Re: Solar Energy, A Complement To FTA by duwdu: 10:13am On Feb 06, 2019
ojeysky:


Documentations that I have read[1] suggests that combiner boxes are for high PVs with over 500kw. How is it going so far with your new tool?

Regards
1. https://www.quora.com/What-is-the-purpose-of-a-combiner-box-in-solar

Many thanks for the helpful info and link.

As for the package itself, FedEx reported it's still on the clearance leg with Customs as of yesterday.

........
P34c3
.....
...
Re: Solar Energy, A Complement To FTA by FrustratedMonk(f): 10:30am On Feb 06, 2019
Kiekie1 make you dey try get sense. Why you dey quote your LONG advert twice just to post another small advert angry angry

14 Likes

Re: Solar Energy, A Complement To FTA by kiekie1(m): 10:40am On Feb 06, 2019
A unit of fairly used Emerson 24v 60a bulk charger module up for sale ...#20k

Contact,
Smartcellglobal
081-350-31951

1 Like

Re: Solar Energy, A Complement To FTA by duwdu: 11:03am On Feb 06, 2019
NiyiOmoIyunade:
My Oga,

For surge protection, a device like the MNSPD 600 will do very well provided you already have a low resistance earth connection installed for your site - see product link below;

https://www.amazon.com/dp/B00BSYSZP4/ref=cm_sw_r_wa_apa_i_-jGwCbDTNSWRN

If you are a risk taker, you could even deploy an MNSPD 300 for finer/more precise surge protection given that your target operating voltage is within the MNSPD 300's MCOV range - pertinent to note, an 'ungrounded PV array' does not mean or imply that the installation is not surge protected and grounded/earthed at the DC side.

For combiner boxes you can either buy any of Midnite's boxes (premium priced) or improvise one by yourself using a suitable enclosure and properly rated DC breakers and/or busbars.


OK, thanks a lot for steering me on the right things as usual; makes my choices very clear.

With the part of your statement I have put in bold characters, and assuming I provide proper surge protection, will grounding the array to the ground connection provided on the inverter itself be sufficient or even desirable? (My apologies if I've made little sense here, as the instructions say grounded arrays may provide a path for current leakage to the inverter and are therefore not called for? I have attached some extracts from the Instructions that made me interpret it to be so, for further help.)

........
P34c3
.....
...

Re: Solar Energy, A Complement To FTA by Namzy(m): 12:26pm On Feb 06, 2019
Is their anyone selling used 16mm2 cable for cheap? I'm asking for a friend. Thanks grin
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 12:30pm On Feb 06, 2019
My Oga,

I believe that a surge arrestor cannot work effectively if it is not connected to a earth/ground point so that any fault current (surge) can be diverted safely to earth/ground. In fact having a surge arrestor in place with no earth/ground reference increases the risk of catastrophic equipment damage in the event of a surge.

To satisfy the requirements of item 11) "Grounding Instructions" and item 15) "Caution" per the screenshot below, you should simply connect the PV+ and PV- of Solar Panels from your Combiner box to the Inverter PV+ and PV- receptacles and connect the inverter's earth receptacle to your installation's permanent earth/ground point with suitably rated cables.

Install the surge protection device at the PV combiner box - connect positive of SPD to main trunk PV+ of combiner box and negative of SPD to the main trunk PV- of combiner box - it may help to use busbars in the combiner box and crimp heavy duty cable lugs (like the type used for battery cable connections) onto the Surge Protection Device's wires so this way you can torque everything down tightly onto the positive and negative busbars - the combiner box should have a 3rd busbar or wire terminal which is dedicated/already connected to central earth/ground for the installation. You must connect the 3rd wire (green earth wire) of the SPD to the combiner box earth bus bar or splice on suitable cable (crimp, do not twist wire together) so you can connect SPD directly to the central earth/ground point.

So in summary leave the actual solar panels ungrounded but ground the inverter, ground the combiner box, connect the SPD to combiner box main PV+ and PV- and definitely ground the SPD - if possible all devices should connect directly to central earth/ground but you may share thesame earth connection between combiner box and SPD.

If panels are more than 50 feet from the combiner box, you could also ground the panel mount frame/rack.

The ideal earth/ground point is a low resistance earth implemented with suitable rating, number and length of ground rods and suitably thick cables - use proper earthing chemicals where required and avoid the use of earths implemented with charcoal lumps and salt unless the charcoal has been grounded into fine powder and mixed thoroughly with suitable base materials to form a slurry.




duwdu:


OK, thanks a lot for steering me on the right things as usual; makes my choices very clear.

With the part of your statement I have put in bold characters, and assuming I provide proper surge protection, will grounding the array to the ground connection provided on the inverter itself be sufficient or even desirable? (My apologies if I've made little sense here, as the instructions say grounded arrays may provide a path for current leakage to the inverter and are therefore not called for? I have attached some extracts from the Instructions that made me interpret it to be so, for further help.)

........
P34c3
.....
...

