Re: Solar Energy, A Complement To FTA by S007: 5:40pm On May 31, 2018 |
mcTrinity: MS4124PE - 105A DC /24V System @25degreeC MS4348PE - 55A DC /48V System @ 25degreeC PT100 - 100A /Charge controller I use MS4348. I never charge with PHCN though. 3 Likes |
Re: Solar Energy, A Complement To FTA by mcTrinity(m): 6:29pm On May 31, 2018 |
S007: thanks... that's what we (myself and client) are trying to achieve; to charge without PHCN. Already gotten 16# of Canadian 330w panel with PT-100. About to acquire 12# of 12v/200Ah battery. trying to confirm if at worst weather situation, the Magnum will be cable of charging the 3 strings. looks like I'll make the panels 20# or 24# since I'm looking at about 18A for each string with the Magnum MS4348 |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 8:06pm On May 31, 2018 |
mcTrinity: Reach me for your batteries... Gracias Price list Batteries batteries batteries Quanta - 124k Monbat - 124k Spectra - 110k Nxt index exide - 120k Gaston - 115k Long - 120k Call/whatapp 08117398294 to order now |
Re: Solar Energy, A Complement To FTA by Saipro(m): 8:40pm On May 31, 2018 |
NiyiOmoIyunade:I concur. Tried it first time (thinking I was preventing a future short out. Batteries never recovered. The second attempt taught me the error in my ways. I think I might have inadvertently damaged the lignosulphate coating. Batteries bigger than GC2 can crunch your spine too. 1 Like |
Re: Solar Energy, A Complement To FTA by obimind(m): 8:59pm On May 31, 2018 |
DMerciful:It gladens my heart to announce to this honourable house that my ep solar mmpt(i tracer) has been fixed and is working perfectly well. Shout out to Dmerciful who made this possible. Man you rock! 6 Likes |
Re: Solar Energy, A Complement To FTA by efuro(m): 10:14pm On May 31, 2018 |
obimind: Dmerciful has earned my salute again. Am proud of your selfless effort in making your fellow solar owners happy. Oga Obimind, congrats and thanks for updating us back as requested. 4 Likes |
Re: Solar Energy, A Complement To FTA by obimind(m): 10:39pm On May 31, 2018 |
efuro:Thanks Efuro! You can't just imagine how excited I am Sir. For me, immediately I got the delivery from Nipost this afternoon, I had to start spreading the good news to as many I knew that uses solar in Makurdi(Benue). I started with my installer. I told him to please help me tell his clients that there is a very reliable contact that takes care of mppt cc issues. Dmerciful, you deserve some accolades. You're just too nice Sir. May God continually bless you beyond ur imagination. Amen! 7 Likes |
Re: Solar Energy, A Complement To FTA by S007: 7:24am On Jun 01, 2018 |
mcTrinity: I have an almost exactly similar setup. I have 16 340W Canadian solar panels in a 4X4 configuration. Pt100 charge controller 48V, 630AH Trojan batteries. MS4348 Inverter Magnum Panel and other accessories. The solar panels are well capable of charging the batteries. CC wakes up as early as 7am. Even on cloudy days, batteries are on float by 1pm. PHCN supply is terrible in my area. I never bothered to connect it to the inverter. AC input breaker is permanently switched off on the Magnum Panel. Inverter charging on the remote is left disabled. I encourage you to go for it. This system will give you peace of mind. Mine is a DIY. 3 Likes |
Re: Solar Energy, A Complement To FTA by DMerciful(m): 8:08am On Jun 01, 2018 |
Thanks for ur patronage and feedback to the house... Gracias obimind: |
Re: Solar Energy, A Complement To FTA by S007: 8:08am On Jun 01, 2018 |
mcTrinity: Don't forget, the recommended max PV input on the PT100 is 6600W. Theoretically, that should be about 20 pieces of 330W panels. If you can hit that ceiling with weather situation in Naija all year round is another point of discussion. Personally I will not be comfortable with 24 panels on one PT100 CC. At this point, you might have to start thinking of another CC. 1 Like |
