Re: Solar Energy, A Complement To FTA by makavele: 8:18pm On Nov 23, 2017 |
NiyiOmoIyunade: Its true . . the average DB has a single (or like in my case, dual bus bars) where all neutral wires terminate . . But it would be bad practice to wire all sockets and switches in the house in a common neutral loop and stretch one single piece of wire to the DB / / / heck; nobody does that . . All sockets and switches have individual neutral lines stretched out to the DB and I guess you know why already. |
Re: Solar Energy, A Complement To FTA by makavele: 8:18pm On Nov 23, 2017 |
mank1234: Oya, I have accepted, lets move on |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 8:19pm On Nov 23, 2017 |
Zeestone and I have this argument with every installation we do together. He argues that all neutral is common even within the inverter internal circuitry and this is true. Again, I note that the NEC retained the common neutral standard for backward compatibility though they do not encourage it - they recommend that the neutral bus/ wire be at least equal to or twice the size of the live wires. When I look at the average household electrical distribution panel, one sees that all the neutral wires terminate on one bus bar and same for the earth/ground wires - so I have been forced to grudgingly accept his old-school method. That said if one breaks both the live and neutral wires with a double pole breaker, then we can ensure that anything on the load side of the breaker is electrically isolated in the event of a breaker trip - this is regardless of whether the neutrals are common at source or not. makavele: |
Re: Solar Energy, A Complement To FTA by JUO(m): 8:20pm On Nov 23, 2017 |
NiyiOmoIyunade: 1. Servo stabilizer 2. Online ups 3. Inverter with AVR Any of these will solve the problem The equipment is how many watts? I have 500w/12v with AVR output is 220v from 145v Get this ups and rest. You can even see it in the dust bin and buy cheap or get a new 1 Like
|
Re: Solar Energy, A Complement To FTA by kiekie1(m): 8:34pm On Nov 23, 2017 |
JUO: I easily regulate my servo stab O/P variable to my choice.Its more advisable to use trusted servo stabilizers on sensitive equipments. Online ups also have a reliable transfer time-steady output ! The only issue with the above sampled APC ups is that it auto rejects/selects generator with flickering frequency... Cheers |
Re: Solar Energy, A Complement To FTA by mank1234(m): 8:36pm On Nov 23, 2017 |
makavele: You'll get different result because of differences in internal resistance, differences in age etc and not because the underlining theories are wrong. Since you don't believe in theories(battery test result), why then do you look at battery data sheet when researching about a battery to buy? I'll not respond to this anymore; not that you're right but so that the sanctity of this wonderful thread is maintained. |
Re: Solar Energy, A Complement To FTA by makavele: 8:50pm On Nov 23, 2017 |
mank1234: Mankinde, let me rest and if you're an adept reader; you would know that most seasoned installers will tell you to throw away the battery spec sheet. |
Re: Solar Energy, A Complement To FTA by dejidotun2000(m): 9:08pm On Nov 23, 2017 |
And why would they do that? makavele: 2 Likes |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 9:15pm On Nov 23, 2017 |
dejidotun2000: I guess he was speaking of low quality Chinese batteries or rebranded battery versions . Richmond sent pics of few jobs he cleaned up some months ago and we still see so many funny installers roaming the streets of Lagos as a case study . I have so many electricians in my hood admiring solar jobs and trying to learn intricacies in inverter - solar installation the wrong way tho ! 1 Like |
Re: Solar Energy, A Complement To FTA by makavele: 9:23pm On Nov 23, 2017 |
dejidotun2000: Cos those are factory-based under STC which don't apply to real life . . . Take for example, a battery spec sheet might tell you to charge your battery to 14.1V for optimum performance And you might be living where you do not have enough sun-hours to float your battery. What do you do? Increase bulk charge to say, 14.6 and let it smoke . . . ** and for those who might want to argue, it's called "max smoke" in the solar world & perfectly safe*** By the time the sun goes down; you would be closer to 100% SOC If you seem to be smoking too much, reduce to 14.4 and try again . . no battery spec sheet will tell you this. so forget what the spec sheets say, they are theoritical and meant as guides throw it away, and face real conditions applicable to you and you only. 1 Like |
