Re: Solar Energy, A Complement To FTA by pranil(m): 11:43am On Apr 01, 2018 |
mank1234:It will not unless you also have a Battery inverter like Victron or sunny island to support it with the simulated grid . It is quite complicated, costly and potentially dangerous so best to be avoided for first time setup known industrial combinations which are slightly easier to set up and available in Nigeria SMA sunny island, and Sunny Boy Victron Multi/Quattro and Fronius Magnum and APssystms ( also branded by Magnum for their own use) 3 Likes |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 1:58pm On Apr 01, 2018 |
The HA02 literature clearly states 'wiring sequence' whether series or parallel does not matter. In your scenario just connect each pair of wires to each battery in your bank and you will be fine - I prefer the HA02 with four pairs of wires over the HA01 because it can move more current between batteries per unit of time. Apart from what the manual says, I can also add practical experience that I have used it in just such a way on two occasions now and it has been working with no issues and mind you I have meters with resolutions down to DC MilliAmps to verify correct operation. The big NO NO is that you must never bridge any of the contacts of the HA02 with another one hence they ship with each wire terminal ring sheathed in a plastic tube for insulation. On a lighter note, NL folks are ordering the thing on Amazon like crazy and making it go out of stock always. Abeg stop am!!! earthrealm: 2 Likes
|
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 2:42pm On Apr 01, 2018 |
Yes the Canadian Solar panels are firing better indeed. The Flames are not doing bad at all either for a Tier 2 panel with 2 years on the roof. The reason why the Canadian Solar makes sense for me now is because I was able to get them at a super bargain price from Gennex Tech.... else if they came at a premium like sellers on here advertise for Solar World and Canadian Solar then the extra performance would have already been priced and even over priced into the purchase price hence would not have made financial sense. That said the Gennex Canadian Solar have impressed me so much that I want to get 1kw more to add to my array - although I don't need it now, adding 3 more 330w panels will complete all my present and possible future needs as I move from 6.6kw to 7.6kw PV array I am struggling hard to resist the temptation and Zeestone has preached endlessly to me to not go ahead but I fear I will succumb to the temptation soon ... I have all your suggestions already in place for the MorningStars except for the separate voltage sense cables. From what I remember MorningStar said it was okay to parallel the voltage sense cables but I will give separate cables a chance again and revert with the outcome. mank1234: 1 Like |
Re: Solar Energy, A Complement To FTA by sinistrian(m): 4:06pm On Apr 01, 2018 |
NiyiOmoIyunade:Thanks for this Niyi. While trying to get m monitoring software to read this data, i discovered there's an API over the network cable that can give me much more info . Documentation is here: http://www.morningstarcorp.com/wp-content/uploads/2014/02/TSMPPT.APP_.Modbus.EN_.10.2.pdf The api (for the programmers here) can be called via a regular web request to http://tsmppt<your serial>/MBCSV.cgi?ID=1&F=4&AHI=0&ALO=0&RHI=0&RLO=80 |
Re: Solar Energy, A Complement To FTA by sinistrian(m): 4:27pm On Apr 01, 2018 |
mank1234:Currently 1.8KW but I'm adding another 900W when I sort out where to put them 1 Like |
Re: Solar Energy, A Complement To FTA by davodyguy: 5:03pm On Apr 01, 2018 |
NiyiOmoIyunade: That's my company you know? When you mentioned Canada, I waited to read the Name of Company and I'm happy you mentioned Gennex. 1 Like |
Re: Solar Energy, A Complement To FTA by babaegun(m): 5:04pm On Apr 01, 2018 |
NiyiOmoIyunade: @NiyiOmoIyunade Hello, How did you connect your pv arrays? Is it 2 in series or 3 in series before the parallel connection? Also, whats the cumulative/expected PV Volt/Amp that is feeding your charge Controllers? Thanks. |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 6:11pm On Apr 01, 2018 |