1 Like

Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 1:47pm On Feb 06, 2019
I thought again that if budget is a constraint you could dispense with a combiner box and use a set of busbars to simulate a combiner box especially since your array is simply a set of panels in series and no parallel connections.

You would connect your panels in series as usual then run suitable gauge wire from PV + to DC Breaker (make sure breaker is rated for your high PV voltage) then from DC breaker to positive bus bar. The DC breaker allows you to isolate the array for inspection and maintenance - I would be very careful here that the breaker actually disconnects the PV as you definitely don't want to be zapped by 360vdc while attempting maintenance

But I digress....

You would connect the main PV- to a suitable gauge cable and run directly to the negative busbar. You should have free ports on the busbar to which you can now torque down your surge protection devices positive and negative cables (I still advise to crimp on cable lugs). The idea here is that you don't want to fit two cables (PV+ and SPD+) into your Inverter's PV+ terminal so that you have a firm mechanical and electrical connection (very key for lightning/surge diversion) and also to decommission the installation with minimal damage to cables.

The SPD's 3rd wire (green/earth) would then go to the installations central earth/ground point.

The busbars must be properly covered/isolated since they will be carrying dangerous DC voltages.





NiyiOmoIyunade:
My Oga,

I believe that a surge arrestor cannot work effectively if it is not connected to a earth/ground point so that any fault current (surge) can be diverted safely to earth/ground. In fact having a surge arrestor in place with no earth/ground reference increases the risk of catastrophic equipment damage in the event of a surge.

To satisfy the requirements of item 11) "Grounding Instructions" and item 15) "Caution" per the screenshot below, you should simply connect the PV+ and PV- of Solar Panels from your Combiner box to the Inverter PV+ and PV- receptacles and connect the inverter's earth receptacle to your installation's permanent earth/ground point with suitably rated cables.

Install the surge protection device at the PV combiner box - connect positive of SPD to main trunk PV+ of combiner box..........

So in summary leave the actual solar panels ungrounded but ground the inverter, ground the combiner box, connect the SPD to combiner box main PV+ and PV- and definitely ground the SPD - if possible all devices should connect directly to central earth/ground but you may share thesame earth connection between combiner box and SPD.

If panels are more than 50 feet from the combiner box, you could also ground the panel mount frame/rack.

The ideal earth/ground point is a low resistance earth implemented with......




1 Like 1 Share

Re: Solar Energy, A Complement To FTA by Trueigbo: 2:33pm On Feb 06, 2019
I have a solar system of 2 panels, 100ah battery and 1kva inverter.

I have changed the inverter twice as the inverter gets damaged and stop giving output.

What should i do because i want to get another one.
Re: Solar Energy, A Complement To FTA by mank1234(m): 8:59pm On Feb 06, 2019
Trueigbo:
I have a solar system of 2 panels, 100ah battery and 1kva inverter.

I have changed the inverter twice as the inverter gets damaged and stop giving output.

What should i do because i want to get another one.

The information you provided here can't elicit any positive feedback - it's incomplete.

Where's your location? Is it prone to extreme power fluctuations? Lightening? What's the nature or cause of the inverter failure?

What's the inverter make, model and specifications?
What's the panel wattage, connection mode (series or parallel), open circuit voltage?

What load do you run on it? Do you run apliaces with high starting power with it - blender, fridge and freezer? Can it handle such surge power?

How long do you use it before requiring a replacement? A properly sized and maintained inverter should last till you're ready to give it out.

In the absence of required indormation, it can fail for following reasons:
-can't cope with surge power from connected load
-surge from lightening or mains
-too high solar input voltage
-poor ventilation, extreme temperature
-poor charging system that raises battery voltage beyond what inverter can handle
-overloading
-internal short circuit

4 Likes

Re: Solar Energy, A Complement To FTA by kiekie1(m): 9:17pm On Feb 06, 2019
Trueigbo:
I have a solar system of 2 panels, 100ah battery and 1kva inverter.

I have changed the inverter twice as the inverter gets damaged and stop giving output.

What should i do because i want to get another one.

Hello, feel free to chat us up ...
https:///2348170385620
Re: Solar Energy, A Complement To FTA by duwdu: 9:03am On Feb 07, 2019
NiyiOmoIyunade:
My Oga,

I believe that a surge arrestor cannot work effectively if it is not connected to a earth/ground point so that any fault current (surge) can be diverted safely to earth/ground. In fact having a surge arrestor in place with no earth/ground reference increases the risk of catastrophic equipment damage in the event of a surge.

To satisfy the requirements of item 11) "Grounding Instructions" and item 15) "Caution" per the screenshot below, you should simply connect the PV+ and PV- of Solar Panels from your Combiner box to the Inverter PV+ and PV- receptacles and connect the inverter's earth receptacle to your installation's permanent earth/ground point with suitably rated cables.

