm On Jan 10, 2016
Thanks, I think your explanation is very clear enough. The 450 watts is the total of all the watts for my appliances, as follows:
TV ..110, Fridge and freezer ..200W, 2 fans and lights ..140 watts making 450 watts for all . I just assumed I will run all for 7 hours to get a rough calculation. Obviously won't switch all on at the same time.

This means my total watt hour is 3150 watt hours and my total amp hour is 3150/12 = 290AH(12 volts battery-two 12 volts batteries in parallel connection ). My total watts to run for 7 hours is 450 x 7 = 3150 and I will need 3150/4.5 = 700 watts solar panels

But are two 12 volts batteries in parallel rated at 200AH each, equal to 400AH together?

[quote author=bobojoshua post=41844624][/quote]
Re: Solar Energy, A Complement To FTA by semitunde: 11:29pm On Jan 10, 2016
abunafiu:

I suggest you go tru bigrovar's post ahead Where he presented details to assist in recommending solar panels etc.
You need to list ur appliances and the number of hours of use etc.
They way you placed your question might not get answers here.
so kindly rephrase sir.

OK. Thanks.

An electrical ENGR that designed the building recommended 5kva inverter. Since we would want the inverter to be charged by solar power and for the inverter to work for at least 5hrs; I felt the supplier or someone knowledgeable in the solar panels and inverters would be able to advice on the appliances needed and the cost.

But thanks I'll look for the post.

1 Like

Re: Solar Energy, A Complement To FTA by semitunde: 11:41pm On Jan 10, 2016
chris81964:

Good day. Please visit our website. http://atlanticwastepower.com/store/

Thanks. Will check it out. Your explanation here is also enlightening.
Re: Solar Energy, A Complement To FTA by BRIGHTSOLAR(m): 12:45pm On Jan 11, 2016
HAPPY NEW YEAR TO ALL OUR CUSTOMER
Re: Solar Energy, A Complement To FTA by AkoEja: 12:59pm On Jan 11, 2016
Are two 12 volts batteries in parallel rated at 200AH each, equal to 400AH together?
Re: Solar Energy, A Complement To FTA by BRIGHTSOLAR(m): 1:03pm On Jan 11, 2016
LUMINOUS INVERTER

875VA/12V BRAVO 32,000
900VA/12V ECO 34,000
1.5KVA/24V ION 53,000
1.5KVA/24V ECO 53,000
2.5KVA/36V CRUZE 110,000
3.5KVA/48V 140,000
5KVA/72V 240,000
5KVA/96V 230,000
7.5KVA/120V 330,000
10KVA/180V 450,000
15KVA/360V 855,000
20KVA/360V 925,000
30KVA/360V 1,350,000

BATTERY RACK
BATTERY RACK 2 BATTERY 7,500
BATTERY RACK 4 BATTERIES 20,000
BATTERY RACK 8 BATTERIES 30,000
BATTERY RACK 10 BATTERIES 40,000


AUXONA INVERTER

925VA 12V INVERTER 25,000
1500VA 24V INVERTER 35,000
3.5KVA 48V INVERTER 90,000
5KVA 48V INVERTER 180,000
5KVA 96V INVERTER 170,000
3KVA 24V HYBRID INVERTER 200,000
5KVA 48V HYBRID INVERTER 270,000



CHARGE CONTROLLER
20A 12/24V MPPT CONTROLLER 16,000
30A 12/24V MPPT CONTROLLER 18,000
40A 48v MPPT controller (LED) 50,000
30A 96v MPPT controller (LCD) 120,000
60A 48v MPPT controller (LCD) 95,000
60A 60v MPPT controller (LCD) 120,000

MORNINRG STAR TS60 48V/60 90,000


SOLAR PANEL

130w Solar Panel Poly = 16k
200w Solar Panel Poly = 29k

Bright Solar Power ONLINE STORE FOR SOLAR PRODUCTS SOURCING

info@brightsolarpower.com.ng

Call-07058562938

96 Ewusi Street Makun

Sagamu, Ogun State

www.brightsolarpower.com.ng
Re: Solar Energy, A Complement To FTA by BRIGHTSOLAR(m): 1:07pm On Jan 11, 2016
AkoEja:
Are two 12 volts batteries in parallel rated at 200AH each, equal to 400AH together?


yes 12v/400Ah


connecting in Parallel you are doubling the Current capacity of the battery while maintaining the voltage of one of the individual batteries.

