Re: Solar Energy, A Complement To FTA by dicksonadams(m): 8:47pm On Oct 25, 2017 |
Guys please I need your recommendation I was previously using an mpower 200ah battery and after 2 year the guy man no dey last reach 1hr again. Please can the guru in the house recommend a strong battery to buy . Thanks in advance |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 11:57pm On Oct 25, 2017 |
dicksonadams:Try quanta, Whatapp 08117398294 for options nd price |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 5:23am On Oct 26, 2017 |
dicksonadams: if its just a 1 battery setup...then it will always fail within 1,2,or 3 yrs... as most users usually exceed the manufacturere recharge cycles soon enuff. 2 batt setup also suffers the same fate... only way you can prevent such is if you have an intelligent inverter with dod switch..wch u will set to 40 or 50% so it stops draining your battery when it gets to that level. a 12v 200ah battery contains roughly 2kwh energy factoring in losses and inefficiency, at 50% dod u now hv 1000w, so it can only power a 100w load for 10hrs, 200w load for 5hrs, 300w load for 3hrs etc 1 Like |
Re: Solar Energy, A Complement To FTA by mcTrinity(m): 6:28am On Oct 26, 2017 |
dicksonadams: Deka Zenith Gaston Quanta Ritar Sukam Safepower Luminous |
Re: Solar Energy, A Complement To FTA by Dam5reey(m): 7:30am On Oct 26, 2017 |
earthrealm:In addition... If you discharge at higher amperage you get lower back up time 100w load will give you about 11 hours, 200watts 4 hours and 300watts about 2hours... A 20HR rated 200AH battery should not be discharged at more that 130Watts (10A) If your load is 300watts then recommended battery is 2* 200AH |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 12:05pm On Oct 26, 2017 |
dicksonadams: Hello, if you are a flooded battery fan, contact me for USA trojan battery 12v 200a -N130,000. If you are for agm SMF battery : - Hoppecke 12v 90a N96,000 -Long battery 12v 200a N120,000 -Gennex 12v 200a N105,000 Note: USA trojan sealed agm batteries will soon be in stock ! Smartcell global services 081-350-31951 1 Like |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 1:14pm On Oct 26, 2017 |
makavele: Sold 1 Like |
Re: Solar Energy, A Complement To FTA by Saipro(m): 9:32am On Oct 27, 2017 |
NiyiOmoIyunade:Very true. Try substantial oversizing with epSolar and one would soon be shopping for a new CC. |
Re: Solar Energy, A Complement To FTA by Saipro(m): 9:34am On Oct 27, 2017 |
pranil:Trust Pranil for his fact-finding missions. As always, you dig deep for relevant info and share unabashedly. Personally, I love you. 5 Likes |
Re: Solar Energy, A Complement To FTA by kianoe4400(m): 5:35pm On Oct 27, 2017 |
dicksonadams: Kindly reach me on dis number for new telecoms battery, custom requested at very affordable price..pure inverter battery.. 08187293417 whatsapp |
Re: Solar Energy, A Complement To FTA by pranil(m): 6:19pm On Oct 27, 2017 |
Saipro: Thank you. My primary aim to help people. and also get knowledge in the process. Nairaland gives a unique local perspective which no other forum can bring. I have made many friends here over the years some of them I have not even met in person. 1 Like |
Re: Solar Energy, A Complement To FTA by BlackBaron: 7:34pm On Oct 27, 2017 |
@Zeestone99,(Already chatted a bit yesterday) GeorgeD1 (has the most extensive SP project here I think) Please, can I indulge your knowledge about building a good solar power project. I have read and still learning about SP. I am looking for one in excess of 4KW plus or more (if needed)to run a bungalow or two. Items such as fridge, tv, low energy LED, washing machine(?), microwave (?) Say I had the opportunity to purchase all I wanted from abroad at a fairly cheap price, would that make a lot of difference versus buying all from Nigeria? I have possibilities of getting for example solar panels deep cycle batteries (from AGM to lead acid) Inverter Would just like to draw on your knowledge on what could be bought to make this set up a very good and worthy setup. |
Re: Solar Energy, A Complement To FTA by dicksonadams(m): 8:57pm On Oct 27, 2017 |
kianoe4400: What brand do you sell? |
Re: Solar Energy, A Complement To FTA by Mozabo(m): 5:51am On Oct 28, 2017 |
Want uninterrupted power supply? Here are just a few reasons why you should Stay connected to the world, be Comfortable at home, work efficiently, preserve perishables, give your loved once the best. Getting results and taking charge of your life requires you cutting your own part despite the challenges. stand out from the crowd , power generation is too expensive, constantly buying fuel and repair of generator ,waking up to change over when light comes ,the noise their just has to be a better way to save money on energy bills, be more productive ,have a better resting environment enjoy fun with family and loved ones. We can imagine how inconvenient it is to generate your own power, coupled with the cost to maintain a generator and the problem of buying good fuel which isn’t readily available and then the noise ahhh!!!. Mozabo Engineering has been working in the Energy sector since 2012 with a well qualified team and recently nominated as Africa’s Most Innovative Quality Electrical services provider of the year 2017 by AQAA We would love to be the one you partner with when you decide to install a solar system Call us today for our current rates as prices 08038702279 Our solar installation can help you Save money on fuel and maintenance, No noise which means you sleep better at night and be more productive in the mornings , No change over wahala, your Food gets preserved ,Family can watch TV programs when they want ,Laptops and Mobile is always charged. Little or not enough power supply can affect lighting visibility which can lead to domestic accidents, a sense of insecurity Low productivity, Lots of wasted perishables food and then the High cost of running a gen set, fuelling and maintenance P/S Here is a link to our blog on inverter and how it works Perhaps a deeper understanding would help guide your choice www.mozabo.com/wp/inverter/ 1 Share
|
Re: Solar Energy, A Complement To FTA by foonshur(m): 9:21am On Oct 28, 2017 |
Mozabo:bros, no be car battery I dey see for una picture there? 6 Likes |
Re: Solar Energy, A Complement To FTA by liquidcrystal73(m): 12:37pm On Oct 28, 2017 |
My epever doesnt show battery SOC How to fix this ?