Install the surge protection device at the PV combiner box - connect positive of SPD to main trunk PV+ of combiner box and negative of SPD to the main trunk PV- of combiner box - it may help to use busbars in the combiner box and crimp heavy duty cable lugs (like the type used for battery cable connections) onto the Surge Protection Device's wires so this way you can torque everything down tightly onto the positive and negative busbars - the combiner box should have a 3rd busbar or wire terminal which is dedicated/already connected to central earth/ground for the installation. You must connect the 3rd wire (green earth wire) of the SPD to the combiner box earth bus bar or splice on suitable cable (crimp, do not twist wire together) so you can connect SPD directly to the central earth/ground point.

So in summary leave the actual solar panels ungrounded but ground the inverter, ground the combiner box, connect the SPD to combiner box main PV+ and PV- and definitely ground the SPD - if possible all devices should connect directly to central earth/ground but you may share thesame earth connection between combiner box and SPD.

If panels are more than 50 feet from the combiner box, you could also ground the panel mount frame/rack.

The ideal earth/ground point is a low resistance earth implemented with suitable rating, number and length of ground rods and suitably thick cables - use proper earthing chemicals where required and avoid the use of earths implemented with charcoal lumps and salt unless the charcoal has been grounded into fine powder and mixed thoroughly with suitable base materials to form a slurry.


This is reference material and has settled it comprehensively and quite neatly for me, NiyiOmoIyunade; much appreciated.

I will thus take my time to so set up this my impending upgrade before going live with it.

NiyiOmoIyunade:
I thought again that if budget is a constraint you could dispense with a combiner box and use a set of busbars to simulate a combiner box especially since your array is simply a set of panels in series and no parallel connections.

You would connect your panels in series as usual then run suitable gauge wire from PV + to DC Breaker (make sure breaker is rated for your high PV voltage) then from DC breaker to positive bus bar. The DC breaker allows you to isolate the array for inspection and maintenance - I would be very careful here that the breaker actually disconnects the PV as you definitely don't want to be zapped by 360vdc while attempting maintenance

But I digress....

You would connect the main PV- to a suitable gauge cable and run directly to the negative busbar. You should have free ports on the busbar to which you can now torque down your surge protection devices positive and negative cables (I still advise to crimp on cable lugs). The idea here is that you don't want to fit two cables (PV+ and SPD+) into your Inverter's PV+ terminal so that you have a firm mechanical and electrical connection (very key for lightning/surge diversion) and also to decommission the installation with minimal damage to cables.

The SPD's 3rd wire (green/earth) would then go to the installations central earth/ground point.

The busbars must be properly covered/isolated since they will be carrying dangerous DC voltages.


This too; thanks again.

........
P34c3
.....
...
Re: Solar Energy, A Complement To FTA by JUO(m): 10:38am On Feb 08, 2019
Flex max 80a fangpusun 155k
Flex max 60a fangpusun 130k
50a-12/24v 45k. 45k without display
50aD-12/24v 60k with display
60a-12/24v/36v/48v 100k. without display
60aD-12/24v/36v/48v 115k with display
70a-12/24v/36v/48v 110k without display
70a-12/24v/36v/48v 125k with display
45a-12/24v/36v/48v 70k without display
45a-12/24v/36v/48v 85k with display
30a-12/24v 33k
Battery balancer Fangpusun 24v-25k
Battery balancer HAO2 28k 12v/24v/48v
MPPT- CONTROL 16K
epever 30a 12/24v 40k
epever 40AN 12/24v 60k
BMV 702 FANGPUSUN 42K
Watts meter with clock and 50Hz/60Hz
Monitor Analyser 7k
PROGRAMMABLE Digital timer 15/16a 5k din rail
PROGRAMMABLE Digital timer 25a 7k din rail/wall mount
Ac/dc ceiling fan 56’ inches 5w to 36w
Solar water heater available
080-987-337-09
Re: Solar Energy, A Complement To FTA by GeorgeD1(m): 8:13pm On Feb 08, 2019
Namzy:
Is their anyone selling used 16mm2 cable for cheap? I'm asking for a friend. Thanks grin

i have some meters of red and black 16mm cables used in my last installation.
if interested you can pm me. but note however that it's not multi-strand and
the insulation has been scrapped in a few places (will require you applying the
usual black electrical insulation tape to make it good)
Re: Solar Energy, A Complement To FTA by earthrealm(m): 9:27pm On Feb 08, 2019
so am considering this outback 60amps. has been fairly low priced on amazon for sometime now. any known cons of this device??
only one i know is the internal fan stoping if dirty or clogged,

Outback FM60 Charge Controller
Re: Solar Energy, A Complement To FTA by earthrealm(m): 3:42pm On Feb 09, 2019
nonoski:
Finally finished my connections and powered the Outback Flexmax 80 Charge Controller and joined the club.

Thou I'm still confused about some of the readings

My set up for now is 12 nr 300watts panels (3600kw) in 3S4P connection and battery bank is 48v 200amps.

