Re: Solar Energy, A Complement To FTA by duwdu: 12:44pm On Apr 27, 2019
bigrovar:


welcome to the club bro. The system I setup some times in july last year is still running and has been logging away without issues. Even when I am out of the country, I can still always take a peep and see what is happening. Using the solar equipment with open communication port and documentations (Looking at Victron and to some extent some tracer and epsolar devices) is also very important if you are considering going this route.

I've been a fan of your dashboard for several months from last year already, actually; it's so functional and pretty and was partly where I got my inspiration, so thanks. My post was geared more towards novices to visualization resources such as yours truly.

Quashie proprietory visualization and data logging interfaces come with my current budget and so far robust components by MPP Solar. I had also during last year tried my hands on building dashboards based on Grafana/Chronograf and the like for use with the PCM60x (attached,) but later slacked off so I'm learning.

Now my mind is further energized as I delve further into the Pi 3 ...

That being said, I'd still love to build something similar to your dashboard if you'll please share your processes/code with me? My new frontline PIP5048 is also Axpert/Voltronic based, although I'm yet to fully deploy it.

........
P34c3
.....
...

Re: Solar Energy, A Complement To FTA by viazi: 1:31pm On Apr 27, 2019
Greetings my gurus, am a newbie. Pls I have a question. I have the following. Must EP3000PRO 24V, One-solar 60a MPPT, 6 Pieces Poly Panels of 250w each. My question is this if I install all these with 2 pieces 200ah batteries, wont the grid and the Solar be charging my batteries the same time? My inverter is not hybrid. How do I resolve this issue?
Re: Solar Energy, A Complement To FTA by bigrovar(m): 4:44pm On Apr 27, 2019
duwdu:


I've been a fan of your dashboard for several months from last year already, actually; it's so functional and pretty and was partly where I took my inspiration from, so thanks. My post was geared more towards novices to visualization resources such as yours truly.

And aside from vizualization and data logging interfaces provided by my current budget and so far robust components by MPP Solar, I had also last year tried my hands on building dashboards based on Grafana/Chronograf and the like (attached,) but later slacked off; so I'm learning.

That being said, I'd still love to build something similar to your dashboard if you'll please share your processes/code with me? My new frontline PIP5048 is also Axpert/Voltronic based, although I'm yet to fully deploy it.

........
P34c3
.....
...

If I am not mistaken the system you are monitoring is the axpert inverter? which communication media are you using? The supplied usb connection cable? I asked because that cable driver is an issue and I was only able to get it to work by treating it as a hardware input device and the hack was not that easy. How did you do the connection in your case?
Re: Solar Energy, A Complement To FTA by Nobody: 4:57am On Apr 28, 2019
makavele:


The only wire I can see with my "novice" eyes coming out the opposite direction is the inverter negative cable . . .
please clarify more and i,ll see if it is fix-worthy
are you talking bout the blue and yellow wires (battery to bus bar cables)
i doubt so. once again clarify, until then, peace out
Lols.
When did you park from your bridge?
Re: Solar Energy, A Complement To FTA by BRIGHTSOLAR(m): 9:32am On Apr 28, 2019
ONLINE DELIVERY OF RENEWABLE ENERGY MATERIALS

INVERTER

MICROTECH INVERTER
900VA,12V N46,000
1.1KVA,12V N53,000
1.6KVA/24V N72,000
2KVA/24V N80,000
2.6KVA/36V N105,000
3.6KVA/48V N170,000
5.2KVA/48V N340,000.
5.5KVA/96V N340,000
10KVA/180V N790,000


PRAG INVERTER
1.1KVA,12V N70,000
1.2KVA,12V N90,000
1.5KVA/24V N110,000
2.5KVA/24V N125,000
4KVA/24V N270,000.
7.5KVA/120V N500,000

LUMINOUS INVERTER

1.5KVA/24V N58,000
2.6KVA/36V N105,000
3.5KVA/48V N210,000
5KVA/48V N340,000.
5KVA/96V N340,000
10KVA/180V N750,000



MUST POWER STAR INVERTER

4kva 3000W 24V N 220,000
4kva 3000W 48V N 260,000
5kva 4000W 48V N 350,000
6kva 5000W 48V N 400,000
7.5kva 6000W 48V N 450,000
10kva/48V 8000W 48V N 950,000

KEYE INVERTER
KEYE 1.2KVA/12V - N54,000
KEYE 3.5KVA/24V - N180,000
KEYE 3.5KVA/48V - N180,000
KEYE 5KVA/24V – N275,000
KEYE 5KVA/48V -N 1275,000
KEYE 7.5KVA/48V – N400,000
KEYE 10KVA/48V – N6800,000



HYBRID INVERTER

VOLTRON SERIES
1.4KVA/12(30A N65,000
2.4KVA/24V50A N97,000
3KVA /48V 60A MPPT N220,000
5KVA /48V 60A MPPT N310,000
7.5KVA /48V 60A MPPT N430,000
10KVA /48V 100A MPPT N750,000
15KVA /48V 60A MPPT N850,000
15KVA /48V 120A MPPT N890,000