I run a 48v nominal battery system. So my panels are connected 3 in series. babaegun: |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 6:12pm On Apr 01, 2018 |
Yes boss! davodyguy: |
Re: Solar Energy, A Complement To FTA by davodyguy: 6:15pm On Apr 01, 2018 |
Hello my people. (NiyiOmoIyunade) I got the attached 125amps CB. I'm wondering where I should put it. 1. Between Panels and CC or 2. Between CC and 2*200Ah batteries? Panels are 270 watts *3 plus 250 watts= 1060 watts CC= 40A E-Smart Regards
|
Re: Solar Energy, A Complement To FTA by mank1234(m): 6:41pm On Apr 01, 2018 |
NiyiOmoIyunade: 330W * 3 in series? Is it not too close to the CC limit of 150V? What's the panel's Voc? 1 Like |
Re: Solar Energy, A Complement To FTA by babaegun(m): 6:42pm On Apr 01, 2018 |
NiyiOmoIyunade: With that, I suspect you have 135.9V & 35.04A as cumulative feeding your CC (for the 12 pv panels) right? |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 7:02pm On Apr 01, 2018 |
VmP 37.5v × 3 = 112.5v VoC 45.9 × 3 = 137.7v Bear in mind these two parameters are at 25°C STC temperatures and actual voltage will derate based on a known temperature coefficient for our ambient weather here in Lagos around 28°C to 35°C Regardless, these are both within the tolerance for the MorningStar. There is a derating algorithm designed into the MorningStar where if the VmP gets into the 125v range it throws a fault code 'High Array Voltage Current Limiting' and throttles back on things to keep everything within tolerance. See below nameplate of the Canadian Solar 330w as well as my max array voltage over several days. mank1234: 2 Likes
|
Re: Solar Energy, A Complement To FTA by babaegun(m): 7:14pm On Apr 01, 2018 |
mank1234: No. As per voltage, he is fine. 1 Like
|
Re: Solar Energy, A Complement To FTA by babaegun(m): 7:19pm On Apr 01, 2018 |
NiyiOmoIyunade: I just love the Graphing functionality of the MorningStar. It is similar to Midnight Classic. Anytime I have the opportunity to change my CC, I will surely choose one of those marvelous CCs. 1 Like |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 8:31pm On Apr 01, 2018 |
NiyiOmoIyunade: Yeah..saw it has risen to 72 usd on amazon..still 50 usd on aliexpress..i ordered sharply from aliexpress..22usd is worth the extra 2wks wait Food u clarified..tot so too..but wanted to be sure..or someone with hands on experi3nce to comment..as mine is still on the north china sea |
Re: Solar Energy, A Complement To FTA by efuro(m): 9:21pm On Apr 01, 2018 |
Oga Niyi Thank you for your good work so far. Am surprised the glorified Canadian solar panels are assembled in China also and may be under similar conditions as 2nd tier ones. That really makes me question their huge price tags or am I missing something? NiyiOmoIyunade: 3 Likes |
Re: Solar Energy, A Complement To FTA by davodyguy: 9:50pm On Apr 01, 2018 |
efuro:Yes, but to Canadian Specs, not to African specs. China builds for UAE and USA as well, but the gradings are quite different. Same with Gennex batteries too. I'm using them at home With over 1 billion human beings in China, Labour is very cheap. Recall Trump says China should start manufacturing in the US, same with Toyota and other conglomerates. 2 Likes |
Re: Solar Energy, A Complement To FTA by babaegun(m): 11:10am On Apr 02, 2018 |
nonoski: @Nonoski Hi, How was the upgrade/installation? Do share the good news with us here. |
Re: Solar Energy, A Complement To FTA by Barezzi(m): 12:52pm On Apr 02, 2018 |
NDM1-125: is the model number of your mcb. C100: is it's current/curve rating. 230v: is it's operating voltage. In summary, it's a 100A mcb for use in single phase AC applications. davodyguy: |
Re: Solar Energy, A Complement To FTA by Barezzi(m): 12:52pm On Apr 02, 2018 |
. |
Re: Solar Energy, A Complement To FTA by davodyguy: 12:55pm On Apr 02, 2018 |
Barezzi:Thanks so its between CC and Panels? |
Re: Solar Energy, A Complement To FTA by Barezzi(m): 12:59pm On Apr 02, 2018 |
