Welcome, Guest: Register On Nairaland / LOGIN! / Trending / Recent / New
Stats: 3,208,024 members, 8,001,132 topics. Date: Wednesday, 13 November 2024 at 02:11 AM

Solar Energy, A Complement To FTA - Satellite TV Technology (180) - Nairaland

Nairaland Forum / Entertainment / TV/Movies / Satellite TV Technology / Solar Energy, A Complement To FTA (2383729 Views)

UPS Back-up, Also A Complement To FTA / FTA Frequency / Cctv Installation A Complement To Fta And Solar Energy (2) (3) (4)

(1) (2) (3) ... (177) (178) (179) (180) (181) (182) (183) ... (1854) (Reply) (Go Down)

Re: Solar Energy, A Complement To FTA by bigrovar(m): 8:17am On Oct 16, 2016
DMerciful:
Make sense. To solve the issues you highlighted, we could add an additional well sized breaker on the PV side on top of the double breaker. The double breaker protects the CC-battery circuit and also disconnect the PV side anytime d battery side trips while d low current breaker added for d PV side protects the PV-CC circuit...shikena
completely agree. That is the right setup. Myself should get on with doing that.

2 Likes

Re: Solar Energy, A Complement To FTA by battleaxe: 10:24am On Oct 16, 2016
I'm glad we hmnnnn'd.

Two pages of intelligent conversation that I'm sure will benefit more people in time to come.

Thanks to all the contributors!
Re: Solar Energy, A Complement To FTA by GeorgeD1(m): 10:38am On Oct 16, 2016
DMerciful:
Make sense. To solve the issues you highlighted, we could add an additional well sized breaker on the PV side on top of the double breaker. The double breaker protects the CC-battery circuit and also disconnect the PV side anytime d battery side trips while d low current breaker added for d PV side protects the PV-CC circuit...shikena

dmerciful,
you could avoid all these layers of complexity by just getting the right tool for the job.
a rightly sized midnite solar dc breaker for your pv and cc will give you peace of mind.
kiss (keep it simple and straightforward) should be our focus when it comes to renewables.
the money you save trying to cut corners could come back to haunt you when you
suddenly lose your precious equipment to fires or voltage spikes and you have to replace
them one after the other.

3 Likes

Re: Solar Energy, A Complement To FTA by DMerciful(m): 10:58am On Oct 16, 2016
Oga I hail o. We are looking for low cost solutions. Kindly share this breaker u talked about cheesy
GeorgeD1:


dmerciful,
you could avoid all these layers of complexity by just getting the right tool for the job.
a rightly sized midnite solar dc breaker for your pv and cc will give you peace of mind.
kiss (keep it simple and straightforward) should be our focus when it comes to renewables.
the money you save trying to cut corners could come back to haunt you when you
suddenly lose your precious equipment to fires or voltage spikes and you have to replace
them one after the other.
Re: Solar Energy, A Complement To FTA by Obimind1: 12:52pm On Oct 16, 2016
efuro:


24v system. wired (1-3,2-4). I check voltage read with ordinary digital metre. I have not been able to use Cc to fully charge & go into equalization charge. I presumed one bat is lagging.

by rule I have never gone below 24.4v till day break before I shut down.
equalizing is rattling my brains
I'll advice u separate those batteries, test them individually with ur digital metre to find out which of the battery is lagging. It will help protect other from running down over time.

1 Like

Re: Solar Energy, A Complement To FTA by efuro(m): 1:55pm On Oct 16, 2016
Obimind1:

I'll advice u separate those batteries, test them individually with ur digital metre to find out which of the battery is lagging. It will help protect other from running down over time.

noted with thanks
Re: Solar Energy, A Complement To FTA by Obimind1: 2:54pm On Oct 16, 2016
efuro:


noted with thanks
Congrats on ur newly purchased mppt 60 cc. How has the performance been so far?
Re: Solar Energy, A Complement To FTA by kiekie1(m): 4:15pm On Oct 16, 2016
DISCOUNT .. DISCOUNT ... DISCOUNT !!!!!

Ep solar 12/24/36/48v 150vdc 60a mppt (I TRACER) ..