GENEXTECH SERIES

2KVA/24V(600W MPPT) #138,000
3KVA/24V(600W MPPT) #149,000
3KVA/24V(1500W MPPT) #194,000
3KVA/48V(3000W MPPT) #202,000
5KVA/48V(3000W MPPT) #306,000
10KW/48V(14850W MPPT) #1,660,000


STABILIZER

VOLTRON STABLIZER
6KVA WALL MOUNT RELAY REGULATOR #45,000
6KVA WALL MOUNT SERVO REGULATOR #65,000
12KVA WALL MOUNT RELAY REGULATOR #90,000
12KVA WALL MOUNT SERVO REGULATOR #120,000


PRAG STABLIZER

10KVA WALL MOUNT SERVO REGULATOR #130,000
12KVA WALL MOUNT RELAY REGULATOR #120,000
15KVA WALL MOUNT RELAY REGULATOR #140,000
15KVA WALL MOUNT SERVO REGULATOR #240,000
20KVA RELAY REGULATOR #195,000
20KVA SERVO REGULATOR #370,000
30KVA SERVO REGULATOR #470,000


BATTERY

LUMINIOUS BATTERY 12V/200AH N 125,000
LONG BATTERY 12V/200AH N 120,000
MONBAT BATTERY 12V/200AH N 125,000
ELSON BATTERY 12V/200AH N 115,000
MICROTEC BATTERY 12V/200AH N 105,000
M POWER BATTERY 12V/200AH N 115,000
EASTMAN 12V/200AH TALL TUBULAR BATTERY N115,000
GLT BATTERY 12V/200AH N 90,000
ZEEDIX BATTERY 12V/200AH N 95,000
RITAR BATTERY 12V/200AH N 130,000
PRAG BATTERY 12V/200AH N 140,000
GENUS BATTERY 12V/200AH N125,000
RITAR 200A BATTERY .......................N 115,000
MOTOMA 200A BATTERY ................N 120,000
CINEMAX 200A BATTERY ................N 120,000
QUANTA BATTERY 12V/200AH N 140,000
ALIGRAND 200A BATTERY ................N 120,000
NPP 200A BATTERY ................N 120,000


BATTERY RACK
BATTERY RACK 2 BATTERY N 15,000
BATTERY RACK 4 BATTERIES N 30,000
BATTERY RACK 8 BATTERIES N 50,000


CHARGE CONTROLLER

ROY SOLAR SERIES
20A 12/24V PWM CONTROLLER N 20,000
30A 12/24V PWM CONTROLLER N 25,000
40A 48v PWM controller (LED) N 50,000
30A 96v PWM controller (LCD) N 120,000
60A 48v PWM controller (LCD) N 95,000


COWIN SERIES
20A 12/24V PWM CONTROLLER N 15,000
30A 12/24V PWM CONTROLLER N 20,000
40A 12/24V PWM CONTROLLER N 25,000
50A 12/24V PWM CONTROLLER N 32,000
60A 12/24V PWM CONTROLLER N 41,000
40A 48v PWM controller (LED) N 25,000
50A 48v PWM controller (LED) N 32,000
60A 48v PWM controller (LED) N 50,000

COWIN MPPT SERIES

40A 12/24/48v MPPT controller (LCD) N 80,000
60A 12/24/48V MPPT controller (LCD) N 130,000

EPEVER MPPT SERIES
12/24/48 /45A N 145,000
12/24/48 /60A N155,000

SRNE MPPT
12/24/36/48V/60A N115,000

FANGUNPSUN MPPT SERIES
30A 24V N40,000
60A 48v N140,000
80A 48v N170,000

SOLAR PANELS

JOY SOLAR PANEL
150w MONO -N32,000
200w MONO -N33,000
260w MONO -N54,000


150w POLY –N27,000
200w POLY -N31,000
260w POLY -N52,000

TRINA SOLAR PANEL

300w MONO -N85,000
350w MONO -N110,000


YINGLIN SOLAR PANEL
100w POLY -N22,000
150w POLY -N33,000
200w POLY -N39,000
260w POLY -N51,000
310w POLY -N62,000


100w MONO-N25,000
150w MONO -N33,000
200w MONO -N39,000
260w MONO -N59,000
320w MONO -N74,000

JINKO SOLAR PANEL
JINKO SOLAR 370WATT MONO - N80,000
JINKO SOLAR 340WATT MONO - N70,000
JINKO SOLAR 280WATT MONO - N57,000
JINKO SOLAR 265WATT POLY - N55,000

ERA SOLAR PANEL
ERA SOLAR 300WATT MONO – N56,000
ERASOLAR 370WATT MONO - N72,000


CANADIAN SOLAR PANEL

MONO-
300w. N52,000 (BULK PURCHASE ONLY)
330w. N54,000 (BULK PURCHASE ONLY)

POLY
270w. N48,000 (BULK PURCHASE ONLY)


ACCESSORIES

PROGRAMMABLE Digital timer 15A N7,000
PROGRAMMABLE Digital timer 25A N9,000


BATTERY BALANCER /EQUALIZER 48V -------------35,000
BATTERY BALANCER EQUALIZER 24V ---------------#30,000
BATTERY VOLTMETER INDICATOR ------------------#1,700