(I intent to add 3xtra panels to make it 15 panels and increase the battery bank size to 48v 400amps in the next few weeks)

Any cons of this CC?..180 usd price diff btw it n my beloved morning star....sorely tempted
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 4:36pm On Feb 09, 2019
Perhaps a 70k price difference but you will endure 10 to 20%
worse performance for the life of the CC - go with the MorningStar and be happy forever biko.

If you reach out, we may be able to help you close some of that $180 gap and deliver you an MS slightly below Amazon price.


earthrealm:


Any cons of this CC?..180 usd price diff btw it n my beloved morning star....sorely tempted
Re: Solar Energy, A Complement To FTA by Namzy(m): 5:53pm On Feb 09, 2019
GeorgeD1:


i have some meters of red and black 16mm cables used in my last installation.
if interested you can pm me. but note however that it's not multi-strand and
the insulation has been scrapped in a few places (will require you applying the
usual black electrical insulation tape to make it good)
Thanks your CONTACT number?
Re: Solar Energy, A Complement To FTA by Trippledots(m): 9:03pm On Feb 09, 2019
Anyone used or knw abt green power Deepcycle batteries? Abt acquiring two pcs. Urgent pls.. Thanks
Re: Solar Energy, A Complement To FTA by Nobody: 10:34pm On Feb 09, 2019
Hi...

I need a very cheap and durable solar device to just power my laptop consistently.

I live in a village with no electricity..

Where can I get one and what's ur advice??
Re: Solar Energy, A Complement To FTA by kiekie1(m): 12:40pm On Feb 10, 2019
DISCOUNTED PRICES - NUM 1 ONLINE STORE!!!

USA Magnum inverter 4124 ..... 930,000
USA Deka 210a battery .............190,000

Felicity 200a battery ...................90,000
Ritar 200a battery .......................115,000
Motoma 200a battery ................115,000
Cinemax 200a battery ................115,000
Cinemax 210a battery ................120,000

Morningstar 60a mppt ...............200,000
Morningstar 45a mppt................190,000
Tsm2 display ...............................60,000
Schneider 60a mppt ....................240,000

Battery equaliser 6-48v... 35,000 30,000

Epsolar Epever solar charge controllers
MT50 display ..................................15,000
Epever 12-24v 30a mppt ................50,000
Epever 12-24v 40a 4210N mppt ...........65,000
Epever 12-48v 60a itracer mppt....135,000

Epsolar PWM
30a 12-24v VS3024A .........30,000
45a 12-48v VS4548BN .......70,000
60a 12-48v VS6048AU .......80,000

Fangpusun MPPT
30a 12-24v .............................55,000
60a 12-48v mppt TR victron clone series ..125,000
60a 12-48v outback clone with display.......145,000
80a 12-48v mppt outback clone .................155,000

Must Power Star Light inverters with LCD display
1000w 12v=95k
1500w 12v=105k
3kva(2000w)-12v=115,000
4kva(3000w)-24v=155,000
5kva(4000w)-24/48=240,000
6kva(5000w)-24/48= 260,000
7.5kva(6000w)-24/48= 280,000

Keye 1.2kva/12v(without charger) 13,000
Keye 2.2kva/12v(without Charger) 18,000
Keye pure sinewave series
Keye 800va/12v 45,000
Keye 1.2kva/12v 55,000
Keye 3.5kva/24v 150,000
Keye 3.5kva/48v 150,000
Keye 5kva/24v 170,000
Keye 5kva/48v 170,000
Keye 7.5kva/48v 350,000
Keye 10kva/48v 370,000
Fangpusun 80a MPPT @ 155k
EP Solar 12/24/36/48v 60a mppt(i tracer) solar charge controller @ 135k
EP Solar 12/24v 40a MPPT solar charge controller @ 65k
Trojan 12v 200a J200re USA flooded batteries @ 129k...(limited quantity in stock)
Trojan 12v 205a agm batteries ... 165k
Trojan 6v 315a agm battery.... -------
Trojan 6v 375a agm battery ........ 170k
Trojay 6v 1225a flooded battery...485k
USA Deka 12v 210a .......190k
USA Mnspd 300 DC / AC ..... 50k
Schneider DC SPD ..........30k
AC/DC true RMS Clamp meters
UNI-T 203 ...N 20k
Suoer intelligent-automatic 30A 12V Battery Charger (MA-1230A) .... N 20k
DC display meters 0-30v...N 1600
DC display meters 0-120v..N 2200
ZHC Battery equalizer 12/24/36/48 volts..... 24k
Quanta Amaron 12v 200a vrla battery @ ...125k
Long 200a AGM batteries .... N120,000
Long 150a slim AGM battery..93,000
Long 100a AGM battery ........ 65,000
Long 100a carbon battery ..... 75,000
Superceed Batteries
12v 100ah= 40,000
12v 150ah= 60,000
12v 200ah= 80,000
Maximum power batteries
12v 100ah= 40,000
12v 150ah= 60,000
12v 200ah= 80,000
Double tech batteries
12v 100ah= 40,000
12v 150ah= 60,000
12v 200ah= 80,000
Network batteries
12v 110ah= 50,000
12v 180ah= 70,000
12v 210ah= 90,000
12v 250ah= 115,000
Flames 300w mono .... 47k
Watts meter "kill-a-watt meter" ....9k
Yachi solar panels ;
150w mono panels........@35k
260w mono panels.......@48k "limited stock"
310w mono panels........@59k "limited stock"

