Re: Solar Energy, A Complement To FTA by Namzy(m): 6:04am On Oct 07, 2018
mctfopt:

I have been using it since 2015. Super cool controller.
Cool but heard it does not have equalize option
Re: Solar Energy, A Complement To FTA by mctfopt: 6:26am On Oct 07, 2018
Namzy:

Cool but heard it does not have equalize option

Yes, it does not have such. Used it on a fairly used battery from 2015 until this year when I changed the batteries. Pretty a great, affordable little charge controller that is totally worth the price. But if money is no problem, there are premium products out there with all the bells and whistles cheesy
Re: Solar Energy, A Complement To FTA by Saipro(m): 8:55am On Oct 07, 2018
Namzy:

Have not seen this before any reviews? Meanwhile some people still believe desufators are snake oil but if u insist you can get the more popular powerpulse. I intend to buy it on black Friday to test ie if it's cheaper that day
I have controlled empirical proof that they work (I've used the Infinitum brand for years) but not in all cases and definitely not with batteries dead from wear and tear (i.e. aging).

Best added to the batteries from the outset and works well with sulphation from batteries left standing unattended (not cyclic abuse though the latter also experience something of a revival but not for long as plate shedding soon appears to become another problem).

The barebone device pictured in original post .... I have no idea what it does nor what it might be capable of (in terms of benefits and possibly havoc).

2 Likes

Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 12:49pm On Oct 07, 2018
I have used the BLS and PowerPulse model of desulphators for years and I can attest that the results are similar to what Oga Saipro has said for his own Infinitum brand.

I would say that the benefits are there especially when added from the outset but you may as well not bother since you could have applied the cash used to buy desulphators towards battery replacement instead. To do it right you need to apply a desulphator to each individual battery e.g in a 48v system with 4 units of 12v batteries, it is better to use 4 pcs of 12v desulphator attached to each individual battery vs 1pc 48v for the entire bank - and the cost of doing it right would be enough to buy at least one new battery instead grin

I am convinced that on a net basis the benefits of a desulphator offer only very marginal improvement over giving a proper charge or controlled overcharge to the batteries - people who experience battery longevity after attaching a desulphator are actually experiencing the benefits of a regular proper charge and misattributing it to their desulphator.

Be aware that if you use any of the MustPower brands or clone inverters, the pulses/voltage spikes the desulphator sends out are likely to damage your inverter control board and I think thesame is true for the older IPowerPlus (Axpert) inverters as well.

All in all, I would advise you invest in proven equipment to charge your batteries properly vs. spending money on the very negligible improvements a desulphator may offer.



Saipro:

I have controlled empirical proof that they work (I've used the Infinitum brand for years) but not in all cases and definitely not with batteries dead from wear and tear (i.e. aging).

Best added to the batteries from the outset and works well with sulphation from batteries left standing unattended (not cyclic abuse though the latter also experience something of a revival but not for long as plate shedding soon appears to become another problem).

The barebone device pictured in original post .... I have no idea what it does nor what it might be capable of (in terms of benefits and possibly havoc).

3 Likes

Re: Solar Energy, A Complement To FTA by GeorgeD1(m): 6:43pm On Oct 07, 2018
as far as desulphators go, I've been using the bls (battery life saver) for years now and I must say I'm impressed with it's performance. regardless of the seemingly negative sentiments against desulpators on here, I wouldn't be caught out without one. I remember a couple years ago when thunder struck my system and damaged my first bls, the speed with which I rallied to replace it speaks volumes about the high premium I place on it's benefits.

this and other good practices have ensured my zenith batteries have gone over six years now without needing replacement.

5 Likes

Re: Solar Energy, A Complement To FTA by kiekie1(m): 8:22pm On Oct 07, 2018
DISCOUNTED PRICES!!!