DC SURGE ARRESTOR 800VDC------------------------------------N26,000



INSTALLATION KITS
L.FOOT N1,000 (MINIMUM ORDER 10 PIECES)
MID CLAMP N1,000 (MINIMUM ORDER 10 PIECES)
END CLAMP N1,000 (MINIMUM ORDER 10 PIECES)


DC IRON 150WATTS #9,000


COMPLETE SOLAR SOLUTION
Call-07058562938 Bright Solar Power

WHATSSAP 08187995847

FOR PURCHASE/ DELIVERY /INSTALLATION NATIONWIDE

https:///send?phone=2348187995847

visit our updated website

www.brightsenergy.com

Re: Solar Energy, A Complement To FTA by kiekie1(m): 12:55pm On Apr 28, 2019
Happy Sunday all ! The weather has been pretty dull these few days but solar all the way smiley

Smartcellglobal services
081-350-31951
WHATSAPP::: https:///2348170385620

1 Like 1 Share

Re: Solar Energy, A Complement To FTA by Saipro(m): 4:29pm On Apr 28, 2019
duwdu:
The Raspberry Pi 3 Model B is an incredible, nifty machine and is truly affordable. These will have to partially explain why many arrays of developers favour it so much as a platform of choice for apps and IoT stuff, majorly of the open-source types.

In this case, attached are four screen shots of the SolarSnoop/PCM60X Monitor app on the Pi, by a developer and in use with my charge controller. It's freely available on GitHub. It uses a browser interface and is thus available to be interacted with within the range of a WiFi network, or from anywhere on the Internet, on a browser.

I set up this my own particular install of the PCM60X Monitor to auto-refresh every minute, which interval is good enough for me.

Hope some of us who are not already using equivalent or better solutions to monitor/visualize their RE set ups, will be encouraged to find similar ones for own use.

........
P34c3
.....
...

I'd like to have something like this for the Midnites too. Sadly, the closest I came was with an Android App (though there's some German Raspberry Pi compiles which seem to work just fine).
Re: Solar Energy, A Complement To FTA by duwdu: 6:42pm On Apr 28, 2019
bigrovar:


If I am not mistaken the system you are monitoring is the axpert inverter? which communication media are you using? The supplied usb connection cable? I asked because that cable driver is an issue and I was only able to get it to work by treating it as a hardware input device and the hack was not that easy. How did you do the connection in your case?

The component I'm monitoring and have shown is just my PCM60x CC so far and it is a Voltronic/MPPSolar product. It is coupled with a VIL Star-Light Power Inverter. Like I said, I'm yet to deploy my Axpert/Voltronic based PIP5048GK.

The com cable supplied with the CC (and also one of the cables that come with the PIP) is ethernet/RJ45-to-RS232. Based on what I learnt from MPP Solar and on other forums (chiefly secondlifestorage - yeah, I once saw one bigrovar post on there, hehehe) I then got a RS232-to-USB converter from Amazon. It has worked like a charm to seamlessly interface the CC with my PC/Pi via USB. I don't have the particular link handy, but the trick is to get one with a Prolific chip. Appropriate Prolific drivers are auto installed on Linux. For Windoze, they're available on Prolific's website.

(BTW, I also tried the RJ45-to-USB cable sold for EPSolar/Ever products but that did not work for me.)

........
P34c3
.....
...
Re: Solar Energy, A Complement To FTA by mank1234(m): 8:42pm On Apr 28, 2019
How can I achieve the scenerio below :
Make a device to come on only when instantaneous energy from a solar array reaches 1500W and then goes off when it falls below 500W?

2 Likes

Re: Solar Energy, A Complement To FTA by bigrovar(m): 9:22pm On Apr 28, 2019
duwdu:


The component I'm monitoring and have shown is just my PCM60x CC so far and it is a Voltronic/MPPSolar product. It is coupled with a VIL Star-Light Power Inverter. Like I said, I'm yet to deploy my Axpert/Voltronic based PIP5048GK.

The com cable supplied with the CC (and also one of the cables that come with the PIP) is ethernet/RJ45-to-RS232. Based on what I learnt from MPP Solar and on other forums (chiefly secondlifestorage - yeah, I once saw one bigrovar post on there, hehehe) I then got a RS232-to-USB converter from Amazon. It has worked like a charm to seamlessly interface the CC with my PC/Pi via USB. I don't have the particular link handy, but the trick is to get one with a Prolific chip. Appropriate Prolific drivers are auto installed on Linux. For Windoze, they're available on Prolific's website.

(BTW, I also tried the RJ45-to-USB cable sold for EPSolar/Ever products but that did not work for me.)

........
P34c3
.....
...

Thanks for the update.
Re: Solar Energy, A Complement To FTA by Barezzi(m): 10:57am On Apr 29, 2019
Can you expatiate on what you tryna do?

I'm not sure you can do this, and it's not a good parameter to use for control.
You can produce instantaneous power of 1.5Kw, but only 200w reach the batteries.