340w Solar world mono solar panels .... 78,000
Jinko 340w mono panel............70,000
Jinko 280w mono panel............57,000
Jinko 265w poly panel.............. 52,000
Trina solar 320w mono..............70,000
Trina solar 285w mono..............65,000
Era solar 300w mono.................58,000

DISCOUNTED PRICES ! CALL US NOW !!
Magnum 4348 USA inverter ....@900k
Victron multiplus 3kva 48v .....@600k
Schneider connect 2524..........@550k
Growatts SPF3000 plus hybrid/solar inverter...@295k
Growatts SPF 5000 hybrid/solar inverter... @325k
Canadian 340w mono solar panel"Korean cells" .... Offloading
Canadian 300w mono solar panel... 62,000
Canadian 330w mono solar panel.....@66,000 bulk price
Sunshine solar modules :
130w poly 23000
250w poly 39000
300w Mono 52,000
Quality chinese panels best price:
100w poly 18500
100w mono 19500
150w poly 23000
200w mono 33000
260w poly 35500
260w mono 39000
320w poly 45500

Mercury Industrial Stabilizer available now
10kva Single phase 100,000
15kva Single phase 157,000
20kva Single phase 195,000
30kva Single phase 300,000
15kva 3Phase in/out 195,000
30kva 3Phase in/out 320,000
50kva 3Phase in/out 830,000

Mercury Spirit Plus Hybrid Inverters are available now
2000 Spirit 2kva 120,000
2001 Spirit Plus 2kva 135,000
3001 Spirit Plus 3kva 165,000
5001 Spirit Plus 5kva 220,000
3kva Soho Inverter 185,000
5kva Soho Inverter 265,000
7.5kva Soho Inverter 300,000

BATTERIES
Mercury 1.2kva Inverter 40,000
Mercury 2.4kva Inverter 45,000
Mercury 200ah GEL battery 140,000
Mercury 200ah AGM battery 100,000
Mercury 100ah AGM battery 55,500

LUMINOUS BATTERIES:
Luminous 150AH/12V SMF .... 92k
Luminous 200AH/12V SMF .....115k
Luminous Blue 200AH/12V .....125k
Luminous tubular 220AH/12V..105k

LUMINOUS PURE SINEWAVE INVERTERS:
Luminous 850va/12v hybrid...52k
Luminous 875va/12v Eco.......37k
Luminous 1.5kva/24v Eco.......57k
Luminous 1.5kva/24v Zelio.....75k
Luminous 1.5kva/24v hybrid...80k
Luminous 3.5kva/48v Cruise..180k
Luminous 5kva/96v Cruise ....400k
Luminous 7.5kva/120v Cruise..500k
Luminous 10kva/180v ...........660k
Luminous 15kva/240v.............1m
Luminous 20kva/360v............ ----

BEST PRICES YOU CAN GET ON PRAG PRODUCTS !!!

Prag inverter 1kva 12v ......N65,000
Prag √√√√√ 1.2kva 12v....N70,000
Prag √√√√√ 2kva 24v.......N
Prag √√√√√ 1.5kva 24v....N92,000
Prag √√√√√ 2.5kva 24v....N95,000 "Promo"
Prag √√√√√ 1.5kva 24v....N96_000

Prag Solar inverter 1.5kva 24v....N120,000
Prag inverter 3kva 24v ....N145,000
Prag inverter 5kva 48v...N250,000
Prag inverter 7.5kva 120v ....N410,000
Prag inverter 10kva 180v....N480,000

Prag 4kva 24v wall H ......N240,000
Prag 6.5kva 48v wall H....N350,000


PRAG servo & relay stabilizers ;

-Prag 3kva relay B(95-280v)..N
-Prag 3kva relay E(95-280v)..N
-Prag 10kva servo ..N110,000
-Prag 10kva servo(130-250v)..N115,000
-Prag 12kva servo...N
-Prag 15kva relay(95-280v)...N110,000 "Promo"
-Prag 15kva servo(80-260v)..N220,000
-Prag 15kva servo(130-260v)..N190,000
-Prag 20kva servo(130-260v)...N230,000
-Prag 20kva relay cabinet(95-280v).. N150,000
-Prag 20kva servo(80-260v) ...N330,000
-Prag 30kva servo(80-260v)...N400,000
-Prag 30kva servo(1300-260v)..N380,000