Re: Solar Energy, A Complement To FTA by efuro(m): 4:40pm On Oct 16, 2016
Obimind1:

Congrats on ur newly purchased mppt 60 cc. How has the performance been so far?

honestly, mppt is superior to pwm.
I get info on my harvest& plenty info I don't really need too.
now I know I can expand pv gradually.
I have not really regreted my actions going AE/RE.
the first day i hit 1kilowatt "i said na me be dis?" even with my ye-ye 4 PVS.
for 2 months even NEPA has refused to bring bills too.
my dear oga obimind, how I wish I had discovered this 2014 or even in 2015

1 Like

Re: Solar Energy, A Complement To FTA by GeorgeD1(m): 7:47pm On Oct 16, 2016
DMerciful:
Oga I hail o. We are looking for low cost solutions. Kindly share this breaker u talked about cheesy

dmerciful,

midnitesolar dc breakers or disconnects are arguably the gold standard in solar pv breakers.
they may be a little expensive but over time you'll get better value for your money.
while there may be other cheaper alternatives which go by different names, its always better
to stick with tested brands which have proven themselves with time.
in renewables, we should be careful not to sacrifice quality on the alter of low cost
alternatives which do disappoint when needed most.

http://www.midnitesolar.com/productPhoto.php?product_ID=183&productCatName=BREAKERS&productCat_ID=16&sortOrder=16

Re: Solar Energy, A Complement To FTA by Obimind1: 10:11pm On Oct 16, 2016
efuro:


honestly, mppt is superior to pwm.
I get info on my harvest& plenty info I don't really need too.
now I know I can expand pv gradually.
I have not really regreted my actions going AE/RE.
the first day i hit 1kilowatt "i said na me be dis?" even with my ye-ye 4 PVS.
for 2 months even NEPA has refused to bring bills too.
my dear oga obimind, how I which I had discovered this 2014 or even in 2015
My Broda, I envy you. Mppt has always been on my mind, but its just that I have some other projects on ground that is eating up my money. Pls can u send me a chat via my email address so we can talk more privately? obinnaokechukwu7@gmail.com.
Re: Solar Energy, A Complement To FTA by DMerciful(m): 10:38pm On Oct 16, 2016
Super thanks....noted
GeorgeD1:


dmerciful,

midnite solar dc breakers or disconnects are arguably the gold standard in solar pv breakers.
they may be a little expensive but over time you'll get better value for your money.
while there may be other cheaper alternatives which go by different names, its always better
to stick with tested brands which have proven themselves with time.
in renewables, we should be careful not to sacrifice quality on the alter of low cost
alternatives which do disappoint when needed most.

http://www.midnitesolar.com/productPhoto.php?product_ID=183&productCatName=BREAKERS&productCat_ID=16&sortOrder=16
Re: Solar Energy, A Complement To FTA by tundebabzy: 11:22pm On Oct 16, 2016
Hello all,
I need advice from the house.

I (regret that) I purchased a 12v tripplite inverter in 2014. I now want to go head on into solar.

I wish to power a load of 1.784kwh targeting 50% DOD for my batteries with 1 day autonomy. From my calculations, I'll need battery capacity of 297ah. I also calculated under ideal conditions, I'll need a cc of minimum of 59.5a and modules of 713.6w to juice up the batteries.

Estimated consumption: 1784wh
@50% DOD: 297.3ah (2 200ah batteries)
Hours of sunlight: 5
Min Charge controller size: 59.4a
Solar modules: 713.6w

In the future I plan to get a bigger inverter and more modules. By the time I get a bigger higher voltage inverter, will it be better to leave my present installation and let the new inverter power the remaining load? Considering that this is a small installation and how expensive MPPT cc is, should I go for an PWM CC instead of MPPT? I want an option that is scalable and cost effective.

I look forward to your candid advice. Help a brother not to make a costly mistake.
Re: Solar Energy, A Complement To FTA by dicksonadams(m): 11:37pm On Oct 16, 2016
tundebabzy:
Hello all,
I need advice from the house.

I (regret that) I purchased a 12v tripplite inverter in 2014. I now want to go head on into solar.

I wish to power a load of 1.784kwh targeting 50% DOD for my batteries with 1 day autonomy. From my calculations, I'll need battery capacity of 297ah. I also calculated under ideal conditions, I'll need a cc of minimum of 59.5a and modules of 713.6w to juice up the batteries.

Estimated consumption: 1784wh
@50% DOD: 297.3ah (2 200ah batteries)
Hours of sunlight: 5
Min Charge controller size: 59.4a
Solar modules: 713.6w

In the future I plan to get a bigger inverter and more modules. By the time I get a bigger higher voltage inverter, will it be better to leave my present installation and let the new inverter power the remaining load? Considering that this is a small installation and how expensive MPPT cc is, should I go for an PWM CC instead of MPPT? I want an option that is scalable and cost effective.

I look forward to your candid advice. Help a brother not to make a costly mistake.