Consider using the battery Voltage or SOC for your control system.

mank1234:
How can I achieve the scenerio below :
Make a device to come on only when instantaneous energy from a solar array reaches 1500W and then goes off when it falls below 500W?

2 Likes

Re: Solar Energy, A Complement To FTA by pranil(m): 12:48pm On Apr 29, 2019
mank1234:
How can I achieve the scenerio below :
Make a device to come on only when instantaneous energy from a solar array reaches 1500W and then goes off when it falls below 500W?

Not unless you have faily advanced systems like Victron, SMA or fronius which allow programming of auxiliary relays

4 Likes

Re: Solar Energy, A Complement To FTA by CAROLYN19: 3:09pm On Apr 29, 2019
Do you need quality Industrial Power Back up, call/watsapp us on 08066332919

Re: Solar Energy, A Complement To FTA by bigrovar(m): 5:54pm On Apr 29, 2019
Barezzi:
Can you expatiate on what you tryna do?

I'm not sure you can do this, and it's not a good parameter to use for control.
You can produce instantaneous power of 1.5Kw, but only 200w reach the batteries.

Consider using the battery Voltage or SOC for your control system.


Bro. How area. Abeg ping me backstage i lost your number during a phone swap.

1 Like

Re: Solar Energy, A Complement To FTA by NairaBaba: 9:10pm On Apr 29, 2019
pranil:


Not unless you have faily advanced systems like Victron, SMA or fronius which allow programming of auxiliary relays

It can easily be achieved if voltage is use as the signal instead of power. I currently have a system that uses the battery voltage as the signal to active a low/high disconnect monitoring Relay which in turn activate or de-activate contactors. These contactors control selected loads such fridge, ACs, sockets etc

1 Like

Re: Solar Energy, A Complement To FTA by CNN80: 10:14pm On Apr 29, 2019
Hello Niyi,

I was hoping you could help me out as you know a lot about batteries.

I want to install a 5kVA solar PV system at home. I have had offers for regular lead acid batteries, tubular batteries and lithium ion batteries (GSL Powerwall). I want to know what you think is a good option for me.

Setup wise, I've had the following offers

12 Solar Panels (24V, 250W); 8 batteries (12V, 150A)

20 Solar Panels (24V, 250W); 10 batteries (200Ah)/12 batteries (150Ah)

16 Solar Panels (250W); 8 batteries (220Ah)

According to my estimates, the fridges use 450W, the TV 100W, the ACs 1472W, the Fans 375W, the Bulbs 135W and the Laptop 60 W.

We are moving house so the plan is to cut down on our energy use. Consequently, I'm hoping to wire the house in such a way that when the inverter is receiving power from the panel or grid, everything can be put on but when the inverter is drawing power from the batteries, only essential power points will be available.

I've been reading some of your posts and would really appreciate your input.

Thanks



NiyiOmoIyunade:
I agree with these broad conclusions but 500 cycles for Quanta would imply end users get less than 2 years life at 50% DoD per day.

To throw in some real life into all these spec sheets;

I have actual field data from at least 100 12v 200Ah batteries I have installed - a good number of them have already passed the 2 year mark and still going strong - this with users who don't even know what DoD means or respect DoD.

I can only conclude that the Quanta manufacturer estimates are overly conservative or the battery capacity is understated.

Oga Dapsyra gave some hard field data for his LTO batteries over a 15month period - I look to similar field data for the BattleBorns instead of just projected lab results.

I do not think it is practical to use a 100% DoD assumption for any battery bank with more than one battery connected in series except the battery capacity was understated.

I would really love a LTO or similar bank to play with but the entry cost is rather steep - sad to say I 'd rather replace my Quanta 3 times over a 10 year period than throw 10 million naira into a Lithium battery bank and hope for a 10 year lifespan without field evidence to back me up.

Nearly 80% of the Lithium reviews I come across tell me people are still trying to gain mastery of this Lithium tech.


Re: Solar Energy, A Complement To FTA by kiekie1(m): 6:17am On Apr 30, 2019
DISCOUNTED PRICES - NUM 1 ONLINE STORE!!!

USA Magnum inverter 4124 ..... 930,000
USA Deka 210a battery .............190,000

Felicity 200a battery ...................90,000
Ritar 200a battery .......................115,000
Motoma 200a battery ................115,000
Cinemax 200a battery ................115,000
Cinemax 210a battery ................120,000

Morningstar 60a mppt ...............200,000
Morningstar 45a mppt................190,000
Tsm2 display ...............................60,000
Schneider 60a mppt ....................240,000

Battery equaliser 6-48v... 35,000 30,000

Epsolar Epever solar charge controllers
MT50 display ..................................15,000
Epever 12-24v 30a mppt ................50,000
Epever 12-24v 40a 4210N mppt ...........65,000
Epever 12-48v 60a itracer mppt....135,000

Epsolar PWM
30a 12-24v VS3024A .........30,000
45a 12-48v VS4548BN .......70,000
60a 12-48v VS6048AU .......80,000

Fangpusun MPPT
30a 12-24v .............................55,000
60a 12-48v mppt TR victron clone series ..125,000
60a 12-48v outback clone with display.......145,000
80a 12-48v mppt outback clone .................155,000