Use cable between the positives of both batteries and another cable between the negatives of both batteries. Connect your positive and

negative wires to the same battery to run to your application.
Re: Solar Energy, A Complement To FTA by abunafiu(m): 10:08pm On Jan 11, 2016
BRIGHTSOLAR:
LUMINOUS INVERTER
875VA/12V BRAVO 32,000 900VA/12V ECO 34,000 1.5KVA/24V ION 53,000 1.5KVA/24V ECO 53,000 2.5KVA/36V CRUZE 110,000 3.5KVA/48V 140,000 5KVA/72V 240,000 5KVA/96V 230,000 7.5KVA/120V 330,000 10KVA/180V 450,000 15KVA/360V 855,000 20KVA/360V 925,000 30KVA/360V 1,350,000
BATTERY RACK BATTERY RACK 2 BATTERY 7,500 BATTERY RACK 4 BATTERIES 20,000 BATTERY RACK 8 BATTERIES 30,000 BATTERY RACK 10 BATTERIES 40,000

AUXONA INVERTER
925VA 12V INVERTER 25,000 1500VA 24V INVERTER 35,000 3.5KVA 48V INVERTER 90,000 5KVA 48V INVERTER 180,000 5KVA 96V INVERTER 170,000 3KVA 24V HYBRID INVERTER 200,000 5KVA 48V HYBRID INVERTER 270,000


CHARGE CONTROLLER 20A 12/24V MPPT CONTROLLER 16,000 30A 12/24V MPPT CONTROLLER 18,000 40A 48v MPPT controller (LED) 50,000 30A 96v MPPT controller (LCD) 120,000 60A 48v MPPT controller (LCD) 95,000 60A 60v MPPT controller (LCD) 120,000
MORNINRG STAR TS60 48V/60 90,000

SOLAR PANEL
130w Solar Panel Poly = 16k 200w Solar Panel Poly = 29k
Bright Solar Power ONLINE STORE FOR SOLAR PRODUCTS SOURCING
info@brightsolarpower.com.ng
Call-07058562938
96 Ewusi Street Makun
Sagamu, Ogun State
www.brightsolarpower.com.ng
Kindly share some pictures. ..especially the small mppts u have. tx.
Re: Solar Energy, A Complement To FTA by Nobody: 10:56pm On Jan 11, 2016
BRIGHTSOLAR:
LUMINOUS INVERTER
875VA/12V BRAVO 32,000 900VA/12V ECO 34,000 1.5KVA/24V ION 53,000 1.5KVA/24V ECO 53,000 2.5KVA/36V CRUZE 110,000 3.5KVA/48V 140,000 5KVA/72V 240,000 5KVA/96V 230,000 7.5KVA/120V 330,000 10KVA/180V 450,000 15KVA/360V 855,000 20KVA/360V 925,000 30KVA/360V 1,350,000
BATTERY RACK BATTERY RACK 2 BATTERY 7,500 BATTERY RACK 4 BATTERIES 20,000 BATTERY RACK 8 BATTERIES 30,000 BATTERY RACK 10 BATTERIES 40,000

AUXONA INVERTER
925VA 12V INVERTER 25,000 1500VA 24V INVERTER 35,000 3.5KVA 48V INVERTER 90,000 5KVA 48V INVERTER 180,000 5KVA 96V INVERTER 170,000 3KVA 24V HYBRID INVERTER 200,000 5KVA 48V HYBRID INVERTER 270,000


CHARGE CONTROLLER 20A 12/24V MPPT CONTROLLER 16,000 30A 12/24V MPPT CONTROLLER 18,000 40A 48v MPPT controller (LED) 50,000 30A 96v MPPT controller (LCD) 120,000 60A 48v MPPT controller (LCD) 95,000 60A 60v MPPT controller (LCD) 120,000
MORNINRG STAR TS60 48V/60 90,000

SOLAR PANEL
130w Solar Panel Poly = 16k 200w Solar Panel Poly = 29k
Bright Solar Power ONLINE STORE FOR SOLAR PRODUCTS SOURCING
info@brightsolarpower.com.ng
Call-07058562938
96 Ewusi Street Makun
Sagamu, Ogun State
www.brightsolarpower.com.ng

whats is difference between: 1.5KVA/24V ION 53,000 1.5KVA/24V ECO 53,000 thanks.
Re: Solar Energy, A Complement To FTA by BRIGHTSOLAR(m): 11:46am On Jan 12, 2016
okoegualek:



whats is difference between:
1.5KVA/24V ION 53,000
1.5KVA/24V ECO 53,000
thanks.

thanks same price but difference designs
Re: Solar Energy, A Complement To FTA by bigrovar(m): 5:52am On Jan 13, 2016
grin
AkoEja:
Thanks, I think your explanation is very clear enough. The 450 watts is the total of all the watts for my appliances, as follows:
TV ..110, Fridge and freezer ..200W, 2 fans and lights ..140 watts making 450 watts for all . I just assumed I will run all for 7 hours to get a rough calculation. Obviously won't switch all on at the same time.