Re: Solar Energy, A Complement To FTA by makavele: 9:30pm On Nov 23, 2017 |
kiekie1: lol but no ! |
Re: Solar Energy, A Complement To FTA by Jamzig1(m): 9:36pm On Nov 23, 2017 |
kiekie1:Speaking of Richmon74...He has been off grid (off the Forum) for quite a while 1 Like |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 9:39pm On Nov 23, 2017 |
makavele: I have confirmed you as a real "practical man" abinitio . I think i get where you are coming from but theoretical approach acts a a guideline to practical approach and that's solely the basics k.. Manuals are meant to be studied in any situation , guess you meant they are thrown away because pro-installers already know about the said product. I also know all batteries or inverters ain't same. We have disparity between gel-agm-flooded batteries likewise some inverters which don't last long when you install with "common neutral" like old model Cyber power etc... |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 9:43pm On Nov 23, 2017 |
Jamzig1: Yes Sir, guess he has his reasons .. We seldomly see down here in Lagos .. He drove pass me on few occasions and he is fine 1 Like |
Re: Solar Energy, A Complement To FTA by dejidotun2000(m): 9:47pm On Nov 23, 2017 |
Data sheets give you values other than at STC. makavele:
|
Re: Solar Energy, A Complement To FTA by makavele: 9:48pm On Nov 23, 2017 |
kiekie1: When I meant "throw away" I believe he understood what I meant. A figure of speech, which means don't depend and/or put all your life on a manual; especially for items like batteries, where the results will vary according to user approach. You dig? And your italicized use of the phrase "practical man"; don't know if I should take it as a compliment or a sub. In the real practical sense of it, I had posted an image days back and had related with zeestone99 . . . I had lightening strike my house and oh yes, it took out my external battery charger with it and killed my inverter charging functionality (don't preach to me about a lightening arrestor,, i know i know ).... . Inverter was outputing 0.23Amps to charge a depleted battery. days later, I single-handedly brought it back to life. How i did it, remains to be desired !!! |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 9:53pm On Nov 23, 2017 |
makavele: That's a compliment .. Good to know you personally revived your system from surge , try do a proper grounding and if possible , get an anti surge device within 20-50k interval pending on efficiency-make to avoid expensive futuristic damages. Cheers ! 1 Like |
Re: Solar Energy, A Complement To FTA by makavele: 9:55pm On Nov 23, 2017 |
kiekie1: Thanks for the compliment, sir !!! 1 Like |
Re: Solar Energy, A Complement To FTA by pranil(m): 10:29pm On Nov 23, 2017 |
pranil: Gentlemen The battery terminals work like a DC busbar unless there is a real busbar. All this current exchange happens only in the terminals and only excess current ( +ve) goes INSIDE the battery for chemistry to charge the battery or if the load is higher than battery excess current is generated by chemistry and delivered to the load in addition to CC current As long as the CC is maintaining higher voltage than battery the entire current will go to the load . Now you can see the reason for Hybrid inverters like ipower/zinnox/gennex where the current going to the battery is limited by the inverter but Current produced by the CC can be directly consumed by the load as the busbar is formed inside the inverter. At one time i was running 400 AH bank ( max 40 amp charge setting) with 5 KW panels without any issues. Any excess load was automatically supplied by PV powe |
Re: Solar Energy, A Complement To FTA by Zeestone9: 11:15pm On Nov 23, 2017 |
NiyiOmoIyunade: Even the almighty tri star mppt 60 we both use, use common neutral for pv n ba3 we ll leave the case for other oga's @ d top to shed more light. |
Re: Solar Energy, A Complement To FTA by Zeestone9: 11:23pm On Nov 23, 2017 |
kiekie1: So u knw he's Mr practical, and as far as he(my client) and I are concerned, he has no solar setup yet, the lil he installed was to get familiar with the system, hw it works, do's n don't... His main setup wud b installed this week with all necessary equipment in place. Cheers |