Protek 200L solar water heater... N200,000
With 30k , I can offer you a set of pro solar roof mounts to comfortably mount 4 units of 250 to 350w solar panel's including kits like ;
2 qty solar mount rail "4200mm" ,
4 qty rack end clamp,
6 qty mid clamp,
6 qty L feet with rubber & special screw....
Same goes to angle positioning solar kits;
- Adjustable front leg
- Adjustable rear leg
- Rail splice kit
- Grounding lug


WHATSAPP::: https:///2348170385620

*AUTHORISED DEALER PRAGMATIC TECHNOLOGIES*
All our prag products comes with reliable warranty
*AUTHORIZED DEALER INDIAN INVERTERS / BATTERIES ... Luminous PRODUCTS*
All our products come with 1 year Warranty
*AUTHORIZED DEALER SOLAR SHOP LTD PRODUCTS*
All our products come with 1 year Warranty.
For best affordable prices contact,
The number 1 credible online store,
Smartcell Global Services,Lagos Nigeria.
Simply call Sir Frankie "08135031951" for purchase,fast delivery and waybills .. Thanks !!

Re: Solar Energy, A Complement To FTA by olopan(m): 12:56pm On Feb 10, 2019
Peterjosh:
Hi...

I need a very cheap and durable solar device to just power my laptop consistently.

I live in a village with no electricity..

Where can I get one and what's ur advice??

i can fix you up with an affordable solar power supply. Lookup my contact @ signature
Re: Solar Energy, A Complement To FTA by kiekie1(m): 1:20pm On Feb 10, 2019
Pretty dull weather today! Seeing less than 55-63a as usual. Ran heavy load overnight , doubt if Batteries wld float today shocked....

2 Likes 1 Share

Re: Solar Energy, A Complement To FTA by Saipro(m): 2:43pm On Feb 10, 2019
kiekie1:
Pretty dull weather today! Seeing less than 55-63a as usual. Ran heavy load overnight , doubt if Batteries wld float today shocked....
1.2kW instantaneous and you're complaining? My 3kW array hardly fares better understand the harmattan haze here; same array which generates 2.5kW during the monsoons
Re: Solar Energy, A Complement To FTA by Saipro(m): 3:05pm On Feb 10, 2019
The DC calibration on my 3kW 48V MustPower inverter has finally gone haywire. Showing 63.2V at a factual 57.0V absorb. It forces it to power down with an error 9. Over the years, it's been swinging between correct calibration to it's current absurd one.

I can lower absorb to 56.6V to make it usable but I've cracked out the spare Victron until I'm sure the MustPower won't burn down the house.

Any help?
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 7:31pm On Feb 10, 2019
This one of the reasons why I am considering forswearing MustPowers - their unreliability - the control boards are very delicate and prone to failure hence these days I would only touch the ones like Felicity with excellent customer service and an organised service center.

My current Red VilPower Star first stopped 'bypass' charging (charging while off) then started showing high voltage from the mains e.g 320v when mains was actually 220v (clean input from my servo stab) tired of the inverter, I simply routed the input through a contactor so I could bypass the battery whenever there was mains and that is still the arrangement I run until now.

Meanwhile the power board/inverter side is very rugged and pretty much bullet proof.

In your case the issue is likely the control board - a good tech at Alaba or Oshodi Arena may be able to fix it or perform a quick replacement for you.





Saipro:
The DC calibration on my 3kW 48V MustPower inverter has finally gone haywire. Showing 63.2V at a factual 57.0V absorb. It forces it to power down with an error 9. Over the years, it's been swinging between correct calibration to it's current absurd one.

I can lower absorb to 56.6V to make it usable but I've cracked out the spare Victron until I'm sure the MustPower won't burn down the house.

Any help?
Re: Solar Energy, A Complement To FTA by BRIGHTSOLAR(m): 9:09pm On Feb 10, 2019
ONLINE DELIVERY OF RENEWABLE ENERGY MATERIALS




INVERTER

MICROTECH INVERTER
900VA,12V N46,000
1.1KVA,12V N53,000
1.6KVA/24V N72,000
2KVA/24V N80,000
2.6KVA/36V N105,000
3.6KVA/48V N170,000
5.2KVA/48V N340,000.
5.5KVA/96V N340,000
10KVA/180V N790,000


PRAG INVERTER
1.1KVA,12V N70,000
1.2KVA,12V N90,000
1.5KVA/24V N110,000
2.5KVA/24V N125,000
4KVA/24V N270,000.
7.5KVA/120V N500,000

TRIBAL INVERTER

1.5KVA/24V N82,000
2.6KVA/36V N105,000
3.5KVA/48V N150,000
5KVA/48V N340,000.
5KVA/96V N340,000
10KVA/180V N750,000



MUST POWER STAR INVERTER

4kva 3000W 24V N 220,000
4kva 3000W 48V N 260,000
5kva 4000W 48V N 350,000
6kva 5000W 48V N 400,000
7.5kva 6000W 48V N 450,000
10kva/48V 8000W 48V N 950,000