This means my total watt hour is 3150 watt hours and my total amp hour is 3150/12 = 290AH(12 volts battery-two 12 volts batteries in parallel connection ). My total watts to run for 7 hours is 450 x 7 = 3150 and I will need 3150/4.5 = 700 watts solar panels

But are two 12 volts batteries in parallel rated at 200AH each, equal to 400AH together?


How did you get the figures for the Fridge and Freezers? They seem very conservative IMHO. Did you get the figures from the equipment label or u used a watt meter? If it was just an estimate then you might want to review them up a bit to like 300 - 350w but it would be best to get a watt meter which would give a more acurate reading. Also it might be wise to get a programmable timer to set when the frige and freezer can come on.. Maybe at around 10-12 noon when everyone should be at work. 2 hours should be sufficient for an efficient freezer to ensure the soup dont go bad. Remember this is worst case (NEPA went awol transformer blew up) scenerio. Also note that both require an starting power of (sometimes ) x 3 of their rated input.

If you TV is LEd what is the size? Unless it is somewhere in the range of 50ish and or was bought 4 hours back.. The 110watt might be a bit high.. Most new led TV's are very efficient.. Most 32 led TV run within the 40-50w range.. Some even go lower.
For the fan ceiling or circulation.. Put 88w each to be safe.. And also ensure you use energy efficient light bulb.. It would help u alot. I got 12 8w Philip energy efficient bulbs from Jumia last year. All my about 11 bulb run for 88w.

Regarding batteries. I would advise you avoid the common SMF deep circle batteries. Unless you want to keep your dod at 50% even that would only guarantee you like 300 circles .. Get a tubular battery which can guarantee close to 1200 circle at 80% dod.

My humble submission

2 Likes

Re: Solar Energy, A Complement To FTA by AkoEja: 7:29am On Jan 13, 2016
bigrovar:
grin

How did you get the figures for the Fridge and Freezers? They seem very conservative IMHO. Did you get the figures from the equipment label or u used a watt meter? If it was just an estimate then you might want to review them up a bit to like 300 - 350w but it would be best to get a watt meter which would give a more acurate reading. Also it might be wise to get a programmable timer to set when the frige and freezer can come on.. Maybe at around 10-12 noon when everyone should be at work. 2 hours should be sufficient for an efficient freezer to ensure the soup dont go bad. Remember this is worst case (NEPA went awol transformer blew up) scenerio. Also note that both require an starting power of (sometimes ) x 3 of their rated input.

If you TV is LEd what is the size? Unless it is somewhere in the range of 50ish and or was bought 4 hours back.. The 110watt might be a bit high.. Most new led TV's are very efficient.. Most 32 led TV run within the 40-50w range.. Some even go lower.
For the fan ceiling or circulation.. Put 88w each to be safe.. And also ensure you use energy efficient light bulb.. It would help u alot. I got 12 8w Philip energy efficient bulbs from Jumia last year. All my about 11 bulb run for 88w.

Regarding batteries. I would advise you avoid the common SMF deep circle batteries. Unless you want to keep your dod at 50% even that would only guarantee you like 300 circles .. Get a tubular battery which can guarantee close to 1200 circle at 80% dod.

My humble submission
Thanks for your comments. .really useful
The freezer is made by Chigo and it says 110 watts on the label and the fridge is a small one..70 watts.
The TV is LG LED (42 LA620V) 42 inches and it says 110 watts on it. The fans are two standing fans 45 watt's each on the label. I am going to replace them with two Lontor rechargeable fans so that the inverter is not used at night....we use the rechargeable fan batteries only (lasts 12 hours at low setting). The Lontor fans say 20 watts at low speed.
All the bulbs are low energy 7-9 watts LED bulbs ( 5 of them with usually just 2 or 3 on at once)
As advised. .will invest in a watt meter. I will also get timers for the fridge and freezer with freezer on for like 3 hours during the day when it's sunny and the fridge also 3 hours...but not at the same time. TV will only be used when we have excess power and fridge and freezer are not on.
Where do I get tubular batteries.. and are they maintenance free? I'll answer this.....tubular batteries are low maintenance and last longer than twice that of ordinary deep cycle batteries. ..4-5 years or longer versus 3 years
Re: Solar Energy, A Complement To FTA by bigrovar(m): 10:37am On Jan 13, 2016
AkoEja:

