Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 5:13pm On Apr 27, 2018
I would go with the Fangpusun Blue Solar/Victron clone on the basis of 'MPPT Tracking Efficiency' - I have bench marked the charging current output of this CC vs EP Solar and it is far superior in tracking ability and total power harvested.

Also I am not aware of any limitations or quirks of that specific Fangpusun unit that makes it prefer 2 panels in series to 3 panels in series for a 48v system. Based on my observations, the unit clamps the array voltage lower than what the MorningStar for example would work with and I believe this is why MorningStar can produce about 10 to 15% more power over the course of one day given thesame operating conditions.

Perhaps this preference for 2 panels in series vs 3 is on the Fangpusun Outback/Midnite type clones but I have no experience with those units.


lexi28:
hi house. I have a question
there are 6 no's 300w panels.(imp :8.24amp, Vmp : 36.7v, VOC: 44.06v) and two MPPT controllers available. system is to run on 48v. according to gleanings from the forum:

fangpusun prefers 2s*3p : total string current : 8.24*3= 24.72a

TriStar/epever prefer 3s*2p: total string current:16.48a

which will offer more MPPT Current under the same light conditions?

Mr Niyi
George D.
kiekie,
makavele
Oga Chris
JUO
anyone who has tried it the comparison, kindly advise
Thanks!!

1 Like

Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 5:17pm On Apr 27, 2018
I think it's just a personal touch/signature na grin

Much like how the mavens of the foreign RE/Solar online forums sign-off their posts e.g.

BB
vtMaps


davodyguy:


You and this your P34c3

1 Like

Re: Solar Energy, A Complement To FTA by makavele: 8:03pm On Apr 27, 2018
lexi28:


Sir, can you give steps how to locate the temperature sensor and relocate it? thanks

Wrong mention; I didn't do a temperature sensor hack; I use a DC fan . . .

Open the inverter and take a snapshot. Post here; we will point it out to you

1 Like

Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 8:20pm On Apr 27, 2018
This question should be for Oga DMerciful. It was he who pioneered the hack.

CC DMerciful



lexi28:


Sir, can you give steps how to locate the temperature sensor and relocate it? thanks

1 Like

Re: Solar Energy, A Complement To FTA by makavele: 9:02pm On Apr 27, 2018
NiyiOmoIyunade:
This question should be for Oga DMerciful. It was he who pioneered the hack.

CC DMerciful




And patented it, I guess !!! grin grin grin

2 Likes

Re: Solar Energy, A Complement To FTA by lexi28(m): 12:34am On Apr 28, 2018
makavele:


Wrong mention; I didn't do a temperature sensor hack; I use a DC fan . . .

Open the inverter and take a snapshot. Post here; we will point it out to you

Oh, thanks. I'll do so.
Re: Solar Energy, A Complement To FTA by kiekie1(m): 7:49am On Apr 28, 2018
HURRY! DISCOUNTED PRICES !!!

Canadian solar panels 330w mono ... N70,000
Bulk purchase ..... N69,000

Contact:
Smartcell global services
081-350-31951

2 Likes

Re: Solar Energy, A Complement To FTA by kiekie1(m): 7:58am On Apr 28, 2018
DISCOUNTED PRICES !!!

SUNSHINE SOLAR PANELS !!
250w mono. N42,000
200w mono. N35,000
150w mono. N27,000
300w poly. N47,000
280w poly. N45,000
260w poly. N40,000
250w poly. N38,000
200w poly. N32,000
150w poly. N26,000
130w poly. N23,000

Joysolar panels :

poly:80watt#15000/90watt#17000/180watt 24v #32000

Mono:80watt#17000/100w#19000/150watt#25000/200watt#35000
12/24v 10A Phocos 15500
12/24v 20Aphocos controller 18000
48v 45a pwm phocos controller #70,000
48v 80a pwm phocos controller #95,000


320w Joysolar poly-55k
300w myhome mono-55k
260w Joysolar mono-46k
250w S.V mono-45k
200w S.V mono-37k
150w YahSun mono- 32k
150w Myhome mono- 30k
150w YahSun poly- 28k
100w YahSun Mono- 23k
100w YahSun poly- 21k