USA Magnum inverter 4124 ..... 930,000
USA Deka 210a battery .............190,000

Felicity 200a battery ...................90,000
Motoma 200a battery ................115,000
Cinemax 200a battery ................115,000
Cinemax 210a battery ................120,000

Morningstar 60a mppt ...............215,000
Morningstar 45a mppt................190,000
Tsm2 display ...............................60,000
Schneider 60a mppt ....................240,000

Battery equaliser 6-48v... 35,000 25,000

Epsolar Epever solar charge controllers
MT50 display ..................................15,000
Epever 12-24v 30a mppt ................50,000
Epever 12-24v 40a 4210N mppt ...........65,000
Epever 12-48v 60a itracer mppt....135,000

Epsolar PWM
30a 12-24v VS3024A .........30,000
45a 12-48v VS4548BN .......70,000
60a 12-48v VS6048AU .......80,000

Fangpusun MPPT
30a 12-24v .............................55,000
60a 12-48v mppt TR victron clone series ..125,000
60a 12-48v outback clone with display.......145,000
80a 12-48v mppt outback clone .................155,000

Must Power Star Light inverters with LCD display
1000w 12v=92k
1500w 12v=102k
3kva(2000w)-12v=115,000
4kva(3000w)-24v=155,000
5kva(4000w)-24/48=240,000
6kva(5000w)-24/48= 260,000
7.5kva(6000w)-24/48= 280,000
SS Power inverters with LCD display
1.5kva 12/24v= 75,000
2kva 12/24v= 85,000
3.5kva 24v= 130,000
5kva 24/48v= 160,000
7.5kva 48v= 280,000
10kva 48v= 340,000
10kva 48/96v (standing)= 350,000

Keye 1.2kva/12v(without charger) 13,000
Keye 2.2kva/12v(without Charger) 18,000
Keye pure sinewave series
Keye 800va/12v 45,000
Keye 1.2kva/12v 55,000
Keye 3.5kva/24v 150,000
Keye 3.5kva/48v 150,000
Keye 5kva/24v 170,000
Keye 5kva/48v 170,000
Keye 7.5kva/48v 350,000
Keye 10kva/48v 370,000
Fangpusun 80a MPPT @ 155k
EP Solar 12/24/36/48v 60a mppt(i tracer) solar charge controller @ 135k
EP Solar 12/24v 40a MPPT solar charge controller @ 65k
Trojan 12v 200a J200re USA flooded batteries @ 129k...(limited quantity in stock)
Trojan 12v 205a agm batteries ... 164k
Trojan 6v 315a agm battery.... 155k
Trojan 6v 375a agm battery .... Arriving soon
USA Deka 12v 210a .......190k
USA Mnspd 300 DC / AC ..... 50k
Schneider DC SPD ..........30k
AC/DC Clamp meters
UNIT 203 & 210 ...N 25kk
DC display meters 0-30v...N 1600
DC display meters 0-120v..N 2200
ZHC Battery equalizer 12/24/36/48 volts..... 24k
Quanta Amaron 12v 200a vrla battery @ ...130k
Long 200a AGM batteries .... N120,000
Long 150a slim AGM battery..93,000
Long 100a AGM battery ........ 65,000
Long 100a carbon battery ..... 75,000
Superceed Batteries
12v 100ah= 40,000
12v 150ah= 60,000
12v 200ah= 80,000
Maximum power batteries
12v 100ah= 40,000
12v 150ah= 60,000
12v 200ah= 80,000
Double tech batteries
12v 100ah= 40,000
12v 150ah= 60,000
12v 200ah= 80,000
Network batteries
12v 110ah= 50,000
12v 180ah= 70,000
12v 210ah= 90,000
12v 250ah= 115,000
Flames 300w mono .... 47k
Watts meter "kill-a-watt meter" ....9k
Yachi solar panels ;
150w mono panels........@35k
260w mono panels.......@48k "limited stock"
310w mono panels........@59k "limited stock"
DISCOUNTED PRICES ! CALL US NOW !!
Magnum 4348 USA inverter ....@900k
Victron multiplus 3kva 48v .....@600k
Schneider connect 2524..........@550k
Growatts SPF3000 plus hybrid/solar inverter...@290k
Growatts SPF 5000 hybrid/solar inverter... @320k
Canadian 340w mono solar panel"Korean cells" .... Offloading
Canadian 330w solar panel.....@60,000 bulk price
Sunshine solar modules :
130w poly 23000
250w poly 39000
300w Mono 52,000
Quality chinese panels best price:
100w poly 18500
100w mono 19500
150w poly 23000
200w mono 33000
260w poly 35500
260w mono 39000
320w poly 45500

