Re: Solar Energy, A Complement To FTA by Refa: 5:37am On Jun 29, 2017 |
I am sure the digital displays alone will not suffice to help give you a good explanation. Not knowing your Inverter capacity, type of inverter, whether it has it always been like this or this is a recent occurrence? So many factors can be contributing to this issue; size of cables, fans going bad, location of inverter, even the monitoring devices could be contributing. I am just covering all basis I can think of in this situation, since I don't know anything about the setup. I have attached an efficiency curve for Xantrex XW4548/6048/4024 just to bring clarity to some of the concerns I have raised. These inverters are all rated above 92%+ efficient, albeit, you notice that when the load is less than 300W, the efficiency suffers drastically; If a big inverter (3000W+) is used for a small load (300W), the efficiency of inverter is not going to 92% These inverters are from the same manufacturer (Yes Xantrex, now owned by Schneider), the efficiencies vary differently with respect to varying load. The XW4024 commences an efficiency degradation after 1000W, while the others are still doing very well. [b][/b]ALL INVERTERS ARE NOT MADE EQUAL. Location of an inverter is also key; All inverters use switching devices and AC inductors of some sort. These devices generate a fair amount of heat hence the need for the cooling fans. An inverter located in a functioning kitchen is not going to out perform one that is located in a place with lots of cool breeze. Likewise an inverter that is located in area granting access to the fans to draw in a lot of dust, so that the electrical components are coated with thick layers of dust inhibiting proper cooling.An inverter like this is not going to out perform one that is carefully placed. Big names SMA, Xantrex, Outback etc use filters at the vents for the fans to filter out air. Cable sizing; For simplification, lets do some basic math; Resistance R to the flow of Electricity is proportional to the Length L of the wire and inversely proportional to the Cross-sectional Area A R = K (L)/(A), K is resistivity- material dependent. In order to keep resistance low, an appropriate diameter must be chosen to correspond to the length and current that is flowing through the wire. Else part of the power consumed is lost to heat in the wire. This could also potentially damage the wire-for this reason fuses and breakers are sized based on the connected wires (See attached sheet). Power loss to heat; P=I[sup][/sup]2R Monitoring devices; Not all measuring devices do the job with the same degree of accuracy. For solar applications, this may not be an issue at all; the monitoring devices we use may not be accurate by standards in some industries, but they give us the requisite information with a degree of accuracy, satisfactory enough to tell us we are in trouble or not. But, when two different devices (from different manufacturers) are being used to take measurements, the difference in measuring and calibration methods may contribute a little bit for us to be alarmed. You may want to use the same device in taking all your measurements. Some of the points above are insignificant, but I thought it is worth mentioning if all contributing factors are to be considered. efuro: 3 Likes
|
Re: Solar Energy, A Complement To FTA by tivta(m): 9:04am On Jun 29, 2017 |
Refa: Nice explanation BUT not all inverters use fan for cooling, there buy reducing extra load. |
Re: Solar Energy, A Complement To FTA by BRIGHTSOLAR(m): 10:25am On Jun 29, 2017 |
LUMINOUS INVERTER 1.5KVA/24V ECO 73,000 3.5KVA/48V 180,000 5KVA/96V 350,000 MICROTECH INVERTER 1.1KVA,12V 50,000 1.6KVA/24V 75,000 3.5KVA/48V 170,000 MUST POWER STAR INVERTER 1KVA 1000W 12v 95,000 4kva 3000W 24V 250,000 5kva 4000W 48V 300,000 6kva 5000W 48V 350,000 7.5kva 6000W 48V 450,000 BATTERY GLT BATTERY 12V/100AH 55,000 GLT BATTERY 12V/150AH 73,000 GLT BATTERY 12V/200AH 100,000 ZEEDIX BATTERY 12V/100AH 45,000 ZEEDIX BATTERY 12V/150AH 70,000 ZEEDIX BATTERY 12V/200AH 90,000 BATTERY RACK BATTERY RACK 2 BATTERY 15,000 BATTERY RACK 4 BATTERIES 30,000 BATTERY RACK 8 BATTERIES 50,000 CHARGE CONTROLLER ROY SOLAR SERIES 20A 12/24V PWM CONTROLLER 20,000 30A 12/24V PWM CONTROLLER 25,000 40A 48v PWM controller (LED) 50,000 30A 96v PWM controller (LCD) 120,000 60A 48v PWM controller (LCD) 95,000 SOLAR PANEL 150w M-40,000 200w M-45,000 260w M-60,000 310w M-75,000 Bright Solar Power ONLINE STORE FOR SOLAR PRODUCTS SOURCING Call-07058562938 |
Re: Solar Energy, A Complement To FTA by trewbless(m): 11:06am On Jun 29, 2017 |
trewbless:My brother let me ask u a question again, if for instance am having a 2400watts in my battery that take a whole 10hrs to charge at 100%, and I have a gadget that consumed 250watts ,which means I cannot be having 24/7 light knowing fully well solar cannot charge my battery 24hrs. Pls explain this to me thanks. |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 11:58am On Jun 29, 2017 |