Must Power Star Light inverters with LCD display
1000w 12v=95k
1500w 12v=105k
3kva(2000w)-12v=115,000
4kva(3000w)-24v=155,000
5kva(4000w)-24/48=240,000
6kva(5000w)-24/48= 260,000
7.5kva(6000w)-24/48= 280,000

Keye 1.2kva/12v(without charger) 13,000
Keye 2.2kva/12v(without Charger) 18,000
Keye pure sinewave series
Keye 800va/12v 45,000
Keye 1.2kva/12v 55,000
Keye 3.5kva/24v 150,000
Keye 3.5kva/48v 150,000
Keye 5kva/24v 230,000
Keye 5kva/48v 250,000
Keye 7.5kva/48v 350,000
Keye 10kva/48v 370,000
Fangpusun 80a MPPT @ 155k
EP Solar 12/24/36/48v 60a mppt(i tracer) solar charge controller @ 135k
EP Solar 12/24v 40a MPPT solar charge controller @ 65k
Trojan 12v 200a J200re USA flooded batteries @ 129k...(limited quantity in stock)
Trojan 12v 205a agm batteries ... 165k
Trojan 6v 315a agm battery.... -------
Trojan 6v 375a agm battery ........ 170k
Trojay 6v 1225a flooded battery...485k
USA Deka 12v 210a .......190k
USA Mnspd 300 DC / AC ..... 50k
Schneider DC SPD ..........30k
AC/DC true RMS Clamp meters
UNI-T 203 ...N 20k
Suoer intelligent-automatic 30A 12V Battery Charger (MA-1230A) .... N 20k
DC display meters 0-30v...N 1600
DC display meters 0-120v..N 2200
ZHC Battery equalizer 12/24/36/48 volts..... 24k
Quanta Amaron 12v 200a vrla battery @ ...125k
Long 200a AGM batteries .... N120,000
Long 150a slim AGM battery..93,000
Long 100a AGM battery ........ 65,000
Long 100a carbon battery ..... 75,000
Superceed Batteries
12v 100ah= 40,000
12v 150ah= 60,000
12v 200ah= 80,000
Maximum power batteries
12v 100ah= 40,000
12v 150ah= 60,000
12v 200ah= 80,000
Double tech batteries
12v 100ah= 40,000
12v 150ah= 60,000
12v 200ah= 80,000
Network batteries
12v 110ah= 50,000
12v 180ah= 70,000
12v 210ah= 90,000
12v 250ah= 115,000
Flames 300w mono .... 47k
Watts meter "kill-a-watt meter" ....9k
Yachi solar panels ;
150w mono panels........@35k
260w mono panels.......@48k "limited stock"
310w mono panels........@59k "limited stock"

340w Solar world mono solar panels .... 78,000
Jinko 340w mono panel............70,000
Jinko 280w mono panel............57,000
Jinko 265w poly panel.............. 52,000
Trina solar 320w mono..............70,000
Trina solar 285w mono..............65,000
Era solar 300w mono.................58,000

DISCOUNTED PRICES ! CALL US NOW !!
Magnum 4348 USA inverter ....@900k
Victron multiplus 3kva 48v .....@600k
Schneider connect 2524..........@550k
Growatts SPF3000 plus hybrid/solar inverter...@295k
Growatts SPF 5000 hybrid/solar inverter... @325k
Canadian 340w mono solar panel"Korean cells" .... Offloading
Canadian 300w mono solar panel... 62,000
Canadian 330w mono solar panel.....@66,000 bulk price
Sunshine solar modules :
130w poly 23000
250w poly 39000
300w Mono 52,000
Quality chinese panels best price:
100w poly 18500
100w mono 19500
150w poly 23000
200w mono 33000
260w poly 35500
260w mono 39000
320w poly 45500

Mercury Industrial Stabilizer available now
10kva Single phase 100,000
15kva Single phase 157,000
20kva Single phase 195,000
30kva Single phase 300,000
15kva 3Phase in/out 195,000
30kva 3Phase in/out 320,000
50kva 3Phase in/out 830,000

Mercury Spirit Plus Hybrid Inverters are available now
2000 Spirit 2kva 120,000
2001 Spirit Plus 2kva 135,000
3001 Spirit Plus 3kva 165,000
5001 Spirit Plus 5kva 220,000
3kva Soho Inverter 185,000
5kva Soho Inverter 265,000
7.5kva Soho Inverter 300,000

BATTERIES
Mercury 1.2kva Inverter 40,000
Mercury 2.4kva Inverter 45,000
Mercury 200ah GEL battery 140,000
Mercury 200ah AGM battery 100,000
Mercury 100ah AGM battery 55,500

LUMINOUS BATTERIES:
Luminous 150AH/12V SMF .... 92k
Luminous 200AH/12V SMF .....115k
Luminous Blue 200AH/12V .....125k
Luminous tubular 220AH/12V..105k

LUMINOUS PURE SINEWAVE INVERTERS:
Luminous 850va/12v hybrid...52k
Luminous 875va/12v Eco.......37k
Luminous 1.5kva/24v Eco.......57k
Luminous 1.5kva/24v Zelio.....75k
Luminous 1.5kva/24v hybrid...80k
Luminous 3.5kva/48v Cruise..180k
Luminous 5kva/96v Cruise ....400k
Luminous 7.5kva/120v Cruise..500k
Luminous 10kva/180v ...........660k
Luminous 15kva/240v.............1m
Luminous 20kva/360v............ ----

BEST PRICES YOU CAN GET ON PRAG PRODUCTS !!!