Re: Solar Energy, A Complement To FTA by Tchyfingy: 10:05am On Jun 01, 2018 |
Good morning, I have a solar system comprising of 6 310W Yinglin panels in 2s3p orientation, 4kva 48V mustpower IR-series inverter, TBB 150V-60A charge controller and 4 200ah Quanta batteries. My current appliances on the inverter are 2 LED TVs, 1 LCD TV, Freezer (runs for 4-5hrs), 2 ceiling fans, LED lighting bulbs and DSTV decoder. All the appliances dont run at the same time though. I want to upgrade my panels and would love to know the best configuration to get the best out of my system. Should i add two more 310W panels in a 2s4p or should i go for three 310W panels in a 3s3p configuration? |
Re: Solar Energy, A Complement To FTA by Barezzi(m): 10:15am On Jun 01, 2018 |
It doesn't make any difference, as the cc will simply clip the current. Operating the cc at max current is another matter entirely as opinions vary. Some say it'll shorten its life, others swear it's built into the design for it to function continuously at max. I agree with you I'd put max 20 330w panels(4S5P) on the cc. S007: |
Re: Solar Energy, A Complement To FTA by tpapi: 11:10am On Jun 01, 2018 |
shithapuns:hello, pls I wanted to ask if Wellman can also be used to boost up sperm count n ow effective is it 1 Like |
Re: Solar Energy, A Complement To FTA by DMerciful(m): 12:19pm On Jun 01, 2018 |
Warris this tpapi: |
Re: Solar Energy, A Complement To FTA by mcTrinity(m): 12:53pm On Jun 01, 2018 |
Barezzi: yes you're correct... The manual stated it's rated for 6.6kw but larger PV array may be used since its current limited to 100A. Nevertheless, I'll go with advice of 20# maximum to be on a safe side. I just can't fittin't shout.. lolzzz Thanks |
Re: Solar Energy, A Complement To FTA by mcTrinity(m): 12:56pm On Jun 01, 2018 |
S007: thats good.... thanks very much. I appreciate |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 3:38pm On Jun 01, 2018 |
DMerciful: 2 crate of Heineken 4 u 1 Like |
Re: Solar Energy, A Complement To FTA by Monlo(m): 4:38pm On Jun 01, 2018 |
DMerciful: Kudos to my man,anytime anyday.He keeps making DIYers happy in the background without much noise here and there.Keep it up,your reward awaits you!!!!!! One love. |
Re: Solar Energy, A Complement To FTA by garbamaza: 4:47pm On Jun 01, 2018 |
Dear solar Gurus can I use 6 pieces of Trojan IND17 6V batteries with 2.5kva 36v luminous inverter. Thanks |
Re: Solar Energy, A Complement To FTA by DMerciful(m): 5:24pm On Jun 01, 2018 |
Thanks bro...doing our own small contribution Monlo: |
Re: Solar Energy, A Complement To FTA by DMerciful(m): 5:25pm On Jun 01, 2018 |
thanks chairman.... zeestone99: |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 5:47pm On Jun 01, 2018 |
garbamaza: yes and no. i assume the trojan is 370 - 400ah, 6v? yes it will work and power your loads. nope: the inverter isnt capable of charging it effectively, best your add apprioprate solar panels config |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 5:51pm On Jun 01, 2018 |
obimind: does your expertise extend to morning star mppt cc? i have a 45a ms cc, which i connected 4 x 250w mono panels in series, back in the days, and i think the high vmp blew it.was truthful and contacted morning star corp and they said its not covered under waranty, as i may hv exceeded the vmp rating the last morning star webinar on MAINTAINING HEALTHY BATTERIES IN AN OFFGRID SYSTEM https://www.youtube.com/watch?v=b6ZKKJLNi80&feature=youtu.be |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 6:01pm On Jun 01, 2018 |