KEYE INVERTER
KEYE 1.2KVA/12V - N54,000
KEYE 3.5KVA/24V - N180,000
KEYE 3.5KVA/48V - N180,000
KEYE 5KVA/24V – N275,000
KEYE 5KVA/48V -N 1275,000
KEYE 7.5KVA/48V – N400,000
KEYE 10KVA/48V – N6800,000



HYBRID INVERTER

VOLTRON SERIES
1.4KVA/12(30A N65,000
2.4KVA/24V50A N97,000
3KVA /48V 60A MPPT N220,000
5KVA /48V 60A MPPT N310,000
7.5KVA /48V 60A MPPT N430,000
10KVA /48V 100A MPPT N750,000
15KVA /48V 60A MPPT N850,000
15KVA /48V 120A MPPT N890,000


GENEXTECH SERIES

2KVA/24V(600W MPPT) #138,000
3KVA/24V(600W MPPT) #149,000
3KVA/24V(1500W MPPT) #194,000
3KVA/48V(3000W MPPT) #202,000
5KVA/48V(3000W MPPT) #306,000
10KW/48V(14850W MPPT) #1,660,000


STABILIZER

VOLTRON STABLIZER
6KVA WALL MOUNT RELAY REGULATOR #45,000
6KVA WALL MOUNT SERVO REGULATOR #65,000
12KVA WALL MOUNT RELAY REGULATOR #90,000
12KVA WALL MOUNT SERVO REGULATOR #120,000


PRAG STABLIZER

10KVA WALL MOUNT SERVO REGULATOR #130,000
12KVA WALL MOUNT RELAY REGULATOR #120,000
15KVA WALL MOUNT RELAY REGULATOR #140,000
15KVA WALL MOUNT SERVO REGULATOR #240,000
20KVA RELAY REGULATOR #195,000
20KVA SERVO REGULATOR #370,000
30KVA SERVO REGULATOR #470,000


BATTERY

GENEX BATTERY 12V/200AH N 120,000
LONG BATTERY 12V/200AH N 120,000
MONBAT BATTERY 12V/200AH N 125,000
MONBAT BATTERY 12V/210AH N 120,000
ELSON BATTERY 12V/200AH N 115,000
MICROTEC BATTERY 12V/200AH N 105,000
M POWER BATTERY 12V/200AH N 115,000
EASTMAN 12V/200AH TALL TUBULAR BATTERY N115,000
GLT BATTERY 12V/200AH N 90,000
ZEEDIX BATTERY 12V/200AH N 95,000
RITAR BATTERY 12V/200AH N 130,000
PRAG BATTERY 12V/200AH N 140,000
PATTERN BATTERY 12V/200AH N100,000
QUANTA BATTERY 12V/200AH N 130,000


BATTERY RACK
BATTERY RACK 2 BATTERY N 15,000
BATTERY RACK 4 BATTERIES N 30,000
BATTERY RACK 8 BATTERIES N 50,000


CHARGE CONTROLLER
ROY SOLAR SERIES
20A 12/24V PWM CONTROLLER N 20,000
30A 12/24V PWM CONTROLLER N 25,000
40A 48v PWM controller (LED) N 50,000
30A 96v PWM controller (LCD) N 120,000
60A 48v PWM controller (LCD) N 95,000


COWIN SERIES
20A 12/24V PWM CONTROLLER N 15,000
30A 12/24V PWM CONTROLLER N 20,000
40A 12/24V PWM CONTROLLER N 25,000
50A 12/24V PWM CONTROLLER N 32,000
60A 12/24V PWM CONTROLLER N 41,000
40A 48v PWM controller (LED) N 25,000
50A 48v PWM controller (LED) N 32,000
60A 48v PWM controller (LED) N 50,000

COWIN MPPT SERIES

40A 12/24/48v MPPT controller (LCD) N 80,000
60A 12/24/48V MPPT controller (LCD) N 130,000

EPEVER MPPT SERIES
12/24/48 /45A N 145,000
12/24/48 /60A N165,000

DIAMOND MPPT
60A 12/24/36/48VOLT N115,000

FANGUNPSUN MPPT SERIES
30A 24V N40,000
60A 48v N140,000
80A 48v N170,000

SOLAR PANELS

JOY SOLAR PANEL
150w MONO -N32,000
200w MONO -N33,000
260w MONO -N54,000


150w POLY –N27,000
200w POLY -N31,000
260w POLY -N52,000

TRINA SOLAR PANEL

300w MONO -N85,000
320w MONO -N110,000


YINGLIN SOLAR PANEL
100w POLY -N22,000
150w POLY -N33,000
200w POLY -N39,000
260w POLY -N51,000
310w POLY -N62,000


100w MONO-N25,000
150w MONO -N33,000
200w MONO -N39,000
260w MONO -N59,000
320w MONO -N74,000

JINKO SOLAR PANEL
JINKO SOLAR 370WATT MONO - N80,000
JINKO SOLAR 340WATT MONO - N70,000
JINKO SOLAR 280WATT MONO - N57,000
JINKO SOLAR 265WATT POLY - N55,000

