Re: Solar Energy, A Complement To FTA by Saipro(m): 7:43pm On Jul 19, 2017 |
pranil: Nice going! I'd been dreaming of such panels. Didn't know they actually exist already. Let's hope they make their way into our market soon. The numbers seem fantastic though |
Re: Solar Energy, A Complement To FTA by pranil(m): 7:53pm On Jul 19, 2017 |
Saipro:I have a Victron Bidirectional Quattro( multi) so I am planning to try using a small Grid tie Inverter with solar panels and a current sensor - See atttached PDF - The sensor can be similar to this -https://www.ev-power.eu/Measure-Test-Tools-1-1/Current-Monitoring-Relay-PRI-52-AC-0-5A-25A-CE.html#tab2 A soladin or APS grid inverter will be ideal choice ( 1 KW to 2 KW) - http://www.mastervolt.com/products/solar-inverters/soladin-1000-web/ APS- http://www.apsmicroinverter.nl/ The idea is that whenever the current sensor senses the Current flowing from PV panels to Multi or from Multi to PV panels the sensor after 1 min will switch off the Powercontactor feeding the water heater/Boiler - The contractor timer waits for 10-20 min and resets if there is no current flow then the water heater remains connected till the current sensor switches it off the idea being that in daytime the solar PV inverter will directly feed power to water heater. After midday when the heater gets thermal cutoff there is no power draw from heater the excess energy is fed back through multi to loads and battery You can set timers( time of Day) and even a bypass switch to feed the heater directly from Multi in winter or night if some top up heat is required. Alternatively, a time of the day timer can be fitted to disconnect heater in the evenings /night to prevent draw from batteries ( in case your inverter is not passing the grid to the heater) Since the grid tie inverters have efficiencies between 95-97 % you are using the full yield and compared to the DC heating element you can locate your panels anywhere and heater anywhere in the house as long as they are connected at AC side Also, the solar panels can be smaller say 500 watts ( set current control higher than the difference of Panel average yield and heating load) OR They can be much larger ( set current control or a lower value say 1 to 2 amps) In my case I am planning to use a similar setup but instead of heater use it for running an air conditioner - The one advantage I have is that the AC is inverter type. so it ramps up the load from 100 Watt to 900 watts in linear fashion giving ample time to the contractor to act and disconnect if it is a cloudy day without much tick toc effect
|
Re: Solar Energy, A Complement To FTA by Saipro(m): 8:10pm On Jul 19, 2017 |
pranil: You really are into life hacks! 1 Like |
Re: Solar Energy, A Complement To FTA by babaegun(m): 9:15pm On Jul 19, 2017 |
@Pranil hmnn, the rate at which you are going, Am sure your house will be full of gadgets and complicated designs . Did you study electronics? Abi you just an enthusiast. From your solar, down to your water pump. In fact, the water pump setup scare me self. Hope your wife dey enjoy all this your fun too. I have my raspberry pi 3. It is amazing. I think you need to share the MTQQ and NODESCRIPT concept, design and etc etc with me. 2 Likes |
Re: Solar Energy, A Complement To FTA by efuro(m): 9:41pm On Jul 19, 2017 |
babaegun: I have 300w AC Areo dry Iron I have been using since 2009 when I have not dreamt of inverter or solar. it so efficient that it melted the lower plastic casing and it's thermostat knob making me to hate using it for sometime. Last year, with the fear of recession and the need to protect my battery bank, I had to dig it out from my dusty store & insulate the casing from it's element or iron base. now I enjoy pressing cloths anytime of d day with just 300w on my 2kva/1600w inverter. I have since dumped my Siemens 2200w water iron. for those looking for inverter friendly pressing iron, check it out maybe you will find an improved version of it. 1 Like