Prag inverter 1kva 12v ......N65,000
Prag √√√√√ 1.2kva 12v....N70,000
Prag √√√√√ 2kva 24v.......N
Prag √√√√√ 1.5kva 24v....N92,000
Prag √√√√√ 2.5kva 24v....N95,000 "Promo"
Prag √√√√√ 1.5kva 24v....N96_000

Prag Solar inverter 1.5kva 24v....N120,000
Prag inverter 3kva 24v ....N145,000
Prag inverter 5kva 48v...N250,000
Prag inverter 7.5kva 120v ....N410,000
Prag inverter 10kva 180v....N480,000

Prag 4kva 24v wall H ......N240,000
Prag 6.5kva 48v wall H....N350,000


PRAG servo & relay stabilizers ;

-Prag 3kva relay B(95-280v)..N
-Prag 3kva relay E(95-280v)..N
-Prag 10kva servo ..N110,000
-Prag 10kva servo(130-250v)..N115,000
-Prag 12kva servo...N
-Prag 15kva relay(95-280v)...N110,000 "Promo"
-Prag 15kva servo(80-260v)..N220,000
-Prag 15kva servo(130-260v)..N190,000
-Prag 20kva servo(130-260v)...N230,000
-Prag 20kva relay cabinet(95-280v).. N150,000
-Prag 20kva servo(80-260v) ...N330,000
-Prag 30kva servo(80-260v)...N400,000
-Prag 30kva servo(1300-260v)..N380,000


UPDATED FELICITY PRODUCTS PRICELIST!

Felicity Solar panels;
160w mono...........30,000
250w mono...........43,000
300w mono...........54,000
160w poly ............27,000
250w poly ............39,000
300w poly ............50,000

Felicity battery;
200ah .................95,000

Felicity inverters ;
2.5kva 24v.............115,000
3.5kva 24v .............155,000
4kva 48v...................165,000
5kva 48v ...............220,000 ONGOING PROMO N155,000
7.5kva 48v..............340,000

Felicity hybrid inverters ;
800w 12v ............. 125,000
1600w 24v ........... 140,000
2400w 24v ........... 150,000
5kva with pwm .....200,000
5kva with mppt .....230,000

Felicity solar charge controllers 12-48v specs;
30a pwm..............20,000
40a pwm. ............25,000
50a pwm..............30,000
60a pwm..............35,000
40a mppt..............95,000
60a mppt .............120,000

KINDLY HURRY WHILE STOCK LASTS!


Protek 200L solar water heater... N215,000
With 30k , I can offer you a set of pro solar roof mounts to comfortably mount 4 units of 250 to 350w solar panel's including kits like ;
2 qty solar mount rail "4200mm" ,
4 qty rack end clamp,
6 qty mid clamp,
6 qty L feet with rubber & special screw....
Same goes to angle positioning solar kits;
- Adjustable front leg
- Adjustable rear leg
- Rail splice kit
- Grounding lug


WHATSAPP::: https:///2348170385620

*AUTHORISED DEALER PRAGMATIC TECHNOLOGIES*
All our prag products comes with reliable warranty
*AUTHORIZED DEALER INDIAN INVERTERS / BATTERIES ... Luminous PRODUCTS*
All our products come with 1 year Warranty
*AUTHORIZED DEALER SOLAR SHOP LTD PRODUCTS*
All our products come with 1 year Warranty.
For best affordable prices contact,
The number 1 credible online store,
Smartcell Global Services,Lagos Nigeria.
Simply call Sir Frankie "08135031951" for purchase,fast delivery and waybills .. Thanks !!

1 Like

Re: Solar Energy, A Complement To FTA by pranil(m): 2:17pm On Apr 30, 2019
NairaBaba:


It can easily be achieved if the voltage is used as the signal instead of power. I currently have a system that uses the battery voltage as the signal to active a low/high disconnect monitoring Relay which in turn activate or de-activate contactors. These contactors control selected loads such fridge, ACs, sockets etc

Not for Solar production. SOC and voltage is not directly related to solar production in Inverter charger setup. if NEPA is available the inverter will keep the battries charged so Solar is still idling

Using SOC to optimize smaller loads like Refrigeration and pumps will not optimally work as the PV production can change every minute and may not match the load profile cycling the battery unnecessarily - ( every unit /KWH from battery will cost you 50 NGN while solar will be producing at 25 to 30 NGN so it makes sense to optimize the battery not solar


The only way to fully optimize excess solar production is to monitor incoming power and solar production and use AC coupling

in off-grid setup USE Battery, voltage /SOC to run a large load like water heater makes sense if the energy gain is significantly high


However, the easiest way to do this is if you have a charge controller with load output - e.g. epsolar/morningstar/victron - The load output can start a relay which will control opportunistic loads such a water pumping / AC/water heating -



https://www.youtube.com/watch?v=vvNk-VBbCRU



see the clip I made earlier where the system only takes 100 watt from grid and balance from solar

2 Likes

Re: Solar Energy, A Complement To FTA by ceaser: 7:56pm On Apr 30, 2019
ojeysky:


Can you let me know the model/spec of this freezer?
Thanks

Sorry I'm seeing your post late.