CANADIAN SOLAR PANEL

MONO-
290w. N60,000 (BULK PURCHASE ONLY)
330w. N66,000 (BULK PURCHASE ONLY)

POLY
270w. N45,000 (BULK PURCHASE ONLY)
275w. N59,000 (BULK PURCHASE ONLY)

ACCESSORIES

PROGRAMMABLE Digital timer 15A N7,000
PROGRAMMABLE Digital timer 25A N9,000


BATTERY BALANCER /EQUALIZER 48V 35,000
BATTERY BALANCER EQUALIZER 24V #30,000
BATTERY VOLTMETER INDICATOR #1,700


DC CIRCUIT BREAKER 63A/120V---500V 2 POLE N 8,000
DC CIRCUIT BREAKER 125A/500V 2 POLE N 14,000



DC IRON 150WATTS #9,000


COMPLETE SOLAR SOLUTION


Call-07058562938 Bright Solar Power

WHATSSAP 08187995847

FOR PURCHASE/ DELIVERY /INSTALLATION NATIONWIDE

https:///send?phone=2348187995847



visit our updated website


www.brightsenergy.com
Re: Solar Energy, A Complement To FTA by ola28: 9:59pm On Feb 10, 2019
Hello house, 3 pieces of USED YINGLIN 300w poly solar panel available for sale

35k each


09057285592
Re: Solar Energy, A Complement To FTA by Jiteshell(f): 10:04pm On Feb 10, 2019
Hey guys..

So I'm not a DIY person when it comes to stuff like this.
What I'm concerned about is powering a freezer (see pics attached for wattage info and stuff) for about 10 hours everyday with solar.

I would also like if it can power my laptop for that same amount of time.

For those into stuff like this, can I get an estimated cost for without the laptop and with it? I know laptops don't need lots of power...but just saying.

So solar + inverter...hybrid system preferably...

Re: Solar Energy, A Complement To FTA by kiekie1(m): 10:13pm On Feb 10, 2019
kiekie1:
A unit of fairly used Emerson 24v 60a bulk charger module up for sale ...#20k

Contact,
Smartcellglobal
081-350-31951

SOLD
Re: Solar Energy, A Complement To FTA by kiekie1(m): 10:16pm On Feb 10, 2019
Saipro:

1.2kW instantaneous and you're complaining? My 3kW array hardly fares better understand the harmattan haze here; same array which generates 2.5kW during the monsoons


Haha was jst a bit worried about today's weather Sir cheesy
Re: Solar Energy, A Complement To FTA by earthrealm(m): 6:56am On Feb 11, 2019
Jiteshell:
Hey guys..

So I'm not a DIY person when it comes to stuff like this.
What I'm concerned about is powering a freezer (see pics attached for wattage info and stuff) for about 10 hours everyday with solar.

I would also like if it can power my laptop for that same amount of time.

For those into stuff like this, can I get an estimated cost for without the laptop and with it? I know laptops don't need lots of power...but just saying.

So solar + inverter...hybrid system preferably...

120w x 10hrs = 1200w
,min batt config i wud recommend is 2 units of 12v 200ah,
min panels i wud recommend is 1000w/900w 4 x 250w, 3 x 300w, 3 x 330w etc
laptop takes 40 to 80w depending on size, and once that batt is fully charged, its consumption drops to below 40w, so its negligible

250w cost = 35k to 65k..depending on type/make
12v 200ah cost btw 90k to 140k depending

a good 1.5kva inverter can power your load, but if the your budget is a lil freer, go for a 2,4kva
check the prices from our vendors here....that shud give you an idea of budget.
you can also keep 30k to 80k for logistics/labour/other ancillary items you might need

3 Likes

Re: Solar Energy, A Complement To FTA by duwdu: 8:36am On Feb 11, 2019
earthrealm:


120w x 10hrs = 1200w
,min batt config i wud recommend is 2 units of 12v 200ah,
min panels i wud recommend is 1000w/900w 4 x 250w, 3 x 300w, 3 x 330w etc
laptop takes 40 to 80w depending on size, and once that batt is fully charged, its consumption drops to below 40w, so its negligible

250w cost = 35k to 65k..depending on type/make
12v 200ah cost btw 90k to 140k depending

a good 1.5kva inverter can power your load, but if the your budget is a lil freer, go for a 2,4kva
check the prices from our vendors here....that shud give you an idea of budget.
you can also keep 30k to 80k for logistics/labour/other ancillary items you might need

As a "newly launched" renewable energy DIYer myself, I make bold to say the quoted post by earthrealm is as good and pragmatic an advice as it gets, Jiteshell.

Good luck.

........
P34c3
.....
...

1 Like

(1) (2) (3) ... (500) (501) (502) (503) (504) (505) (506) ... (1853) (Reply)

FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread

Viewing this topic: adrusa

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 114
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.