|
Re: Solar Energy, A Complement To FTA by jazzman2(m): 9:46pm On Jul 19, 2017 |
pranil: Oga Pranil, after all your previous rantings about the supposed "Ilegality" of using grid-tie inverters in an off-grid system, you are now dreaming of implementing an AC-coupled system using the same grid-tie inverter (in this case microinverters hard-coupled to PV panels)? You are trying to implement a variation of an off-grid, AC-Coupled system with grid-tie inverters called a "GRID-FREE" system, yet you argue that grid-tie inverters must inject into the national grid. Please explain to the forum how you plan to stabilize the national grid and also show us all the NEC / NERC code compliance certificates and permits that must be issued to you by our beloved 1 Like |
Re: Solar Energy, A Complement To FTA by Saipro(m): 10:29pm On Jul 19, 2017 |
jazzman2: I thought we let this go a while back. The hazards of a self-contained micro-grid cannot be over-emphasized but is beautiful when properly setup. If you follow SMA installations, you'd discover it's the preferred mode of using Sunny Boys in an off-grid setup (backed by a Sunny Island master). Chris on this forum seems to have installed quite a few units and I vividly remember seeing pictures of a Sunny Boy/Sunny Island combo setup by his company on this forum. He could lend us his practical experience rather than us drawing abstractions. |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 7:47am On Jul 20, 2017 |
FAIRLY NEW Recently upgraded this systems and all up for grabs wit its warranty seal still intact .. All working "inverting/charging" like new ; -Mercury 3kva 24v LCD display pure sinewave power inverter worth 200-220k for brand new -Sinergy 3.5kva 48v LCD display pure sinewave power inverter -Fairly new 200a batteries "Loading soon" Strictly for interested clients as its half the price of its brand-new Call >> +234-813-503-1951
|
Re: Solar Energy, A Complement To FTA by Barezzi(m): 9:28am On Jul 20, 2017 |
Way to go Pranil... Have you jettisoned the Geywiserrobot project? It seems the best approach to solve the wahala below, as it's the same issue I'm faced with. DUNKA: |
Re: Solar Energy, A Complement To FTA by aroseyi(m): 10:09am On Jul 20, 2017 |
If you need cccam account for Tvsat Africa 16e 9e cccam account Full European cccam on hotbird and hispasat Cccam for star time 5e Canal reunion and Zap 36e cccam Qsat account Kwese sports decoder Whatsapp me +2348062272279 Skype : ancl.sy |
Re: Solar Energy, A Complement To FTA by babaegun(m): 1:21pm On Jul 20, 2017 |
efuro: Wow! That's a good one. Hope it is still in the market. |
Re: Solar Energy, A Complement To FTA by Saipro(m): 2:03pm On Jul 20, 2017 |
kiekie1: It would seem you are right. Just had a discussion with their sales manager and he confirmed your assertion. And he said Rubitec does not have/market their own branded inverters. 1 Like |
Re: Solar Energy, A Complement To FTA by JUO(m): 2:50pm On Jul 20, 2017 |
Saipro:I own 2pcs one 500w that operates at 400w and one 100w that operates at 35w. Works very well for me
|
Re: Solar Energy, A Complement To FTA by BRIGHTSOLAR(m): 2:50pm On Jul 20, 2017 |
LUMINOUS INVERTER 1.5KVA/24V ECO 73,000 3.5KVA/48V 180,000 5KVA/96V 350,000 MICROTECH INVERTER 1.1KVA,12V 50,000 1.6KVA/24V 75,000 3.5KVA/48V 170,000 MUST POWER STAR INVERTER 1KVA 1000W 12v 95,000 4kva 3000W 24V 250,000 5kva 4000W 48V 300,000 6kva 5000W 48V 350,000 7.5kva 6000W 48V 450,000 BATTERY GLT BATTERY 12V/100AH 55,000 GLT BATTERY 12V/150AH 73,000 GLT BATTERY 12V/200AH 100,000 ZEEDIX BATTERY 12V/100AH 45,000 ZEEDIX BATTERY 12V/150AH 70,000 ZEEDIX BATTERY 12V/200AH 90,000 BATTERY RACK BATTERY RACK 2 BATTERY 15,000 BATTERY RACK 4 BATTERIES 30,000 BATTERY RACK 8 BATTERIES 50,000 CHARGE CONTROLLER ROY SOLAR SERIES 20A 12/24V PWM CONTROLLER 20,000 30A 12/24V PWM CONTROLLER 25,000 40A 48v PWM controller (LED) 50,000 30A 96v PWM controller (LCD) 120,000 60A 48v PWM controller (LCD) 95,000 SOLAR PANEL 150w M-40,000 200w M-45,000 260w M-60,000 310w M-75,000 Bright Solar Power ONLINE STORE FOR SOLAR PRODUCTS SOURCING Call-07058562938 |