I should be home by the weekend. I will take pictures of the information on the sticker and the model number and get it across to you.
Re: Solar Energy, A Complement To FTA by earthrealm(m): 8:27pm On Apr 30, 2019
ojeysky:


Can you let me know the model/spec of this freezer?
Thanks

LG freezer of similar capacity is still same wattage, also samsung....
i simply went with my watt meter when i was freezer hunting, i suggest you do same

1 Like

Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 8:36pm On Apr 30, 2019
Good day Sir and many thanks for the A2A.

When I add all your loads together, I get 1.12kw without ACs while with one AC as you stated we are looking at 2.6kw of loads.

With any lead acid battery bank you are looking at at least 20-24 units of 12v 200Ah batteries to power 2.6kw of loads continuously except AC use is planned for solar hours or On-Grid only. With 1.12kw of loads we are looking at 10-12 12v 200Ah batteries to power the load continuously.

With a Lithium bank, you may be able to get away with 80% DoD and a smaller battery bank size albeit at a steep entry cost.

For 1.12Kw of loads, 12pcs of 250w panels should do, although I always like to oversize my PV array slightly, 2.6kw of loads we are looking at the 18-24 panel option (assuming 48v nominal inverter and batteries).

I can't tell which is Lithium or Lead Acid in your 3 battery options but all the battery sizes appear rather undersized for the loads you want to power except you scale down the loads or actively manage them.

Long and short is none of the offers seem to cut it at first glance, you would probably have to mix and match across the offers.

For panels, I recommend Canadian Solar for solid performance at a good price - You may reach out directly to discuss how you may optimize your system design and I can also supply you Canadian Solar panels and Quanta batteries at very good prices if you wish.


CNN80:
Hello Niyi,

I was hoping you could help me out as you know a lot about batteries.

I want to install a 5kVA solar PV system at home. I have had offers for regular lead acid batteries, tubular batteries and lithium ion batteries (GSL Powerwall). I want to know what you think is a good option for me.

Setup wise, I've had the following offers

12 Solar Panels (24V, 250W); 8 batteries (12V, 150A)

20 Solar Panels (24V, 250W); 10 batteries (200Ah)/12 batteries (150Ah)

16 Solar Panels (250W); 8 batteries (220Ah)

According to my estimates, the fridges use 450W, the TV 100W, the ACs 1472W, the Fans 375W, the Bulbs 135W and the Laptop 60 W.

We are moving house so the plan is to cut down on our energy use. Consequently, I'm hoping to wire the house in such a way that when the inverter is receiving power from the panel or grid, everything can be put on but when the inverter is drawing power from the batteries, only essential power points will be available.

I've been reading some of your posts and would really appreciate your input.

Thanks



2 Likes 1 Share

Re: Solar Energy, A Complement To FTA by chris81964(m): 9:59pm On Apr 30, 2019
I broke down and joined the LG AC Revolution. I run it from 1030 am to 430 pm daily and for 1 hour at night. I am not so sure that it is that much more efficient than a regular AC. There are many options on how I can run it relative to the window unit I have in my office.
My Nissan leaf batteries are kicking ass.

1 Like

Re: Solar Energy, A Complement To FTA by ceaser: 3:56am On May 01, 2019
earthrealm:


LG freezer of similar capacity is still same wattage, also samsung....
i simply went with my watt meter when i was freezer hunting, i suggest you do same

In fact, right now there is hardly any electronics purchase I do without taking my wattmeter along. The merchants always look like "what is this guy doing" whenever I request their indulgence to plug in the appliance thru the meter when testing.

Apparently majority of them do not know that "energy savers" should be the watchword either on grid power or green power.

Oga Ojeysky should get a wattmeter as a handy tool. It'll help a lot.

4 Likes

Re: Solar Energy, A Complement To FTA by ceaser: 4:06am On May 01, 2019
CNN80:


According to my estimates, the fridges use 450W, the TV 100W, the ACs 1472W, the Fans 375W, the Bulbs 135W and the Laptop 60 W.