Re: Solar Energy, A Complement To FTA by makavele: 11:48pm On Nov 23, 2017 |
Zeestone9: while the epever uses common live . . if u go do your neutral tricks here; u don buy market be that oo; lol |
Re: Solar Energy, A Complement To FTA by Zeestone9: 12:54am On Nov 24, 2017 |
makavele: jst ring me 4 supplies lol 1 Like |
Re: Solar Energy, A Complement To FTA by Zeestone9: 9:03am On Nov 24, 2017 |
Hello house and fellow installers, contact me for your solar panels n other products at affordable prices. We also do payment on delivery. Solar panels Sunshine solar 300watts mono=58k 300watts poly = 55k 250watts mono=50k 250watts poly=46k 200watts mono - 42k 200watts poly - 37k 150watts mono - 29k 150watts poly - 27k Other products in stock includes Canadian solar, suntech, flames etc Inverters Felicity 3.5kva/24v( 35amps charging current) - 150k 5kva/48v ( 30amps charging current) - 185k 7.5kva 48v (40amps charging current) - 340k 10kva 48v- Other products includes sukam, vilpower, microtek, axpert etc Charge controller Ep solar 60amps - 129k Ep solar 40amps - out of stock Batteries (200ah) Quanta - 130k Long - 115k Other products in stock includes luminous, genus, monbat, toplight etc Call/watapp 08117398294 or email Info@monzpowersolutions.com You can also like our page on facebook.com/monzpowersolutions Ep solar 40amps now available 75k Thanks for your patronage keep the calls coming... |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 10:17am On Nov 24, 2017 |
BLACK FRIDAY SALES IS ON Hurry ! Keep the calls coming - Canadian solar 340w mono crystalline module . price=N82,000 Quick Overview; Maximum power, Pmax - 340 Wp Open circuit voltage, Voc - 46.2 V Maximum power point voltage, Vmpp - 37.9 V Short circuit current, Isc - 9.48 A Maximum power point current, Impp - 8.97 A Module efficiency - 17.49 % Max System Voltage: 1000VDC - USA Trojan 12v 200a J200RE deep cycle batteries.. Price= N128,000 Quick Overview Model: J200RE with Bayonet Cap Battery: Flooded/Wet Lead-Acid Battery Capacity: 12V 200Ah / 20Hr Rate Cyclic Use: 30% DOD - 2750 cycles Cyclic Use: 50% DOD - 1750 cycles Dimensions (LxBxH): 380mm x 176mm x 352mm Terminal Height: 371mm Weight: 60kg Bulk Charge: 14.82V, Float charge: 13.5V, Equalization Charge: 16.20V Color: Maroon (case/cover) Material: Polypropylene Mouth watering discounts on all products available in our website below ; - http://www.solarshopnigeria.com - http://www.buyright.biz Contact : Sir Frankie Smartcell global services 081-350-319-51 1 Like |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 1:08pm On Nov 24, 2017 |
[quote author=Chuckdee post=62641337 The bolded is soo wrong and misleading. Please how do you then explain how people in advanced countries like US and Europe that are on reliable grid that almost never goes down but have Solar setups without a single battery bank and yet make use of energy generated by those panels??... lets not BOLDLY mislead newbies that come to this thread to learn [/quote] ohh u can use solar panels without battery....pls explain o....what happens at night?...or the system is used in conuction with public power supply, wch kicks in when cloud covers the sn/at night? @niyiomo , pls this your soeur battery charger, am interested in it. can you confirm the specs, or where i can buy it? |
Re: Solar Energy, A Complement To FTA by Barezzi(m): 1:14pm On Nov 24, 2017 |
earthrealm:Grid-tie/true hybrid inverters 1 Like |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 1:57pm On Nov 24, 2017 |
[quote author=earthrealm post=62673133][/quote] Suoer smart battery charger which I also use is the 12v 50a blue color type... Works very well tho ! 1 Like
|
Re: Solar Energy, A Complement To FTA by makavele: 2:19pm On Nov 24, 2017 |
kiekie1: No be only suder . . . na suya !!! Bros, Suoer !!! 1 Like |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 3:22pm On Nov 24, 2017 |
makavele: Yes I wrote suoer initially but most call it suder ... Its all good. I displayed a visible pic of the Chinese battery charger above ! Cheers 1 Like |
Re: Solar Energy, A Complement To FTA by NoMoreTrolling: 8:19am On Nov 25, 2017 |
Selling my used Sukam 24v, 1.5kva inverter for 35k. Call 08171942851. Reason for sale, upgrade!!
|
(1) (2) (3) ... (311) (312) (313) (314) (315) (316) (317) ... (1855) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: Sammig1(m)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 70 |