Yachi 260 & 310w mono offloading soon

Contact:
Smartcell global services
081-350-31951

1 Like

Re: Solar Energy, A Complement To FTA by kiekie1(m): 8:01am On Apr 28, 2018
HURRY ! DiSCOUNTED PRICES !!!
CANADIAN 340w Mono panels
340w. N
Solar world 325w mono panels. Made in Germany
..N84,000 (9 units in bulk)
Must Powerstar inverters (VIL series)
1000w 12v. N85,000
1500w 12v. N95,000
2000w 12v N110,000
3000w 24v. N160,000
4000w 48v. N220,000
5000w 48v. N250,000
6000w 48v. N280,000
10000w 48v. N700,000
10000w 48v HYBRID. N800,000
EP ever 40a 12-24v mppt with MT50 ...N
EP Solar (i-tracer) 60amps mppt..... ....... N128,000
Pro solar roof mount set .....N33,000
UNI-T DC/AC true RMS clamp meter.....N22,000
DC voltage led meter .........N4,000
Prag products; 10-150kva (45-270vac input) servo or relay stabilizers
Discounts on all our Prag product online prices
DC breakers 10-63a ....N3-4k
DC breakers 63a double pole....... N7k
USA trojan battery 12v 200a (J200RE) -N130,000 "quantity above 1"
USA trojan battery 12v 205a (AGM) -N......
If you are for AGM SMF batteries :
-kung Long battery 12v 200a N120,000
-Quanta Amaron 12v 200a N125,000
-Mercury 12v 200a N98,000
NOTE: USA trojan sealed agm 6v 315a (L16) battery is now in stock ....... N150,000
Mouth watering discounts on;
-Solarshop Nig products
-Prag products
-Back2back distribution partners
-Luminous products
-Voltron inverters etc
CALL US NOW:
Smartcell global services
Order now 081-350-31951

1 Like

Re: Solar Energy, A Complement To FTA by kiekie1(m): 8:03am On Apr 28, 2018
abunafiu:
Make una folllow me analyse this. Fridge, iron join others.

People need to wise up not to fall into wrong hands.

Hmmn this is really funny smiley .. Nothing good comes easy! You said it all Bro !!

1 Like

Re: Solar Energy, A Complement To FTA by kiekie1(m): 8:08am On Apr 28, 2018
lexi28:
hi house. I have a question
there are 6 no's 300w panels.(imp :8.24amp, Vmp : 36.7v, VOC: 44.06v) and two MPPT controllers available. system is to run on 48v. according to gleanings from the forum:

fangpusun prefers 2s*3p : total string current : 8.24*3= 24.72a

TriStar/epever prefer 3s*2p: total string current:16.48a

which will offer more MPPT Current under the same light conditions?

Mr Niyi
George D.
kiekie,
makavele
Oga Chris
JUO
anyone who has tried it the comparison, kindly advise
Thanks!!

Hello, the both controllers are good but also have their flaws. I have used the ep solar "a tracer series" and worked good for me without issues . I still use the ep solar "I tracer version" and it is still firing like new wink.. It depends on your choice as both works pending on your configuration and system voltage !

Note: it's easy to fix a defective / faulty ep solar mppt as I have helped a lot of friends in repairs . Cheer's

4 Likes 2 Shares

Re: Solar Energy, A Complement To FTA by Saipro(m): 10:36am On Apr 28, 2018
makavele:


Will send a link for one as soon as I can get on a computer. They don’t even use up to 5 W and are brushless

Eagerly anticpating your link(s)
Re: Solar Energy, A Complement To FTA by efuro(m): 10:47am On Apr 28, 2018
For those desirous of low power A/C (305w) check out this link :


https://www.youtube.com/watch?v=uF_H85aS55o

Maybe marketers here can begin it's importation.
Re: Solar Energy, A Complement To FTA by DMerciful(m): 11:13am On Apr 28, 2018
lexi28

Here is how to resolve the excessive mustpower series temperature issue by changing the position of the temperature sensor so the fan comes on at 40 degrees vs 65degrees.
step 1: Locate the temperature sensor on the heat sink(first picture)
step 2:Increase the length of the temperature sensor wire by adding additional wires so it can reach the transformer
step 3:Loose one nut of the transformer lamination holder and use a big washer to fix the temperature sensor to the transformer as shown(third picture)

whatsapp me for further clarification(see my signature)
NiyiOmoIyunade:
This question should be for Oga DMerciful. It was he who pioneered the hack.