Mercury Industrial Stabilizer available now
10kva Single phase 100,000
15kva Single phase 157,000
20kva Single phase 195,000
30kva Single phase 300,000
15kva 3Phase in/out 195,000
30kva 3Phase in/out 320,000
50kva 3Phase in/out 830,000

Mercury Spirit Plus Hybrid Inverters are available now
2000 Spirit 2kva 120,000
2001 Spirit Plus 2kva 135,000
3001 Spirit Plus 3kva 165,000
5001 Spirit Plus 5kva 220,000
3kva Soho Inverter 185,000
5kva Soho Inverter 265,000
7.5kva Soho Inverter 300,000

BATTERIES
Mercury 1.2kva Inverter 40,000
Mercury 2.4kva Inverter 45,000
Mercury 200ah GEL battery 140,000
Mercury 200ah AGM battery 100,000
Mercury 100ah AGM battery 55,500
Mercury 220ah Tubular battery 100,000

LUMINOUS BATTERIES:
Luminous 150AH/12V SMF .... 92k
Luminous 200AH/12V SMF .....115k
Luminous Blue 200AH/12V .....125k
Luminous tubular 220AH/12V..105k

LUMINOUS PURE SINEWAVE INVERTERS:
Luminous 850va/12v hybrid...52k
Luminous 875va/12v Eco.......37k
Luminous 1.5kva/24v Eco.......57k
Luminous 1.5kva/24v Zelio.....75k
Luminous 1.5kva/24v hybrid...80k
Luminous 3.5kva/48v Cruise..180k
Luminous 5kva/96v Cruise ....400k
Luminous 7.5kva/120v Cruise..500k
Luminous 10kva/180v ...........660k
Luminous 15kva/240v.............1m
Luminous 20kva/360v............ ----

Protek 200L solar water heater... N215,000
With 30k , I can offer you a set of pro solar roof mounts including ;
2 qty solar mount rail "4200mm" ,
4 qty rack end clamp,
6 qty mid clamp,
6 qty L feet with rubber & special screw....
Same goes to angle positioning solar kits;
- Adjustable front leg
- Adjustable rear leg
- Rail splice kit
- Grounding lug

WHATSAPP::: https:///send?phone=2348170385620

*AUTHORISED DEALER PRAGMATIC TECHNOLOGIES*
All our prag products comes with reliable warranty
*AUTHORIZED DEALER INDIAN INVERTERS / BATTERIES ... Luminous PRODUCTS*
All our products come with 1 year Warranty
*AUTHORIZED DEALER SOLAR SHOP LTD PRODUCTS*
All our products come with 1 year Warranty.
For best affordable prices contact,
Smartcell Global Services,Lagos Nigeria.
Simply call Sir Frankie "08135031951" for purchase,fast delivery and waybills .. Thanks !!

Re: Solar Energy, A Complement To FTA by Namzy(m): 10:25pm On Oct 07, 2018
GeorgeD1:
as far as desulphators go, I've been using the bls (battery life saver) for years now and I must say I'm impressed with it's performance. regardless of the seemingly negative sentiments against desulpators on here, I wouldn't be caught out without one. I remember a couple years ago when thunder struck my system and damaged my first bls, the speed with which I rallied to replace it speaks volumes about the high premium I place on it's benefits.

this and other good practices have ensured my zenith batteries have gone over six years now without needing replacement.
Any equalization done?
Re: Solar Energy, A Complement To FTA by GeorgeD1(m): 10:41pm On Oct 07, 2018
the zenith batteries are agm so strictly no equalization allowed although I do this on limited basis.
Re: Solar Energy, A Complement To FTA by earthrealm(m): 12:22am On Oct 08, 2018
NiyiOmoIyunade:
I have used the BLS and PowerPulse model of desulphators for years and I can attest that the results are similar to what Oga Saipro has said for his own Infinitum brand.


