Re: Solar Energy, A Complement To FTA by kiekie1(m): 6:04pm On Nov 27, 2017 |
makavele: Hello Sir, I believe its my personal post which dosnt really affect you in any way as anybody can quote a post on the thread .. Its not illegal ! So you can simply ignore instead of scouting for irrelevant issues. . Thanks 4 Likes |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 6:07pm On Nov 27, 2017 |
Hello house and fellow installers, contact me for your solar panels n other products at affordable prices. We also do payment on delivery. Solar panels Sunshine solar 300watts mono=58k 300watts poly = 55k 250watts mono=50k 250watts poly=46k 200watts mono - 42k 200watts poly - 37k 150watts mono - 29k 150watts poly - 27k Other products in stock includes Canadian solar, suntech, flames etc Inverters Felicity 3.5kva/24v( 35amps charging current) - 155k 5kva/48v ( 30amps charging current) - 185k 7.5kva 48v (40amps charging current) - 340k 10kva 48v- 390k Microtek 0.9kva/12v- 45k 1.1kva12v- 50k 1.6kva/24v- 70k 3.6kva/48v - 150k Other products includes sukam, vilpower, microtek, axpert etc Batteries (200ah) Quanta - 130k Long - 115k Okaya - 100k Gbm - 80k Other products in stock includes luminous, genus, monbat, toplight etc Call/watapp 08117398294 or email Info@monzpowersolutions.com You can also like our page on facebook.com/monzpowersolutions for beautiful installation pictures. |
Re: Solar Energy, A Complement To FTA by makavele: 6:51pm On Nov 27, 2017 |
kiekie1: You are forgiven, son !!! |
Re: Solar Energy, A Complement To FTA by Jamzig1(m): 7:19pm On Nov 27, 2017 |
pranil:Exactly what i meant by bypassed... A wired version would have worked best. Anyways, I'm just conducting research for future reference... I appreciate your input |
Re: Solar Energy, A Complement To FTA by Barezzi(m): 7:55pm On Nov 27, 2017 |
Makavele, u dey on fire today o... 3 Likes
|
Re: Solar Energy, A Complement To FTA by makavele: 7:57pm On Nov 27, 2017 |
Barezzi: My batteries are on float !!! 1 Like |
Re: Solar Energy, A Complement To FTA by bigrovar(m): 8:01pm On Nov 27, 2017 |
makavele:I consistently get above those figures on my ground mounted array made up of mismatch of different panels from MyHome to Solarland non a tier one provider 240w x2 + 250w x 2 connected in series parallel. With a combined functional output of 960w I consistently do over 750w to 810w on a clear sunny day between 11 and 1pm. I have seen occasional pick of 900w before too.. But standard generation is way north of 700w on sunny days. Part of the reason for this is because they are ground mounted and face true south at 81 degree vertical tilt. A 4500w system installed on a carport with clear view of the sky and installed flat yet picking at 2.5kw is not doing fine especially when total generation stuck at 6kwh.. My 0.96kw system does 4kwh on a regular. Before talk about load, remember he uses a high capacity battery drained to 50% dod that's a lot of kwh that need be replaced. Something ain't right. There are folks on here with 3kw array cranking out 10kwh daily, some of them even hit 2.8kw and have the log files to show for it. Proper real time minute by minutes log files. 2 Likes |
Re: Solar Energy, A Complement To FTA by bigrovar(m): 8:09pm On Nov 27, 2017 |
makavele: Let's watch how we talk to each other. Let's watch our language and explain our point with respect. You made a major goof about current flow between charger battery and load yet no one called you names we all took time to explain and correct your misconception. No one knows it all. The pride of this thread is that we manage to build a brotherhood, an oasis from the general ceaspet of insult and hate that NL can be. Let's maintain the decorum. 9 Likes |
Re: Solar Energy, A Complement To FTA by bigrovar(m): 8:14pm On Nov 27, 2017 |
pranil: Egbon pranil abeg drop me your mail or mail me at bigbrovar on Gmail I have some questions on Ipowerplus. The unit we have randomly throws up error 52 taking AC out offline until inverter is reset. This happens mostly during switch over from gen to NEPA but not always. If u have experience on such issues or about fixing those inverters drop it here so bad bad it can be filed into the knowledge bank |
Re: Solar Energy, A Complement To FTA by makavele: 8:14pm On Nov 27, 2017 |
bigrovar: 1stly . . i didn't even type the bolded at first; until something rather, somebody made me laugh so hard; i had to come back and type it . . I apologize 2ndly, that was no major goof; cos like pranil said and I stand with him; it depends on how the whole thing is wired. and like my other colleague said . . its' more of blind men feeling an elephant . . to each own his own interpretation . . . 3rdly, i have never claimed to be Mr Know it All or Mr Sell-it-All 4thly, The pride of this thread is that we put a stop to the 'asslicking' and "virtual genuflecting" and stick to knowledge distribution in a formal manner; as it is with other foreign RE forums And i take no pride in saying it; this thread was practically dead and heavily commercialized; and too familiarized ; until I came through with my tough controversy; which would definitely hurt some of y'all's pride . . . but at the end of the day, we all take 1 or 2 things home. . . Thankx 2 Likes |