CC DMerciful



2 Likes 1 Share

Re: Solar Energy, A Complement To FTA by makavele: 1:30pm On Apr 28, 2018
Good read:

Re: Solar Energy, A Complement To FTA by mcTrinity(m): 8:32pm On Apr 28, 2018
Good evening house,

I'm trying to improvise a PV combiner box using 4 circuit breakers and breaker box.

Attached is a sketch of how the connection will look like.

The PV combiner box is for 16# of 325w panels (4X4 configuration)

The circuit breakers located in the breaker box will be rated 16A (DC) or 32A (AC)

Correction is strictly welcomed...

Thanks

Re: Solar Energy, A Complement To FTA by abunafiu2: 10:34pm On Apr 28, 2018
mcTrinity:
Good evening house,

I'm trying to improvise a PV combiner box using 4 circuit breakers and breaker box.

Attached is a sketch of how the connection will look like.

The PV combiner box is for 16# of 325w panels (4X4 configuration)

The circuit breakers located in the breaker box will be rated 16A (DC) or 32A (AC)

Correction is strictly welcomed...

Thanks

the improvised design is going to work. I have personally used it on several occasions. (I didn't have the patience of waiting to see the attached picture cos of poor network here).
my worry now is the issue of 4 by 4 configuration. kindly inform us the type of Mppt controller ure using.
I pray it's the classic such that you enable the hyper voc function to protect it from once in a while 150v ➕ voc during cool weather.
Re: Solar Energy, A Complement To FTA by Barezzi(m): 11:48pm On Apr 28, 2018
Add a surge protection device.
4S4P? I'm sure you've done your homework.

For up to 250v voc, consider the Victron Energy Smartsolar 250/100 CC.

Re: Solar Energy, A Complement To FTA by mcTrinity(m): 6:05am On Apr 29, 2018
abunafiu2:


the improvised design is going to work. I have personally used it on several occasions. (I didn't have the patience of waiting to see the attached picture cos of poor network here).
my worry now is the issue of 4 by 4 configuration. kindly inform us the type of Mppt controller ure using.
I pray it's the classic such that you enable the hyper voc function to protect it from once in a while 150v ➕ voc during cool weather.
abunafiu2:


the improvised design is going to work. I have personally used it on several occasions. (I didn't have the patience of waiting to see the attached picture cos of poor network here).
my worry now is the issue of 4 by 4 configuration. kindly inform us the type of Mppt controller ure using.
I pray it's the classic such that you enable the hyper voc function to protect it from once in a while 150v ➕ voc during cool weather.
abunafiu2:


the improvised design is going to work. I have personally used it on several occasions. (I didn't have the patience of waiting to see the attached picture cos of poor network here).
my worry now is the issue of 4 by 4 configuration. kindly inform us the type of Mppt controller ure using.
I pray it's the classic such that you enable the hyper voc function to protect it from once in a while 150v ➕ voc during cool weather.

The SCC is PT-100

Thanks
Re: Solar Energy, A Complement To FTA by mcTrinity(m): 6:06am On Apr 29, 2018
Barezzi:
Add a surge protection device.
4S4P? I'm sure you've done your homework.

For up to 250v voc, consider the Victron Energy Smartsolar 250/100 CC.

The SCC is PT-100. The high Voc range is 188-240 VDC @48V

Thanks
Cheers
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 6:10am On Apr 29, 2018
No reason why it would not work - the diagram attached looks more like you are using two separate combiner boxes though - one for the positive side of the string and the other for the negative side or perhaps it is one huge box.

For me breaking the positive connection and using a common bar for all the neutral connections is sufficient although one may argue there is still some voltage potential on the negative side when you trip the positive breaker.

You really do not want to use an AC rated breaker in a DC application no matter how oversized the AC breaker is relative to the DC load - while it may work you just never know when the breaker will fail to extinguish the DC arc and cause a fire.