Be aware that if you use any of the MustPower brands or clone inverters, the pulses/voltage spikes the desulphator sends out are likely to damage your inverter control board and I think thesame is true for the older IPowerPlus (Axpert) inverters as well.

All in all, I would advise you invest in proven equipment to charge your batteries properly vs. spending money on the very negligible improvements a desulphator may offer.




maybe not exactly true, or i am lucky, used a desulphator for over 18months on a 4kva muspower inverter, using same desulphator on a highpower inverter, zero issues. even using a powerpulse desulphator on luminous ion inverter no issue, and even hv a desulphator hooked up to my car battery 24/7, no issues still
Re: Solar Energy, A Complement To FTA by DMerciful(m): 6:23am On Oct 08, 2018
I am yet to be convinced desulphators improve battery longevity even marginally. Same with battery balancers. A good charging and discharging technic ensures longevity. In a way I feel that charging the batteries individually is the best approach even though the most expensive.

1 Like

Re: Solar Energy, A Complement To FTA by Trippledots(m): 12:28pm On Oct 08, 2018
surrogatesng:
Brand new 42 inch Led Tv for sale.Power consumption is just 30 watts.Good quality.It works with mtn lumos or other solar systems.Price is 75,000 Naira.For more information call 07068410532,08170368264

Is dis still available? Model number pls
Re: Solar Energy, A Complement To FTA by surrogatesng: 12:33pm On Oct 08, 2018
It is unbranded

Trippledots
post=71893229:



Is dis still available? Model number pls
Re: Solar Energy, A Complement To FTA by surrogatesng: 1:31pm On Oct 08, 2018
It is available.Whatsapp 08170368264
Trippledots:


Is dis still available? Model number pls
Re: Solar Energy, A Complement To FTA by surrogatesng: 1:31pm On Oct 08, 2018
Whatsapp 08170368264
Trippledots:


Is dis still available? Model number pls
Re: Solar Energy, A Complement To FTA by Trippledots(m): 2:54pm On Oct 08, 2018
Hello all, pls i need advice.

I want to have an automatic transfer switch to alternate between mains and my inverter unit.... Is there any simple one i can use? Pix attached is what i saw on aliexpress, is that any good?

Re: Solar Energy, A Complement To FTA by Trippledots(m): 2:55pm On Oct 08, 2018
surrogatesng:
Whatsapp 08170368264

Ok
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 3:59pm On Oct 08, 2018
The last remaining BLS unit I had was a 24v

At least the BLS desulphator works off radio signals calibrated to a specific frequency to break up lead sulphate crystals vs the other types that send high voltage spikes/jolts into the battery.

One sure thing I know all the desulphators do is they improve charge acceptance - the battery seems to get full faster soon after you attach a desulphator.

To do an objective test of desulphator effectiveness, you have to control for other variables e.g how good of a charge your battery gets, average depth of discharge e.t c - since this is almost impossible to do (isolate the effect of other variables), the only test is to run two battery banks of the same brand and batch under identical charge and discharge conditions with the only difference being a desulphator attached to one bank and see how long each battery bank lasts before ultimate failure.


GeorgeD1:
as far as desulphators go, I've been using the bls (battery life saver) for years now and I must say I'm impressed with it's performance. regardless of the seemingly negative sentiments against desulpators on here, I wouldn't be caught out without one. I remember a couple years ago when thunder struck my system and damaged my first bls, the speed with which I rallied to replace it speaks volumes about the high premium I place on it's benefits.

this and other good practices have ensured my zenith batteries have gone over six years now without needing replacement.
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 4:08pm On Oct 08, 2018
I have been using desulphators since 2011 in both car and house.

I have gotten results no different from other people who don't use them - some batteries seem to last forever while others die early despite all the measures taken to keep them healthy and alive.

The point about desulphators ruining inverter control circuitry was strictly for MustPower type inverters and not in general - Indian designs like Luminous e.t.c use different internal components and seem entirely unaffected, same for vehicle brain boxes e.t.c - you should confirm if you actually charge from the mains with your Mustpower and if indeed it still charges after using a 'pulse' type desulphator - not the BLS which uses radio frequency signals.

