Re: Solar Energy, A Complement To FTA by DMerciful(m): 11:59pm On Jun 10, 2017 |
Thanks...will check it out pranil: |
Re: Solar Energy, A Complement To FTA by davodyguy: 12:14am On Jun 11, 2017 |
Dam5reey:Does the highlighted mean battery connection should be in series rather than in panel as currently is? |
Re: Solar Energy, A Complement To FTA by Dam5reey(m): 5:21am On Jun 11, 2017 |
davodyguy: Yes, this will make your battery system 24 Voltage.. and capacity 200Ah.. Rather than your 12V 400Ah. however, you will need to change the Inverter to 24V.. Since your Panel is 800Watts.. you can use a 24V 40A MPPT controller, which will take 1040Watts panel at 24V |
Re: Solar Energy, A Complement To FTA by davodyguy: 8:38am On Jun 11, 2017 |
Dam5reey: Good morning For now, I do not intend to change inverter How best should I go about my 1000 watts 12 v 400amps battery 800 watts solar panel Mppt 40amps charger |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 9:03am On Jun 11, 2017 |
davodyguy: Jst check if ur mppt has a nominal voltage of 12v, if ur panel is 24v,u can connect ur panel in parallel or even series two 24v as long as it doesn't exceed the max input voltage of the cc(usually btw 100v to 150v).the Mppt ll tk care of the rest. Also check ur nameplate to mk sure u r nt exceeding the current ur controller can dish out |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 9:12am On Jun 11, 2017 |
zeestone99:Price update Solar panels Flames 300w mono - 69k 250w mono - 59k 250w poly- 54k Sunshine solar 300watts mono=67k 250watts mono=58k 250watts poly=53k Keep ur orders coming, fast delivery, proffesional installation guaranteed. even our oga George can testify to our proffesional service. 3 Likes
|
Re: Solar Energy, A Complement To FTA by Saipro(m): 9:22am On Jun 11, 2017 |
DMerciful: I'm afraid DMerciful is quite right. Oshomo12: You would have noticed a similar difference even with professional roof mounts. Mine have absolutely nothing underneath them and I had the same experience as you had. What you did was bring the temperature down closer to the lab temperature of 25oC. I had posted a year or two ago the impact a brief rain has on them, in addition to the bright "flare" immediately after a midday shower. The margin will also reduce as your panels age and their efficiency drops. Believe me however when I tell you, you can have 80% losses from poor angling. In an experiment I conducted under non-standard conditions (but otherwise reproducible), the difference between placing them flat and angling them 30o due South is about 30%. Give it a try on a clear and sunny day, around midday. Mine are angled at 8o due South (they accumulate dust faster and pool water when placed flat). |
Re: Solar Energy, A Complement To FTA by Saipro(m): 9:27am On Jun 11, 2017 |
Dam5reey: PWM doesn't really do energy conversion. That's why losses might be great if there's a panel voltage:battery bank mismatch. And if they match too closely (to ensure max efficiency), you'd get pitiful charge on cloudy days - unless your bank is quite depleted (not good). Also, as others have mentioned, unless you have your panels and PWM controller sitting directly above your battery bank, your losses might be significant. And it's a waste of good copper buying cables as thick as your wrist, even if you could afford them. 2 Likes |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 12:22pm On Jun 11, 2017 |
durodee: Its been a while tho .. DM me via whats app . Thanks |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 12:23pm On Jun 11, 2017 |
Ferdiwar: Yes I agree with you bro |
Re: Solar Energy, A Complement To FTA by JUO(m): 12:53pm On Jun 11, 2017 |
JUO:Available for 5 days Fangpusun 80a-12/24/36/48/60v=165k 70a-12/24/36/48v=100k 60a-12/24/36/48/60v=145k 60Da-12/24/36/48v=115k 50Da-12/24v=60k 50a-12/24v=45k 45a-12/24/36/48v=70k 30a-12/24v=30k Mppt control=18k Epsolar 40a A series -12/24v=59k 30a A series -12/24v=45k 30a CN series -12/24v=33k Mt50=15k Battery monitor Dc-100a-6-100v=9k AC-100a-220v=6k DC breaker 125v-16-63a=3k Digital timer din rail 220v/16a=5k O8o98733709 3 Likes |
Re: Solar Energy, A Complement To FTA by efuro(m): 3:46pm On Jun 11, 2017 |
JUO:thank you ! will spread the message 1 Like |
Re: Solar Energy, A Complement To FTA by dapsyra(m): 3:59pm On Jun 11, 2017 |
There must have been a huge power surge in my area overnight. I woke up this morning to discover my Midnite Solar Surge Protection Device MNSPD300 completely damaged. Thanks to the MNSPD300, none of my gears was damaged. The device was installed on the PHCN grid supply to the house 18months ago. You are all invited to the survival party. 5 Likes
|
Re: Solar Energy, A Complement To FTA by davodyguy: 4:32pm On Jun 11, 2017 |
zeestone99: I'm just about to do the connection. I just got panels, but was confused about the capacity of the charged controller to buy. We are fixing next Saturday, that's why I need advise |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 5:35pm On Jun 11, 2017 |
davodyguy: What typ of panels, 200w or 250watt, buy a mppt 12v/24v controller, epever or any gud brand ll do, if u need controller watapp 08117398294 |
Re: Solar Energy, A Complement To FTA by DMerciful(m): 7:26pm On Jun 11, 2017 |
I use stabilizer for incoming Phcn. Any over voltage is taken care of by the stab while displaying unusual with no output until d voltage is normalised that way I don't loose anything. I think that's a more cost effective option dapsyra: 3 Likes |
Re: Solar Energy, A Complement To FTA by mank1234(m): 8:45pm On Jun 11, 2017 |