The 4 panels in series comment jumped out at everyone - be sure to know that your CC can safely handle the high voltage as DC overvoltage is the quickest way to destroy a CC - my MorningStar CC fairly often throws the 'High Array Voltage, Current Limiting' alarm which means panel VoC went above the 115/125vdc range and this is on a 3 panels in series string using 330w panels.



abunafiu2:


the improvised design is going to work. I have personally used it on several occasions. (I didn't have the patience of waiting to see the attached picture cos of poor network here).
my worry now is the issue of 4 by 4 configuration. kindly inform us the type of Mppt controller ure using.
I pray it's the classic such that you enable the hyper voc function to protect it from once in a while 150v ➕ voc during cool weather.

mcTrinity:
Good evening house,

I'm trying to improvise a PV combiner box using 4 circuit breakers and breaker box.

Attached is a sketch of how the connection will look like.

The PV combiner box is for 16# of 325w panels (4X4 configuration)

The circuit breakers located in the breaker box will be rated 16A (DC) or 32A (AC)

Correction is strictly welcomed...

Thanks
Re: Solar Energy, A Complement To FTA by mcTrinity(m): 6:17am On Apr 29, 2018
NiyiOmoIyunade:
No reason why it would not work - the diagram attached looks more like you are using two separate combiner boxes though - one for the positive side of the string and the other for the negative side or perhaps it is one huge box.

For me breaking the positive connection and using a common bar for all the neutral connections is sufficient although one may argue there is still some voltage potential on the negative side when you trip the positive breaker.

You really do not want to use an AC rated breaker in a DC application no matter how oversized the AC breaker is relative to the DC load - while it may work you just never know when the breaker will fail to extinguish the DC arc and cause a fire.

The 4 panels in series comment jumped out at everyone - be sure to know that your CC can safely handle the high voltage as DC overvoltage is the quickest way to destroy a CC - my MorningStar CC fairly often throws the 'High Array Voltage, Current Limiting' alarm which means panel VoC went above the 115/125vdc range and this is on a 3 panels in series string using 330w panels.






Thanks Niyi

it's two separate breaker box. one for the circuit breakers and for the neutral bar

thanks for the advice on the DC/AC breaker selection...

The CC is PT-100 and has a higher Voc range of 188-240VDC.

The lower range (Vmp, not even Voc) is 73 VDC, at which the CC won't work. with 3 in series, the Vmp might be hitting the lower range

Thanks bro

Re: Solar Energy, A Complement To FTA by S007: 8:22am On Apr 29, 2018
mcTrinity:
Good evening house,

I'm trying to improvise a PV combiner box using 4 circuit breakers and breaker box.

Attached is a sketch of how the connection will look like.

The PV combiner box is for 16# of 325w panels (4X4 configuration)

The circuit breakers located in the breaker box will be rated 16A (DC) or 32A (AC)

Correction is strictly welcomed...

Thanks

I have 16, 340W Canadian solar panels on a PT100 in a 4S4P configuration.
I have never hit the high Voc range starting at 187V. The most I have seen is 172V.
4X4 configuration will definitely work. My CC wakes up very early in the morning - Sometimes before 7am. It works on cloudy days and sometimes rain.
For PT100, 4X4 is a good way to go.

4 Likes

Re: Solar Energy, A Complement To FTA by S007: 8:24am On Apr 29, 2018
mcTrinity:
Good evening house,

I'm trying to improvise a PV combiner box using 4 circuit breakers and breaker box.

Attached is a sketch of how the connection will look like.

The PV combiner box is for 16# of 325w panels (4X4 configuration)

The circuit breakers located in the breaker box will be rated 16A (DC) or 32A (AC)

Correction is strictly welcomed...