|
Re: Solar Energy, A Complement To FTA by liquidcrystal73(m): 1:57pm On Oct 28, 2017 |
And battery never enters FLOAT Battery has been over 14.2v since 9am and inverter is off but still showing BOOST
|
Re: Solar Energy, A Complement To FTA by kiekie1(m): 2:22pm On Oct 28, 2017 |
liquidcrystal73: Your mppt has no issue.. It depends on your preset value & timing for charge hours . if you tamper with old boost/equalization setting of 60 min to 1 hr or above , it stays on boost for longer period of time before reaching float mode ! You can freely contact me for other enquiries ... Smartcell global services 081-350-31951 1 Like 1 Share |
Re: Solar Energy, A Complement To FTA by liquidcrystal73(m): 4:42pm On Oct 28, 2017 |
Battery finally floated around 2.21pm 220W draw and still floating Test run passed!!! Kiekie, thumbs up! You too much !!! 1 Like 1 Share
|
Re: Solar Energy, A Complement To FTA by JUO(m): 9:16pm On Oct 28, 2017 |
liquidcrystal73:the cc will do better if you double/series the panel voltage. For you to achieve this on epever you have over 300w of panels |
Re: Solar Energy, A Complement To FTA by liquidcrystal73(m): 10:45pm On Oct 28, 2017 |
JUO: Just a test run, Panels are quadruple that power. i believe series/parallel don’t matter for mppt because power cannot be created or destroyed just converted from one form to another if u do the calculation; it amounts to the same power whether via series or parallel i might be wrong though. |
Re: Solar Energy, A Complement To FTA by dapsyra(m): 11:51pm On Oct 28, 2017 |
liquidcrystal73: Yes, it amount to the same power at the point of generation, that is, Panel end but different at the CC end due to cable loss. Parallel connections will result in higher current, lower voltage. The higher the current, the more the power lost in the cables Series connection will result in lower current, higher voltage thereby minimising the power lost in the cable. If you are not using appropriately rated cables for the installation, the cable loss can be very significant. 2 Likes |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 7:51am On Oct 29, 2017 |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 7:52am On Oct 29, 2017 |
BlackBaron: It all depends on choice, u can buy here or import, jst get the right Materials, u ll b fine. |
Re: Solar Energy, A Complement To FTA by dicksonadams(m): 8:39am On Oct 29, 2017 |
zeestone99: Great please how much is 200ah thanks |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 1:40pm On Oct 29, 2017 |
dicksonadams: |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 1:48pm On Oct 29, 2017 |
dicksonadams:Quanta 130k Whatapp 08117398294 |
Re: Solar Energy, A Complement To FTA by pranil(m): 3:23pm On Oct 29, 2017 |
Epever users I need tips and tricks I just Got EPEVER Tracer 4210 A , SHI 1000 Pure inverter, Wifi Box , USB cable and temp sensor - all 24 Volts. In preparation for my wind turbine experiment, 12 V 150 AH AGM . The idea is to use my excess equipment to power BQ independently and feedback excess power to main house using Ac coupled grid-tied micro inverter Two 300 watt wind turbines on their way On first look, I am disappointed on multiple fronts The Wifi box does not work with inverter but works with charge controller ( both have RS485 com ports) The USB cable works with Inverter but not with charge controller ( explanation next point) For PC there is no software for setting monitoring for charge controller ( only android - not even in play store ) For inverter, there is android software but since the wifi box does not work ( not even powers on) no way of checking No back light on CC at all ! not even with a button The whole software experience is clunky at best. The hardware looks nicely built through with proper heatsinks and terminals etc. Managed to make 1.5 KWH from my old 600 watts Chinese no brand panels ( rebuilt junction box, corroded tracks etc.) |
Re: Solar Energy, A Complement To FTA by liquidcrystal73(m): 5:02pm On Oct 29, 2017 |
Dead controller 24 hours into test-run . . . Please advise CC: Pranil, bigrovar, zeestone99, pranil, DMerciful, Saipro, Kiekie1
|
Re: Solar Energy, A Complement To FTA by liquidcrystal73(m): 5:05pm On Oct 29, 2017 |
Controller just stopped working mid-day and almost fried my 12v bank . . .. battery voltage went high as 16v
|
Re: Solar Energy, A Complement To FTA by DUNKA(m): 5:58pm On Oct 29, 2017 |
liquidcrystal73:Bros sorry for the loss 3 Likes |
Re: Solar Energy, A Complement To FTA by liquidcrystal73(m): 6:12pm On Oct 29, 2017 |
DUNKA: Just about 36 hours ! A "wonderful loss" it is ! Mr. K K; come and carry your CC Tnx 2 Likes |
(1) (2) (3) ... (299) (300) (301) (302) (303) (304) (305) ... (1822) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: kewhos(m) and 2 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 65 |