You need both surge arrester and voltage regulator. They are for different purposes. Transfer time of relays in stabilizer is in milliseconds whereas lightening induced overvoltage occurs in microseconds. You're protected against overvoltage but not transient current when you use stabilizer. His surge arrester got fried from prolong exposure to overvoltage which a stabilizer could have prevented. On the other hand, a stabilizer may be fried from a single lightening transient unlike a surge arrested which will only deteriorate. DMerciful: 3 Likes |
Re: Solar Energy, A Complement To FTA by davodyguy: 9:18pm On Jun 11, 2017 |
zeestone99: 200 watts panels x 4 made by frames How many amps charge controller would work for a parallel connection for the 4 panels to charge 2 now 12 v 200amps batteries? |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 11:30pm On Jun 11, 2017 |
davodyguy: My advice - buy a 1.5/2kva 24v inverter, one 40amps Mppt charge controller, sell ur 1kva/12v inverter. Connect ur panels 2×2 config. #cheers N:B you can get gud used inverter at affordable prices from pple that upgraded their system 1 Like |
Re: Solar Energy, A Complement To FTA by chris81964(m): 3:08am On Jun 12, 2017 |
Dam5reey:He has a 12 V inverter. Why should he change the inverter? |
Re: Solar Energy, A Complement To FTA by chris81964(m): 3:12am On Jun 12, 2017 |
davodyguy: If you have a good quality inverter keep it. You have 800 Watts in panels. Divide by your inverter voltage. That will give you the size of controller you need. 2 Likes |
Re: Solar Energy, A Complement To FTA by chris81964(m): 3:16am On Jun 12, 2017 |
davodyguy:If you can afford it a good quality MPPT. If your application does not require deep discharge of your batteries then a pwm will do the job. More tricky to work with but they do the job. |
Re: Solar Energy, A Complement To FTA by chris81964(m): 3:18am On Jun 12, 2017 |
kiekie1:I own a small version of it and so far so good. It is on 24/7. 1 Like |
Re: Solar Energy, A Complement To FTA by Saipro(m): 7:09am On Jun 12, 2017 |
dapsyra: The thing is all burnt up! Looks like a sustained surge (if such a thing exists/grid overvoltage). Or a direct hit by lightning on a line very close to you. You're one lucky man indeed! Party time!!! mank1234: You're right. AVRs won't protect against surges and brownouts. A fuse has a better chance (if the surge current is high enough; rarely ever so). In addition, there are instances the surge is so powerful, it freezes the AVR in "on" mode thus transmitting the entire surge/over-voltage through. I have an 2kVA AVR which is no more than than a mere 10V booster as a result of that. |
Re: Solar Energy, A Complement To FTA by Saipro(m): 7:12am On Jun 12, 2017 |
chris81964: I need to get me one of those! Kindly recommend a reliable (trusted by you) contact on these pages. I'm sure many others on this forum are already drooling at the prospect of an energy efficient + reliable freezer 1 Like |
Re: Solar Energy, A Complement To FTA by Dam5reey(m): 8:39am On Jun 12, 2017 |
chris81964: I did the analysis already... On previous posts. He need 60A charge controller which would cost more that 40A MPPT.. it's better to have 24V 200Ah Bank than 12V 400AH.. |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 8:43am On Jun 12, 2017 |
Saipro: just a heads up, there are basically 2 types of refrirant the older r600a - toxic, outdated, gradually being phased out for domestic applications in most western countries, chills faster/more efficient and r134a - newer, genrally accepted, doesnt chill as much as the toxic r600a thats why older cars chilled better and faster than the new cars, even fridges and freezers, cos they used r600a back then, which is toxic/harmful and require careful handling, causes ozone layer depletion etc. govts had to step in to effect the change to the less efficient but safe r134a, thus r660a gas and components are a bit scarce and thus also more expensive |
Re: Solar Energy, A Complement To FTA by Dam5reey(m): 8:55am On Jun 12, 2017 |
davodyguy: It's possible.. with Epsolar MPPT controller... 40A.. however you will still loose power during peak periods.. Connect in 2 x 2 strings... Option 2 buy 60A, 70A MPPT controller as I stated earlier.. 800Watts will generate Approx 60A at 13.8 float charge... 1 Like |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 11:48am On Jun 12, 2017 |
Dam5reey: Yes , he can simply contact me for complete kit of pro solar roof mount (rails & accessories) .. Cheers
|
Re: Solar Energy, A Complement To FTA by chris81964(m): 12:14pm On Jun 12, 2017 |
Saipro: Purchased it on Konga |
Re: Solar Energy, A Complement To FTA by chris81964(m): 12:17pm On Jun 12, 2017 |
Dam5reey: So the difference in cost between a 40 A and 60 A is more than the cost of replacing his inverter. Let me make sure I understand you. He already has an inverter. You want him to forget his inverter and buy a 24 V inverter to justify buying a 60 Amp controller. Is this what you are asking him or her to do? |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 12:52pm On Jun 12, 2017 |
kiekie1: just compared with haier/lg/samsung. beko rules them all, the kwh /year consumption is far lower than any of the makes. Energy consumption (kWh / year) 308 --- beko 379ltr Energy Consumption (KWhr/yr) 693.0 haier thermocool 379ltr @kiekie, i dey vex for you o, why did you release this info weeks ago, when i told the house i was in the market for an energy efficient freezer! this beko consumes less 50% what the haierthermoccol does 1 Like |
(1) (2) (3) ... (258) (259) (260) (261) (262) (263) (264) ... (1822) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: kristien4(m) and 3 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 4 |