Thanks


I have 16, 340W Canadian solar panels on a PT100 in a 4S4P configuration.
I have never hit the high Voc range starting at 187V. The most I have seen is 172V.
4X4 configuration will definitely work. My CC wakes up very early in the morning - Sometimes before 7am. It works on cloudy days and sometimes rain.
For PT100, 4X4 is a good way to go.
Re: Solar Energy, A Complement To FTA by BRIGHTSOLAR(m): 10:00am On Apr 29, 2018
DROPSHIPPING AND ONLINE DELIVERY OF RENEWABLE ENERGY MATERIALS




INVERTER

MICROTECH INVERTER
900VA,12V N46,000
1.1KVA,12V N53,000
1.6KVA/24V N72,000
2KVA/24V N80,000
2.6KVA/36V N105,000
3.6KVA/48V N170,000
5.2KVA/48V N340,000.
5.5KVA/96V N340,000
10KVA/180V N790,000


THREESIXTY INVERTER

1.1KVA,12V N53,000
2KVA/24V N80,000
5KVA/96V N350,000

KELVIN INVERTER

2.5KVA/36V N125,000
2.5KVA/48V N125,000
3 KVA/48V N170,000
5KVA/48V N340,000.
5KVA/96V N290,000
7.5KVA/120V N550,000
10KVA/180V N750,000



MUST POWER STAR INVERTER

4kva 3000W 24V N 220,000
4kva 3000W 48V N 260,000
5kva 4000W 48V N 350,000
6kva 5000W 48V N 400,000
7.5kva 6000W 48V N 450,000





HYBRID INVERTER
VOLTRON SERIES
1.4KVA/12(30A N65,000
2.4KVA/24V50A N97,000
3KVA /48V 60A MPPT N220,000
5KVA /48V 60A MPPT N310,000
7.5KVA /48V 60A MPPT N430,000
10KVA /48V 100A MPPT N750,000
15KVA /48V 60A MPPT N850,000
15KVA /48V 120A MPPT N890,000



BATTERY

LONG BATTERY
LONG BATTERY 12V/100AH N 67,000
LONG BATTERY 12V/150AH N 100,000
LONG BATTERY 12V/200AH N 120,000

MONBAT SLIM BATTERY
MONBAT BATTERY 12V/100AH N 75,000
MONBAT BATTERY 12V/200AH N 125,000
MONBAT BATTERY 12V/210AH N 120,000


ELSON BATTERY
ELSON BATTERY 12V/200AH N 115,000

MICROTEC BATTERY
MICROTEC BATTERY 12V/200AH N 105,000


OKAYA BATTERY
OKAYA BATTERY 12V/200AH N 105,000

GLT BATTERY
GLT BATTERY 12V/100AH N 45,000
GLT BATTERY 12V/150AH N 65,000
GLT BATTERY 12V/200AH N 90,000

ZEEDIX BATTERY
ZEEDIX BATTERY 12V/100AH N 45,000
ZEEDIX BATTERY 12V/150AH N 70,000
ZEEDIX BATTERY 12V/200AH N 90,000


RITAR/COWIN BATTERY
RITAR BATTERY 12V/100AH N 62,000
RITAR BATTERY 12V/150AH N 90,000
RITAR BATTERY 12V/200AH N 125,000



QUANTA BATTERY
QUANTA BATTERY 12V/100AH N 70,000
QUANTA BATTERY 12V/150AH N 98,000
QUANTA BATTERY 12V/200AH N 125,000


BATTERY RACK
BATTERY RACK 2 BATTERY N 15,000
BATTERY RACK 4 BATTERIES N 30,000
BATTERY RACK 8 BATTERIES N 50,000


CHARGE CONTROLLER
ROY SOLAR SERIES
20A 12/24V PWM CONTROLLER N 20,000
30A 12/24V PWM CONTROLLER N 25,000
40A 48v PWM controller (LED) N 50,000
30A 96v PWM controller (LCD) N 120,000
60A 48v PWM controller (LCD) N 95,000
COWIN SERIES
20A 12/24V PWM CONTROLLER N 15,000
30A 12/24V PWM CONTROLLER N 20,000
40A 12/24V PWM CONTROLLER N 25,000
50A 12/24V PWM CONTROLLER N 32,000
60A 12/24V PWM CONTROLLER N 41,000
40A 48v PWM controller (LED) N 25,000
50A 48v PWM controller (LED) N 32,000
60A 48v PWM controller (LED) N 50,000

COWIN MPPT SERIES

40A 12/24/48v MPPT controller (LCD) N 80,000
60A 12/24/48V MPPT controller (LCD) N 130,000