Re: Solar Energy, A Complement To FTA by DUNKA(m): 8:33pm On Nov 27, 2017 |
GeorgeD1:wow. Wonder if any of our dealers here could try to import the Zenith batteries . I am sure it would sell well |
Re: Solar Energy, A Complement To FTA by Kove: 8:53pm On Nov 27, 2017 |
In the first place Voc and Isc should not be used to calculate the power output of solar panels. They are safety specifications, for the safety of the solar panels or your setup. So using them to calculate power output is misleading. Always use Vmp and Imp when making your calculations. 2. As rightly said by someone, the intensity of the sun matters 3. Most of the solar panels and charge controllers that come to Nigeria are overrated. The truth is they will hardly ever deliver up to 75% of their rated capacity. Eg if you buy a 3KVA stabiliser or generator, please don't use it to power more than 2KVA equipment or 1.5kW if you no want make e spoil 4. Lest I forget, if you want to measure actual power being delivered to your house, please use a multimeter and measure at the point between charge controller and panels when the batteries are empty and just started charging(and not when they are already getting full because the batteries will not draw maximum power when they are getting full and you might not be able to tell the real power capacity of your panels) So to answer your question at rated illumination of 1000W/m2, please hope for 75% max power. If you get 75% with equipment bought in 9ja, guy you don hammer. 80% and above, hmmm, no comments but e go hard, real hard. And don't rely on peak power always average over some minutes even if it is 3 - 5 minutes 1 Like |
Re: Solar Energy, A Complement To FTA by olagunju2000: 9:34pm On Nov 27, 2017 |
[img][/im
|
Re: Solar Energy, A Complement To FTA by olagunju2000: 9:35pm On Nov 27, 2017 |
[img][/img]
|
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 9:39pm On Nov 27, 2017 |
I have been following the intensity of today's posts with keen interest and I must say I echo you BigRovar! My MorningStar TS-MPPT 60A is connected to a 4.5kw (15 × 300 Mono Panels) array just like Mr Olagunju - my yield today was 17.77kwh in Lekki. Lagos State and this was an average day with quite a few cloudy intervals. This underscores the importance of a solid charge controller as I routinely do 21kwh daily yield on a good day when my batteries are deeply drained. Please bear the following in mind - my panels are West facing at a ~30° slope so by no means ideal yet I get these results with a solid charge controller - I made custom settings to throttle my controller max charging amps to 55amps - it will routinely hold 54.4amps from 1pm to 4:30pm with only brief rests at 40sumtn amps when there is a lot of cloudy skies. When I had my chinco EP Solar on this same 4.5kw array I would get say 45 amps very briefly as peak but EP Solar would generally stay around 39amps - the only thing different between 39amps & 54amps yield is a solid MPPT charge controller!!! - 15amps improvement and remember I am throttling the morningstar controller output to 55amps via custom settings so as not to boil my batteries - I have seen it easily hold 58.sumtn amps steady for 3 hours plus. So that's it - Mr Olagunju probably needs a proper charge controller if everything else checks out - currently I disconnected my second array of 1.8kw which is connected to the EP Solar - I am keeping it as backup for when the rainy/cloudy season comes. bigrovar:
|
Re: Solar Energy, A Complement To FTA by olagunju2000: 9:40pm On Nov 27, 2017 |
[img][/img
|
Re: Solar Energy, A Complement To FTA by olagunju2000: 9:42pm On Nov 27, 2017 |
[img][/img]
|
Re: Solar Energy, A Complement To FTA by olagunju2000: 9:51pm On Nov 27, 2017 |
NiyiOmoIyunade:Thanks, i hear you loud and clear. Unfortunately i bought the chinco one myself. No blame to the installer. I will arrange for another one |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 10:27pm On Nov 27, 2017 |
Many thanks Mr Olagunju and you are welcome too. With the pictures you have shared most of the house would say your installer could have done a neater job with the wiring cleanup especially with the changeovers/knife-switches inside the house but this is just aesthetics in the end I also observed that he did not use the modular MC3/4 connectors to connect the panels in series and then parallel - to my eye the way he spliced the panels' positive and negative cables to the main trunk lines may not make for a firm mechanical connection - just something to check - if you could isolate each series string of panels and see what they are doing with a volt and amp meter and see if any string is doing much worse or lower than the others - further in the evening or after disconnecting panels from CC, try pulling the spliced wires apart - they should give no 'play' whatsoever i.e shouldn't feel loose. The good news is that panel heating up and reducing output should not be a big issue in your scenario - you will also enjoy a cool shade under the panels in the afternoons. I think you are pretty close to getting