Thanks for your comments. .really useful
The freezer is made by Chigo and it says 110 watts on the label and the fridge is a small one..70 watts.
The TV is LG LED (42 LA620V) 42 inches and it says 110 watts on it. The fans are two standing fans 45 watt's each on the label. I am going to replace them with two Lontor rechargeable fans so that the inverter is not used at night....we use the rechargeable fan batteries only (lasts 12 hours at low setting). The Lontor fans say 20 watts at low speed.
All the bulbs are low energy 7-9 watts LED bulbs ( 5 of them with usually just 2 or 3 on at once)
As advised. .will invest in a watt meter. I will also get timers for the fridge and freezer with freezer on for like 3 hours during the day when it's sunny and the fridge also 3 hours...but not at the same time. TV will only be used when we have excess power and fridge and freezer are not on.
Where do I get tubular batteries.. and are they maintenance free? I'll answer this.....tubular batteries are low maintenance and last longer than twice that of ordinary deep cycle batteries. ..4-5 years or longer versus 3 years

I think you have it all figured out then. From all indications your estimation for the appliances should be between +-10% actual wattage which is fair. I will look into the Chigo freezer sha.. 110w is quite interesting. You TV would use considerably less watt that you are estimating though.. My guess would be around 60w and low if you select eco mode.. led tv consume way less. But setting a higher figure won't hurt.

I intend to go for Luminous Tubular Batteries.. because it is the only one made using the HADI casting which allows the battery to be more Corrosion resistant, Resistance to High temperatures, Low self-discharge, Resistance to abuse, Lightning fast Recharge.. You can also get USBatteries and Trojan who are also reputable brands but cost a bit higher
Re: Solar Energy, A Complement To FTA by AkoEja: 10:45am On Jan 13, 2016
bigrovar:


I think you have it all figured out then. From all indications your estimation for the appliances should be between +-10% actual wattage which is fair. I will look into the Chigo freezer sha.. 110w is quite interesting. You TV would use considerably less watt that you are estimating though.. My guess would be around 60w and low if you select eco mode.. led tv consume way less. But setting a higher figure won't hurt.

I intend to go for Luminous Tubular Batteries.. because it is the only one made using the HADI casting which allows the battery to be more Corrosion resistant, Resistance to High temperatures, Low self-discharge, Resistance to abuse, Lightning fast Recharge.. You can also get USBatteries and Trojan who are also reputable brands but cost a bit higher

I thought luminous brand is not great in battery tech though they make good inverters
Re: Solar Energy, A Complement To FTA by bigrovar(m): 12:51pm On Jan 13, 2016
AkoEja:

I thought luminous brand is not great in battery tech though they make good inverters

Well from all I have read, Su-kam makes better inverters compared to Luminous, Most of their 12v Inverters in NG market are not Pure sinewave, and Su-kam are the only on with an Automatic Temperature Control module in their low end sub 1.5kva 12v inverters.. which is also capable of 6 stage charging. However when it comes to Batteries Luminous has the upper hand.. At least their Tubular Battery uses HADI technology in casting and most of their SMF batteries are AGM not the sealed wet cell batteries sold by Su-kam as SMF.

It should however be noted that both Su-kam and Luminous are in the low mid range end of the Inverter and batteries business. When compared to the big boys like Trojan, USB, Victron, Outback etc.
Re: Solar Energy, A Complement To FTA by donmajor2: 11:32pm On Jan 13, 2016
donmajor2:
What a great thread! After following this thread for quite some time now, I am glad to begin with a humble entrance into the renewable energy world.

Many thanks to Sir Frankie(Kiekie) shocked for his prompt delivery of Two 12V Trojan batteries and 2KVA Voltron pure sine wave inverter to my doorstep in Benin City.

Special thanks to all the gurus in the house as you make time to respond to virtually all the questions from the newbies like me. I will appreciate your mentoring as I sojourn the solar way.

Plenty regards to Richmon74 for the supply of 4 260W Solarworld mono panels.

I also got solar mounting rails/brackets from c0ogumo of solardepotng.

After collating the main components from the gurus of this great forum, I decided to try my hands on all I have been reading on the sideline.

The result has been impressive. The batteries reach float charge so quickly that I am beginning to think of increasing the number batteries to store the enormous energy pumped out by the 4 Solarworld panels.

This is my very first attempt at solar energy work.

As a newbie, I decided to post some images to open room for corrections.

Many thanks to all members of this thread.

2 Likes

Re: Solar Energy, A Complement To FTA by chris81964(m): 4:02pm On Jan 15, 2016
What does having a 15 amp charger in my inverter mean to me? Watch the video for the answer


https://www.youtube.com/watch?v=jIhLojzzqRk

(1) (2) (3) ... (121) (122) (123) (124) (125) (126) (127) ... (1853) (Reply)

FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 94
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.