EPEVER MPPT SERIES
12/24/48 /45A N 145,000
12/24/48 /60A N165,000


FANGUNPSUN MPPT SERIES
30A 24V N50,000
60A 48v N150,000
70A 48v N170,000
80A 48v N180,000

SOLAR PANELS

JOY SOLAR PANEL
150w MONO -N32,000
200w MONO -N33,000
260w MONO -N54,000
320w MONO -N73,000

TRINA SOLAR PANEL

300w MONO -N85,000
320w MONO -N110,000


YINGLIN SOLAR PANEL
100w POLY -N22,000
150w POLY -N33,000
200w POLY -N39,000
260w POLY -N51,000
310w POLY -N62,000


100w MONO-N25,000
150w MONO -N33,000
200w MONO -N39,000
260w MONO -N59,000
320w MONO -N74,000

CANADIAN SOLAR PANEL

MONO-
290w. N60,000
330w. N66,000

POLY
270w. N45,000
275w. N59,000


FRIDGE AND FREEZER

SOLAR FRIDGE AND FREEZER
CRS 100L ------------N166,000
CRS 180L ------------N205,000
CRS 280L ------------N305,000
CSF 152JA --------- -N182,000
CSF 212JA -------- -N220,000
CSF 302JA --------- N277,000



DC CIRCUIT BREAKER 63A/120V---500V 2 POLE N 8,000
DC CIRCUIT BREAKER 125A/500V 2 POLE N 14,000


COMPLETE SOLAR SOLUTION




Call-07058562938 Bright Solar Power

WHATSSAP 08187995847

FOR PURCHASE/ DELIVERY /INSTALLATION NATIONWIDE
Re: Solar Energy, A Complement To FTA by zeestone99(m): 3:05pm On Apr 29, 2018
Pricelist

Solar panels

Flames
300watts mono - 56k
300watts poly - 50k
250watts mono - 45k
250watts poly - 41k
200watts mono - 38k
200watts poly - 35k
150watts mono - 28k
150watts poly - 25k

Other products in stock includes Canadian solar, suntech, flames etc

Inverters
Felicity
3.5kva/24v( 35amps charging current) - 165k
5kva/48v ( 30amps charging current) - 185k
7.5kva 48v (40amps charging current) - 340k
10kva 48v- 395k

Spectra
1.5kva 24v - 70k
3.5kva 48v - 165k
Other products includes sukam, vilpower, microtek, axpert etc

Batteries (200ah)
Quanta - 125k
Monbat - 130k
Long - 115k
Spectra - 105k
Microtek - 105k
Okaya - 100k
Other products in stock includes luminous, genus, monbat, toplight etc

We have customized Roof mount, Combiner box etc in stock.

Call/watapp 08117398294 or email Info@monzpowersolutions.com

You can also like our page on facebook.com/monzpowersolutions for beautiful installation pictures.
Re: Solar Energy, A Complement To FTA by makavele: 4:53am On Apr 30, 2018
Saipro:


Eagerly anticpating your link(s)

I replied you; brov.

Please check.
Re: Solar Energy, A Complement To FTA by Nobody: 9:15am On Apr 30, 2018
DMerciful:
Led TV and fan should not be more than 70w....mine is 42inch led TV and it's 50w and fan 20w

What brand is your 20watt fan? I need a low wattage fan.
Re: Solar Energy, A Complement To FTA by mcTrinity(m): 10:35am On Apr 30, 2018
Good morning...

to the sellers; who deals on Eastman battery?

Re: Solar Energy, A Complement To FTA by DMerciful(m): 11:16am On Apr 30, 2018
QASA....its a rechargeable fa. I have 3 of it grin
Cocobuttah:


What brand is your 20watt fan? I need a low wattage fan.
Re: Solar Energy, A Complement To FTA by kiekie1(m): 11:29am On Apr 30, 2018
mcTrinity:
Good morning...

to the sellers; who deals on Eastman battery?


Feel free to contact us for detailed enquiries & supplies

Contact:
Smartcell global services
081-350-31951

(1) (2) (3) ... (391) (392) (393) (394) (395) (396) (397) ... (1853) (Reply)

FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread

Viewing this topic: kristien4(m), Valto(m)

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 77
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.