If you use a pulse type desulphator and your MustPower still charges correctly then you are probably the exception rather than the norm.





earthrealm:


maybe not exactly true, or i am lucky, used a desulphator for over 18months on a 4kva muspower inverter, using same desulphator on a highpower inverter, zero issues. even using a powerpulse desulphator on luminous ion inverter no issue, and even hv a desulphator hooked up to my car battery 24/7, no issues still
Re: Solar Energy, A Complement To FTA by surrogatesng: 4:43pm On Oct 08, 2018
Brand new 43 inch Led Tv for sale.This Tv power consumption is just 30 watts.It can be powered by a small battery and inverter.The audio and video quality is good.Please kindly watch the youtube video below for. demo of this product.To order for this product call 08170368264


https://www.youtube.com/watch?v=l3CyQMobnvE
Re: Solar Energy, A Complement To FTA by earthrealm(m): 7:03pm On Oct 08, 2018
NiyiOmoIyunade:
I have been using desulphators since 2011 in both car and house.

I have gotten results no different from other people who don't use them - some batteries seem to last forever while others die early despite all the measures taken to keep them healthy and alive.

The point about desulphators ruining inverter control circuitry was strictly for MustPower type inverters and not in general - Indian designs like Luminous e.t.c use different internal components and seem entirely unaffected, same for vehicle brain boxes e.t.c - you should confirm if you actually charge from the mains with your Mustpower and if indeed it still charges after using a 'pulse' type desulphator - not the BLS which uses radio frequency signals.

If you use a pulse type desulphator and your MustPower still charges correctly then you are probably the exception rather than the norm.






my mustpower charges solely from grid in this installation. below is the link to the desulphator.
https://www.amazon.com/gp/product/B00K6ANLWI/ref=ox_sc_act_title_6?smid=A1UQYBFF910O5I&psc=1

guess am lucky?
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 7:14pm On Oct 08, 2018
Please see below the science behind your apparent 'good luck' in the product description

ADVANCED TECHNOLOGY
Many desulfator products use an old technology inductor design to generate the pulse to desulfate a battery. This old technology creates a harsh inductor peak that can be damaging to the battery plates.
Utilising our new capacity pulsing method a “soft” peak is generated so dissolving sulfates without damaging the battery plates.





earthrealm:


my mustpower charges solely from grid in this installation. below is the link to the desulphator.
https://www.amazon.com/gp/product/B00K6ANLWI/ref=ox_sc_act_title_6?smid=A1UQYBFF910O5I&psc=1

guess am lucky?

Re: Solar Energy, A Complement To FTA by Saipro(m): 8:41pm On Oct 08, 2018
NiyiOmoIyunade:
Please see below the science behind your apparent 'good luck' in the product description

ADVANCED TECHNOLOGY
Many desulfator products use an old technology inductor design to generate the pulse to desulfate a battery. [b]This old technology creates a harsh inductor peak that can be damaging to the battery plates
.
Utilising our new capacity pulsing method a “soft” peak is generated so dissolving sulfates without damaging the battery plates. [/b]
So the increased plate shedding had been previously documented.
Re: Solar Energy, A Complement To FTA by makavele: 11:16pm On Oct 08, 2018
NiyiOmoIyunade:
The last remaining BLS unit I had was a 24v - I gave it out to Zeestone for free 1 or 2 years ago.


You talk like a b1tch . . . No offense intended !

4 Likes 1 Share

Re: Solar Energy, A Complement To FTA by Trippledots(m): 1:13am On Oct 09, 2018
Trippledots:
Hello all, pls i need advice.

I want to have an automatic transfer switch to alternate between mains and my inverter unit.... Is there any simple one i can use? Pix attached is what i saw on aliexpress, is that any good?

