Welcome, Guest: Register On Nairaland / LOGIN! / Trending / Recent / NewStats: 3,207,747 members, 8,000,172 topics. Date: Tuesday, 12 November 2024 at 01:21 AM |
Nairaland Forum / Entertainment / TV/Movies / Satellite TV Technology / Solar Energy, A Complement To FTA (2381918 Views)
UPS Back-up, Also A Complement To FTA / FTA Frequency / Cctv Installation A Complement To Fta And Solar Energy (2) (3) (4)
(1) (2) (3) ... (530) (531) (532) (533) (534) (535) (536) ... (1853) (Reply) (Go Down)
Re: Solar Energy, A Complement To FTA by earthrealm(m): 12:43pm On May 17, 2019 |
Dkev: is ur setup/inverter 12v or 24v, whats ur avg daily harvest?, if 24v, that may be part of your problem. 2ndly whats the size of your cables, cc to batt bank and panel to cc i have a mini system 1 x 12v 200ah, 250w panel and i harvest 1kwh avg daily, though max instantenous i have seen is 140w, probablly cos the load is small, and battery doesnt get depeleted much |
Re: Solar Energy, A Complement To FTA by Dkev: 1:03pm On May 17, 2019 |
earthrealm: it is a 24v system and the harvest is about 0.45- 0.55kwh daily. I have 2x300w connected in series to another controller (but mounted in an identical position) and that gives about 200- 400w, sometimes 500w briefly instantaneous. hence my concern |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 1:22pm On May 17, 2019 |
Dkev: mppt needs +5v headroom to work, ur system being 24v, if perhaps the batt is at 25v...ur panel outs btw 27v to 35v, so you can see that at anything below say 31v, it cant charge your batts, you can also see that your other installation is doing better, cos you wired 2 panels in series, thus higher voltage headroom. for the troublesome setup, either downgrade to a 12v setup or u connect have 2 panels in series. am assuming your cable sizes and distance is within spec |
Re: Solar Energy, A Complement To FTA by tsiriman(m): 6:44pm On May 17, 2019 |
Please house which is the best or let me say a good 3.5kva 48V inverter one can buy? I also plan to pair the inverter with quanta batteries, is this a good combo? |
Re: Solar Energy, A Complement To FTA by ehix89(m): 8:58pm On May 17, 2019 |
Buy these cheap inverter batteries and power issues will be history. I offer full refund should the batteries fall short of expectation. Kindly whatsapp me on 08030803threeeightzero
|
Re: Solar Energy, A Complement To FTA by FabioPeter: 8:59pm On May 17, 2019 |
Schneider but it comes st a premium tsiriman: 1 Like |
Re: Solar Energy, A Complement To FTA by Ativ: 9:43pm On May 17, 2019 |
tsiriman: Victron is one of the best inverters you can get. Its global 5 year warranty is attestation to its high quality, engineering precision and ruggedness. I am offering you a 3KVA 24V Multiplus inverter-charger for N425k. Pls call/whatsapp 08118419901. 1 Like |
Re: Solar Energy, A Complement To FTA by tsiriman(m): 1:13am On May 18, 2019 |
Ativ: This is quite expensive above my budget, thanks |
Re: Solar Energy, A Complement To FTA by tsiriman(m): 1:14am On May 18, 2019 |
FabioPeter: Please suggest a cheaper option |
Re: Solar Energy, A Complement To FTA by FabioPeter: 6:40am On May 18, 2019 |
Luminous 3.5KVA is ok. Pls avoid Sukam, the old model is rugged but the new one is bad market. tsiriman: 1 Like |
Re: Solar Energy, A Complement To FTA by pranil(m): 8:27am On May 18, 2019 |
earthrealm: Check if the controller Voc will allow three panels in series and then use only one controller |
Re: Solar Energy, A Complement To FTA by pranil(m): 8:38am On May 18, 2019 |
tsiriman: If planning solar upgrade in future Ipower [zinnox] is an option if your loads are only tv and fridge plus lights you can easily use a victron 800 VA which can Handel 1600 watts short time loads and much more efficient apart from reliability You can even optimise buy buying only 2 batteries for 24v but higher ah https://www.ebay.co.uk/itm/Victron-Mini-Inverter-Charger-Multiplus-12-24-48V-800VA-230V-FREE-EU-Delivery-/302428570028 |