surrogatesng: yup, such freezers exist, chk lg/thermoccol and scanfrost . wud recommend a 1kva inverter. search for beko freezers on jumia/konga if u want super efficient one..maybe as low as 30/40watts for that size 1 Like |
Re: Solar Energy, A Complement To FTA by efuro(m): 2:38pm On Jun 29, 2017 |
Obascoetubi: bigbrovar: Saipro: Thanks All It has been bad trying to post here in the last few days particularly if you don't copy remarks before posting them. the inverter is Microtek 1,600w (2KVa). In addition to your views above. do you think DC Amps drawn by the inverter is same as AC Amps irrespective of the waste due to conversion? I know DC watts is not = to AC watts
|
Re: Solar Energy, A Complement To FTA by earthrealm(m): 2:52pm On Jun 29, 2017 |
nope dc amps is not equal to ac amps.. for example a 220v ac freezer that consumes 1amp will draw about 24amps from a 12v batt system, 11amps from a 24v batt system etc |
Re: Solar Energy, A Complement To FTA by Refa: 3:02pm On Jun 29, 2017 |
Thanks Tivta, you are right, some off gird inverters do not use fans. These are either very small inverters which do not incorporate a charger or are going to be prohibitively expensive. Also most micro inverters and DC optimizers (these are grid tied, not very useful in a blackout scenario) do not use fans. Our load requirements and climatic conditions will necessitate the use of fanned inverters tivta: |
Re: Solar Energy, A Complement To FTA by efuro(m): 4:36pm On Jun 29, 2017 |
@ Refa Thank you so much for a detailed insight to inverters and their working conditions, well I will keep studying the inverter and keep the house informed for the benefit of some with similar inverters Thanks again |
Re: Solar Energy, A Complement To FTA by bigrovar(m): 8:21pm On Jun 29, 2017 |
efuro: Watt is watt irrespective of whether dc or AC. The fundamentals of power doesn't change. Amps x volt will always be equal to watts just that with AC you have higher voltage than amps. While reverse is with DC. Inverters just convert from DC to AC but in doing so some energy is lost to heat.. This is what is called inverter efficiency. The higher the efficiency the lower the loss. Efficiency of inverters is usually represented by percentage in must inverters. Mine is 85% efficient meaning only 85% of DC power taking from battery is converted to AC %15 is lost to heat (when it running at full capacity) . If u have a watt meter. You can determine how much the inverter uses to run which is called idle load. I found mine uses 50w just when running without any loaf attached. From what you have posted it seems your inverter itself is using close to 100w just to run. This might explain the missing watts you noted. 8 Likes |
Re: Solar Energy, A Complement To FTA by mcTrinity(m): 11:39pm On Jun 29, 2017 |
Refa: thanks for your explanation... my major concern was whether the two can be paralleled together: got 4 batteries (200Ah @20hr) I installed for a client (for 48v system). 2weeks later, I got another 4 batteries of same brand but 200Ah @10hr. But I've paralleled the two banks. hopefully, there won't be discrepancy due to different hour rating |
Re: Solar Energy, A Complement To FTA by mcTrinity(m): 11:53pm On Jun 29, 2017 |
efuro: if you have 500w load on a 24v inverter system, it will draw 2.2A from the AC side P=I/V I=P/V = 500/230 = 2.17A but from the DC side, it will draw 21A 500/24 = 20.8A Energy can neither be created nor destroyed but can be changed from one form to another. power on AC side is equal to power on DC side (assuming perfect system without loses). The only parameters that varies are current and voltage 4 Likes 1 Share |
Re: Solar Energy, A Complement To FTA by efuro(m): 6:53am On Jun 30, 2017 |
mcTrinity: am guided by ur principle above. very straight forward. it is appreciated. |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 10:35am On Jun 30, 2017 |
surrogatesng: You can get this standalone 100litres solar DC freezer from us. All u need is to get a battery, panel n cc u r gud 2 go, call/whatapp 08117398294 for more info, you can as well mail us on Info@monzpowersolutions.com
|
Re: Solar Energy, A Complement To FTA by surrogatesng: 9:53pm On Jun 30, 2017 |
zeestone99:I called and you said its not in stock now |
Re: Solar Energy, A Complement To FTA by tomi01(m): 11:56pm On Jun 30, 2017 |
Hello all, I'm in need of fairly used 200ah battery urgently .. location - Ile Ife Osun State. 1 Like |
Re: Solar Energy, A Complement To FTA by dicksonadams(m): 4:41am On Jul 01, 2017 |
tomi01: Think it is better you close eye and buy a new battery, fairly use is no good in the short run. My advice based on experience, No seller will ever tell you the true condition 2 Likes |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 5:19am On Jul 01, 2017 |