Brotherly I recommend Dmerciful for you. He is a generous scholar

1 Like

Re: Solar Energy, A Complement To FTA by c0ogumo(m): 2:29am On Oct 17, 2016
=========SOLAR DEPOT NIGERIA==========

New Arrival: American Samlex Evolution Series Inverter/Charger

EVO2024E with 70A Charger
EVO4024E with 110A Charger
http://solardepotng.com/SDN/wp-content/uploads/2016/01/EVO-E-series-230-VAC.pdf

N100K cheaper than MAGNUM

Email: info@solardepotng.com Mobile: 0812 626 1756

www.solardepotng.com

1 Like

Re: Solar Energy, A Complement To FTA by DMerciful(m): 6:20am On Oct 17, 2016
When it comes to solar, u want to avoid wastage as much as possible so considering PWM that will waste 20%-30% of available power is a no-no. Go for mppt of 40A-60A especially considering you planned to expand. Use 10mm cables to run the PV line so when you expand the cables will suffice. I advice u sell your 12V inverter and get at least a 24V, >=2.5kva inverter and if cost is a challenge go for the Indian brands like mopower, sulkam, nexus, luminous , the solar will definitely cover for all charging inadequacies. Also install a desulphator, its cheap. You need to spend appreciable amount when going green in order not to get frustrated with the outcome. What's ur budget and I can point u in d right direction....Whatsapp me on 08035415969
tundebabzy:
Hello all,
I need advice from the house.

I (regret that) I purchased a 12v tripplite inverter in 2014. I now want to go head on into solar.

I wish to power a load of 1.784kwh targeting 50% DOD for my batteries with 1 day autonomy. From my calculations, I'll need battery capacity of 297ah. I also calculated under ideal conditions, I'll need a cc of minimum of 59.5a and modules of 713.6w to juice up the batteries.

Estimated consumption: 1784wh
@50% DOD: 297.3ah (2 200ah batteries)
Hours of sunlight: 5
Min Charge controller size: 59.4a
Solar modules: 713.6w

In the future I plan to get a bigger inverter and more modules. By the time I get a bigger higher voltage inverter, will it be better to leave my present installation and let the new inverter power the remaining load? Considering that this is a small installation and how expensive MPPT cc is, should I go for an PWM CC instead of MPPT? I want an option that is scalable and cost effective.

I look forward to your candid advice. Help a brother not to make a costly mistake.

2 Likes

Re: Solar Energy, A Complement To FTA by coolchifx(m): 7:18am On Oct 18, 2016
You can make as much as N40k on your 200Ah used, bad/condemned inverter batteries. call or what app -08125203137 0r 08038105574(T&C apply)

Other Prices (Inverter Batteries)
150Ah - N25,000
100Ah - N18,000

For 2v (ATM) Batteries
1500Ah - N65,000
1000Ah - N40,000
500Ah - N18,000

For Car/ Trailer Batteries:
200 Ah - N28,000
100 Ah - N12000
75Ah - N8000
65Ah - N7500
45Ah - N5000

For Ups Batteries:

17Ah- N1500
12Ah - N1000
9Ah - N700

1 Like 1 Share

Re: Solar Energy, A Complement To FTA by skydancer: 3:55pm On Oct 19, 2016
c0ogumo:
=========SOLAR DEPOT NIGERIA==========

New Arrival: American Samlex Evolution Series Inverter/Charger

EVO2024E with 70A Charger
EVO4024E with 110A Charger
http://solardepotng.com/SDN/wp-content/uploads/2016/01/EVO-E-series-230-VAC.pdf

N100K cheaper than MAGNUM

Email: info@solardepotng.com Mobile: 0812 626 1756

www.solardepotng.com

Hello, I just called now and no response. Will like to know how to get a 10 or 15kva samlex inverter or any other recommended inverter with over 0.9 efficiency.
Re: Solar Energy, A Complement To FTA by idsolar(m): 4:13pm On Oct 19, 2016
1. SUKAM 1.4KVA FOR SALE:
1.4kva sukam. 1yr 5month used. for sale due to upgrade. S O L D S O L D S O L D


2. solar charge controller (new). 12/24v 30amp.
call 08033735359 now
Re: Solar Energy, A Complement To FTA by mank1234(m): 9:05pm On Oct 19, 2016
@ kiekie1: how much do you sell programmable timer socket and DIN programmable timer switch pictured below.

Re: Solar Energy, A Complement To FTA by kiekie1(m): 9:45pm On Oct 19, 2016
mank1234:
@ kiekie1: how much do you sell programmable timer socket and DIN programmable timer switch pictured below.