Re: Solar Energy, A Complement To FTA by JUO(m): 3:03pm On Jul 20, 2017 |
MidNite Solar MNSPD-300-DC-price=50k 080-987-337-09 1 Like
|
Re: Solar Energy, A Complement To FTA by Monlo(m): 3:54pm On Jul 20, 2017 |
aroseyi: You will never change.Stop spamming this thread!What has this got to do with solar? 2 Likes |
Re: Solar Energy, A Complement To FTA by efuro(m): 6:34pm On Jul 20, 2017 |
@ babaegun I don't know if it is available again. it's a long time |
Re: Solar Energy, A Complement To FTA by efuro(m): 6:35pm On Jul 20, 2017 |
JUO: Ur lucky to have dem. it is no load to ur setup. |
Re: Solar Energy, A Complement To FTA by pranil(m): 7:42pm On Jul 20, 2017 |
jazzman2: you have every right to call me out . I only pointed out the dangers both technical and legal and left the choice to consumers in the absence of any regulation on GRID Tie since the community is full of D.I>Y enthusiast who might lack the knowledge to make a suitable decision . May be it was misunderstood F.y.i. in my case is I am using a islanding relay and a Em24 Energy meter to ensure that the grid export is prevented along with PV assitant and a Venus GX If you want I can send you my discussion with Victron ,EVpower and ,d Soladin on applying Microinverter. Even Victron has not done it before and I am trying to test a solution Infact both Soladin and victron advised me against it as it has never been done before making me more curious to try it out |
Re: Solar Energy, A Complement To FTA by pranil(m): 7:52pm On Jul 20, 2017 |
babaegun: My wife complains that the house should have it's own user manual I am mainly using my Pi3 to run emoncms with ICC to mintor my Axperts ( which power the AC) and same PI is also attached to Touchscreen displaying the VRM from Victron /Venus GX The another pi is only running measureit with currentcost to measure whole house consumption and uploading to PVOUT ( thats how I posted teh booster data) I am now trying to get the unified dashboard for Victron and Axpert ( ipower) and other stuff using http://freeboard.io/ Currently stuck on some code on Github which needs to be modified as I have no Knowledge of JAVA- If any inhouse experts are there I can use the help 1 Like |
Re: Solar Energy, A Complement To FTA by bigrovar(m): 9:31pm On Jul 20, 2017 |
pranil: So the VRM works with a raspberry pi lcd making it essentially a CCGX? I tended to do just that. I read the touch screen part has some driver issues since the code has not been tested on the Venus image your thoughts |
Re: Solar Energy, A Complement To FTA by GeorgeD1(m): 9:41pm On Jul 20, 2017 |
DUNKA: dunka, plumbing does not need to be a headache for you when it comes to solar water heating. first of all, get the package and measure the total height of the assembly, i.e from the top of the water heater tank to the foot of the frame carrying it. add one or two feet to this value. that would be the clearance from the bottom of the main water tank to the top of the water heater tank. after installing the water heater, run your hot water lines direct from the hot water outlet to the inlet of your existing electric water heater inlet. use a t-connection copper tube. you only need to bore a little hole from outside your bathroom to gain access to the existing plumbing.use the t-connection to introduce the hot water into your bathroom. |
Re: Solar Energy, A Complement To FTA by Saipro(m): 1:00am On Jul 21, 2017 |