to a good place with your system - with a few wiring tweaks and a solid charge controller you should soon be smiling and reaping the benefits of your system. One last thing is to check if your batteries are behaving close to spec i.e 48v 600ah - do you have access to a battery monitor? or you can just run a known wattage load for x hours and see how the batteries hold up - it may be that your batteries are lightly cycled given such a huge bank and the CC is just floating most of the day - but again in the pictures I saw the battery voltage at between 48.sumtn & 49.sumtn which is not a good sign so early in the night as it means they were not fully charged during the day or have been quickly depleted after sundown. Are you simultaneously charging with PHCN or Generator during the solar charging hours? Is the surface of the panels clean and relatively dust free (if not wash them). Is the house or other object overshadowing the carport and shading the panels? Just looking for what random factors could be limiting your yield olagunju2000: 1 Like |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 10:27pm On Nov 27, 2017 |
Barezzi: No b smal tin, the Baba jst dey para lol |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 10:31pm On Nov 27, 2017 |
NiyiOmoIyunade: What u r trying to say is better soup na moni kill am. |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 10:33pm On Nov 27, 2017 |
NiyiOmoIyunade: Neat and sexy installation is our specialty , the house can check our Facebook page for reference. facebook.com/monzpowersolutions |
Re: Solar Energy, A Complement To FTA by olagunju2000: 10:54pm On Nov 27, 2017 |
Thanks NiyiOmoIyunade:Thanks a lot. There was no load this afternoon because the battery was drained to 45% this morning. We charge the battery all the day and was not in use when i took the picture. Please what model is your morning star? Thanks |
Re: Solar Energy, A Complement To FTA by DMerciful(m): 11:12pm On Nov 27, 2017 |
I have gotten 802w out of 1000w installation..... Sunshine panels for that matter makavele: |
Re: Solar Energy, A Complement To FTA by DMerciful(m): 11:41pm On Nov 27, 2017 |
Different brands of mppt works besbt at different Voc. Epsolar 60A works best around 120V input while fangpusun works best around 60V for a 24v battery system . In summary...do the research for d right input.... Almost all mppt are 97% and above efficient NiyiOmoIyunade: |
Re: Solar Energy, A Complement To FTA by abunafiu(m): 12:11am On Nov 28, 2017 |
You guys made my day. It's been a while since the thread experienced EQUALISATION VOLTAGE. Abeg make una drop to float voltage Abeg. @Bigrovar, you did well as an unbiased umpire. Me Niyi, thanks for stressing the importance of premium mppts. I have a 4kw set up with classic 150 Mppt. I usually harvest above 9kw when by batteries are hungry. My peak performance has been 2800 to 3000w. But on cool days, I record up-to 4kw plus and never last for over 1 minute. It's just a flash. Ilorin Sun is been kind to us for the past 4 days. Afternoon cooking resumed. All extra energy has to be used up. 2 Likes |
Re: Solar Energy, A Complement To FTA by Dam5reey(m): 12:21am On Nov 28, 2017 |
abunafiu: This another confirmation @ makavele more than 6 confirms Argument closed.. Now I know where to check sun intensity... People should stop using Chinco products performance to make conclusions.. If a US brand make a product 1.2kw they will rate it to 1kw But Chinco will rate a 500w products to be 1kw... I will just save more to get Victron charge controller jejeli |
Re: Solar Energy, A Complement To FTA by abunafiu(m): 12:23am On Nov 28, 2017 |
I just realised I have been off grid for almost 18 months. My Trojan T105 are still giving me the desired result. But I ensure I never drain below 47.5V. I am not sure I am ready to find out the consequences of doing so. Since the batteries respect me, I equally respect them by ensuring NO DEEP DISCHARGE and regular equalisation charge. I maintained an float voltage of 56v which Is to ensure I have full battery for as long as I have quality Sun. I am aware of the effect on watering but that's the only way I get the best from them. Myself and Saipro discovered this method and has been working for us. My Trojans are now 3.5 years old. Purchased June 2014. I pray the price of batteries drop. I am not sure I can afford replacing my battery bank with the current prices. 1 Like |
Re: Solar Energy, A Complement To FTA by abunafiu(m): 12:26am On Nov 28, 2017 |
Dam5reey: Agreed. Thanks to George D who opened our eyes several years ago on the importance of premium charge controllers. |
Re: Solar Energy, A Complement To FTA by makavele: 12:30am On Nov 28, 2017 |
Dam5reey: You nor see "It's just a flash" for there abi . . eyes dey pain you man If i tear you something . . . 1 Like |
Re: Solar Energy, A Complement To FTA by makavele: 12:34am On Nov 28, 2017 |
Kove: A man who knows his onions !!!! 2 Likes |
(1) (2) (3) ... (315) (316) (317) (318) (319) (320) (321) ... (1855) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: HeavenlyBang(m), Jefferyzz(m)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 121 |