No, there's only DC between PV array and CC. You can install it between your inverter and DB, provided it's single phase. davodyguy: |
Re: Solar Energy, A Complement To FTA by davodyguy: 1:03pm On Apr 02, 2018 |
Barezzi: What I intend getting is a breaker to protect my CC from thunder or Surge. With you're implying, this can't do it |
Re: Solar Energy, A Complement To FTA by pranil(m): 1:41pm On Apr 02, 2018 |
davodyguy: Please do not use AC breaker in DC applications their designs are different. AN AC breaker uses the zero crossing of AC to extinguish arc while interrupting a current. For DC breaker it used electromagnets. using AC breaker in DC applications is a fire hazard the following video is very instructive https://www.youtube.com/watch?v=Cup5fMGaE2g https://www.youtube.com/watch?v=S0diAeysxVo https://www.youtube.com/watch?v=csMQ9A-4Pws There are many suppliers here on Nairaland. You can ask for 50 Amp or 63 AMP DC breaker (nonpolarized preferred for beginners) 3 Likes |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 1:44pm On Apr 02, 2018 |
No boss. Ogas Barezzi and Pranil have said it all. You cannot use an MCB to protect equipment - they exist to protect your wiring from overcurrent situations that could cause the wires to run hot, melt the insulation and cause a fire. They also reinforced that this particular MCB you had in the picture is not even DC rated hence unsuitable for use anywhere between your panels and batteries. To protect from lightening do the following. 1) Install an external earthing/grounding point in your premises - connect the earth/ground side of all your AC equipment, earth/ground point (terminal or chassis) of CC and panels and negative post of batteries or battery bus bar (if paranoid) to this common building earth/ground point. 2) Install a lightening arrestor on your roof and connect this also to the common external ground/earth point for your premises 3) Optionally, Install a surge arrestor e.g the Midnite MNSPD 300 to further protect AC and DC components. Midnite has different ones for each application. The common earth point in your premises will provide a safe path for all surge currents to be diverted to the ground. The lightening arrestor on your roof represents an 'attractive spot' for lightening to hit and from there be diverted safely to ground. NEC code is to have only one external earth/ground point per premises to prevent surge current arcing between earth/ground points and electrocuting people in between the current flow path. davodyguy: 4 Likes |
Re: Solar Energy, A Complement To FTA by davodyguy: 2:05pm On Apr 02, 2018 |
NiyiOmoIyunade:Thanks. Yoruba people say 'Aa bere ona, kii sina' If you ask for the way, you can't miss your way 3 Likes |
Re: Solar Energy, A Complement To FTA by davodyguy: 2:06pm On Apr 02, 2018 |
pranil:Thanks. Would do as advised |
Re: Solar Energy, A Complement To FTA by Jamzig1(m): 2:09pm On Apr 02, 2018 |
NiyiOmoIyunade:If proper grounding/earthing is in place, there should be no need for MNSPD right? |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 2:28pm On Apr 02, 2018 |
Well ...... there should not ..... But I think if you are paranoid, or want to go overboard with your protections.... Please let me defer to core power experts like Oga Pranil to talk about this one please - whether or not one still needs an SPD given sufficient earthing/grounding in place. Jamzig1: |
Re: Solar Energy, A Complement To FTA by davodyguy: 2:31pm On Apr 02, 2018 |
NiyiOmoIyunade:Is it General? No no sunshine in my area since Wednesday. What's going on? |
Re: Solar Energy, A Complement To FTA by sinistrian(m): 3:04pm On Apr 02, 2018 |
Very little sunshine here too. I was waiting to boast of the stats generated by my morningstar Anyway, the only thing i can say for now is that the MPPT sweep is very very fast - like once a minute, you wont even notice it. No more starting from zero like the Fangpusun 150/70. |
(1) (2) (3) ... (378) (379) (380) (381) (382) (383) (384) ... (1821) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: 1 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 84 |