Re: Solar Energy, A Complement To FTA by Namzy(m): 9:24am On May 18, 2019 |
Does anybody know how to equalize with fangpusun properly? I'm asking because when the set automatic equalization reaches it just equalize (absorption and float light on) for about 20 mins before switching back to float. I'm not sure that s enough time for equalization |
Re: Solar Energy, A Complement To FTA by Ativ: 9:28am On May 18, 2019 |
tsiriman: May have other options for you in your range. Please give me a call/whatsapp me. |
Re: Solar Energy, A Complement To FTA by tsiriman(m): 10:00am On May 18, 2019 |
FabioPeter: Thank you. I was thinking of luminous 3.5KVA but will that be a good choice if I plan to upgrade to solar in the future? |
Re: Solar Energy, A Complement To FTA by tsiriman(m): 10:02am On May 18, 2019 |
pranil: Thank you for the suggestion but 800VA will be to small even though I don't plan to run AC or heater with it. I have 2 TVs and several fans. |
Re: Solar Energy, A Complement To FTA by tsiriman(m): 10:02am On May 18, 2019 |
Ativ: Will do |
Re: Solar Energy, A Complement To FTA by mikylon(m): 1:06pm On May 18, 2019 |
tsiriman: You can always incorporate solar panels and charge controllers to the luminous inverter at anytime. |
Re: Solar Energy, A Complement To FTA by bigrovar(m): 1:51pm On May 18, 2019 |
Namzy:One of the weak points of fangpusun is equalisation is automatically timed and decided by the cc charge algorithms which sometimes is too conservative. What you can do is to restart the charging process by turning of the pv input and pvoutput forcing it to restart the charging process. You might also considering forcing it by increasing the absorption voltage if you will not be at home in which case auto equalization will become useless to you. You can also increase the frequency to maybe every 10 days? |
Re: Solar Energy, A Complement To FTA by Saipro(m): 2:44pm On May 18, 2019 |
tsiriman:I run two TVs, lights and at least 3 fans at any point in time on mine. It's the 375VA/48V model (300W). Reserved for nighttime loads. |
Re: Solar Energy, A Complement To FTA by olatade(m): 3:12pm On May 18, 2019 |
tsiriman: i have a 850va luminous hybrid inverter. two tvs(42 inch and a 55inch) are connected to it.(make sure they're on energy saving mode).ten 5watts energy saving bulbs and two small size(130watts and 70watts) standing fans and a ceiling fan are also connected to it and i run them all at once most of the time. the inverter is durable,it can meet your needs for now that is if you don't put on all you fans at once. |
Re: Solar Energy, A Complement To FTA by tsiriman(m): 3:56pm On May 18, 2019 |
Saipro: Thanks for sharing, this is the size I'm looking at, 3kw 48V. |
Re: Solar Energy, A Complement To FTA by tsiriman(m): 3:56pm On May 18, 2019 |
olatade: Thanks for sharing |
Re: Solar Energy, A Complement To FTA by Namzy(m): 6:48pm On May 18, 2019 |
bigrovar:Thanks I did increase the absorption but then after sometime it entered float. What I did was to increase float to 31v for 2 hours, hope that will suffice |
Re: Solar Energy, A Complement To FTA by pranil(m): 10:15am On May 19, 2019 |
tsiriman: You can get a luminous 1500 VA solar hybrid. With 24v battery you can even save the battery cost https:///product/luminous-luminous-1-5kva-solar-hybrid-inverter-4193884 |
Re: Solar Energy, A Complement To FTA by BRIGHTSOLAR(m): 2:59pm On May 19, 2019 |