JUO: Here you are puncturing neat holes in my elegant speculation. Nice one. In final defence, I would claim those seem to be traveler type irons, renown for portability and low energy consumption. |
Re: Solar Energy, A Complement To FTA by DUNKA(m): 2:18am On Jul 21, 2017 |
GeorgeD1:Thanks a million . I will run it by my plumber and see how it goes. What did you do with your former water heaters? |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 4:47am On Jul 21, 2017 |
GeorgeD1: just wondering...so for an old house....one would have to run the hot water pipe from the solar heater to the various hot water points in the house?...........if yes..that would be untidy and a bit difficult in some builds. for a new house having a central hot water piping traverse the whole house might be a tidier option...though when one factors in the cost of the copper pipes...it might add up to much...especially for a large build eg 5br duplex.. what are your thoughts/advice? |
Re: Solar Energy, A Complement To FTA by GeorgeD1(m): 10:15am On Jul 21, 2017 |
DUNKA: dunka, i dismantled them and gave them away. there was really no point in keeping them around as i wouldn't be needing them anymore. and, several months down the line, i'm still glad i took that step. |
Re: Solar Energy, A Complement To FTA by GeorgeD1(m): 12:04pm On Jul 21, 2017 |
earthrealm: earthrealm, yes, for a house with an already existing electric hot water plumbing network, you definitely have to run your solar water heater hot line to the various points but its not really as untidy as you think. provided it has an existing hot water line, you can retrofit the solar water heater outlet to link up with your existing plumbing system. for a new house, it becomes even better. the cost of copper plumbing drops drastically because in this instance you can run your hot water line directly either from the roof downwards or through the floor of the house. |
Re: Solar Energy, A Complement To FTA by pranil(m): 3:06pm On Jul 21, 2017 |
GeorgeD1: Problem is that my cold water is boosted at 3 Bar which means I have to boost Hot water also with a booster to match user expectation on temperature versus mixer handle position. Also, Hot water boosters /recirculation pumps are on the pricier side How much outlet temperature normally you get on a sunny day and cloudy day. I might use the hot water as preheated water for one boiler /heater used for the main bathroom and later think of adding other rooms Where did you get your system from? Any issues with the pumps controllers ? |
Re: Solar Energy, A Complement To FTA by pranil(m): 3:09pm On Jul 21, 2017 |
pranil: any reviews for this unit - https:///protek-solar-water-heater-200l-with-heating-element-1647054 |
Re: Solar Energy, A Complement To FTA by JohnKester: 3:14pm On Jul 21, 2017 |
pranil: I have the 300L, which has been in use for almost 2 years. it is awesome and I have not had a single issue with it since it was installed. Just install and forget it while you continue to enjoy your hot water. Cheers 1 Like |
Re: Solar Energy, A Complement To FTA by pranil(m): 3:23pm On Jul 21, 2017 |
bigrovar: the Venus GX ( Same as CCGX ) is here - https://github.com/victronenergy/venus/wiki/raspberrypi-install-venus-image Runs very well I ran it for few months before getting the Venus GX ( i wanted the Can bus and Tank levels) The 7 inch display for RS components is the official version with case - No driver required - http://uk.rs-online.com/web/p/graphics-display-development-kits/8997466/ Lagos dealer is below
|
Re: Solar Energy, A Complement To FTA by kiekie1(m): 8:37pm On Jul 21, 2017 |
kiekie1: HURRY ! Very good fairly new 12v 200a batteries up for GRABS . Dial me up now .... #limited stock |
(1) (2) (3) ... (271) (272) (273) (274) (275) (276) (277) ... (1855) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: sheDD(m), Akaza(m), samir101ng(m) and 2 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 116 |