My Oga DMerciful. Well done. This good news made my day. Like another poster said earlier, you are very quietly doing great things behind the scenes without noise or attention seeking and I can personally testify also that you are always willing to listen and to render assistance. Kudos and God bless! efuro: |
Re: Solar Energy, A Complement To FTA by GeorgeD1(m): 6:38pm On Jun 01, 2018 |
kiekie1: ok looks like it's the input amps that can go as high as 100a and above. my own inverter is set at 50% charge rate and as at this morning i'm seeing 32 amps dc output meaning max charging amps (100% setting) would be something around 64 amps dc. thanks for the observation. have corrected my post accordingly although i hardly charge with shore power (phcn, gen, etc). |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 6:49pm On Jun 01, 2018 |
GeorgeD1: Ok Boss. My regards ! |
Re: Solar Energy, A Complement To FTA by dgr8truth(m): 7:11pm On Jun 01, 2018 |
For sale N120k, interested call/WhatsApp 08060313355 1 Share
|
Re: Solar Energy, A Complement To FTA by DMerciful(m): 9:14pm On Jun 01, 2018 |
I can check it... Whatsapp me. earthrealm: |
Re: Solar Energy, A Complement To FTA by DMerciful(m): 9:15pm On Jun 01, 2018 |
Thanks for the kind words.... Much appreciated NiyiOmoIyunade: |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 12:36am On Jun 02, 2018 |
Must Power Star Light inverters with LCD display 1000w 12v=85k 1500w 12v=95k 3kva(2000w)-12v=115,000 4kva(3000w)-24v=160,000 5kva(4000w)-24=250,000 6kva(5000w)-24/48= ..... 7.5kva(6000w)-24/48= ..... EP Solar 12/24/36/48v 60a mppt(i tracer) solar charge controller @ 128k EP Solar 12/24v 40a MPPT(a series ep ever) solar charge controller @ 75k Trojan 12v 200a J200re USA flooded batteries @ 129k...(limited quantity in stock) Quanta Amaron 12v 200a vrla battery @ ... Long battery 12v 200a agm battery @..... Solution battery 12v 200a agm battery @85k Yachi solar panels ; 150w poly panels........@35k 250w poly panels.......@47k "limited stock" 300w poly panels........@58k "limited stock" DISCOUNTED PRICES ! CALL US NOW !! Magnum 4348 USA inverter ....@900k Victron multiplus 3kva 48v .....@600k Canadian 330w solar panel.....@65,500 bulk price Joysolar modules : 160w mono 30000 200w poly 35000; mono 40000 320w poly 52,000 With 30k , I can offer you a set of pro solar roof mounts including ; 2 qty solar mount rail "4200mm" , 4 qty rack end clamp, 6 qty mid clamp, 6 qty L feet with rubber & special screw.... Same goes to angle positioning solar kits; - Adjustable front leg - Adjustable rear leg - Rail splice kit - Grounding lug *AUTHORISED DEALER PRAGMATIC TECHNOLOGIES* All our prag products comes with reliable warranty *AUTHORIZED DEALER INDIAN INVERTERS / BATTERIES ... Luminous PRODUCTS* All our products come with 1 year Warranty *AUTHORIZED DEALER SOLAR SHOP LTD PRODUCTS* All our products come with 1 year Warranty For best affordable prices , contact Smartcell Global Services,Lagos Nigeria. Simply call Sir Frankie "08135031951" for purchase,fast delivery and waybills .. Thanks !! 1 Like |
Re: Solar Energy, A Complement To FTA by mcTrinity(m): 7:52am On Jun 02, 2018 |
zeestone99: OK sir... considering Quanta or Eastman Tubular Gel... will let you know if I settle for Quanta. cheers |
Re: Solar Energy, A Complement To FTA by mcTrinity(m): 7:54am On Jun 02, 2018 |
GeorgeD1: Oga George D1, Good morning sir... please, I thought you're using 3 strings of 12 batteries (I sit to be corrected). How come you set your charging at 50%? |
(1) (2) (3) ... (405) (406) (407) (408) (409) (410) (411) ... (1855) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: sheDD(m) and 7 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 94 |