Hi, anyone pls?
Re: Solar Energy, A Complement To FTA by Trippledots(m): 1:14am On Oct 09, 2018
bigrovar:


sorry for taking long. Here is the video of the dc fan in action.

https://www.youtube.com/watch?v=APUNR5FEozM

Wow... Thanks for the video. Much appreciated.
Re: Solar Energy, A Complement To FTA by bigrovar(m): 3:15am On Oct 09, 2018
At least the BLS desulphator works off radio signals calibrated to a specific frequency to break up lead sulphate crystals vs the other types that send high voltage spikes/jolts into the battery.

I highly doubt the science behind this. Or any device that claim to reverse battery sulphation. In the end Belief in these devices is like belief in a religion. Other than anecdotal evidence, there is no proof one way or the other, yet some believe fully, perhaps even fanatically, while others, including myself, do not believe in the supposed power of such devices and put our effort and money elsewhere.
So all I can say is "to each his own".

2 Likes

Re: Solar Energy, A Complement To FTA by makavele: 5:30am On Oct 09, 2018
Trippledots:


Hi, anyone pls?

Contact JUO.
I bought that exact type off him and it has been working flawlessly;
for power transfer for my refrigerators between inverter power and grid power.
Just know that the transfer isn't as fast as an inverter;
so expect the device(s) to go off during switching.
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 8:01am On Oct 09, 2018
No Sir! The point was - that was how little value I placed on the BLS by that time. Someone else wanted it and he was the middleman for the transaction.


makavele:


You talk like a b1tch . . . No offense intended !

1 Like

Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 8:23am On Oct 09, 2018
I too do not believe anymore in desulphators - at least based on the preponderance of observed evidence. I don't use them anymore with any inverter but I still have them in my car - perhaps I am too lazy to remove them or perhaps a part of me still hopes/believes grin

bigrovar:


I highly doubt the science behind this. Or any device that claim to reverse battery sulphation. In the end Belief in these devices is like belief in a religion. Other than anecdotal evidence, there is no proof one way or the other, yet some believe fully, perhaps even fanatically, while others, including myself, do not believe in the supposed power of such devices and put our effort and money elsewhere.
So all I can say is "to each his own".
Re: Solar Energy, A Complement To FTA by dagok(f): 9:07am On Oct 09, 2018
Still Available for Serious Buyer

Brand New HD satellite Receiver

Pre Installed with all IPTV Channel.(BEIN SPORT 1-12) and with some other 173 sports channels.
Only Consume 200MB for Full Match (90mins) and No Buffering...

Watch all FA CUP, CARLING CUP free on this HD satellite Receiver is far better than Android TV BOX

PRICE.....20K

CALL OR WHATSAPP
EMMANUEL
08132355293


IT CAN BE DELIVERED ANYWHERE IN NIGERIA.

1 Like

Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 9:12am On Oct 09, 2018
If you are electronics savvy you can wire up your own transfer switch similar to the below picture - all you need is that black beefy contactor (LC1D25008 - but in your case you pick one suitably rated for your loads and duty cycle) and some lengths of wire and you are good to go.

I can repost a wiring diagram if you want. All the more fun for you as this is a DIY focused thread.

But I must ask why you want to use an automatic transfer switch between your mains and inverter? The standard wiring protocol in Naija is to have your inverter in between the Mains and your Inverter loads, this way Inverter powers the loads when there is no mains and the inbuilt transfer switch in the inverter case transfers the loads to mains whenever mains is available.

So what exactly are you trying to do with an external transfer switch?



Trippledots:
Hello all, pls i need advice.

I want to have an automatic transfer switch to alternate between mains and my inverter unit.... Is there any simple one i can use? Pix attached is what i saw on aliexpress, is that any good?

4 Likes

Re: Solar Energy, A Complement To FTA by MegaMKO: 10:32am On Oct 09, 2018
GeorgeD1:
salam,
thanks for your enquiries. i do get my solar modules locally in lagos. will send you the guy's contact
on a personal note as i don't want to appear as if i'm advertising.

Good morning,

I will love to have the guy's contact too.

Thanks

(1) (2) (3) ... (463) (464) (465) (466) (467) (468) (469) ... (1855) (Reply)

FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread

Viewing this topic: adrusa, Dam5reey(m)

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 105
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.