surrogatesng: No longer in stock, 200 litres available limited quantity. Order urs nw |
Re: Solar Energy, A Complement To FTA by Juokorow(m): 6:17am On Jul 01, 2017 |
kiekie1: Thanks. Immensely helpful! 1 Like |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 12:35pm On Jul 01, 2017 |
tomi01: Hello , i should have 1 remaining in stock for now .. Simply call 081-350-319-51 . Cheers! |
Re: Solar Energy, A Complement To FTA by Saipro(m): 2:33pm On Jul 01, 2017 |
chris81964: Still waiting to see if you're selling else I'll have to sell mine. |
Re: Solar Energy, A Complement To FTA by chris81964(m): 4:10pm On Jul 01, 2017 |
Saipro:Lets talk |
Re: Solar Energy, A Complement To FTA by bodeface: 7:34am On Jul 02, 2017 |
Hello SMEs Happy Sunday to everyone. I am planning on installing 6 numbers of 310W solar panels with 60A, 150V Schneider XW 60 MPPT CC, this is a phased Installation, the short circuit current of the PV is about 9A, while the max operating current is about 8.2A, the VOC is 42V and the max operating voltage is about 36V. The battery bank and Inverter operating voltage is 24V (already existing) I just want opinion from the SME on the best combination for better efficiency, from the look of things this could be 2 arrays (2 X 3PVs In series) or 3 arrays of (3 X 2PVs in series). Which do you think will be of better efficiency, appreciate all comments |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 8:15am On Jul 02, 2017 |
bodeface: You stated you had an existing 24v inverter system , simply go for 2×2 PV module configuration (3×2pv in series).. The other is most suitable for a 48v operating system.. You didnt state DC breaker amps , pro solar roof mount kit etc, contact me for accessories if interested .. Happy Sunday- Cheers ! |
Re: Solar Energy, A Complement To FTA by Dam5reey(m): 8:21am On Jul 02, 2017 |
bodeface: First option, Higher Voltage with lower current... Make better Cable efficiency 1 Like |
Re: Solar Energy, A Complement To FTA by chris81964(m): 8:34am On Jul 02, 2017 |
We had a good first half and look forward to an even better 2nd half. The team at AWPS Renewable Energy, LTD, thank you all for your support, patronage and kind words. InStrat Global Health Solutions, Ltd., Africa’s leading implementer of turnkey mobile health solutions and AWPS Renewable Energy, Ltd., Nigeria’s #1 provider of premium quality solar power, have signed a historic contract for AWPS Renewable Energy to provide solar power to 21 urban and rural heath centers in Abuja and Kano Nigeria. InStrat Global Health Solutions, Ltd’s technology, allows clients to implement heath care delivery in low resource settings. AWPS Renewable Energy, Ltd., will provide high quality, reliable and cost effective solar power to InStrat Global Health Solutions, Ltd., client centers for high speed satellite internet in 18 centers, in Kano and 2 in Abuja. The contract was signed by AWPS Renewable Energy, Ltd., President, Mr. Christopher “Dr. Solar” Onwuasoanya and the founder and CEO of InStrat Global Health Solutions, Ltd., Mr. Okey Okuzu. The project will be completed and implemented by the end of July 2017. http://atlanticwastepower.com/2017/07/awps-signs-history-making-contract/ 1 Like |
Re: Solar Energy, A Complement To FTA by DMerciful(m): 10:25am On Jul 02, 2017 |
My rèco is to go for 2*3 configuration so that combined Voc is 84V. Use 16mm cable or more for ur installation. Doing 3*2 will give u Voc of 126V and for a 24v system, the pull down voltage will be too much so as kiekie1 said, this is best for 48v system. Cheers bodeface: 2 Likes |
Re: Solar Energy, A Complement To FTA by DMerciful(m): 10:26am On Jul 02, 2017 |
This weather is not helping at all. My solar system cannot shout! |
Re: Solar Energy, A Complement To FTA by JohnKester: 11:52am On Jul 02, 2017 |
Re: Solar Energy, A Complement To FTA by bodeface: 1:28pm On Jul 02, 2017 |
Thanks to all the SMEs for all your inputs, this has reinforced my understanding, I will set it up as an array 2*3 configuration as 84V VOC, the wire run between the combiner box and the PV array is just about 5-6 meters, I sized my cable to be 6mm2 and the combiner to the Solar charger is just about 6 meters, the cable was sized to be 16mm2, this should all be adequate. @Kiekie Thanks for your input, How much is your Surge Arrestor both DC and the AC, all other items already in stock DMerciful: 1 Like |
Re: Solar Energy, A Complement To FTA by mcTrinity(m): 2:15pm On Jul 02, 2017 |
DMerciful: Lolz... the rain is doing its work! |
(1) (2) (3) ... (265) (266) (267) (268) (269) (270) (271) ... (1855) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: dollarnaira, sheDD(m) and 1 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 88 |