My mobile number is visible* See signature ... Thanks !
Re: Solar Energy, A Complement To FTA by bomeri(m): 9:12am On Oct 20, 2016
coolchifx:
You can make as much as 13k-15k on your 200Ah bad/condemned inverter batteries. call or what app -08125203137 0r 08038105574(T&C apply)

Other Prices (Inverter Batteries)
150Ah - N10,500
100Ah - N6,500
75Ah - N4,000
65Ah - N3000

For 2v Batteries
1500Ah - N25,000
1000Ah - N16,500
500Ah - N7,500

For Car/ Trailer Batteries:
200 Ah - N8,000
100 Ah - N4,000
75Ah - N2,000
65Ah - N1500
45Ah - N1000

For Ups Batteries:

17Ah- N700
12Ah - N400
9Ah - N300

Location and the bolded is that the price u sell? Or buy??
Re: Solar Energy, A Complement To FTA by kiekie1(m): 10:11am On Oct 20, 2016
Brand new Sukam battery 12v 200a at an affordable price .. Call now !!
Re: Solar Energy, A Complement To FTA by totalgreen01: 10:20am On Oct 20, 2016
My oga, i don show o,

your recommendation is on point "we should be careful not to sacrifice quality on the alter of low cost
alternatives which do disappoint when needed most"

hi guys long time...


GeorgeD1:


dmerciful,

midnitesolar dc breakers or disconnects are arguably the gold standard in solar pv breakers.
they may be a little expensive but over time you'll get better value for your money.
while there may be other cheaper alternatives which go by different names, its always better
to stick with tested brands which have proven themselves with time.
in renewables, we should be careful not to sacrifice quality on the alter of low cost
alternatives which do disappoint when needed most.

http://www.midnitesolar.com/productPhoto.php?product_ID=183&productCatName=BREAKERS&productCat_ID=16&sortOrder=16

1 Like

Re: Solar Energy, A Complement To FTA by totalgreen01: 10:30am On Oct 20, 2016
http:///digital-lcd-7-day-programmable-timer-switch-ac220v-20a-2824905

mank1234:
@ kiekie1: how much do you sell programmable timer socket and DIN programmable timer switch pictured below.

1 Like

Re: Solar Energy, A Complement To FTA by tundebabzy: 2:36pm On Oct 20, 2016

1 Like

Re: Solar Energy, A Complement To FTA by durodee(m): 6:40pm On Oct 20, 2016
Guys, anybody with a 24v battery life saver ? Interested in making a purchase ASAP. Thanks.
Re: Solar Energy, A Complement To FTA by Gennextech: 10:11am On Oct 21, 2016
Good Morning , Gennex will be having a free workshop for professional and intermediary installers where we would share ideas and discuss business and technical challenges in the solar energy in early November, all our esteemed professionals and clients are very much invited, please do confirm your interest by replying this post, products will also be sold at discounts at the workshop. Thank you

Re: Solar Energy, A Complement To FTA by Dreamflyin(m): 12:36pm On Oct 21, 2016
Please, iwant to change my two 50amps PWM to mppts.
Each PWM is connected to a 1kw panel PV.
What amps should be better?
Also, how long will the four battery bank last?
The installer said PWMs don't stress batteries like Mppts.
Re: Solar Energy, A Complement To FTA by efuro(m): 5:52pm On Oct 21, 2016
Dreamflyin:

The installer said PWMs don't stress batteries like Mppts.
embarassed
Dreamflyin:

The installer said PWMs don't stress batteries like Mppts.

another brain session coming up

personally I will allow mppt manage my batteries, lucky you! you have large array pumping juice to ur bat.

anyway the baby in the house has spoken. let my gurus attend to your fears.

good luck
Re: Solar Energy, A Complement To FTA by earthrealm(m): 6:28pm On Oct 21, 2016
Dreamflyin:
Please, iwant to change my two 50amps PWM to mppts.
Each PWM is connected to a 1kw panel PV.
What amps should be better?
Also, how long will the four battery bank last?
The installer said PWMs don't stress batteries like Mppts.

that installer should be shot at sunset, and shot again @ sunrise if he is still alive
utter rubbish,
go for mppt, is your setup 24v or 48v?, if 48v 60amp mppt wud b good, if 24, you need 80amps mppt

batteries last per load connected to it, convert the juice in ur battery to watts, and divide by the wattage of ur load, multiply by 80% to factor in losses/efficiency, or first multiply the baat wattage by 50% to get 50% dod

@ all, the attached picture, who knows where i can buy it, and the nigerian name for it?

4 Likes

(1) (2) (3) ... (177) (178) (179) (180) (181) (182) (183) ... (1854) (Reply)

FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread

Viewing this topic: bassdow, Allem(m) and 1 guest(s)

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 59
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.