Thanks

I'm assuming your calculation for the bolded are based on the maximum power consumed. So aside from Oga Niyi's recommendation, you can still get more run time if you switch to energy saving mode. Your bulbs can be changed to low power LED bulbs. A 60" Hisense TV that peaks at 150 watts drops to 45 watts at energy saving settings. So you may want to consider using TVs with that feature.
Re: Solar Energy, A Complement To FTA by Reprobate: 6:45am On May 01, 2019
chris81964:
I broke down and joined the LG AC Revolution. I run it from 1030 am to 430 pm daily and for 1 hour at night. I am not so sure that it is that much more efficient than a regular AC. There are many options on how I can run it relative to the window unit I have in my office.
My Nissan leaf batteries are kicking ass.

wow, this interface is pretty cool,
Re: Solar Energy, A Complement To FTA by chris81964(m): 6:55am On May 01, 2019
Reprobate:


wow, this interface is pretty cool,
Thank you
Re: Solar Energy, A Complement To FTA by earthrealm(m): 11:38am On May 01, 2019
ojeysky:


Will patronise them if indeed it's how dey charge. I have reached out to them waiting for their response.
Thanks

update: i withdraw my referral of shoptomydoor, , they are going steadily downhill,
since they give you an address and you buy stuff and ship to their address, you are literally in their hands, a pal was forced to pay 4x the item weight price, as Shoptomydoor changed the game midway and came up with volumetric weight issh, item of about 10Lbs, now became 45Lbs, his previous 2 or 3 transactions with them was ok o

2 Likes

Re: Solar Energy, A Complement To FTA by ojeysky(m): 4:14pm On May 01, 2019
earthrealm:


update: i withdraw my referral of shoptomydoor, , they are going steadily downhill,
since they give you an address and you buy stuff and ship to their address, you are literally in their hands, a pal was forced to pay 4x the item weight price, as Shoptomydoor changed the game midway and came up with volumetric weight issh, item of about 10Lbs, now became 45Lbs, his previous 2 or 3 transactions with them was ok o

I reached their customer support and their response also gave me a hint that they are not good to deal with. Kindly provide update if you find another reliable shipper with reasonable price.
Re: Solar Energy, A Complement To FTA by CNN80: 5:25pm On May 01, 2019
HI,

Thanks so much for answering me. I really appreciate it.

I wasn't planning to run any of the heavy power equipment on the batteries although I'm now considering running one AC, maybe one of those inverter ACs.

None of the offers was for a Lithium Battery. The 8 batteries offers were tubular batteries; the 10/12 Lead Acid.

The Lithium Ion Battery offer was for a SmartLiving PowerWall LiFePO4 Battery Pack (48 V 200Ah/9,600 Wh) with 12 315W Monocrystalline Solar Panels and a 6kVA Hybrid Inverter.

I'm looking to conserve power not consume it so the plan is to be as efficient as possible. Which is why I was hoping for an inverter or controller that will send power to the entire house when solar or grid energy is detected and power to a few designated power points when battery energy is detected.

What is special about the Quanta battery? What kind is it? Have you used it before?

Do you have any recommendations for inverters?


NiyiOmoIyunade:
Good day Sir and many thanks for the A2A.

When I add all your loads together, I get 1.12kw without ACs while with one AC as you stated we are looking at 2.6kw of loads.

With any lead acid battery bank you are looking at at least 20-24 units of 12v 200Ah batteries to power 2.6kw of loads continuously except AC use is planned for solar hours or On-Grid only. With 1.12kw of loads we are looking at 10-12 12v 200Ah batteries to power the load continuously.

With a Lithium bank, you may be able to get away with 80% DoD and a smaller battery bank size albeit at a steep entry cost.

For 1.12Kw of loads, 12pcs of 250w panels should do, although I always like to oversize my PV array slightly, 2.6kw of loads we are looking at the 18-24 panel option (assuming 48v nominal inverter and batteries).

I can't tell which is Lithium or Lead Acid in your 3 battery options but all the battery sizes appear rather undersized for the loads you want to power except you scale down the loads or actively manage them.

Long and short is none of the offers seem to cut it at first glance, you would probably have to mix and match across the offers.

For panels, I recommend Canadian Solar for solid performance at a good price - You may reach out directly to discuss how you may optimize your system design and I can also supply you Canadian Solar panels and Quanta batteries at very good prices if you wish.


Re: Solar Energy, A Complement To FTA by CNN80: 5:29pm On May 01, 2019
Hello,

How do I switch to enerygy saving mode? The max rating of any of our LED bulbs is 15W and we are planning to change all to at most 10W. Of course we won't have all on at the same time. I am a big proponent of sustainability.

By the way, can I run my water pump on solar?

ceaser:


I'm assuming your calculation for the bolded are based on the maximum power consumed. So aside from Oga Niyi's recommendation, you can still get more run time if you switch to energy saving mode. Your bulbs can be changed to low power LED bulbs. A 60" Hisense TV that peaks at 150 watts drops to 45 watts at energy saving settings. So you may want to consider using TVs with that feature.
Re: Solar Energy, A Complement To FTA by SolnergyPower: 9:30pm On May 01, 2019
Sure, you can run water pump on solar.

CNN80:
Hello,

How do I switch to enerygy saving mode? The max rating of any of our LED bulbs is 15W and we are planning to change all to at most 10W. Of course we won't have all on at the same time. I am a big proponent of sustainability.

By the way, can I run my water pump on solar?

(1) (2) (3) ... (524) (525) (526) (527) (528) (529) (530) ... (1853) (Reply)

FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread

Viewing this topic: chymer(m), Drgreatone, abuzz33, HeavenlyBang(m)

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 108
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.