ONLINE DELIVERY OF RENEWABLE ENERGY MATERIALS INVERTER MICROTECH INVERTER 900VA,12V N46,000 1.1KVA,12V N53,000 1.6KVA/24V N72,000 2KVA/24V N80,000 2.6KVA/36V N105,000 3.6KVA/48V N170,000 5.2KVA/48V N340,000. 5.5KVA/96V N340,000 10KVA/180V N790,000 PRAG INVERTER 1.1KVA,12V N70,000 1.2KVA,12V N90,000 1.5KVA/24V N110,000 2.5KVA/24V N125,000 4KVA/24V N270,000. 7.5KVA/120V N500,000 LUMINOUS INVERTER 1.5KVA/24V N58,000 2.6KVA/36V N105,000 3.5KVA/48V N210,000 5KVA/48V N340,000. 5KVA/96V N340,000 10KVA/180V N750,000 MUST POWER STAR INVERTER 4kva 3000W 24V N 220,000 4kva 3000W 48V N 260,000 5kva 4000W 48V N 350,000 6kva 5000W 48V N 400,000 7.5kva 6000W 48V N 450,000 10kva/48V 8000W 48V N 950,000 KEYE INVERTER KEYE 1.2KVA/12V - N54,000 KEYE 3.5KVA/24V - N180,000 KEYE 3.5KVA/48V - N180,000 KEYE 5KVA/24V – N275,000 KEYE 5KVA/48V -N 1275,000 KEYE 7.5KVA/48V – N400,000 KEYE 10KVA/48V – N6800,000 HYBRID INVERTER VOLTRON SERIES 1.4KVA/12(30A N65,000 2.4KVA/24V50A N97,000 3KVA /48V 60A MPPT N220,000 5KVA /48V 60A MPPT N310,000 7.5KVA /48V 60A MPPT N430,000 10KVA /48V 100A MPPT N750,000 15KVA /48V 60A MPPT N850,000 15KVA /48V 120A MPPT N890,000 GENEXTECH SERIES 2KVA/24V(600W MPPT) #138,000 3KVA/24V(600W MPPT) #149,000 3KVA/24V(1500W MPPT) #194,000 3KVA/48V(3000W MPPT) #202,000 5KVA/48V(3000W MPPT) #306,000 10KW/48V(14850W MPPT) #1,660,000 STABILIZER VOLTRON STABLIZER 6KVA WALL MOUNT RELAY REGULATOR #45,000 6KVA WALL MOUNT SERVO REGULATOR #65,000 12KVA WALL MOUNT RELAY REGULATOR #90,000 12KVA WALL MOUNT SERVO REGULATOR #120,000 PRAG STABLIZER 10KVA WALL MOUNT SERVO REGULATOR #130,000 12KVA WALL MOUNT RELAY REGULATOR #120,000 15KVA WALL MOUNT RELAY REGULATOR #140,000 15KVA WALL MOUNT SERVO REGULATOR #240,000 20KVA RELAY REGULATOR #195,000 20KVA SERVO REGULATOR #370,000 30KVA SERVO REGULATOR #470,000 BATTERY LUMINIOUS BATTERY 12V/200AH N 125,000 LONG BATTERY 12V/200AH N 120,000 MONBAT BATTERY 12V/200AH N 125,000 ELSON BATTERY 12V/200AH N 115,000 MICROTEC BATTERY 12V/200AH N 105,000 M POWER BATTERY 12V/200AH N 115,000 EASTMAN 12V/200AH TALL TUBULAR BATTERY N115,000 GLT BATTERY 12V/200AH N 90,000 ZEEDIX BATTERY 12V/200AH N 95,000 RITAR BATTERY 12V/200AH N 130,000 PRAG BATTERY 12V/200AH N 140,000 GENUS BATTERY 12V/200AH N125,000 RITAR 200A BATTERY .......................N 115,000 MOTOMA 200A BATTERY ................N 120,000 CINEMAX 200A BATTERY ................N 120,000 QUANTA BATTERY 12V/200AH N 140,000 ALIGRAND 200A BATTERY ................N 120,000 NPP 200A BATTERY ................N 120,000 BATTERY RACK BATTERY RACK 2 BATTERY N 15,000 BATTERY RACK 4 BATTERIES N 30,000 BATTERY RACK 8 BATTERIES N 50,000 CHARGE CONTROLLER ROY SOLAR SERIES 20A 12/24V PWM CONTROLLER N 20,000 30A 12/24V PWM CONTROLLER N 25,000 40A 48v PWM controller (LED) N 50,000 30A 96v PWM controller (LCD) N 120,000 60A 48v PWM controller (LCD) N 95,000 COWIN SERIES 20A 12/24V PWM CONTROLLER N 15,000 30A 12/24V PWM CONTROLLER N 20,000 40A 12/24V PWM CONTROLLER N 25,000 50A 12/24V PWM CONTROLLER N 32,000 60A 12/24V PWM CONTROLLER N 41,000 40A 48v PWM controller (LED) N 25,000 50A 48v PWM controller (LED) N 32,000 60A 48v PWM controller (LED) N 50,000 COWIN MPPT SERIES 40A 12/24/48v MPPT controller (LCD) N 80,000 60A 12/24/48V MPPT controller (LCD) N 130,000 EPEVER MPPT SERIES 12/24/48 /45A N 145,000 12/24/48 /60A N155,000 SRNE MPPT 12/24/36/48V/60A N115,000 FANGUNPSUN MPPT SERIES 30A 24V N40,000 60A 48v N140,000 80A 48v N170,000 SOLAR PANELS JOY SOLAR PANEL 150w MONO -N32,000 200w MONO -N33,000 260w MONO -N54,000 150w POLY –N27,000 200w POLY -N31,000 260w POLY -N52,000 TRINA SOLAR PANEL 300w MONO -N85,000 350w MONO -N110,000 YINGLIN SOLAR PANEL 100w POLY -N22,000 150w POLY -N33,000 200w POLY -N39,000 260w POLY -N51,000 310w POLY -N62,000 100w MONO-N25,000 150w MONO -N33,000 200w MONO -N39,000 260w MONO -N59,000 320w MONO -N74,000 JINKO SOLAR PANEL JINKO SOLAR 370WATT MONO - N80,000 JINKO SOLAR 340WATT MONO - N70,000 JINKO SOLAR 280WATT MONO - N57,000 JINKO SOLAR 265WATT POLY - N55,000 ERA SOLAR PANEL ERA SOLAR 300WATT MONO – N56,000 ERASOLAR 370WATT MONO - N72,000 CANADIAN SOLAR PANEL MONO- 300w. N52,000 (BULK PURCHASE ONLY) 330w. N54,000 (BULK PURCHASE ONLY) POLY 270w. N48,000 (BULK PURCHASE ONLY) ACCESSORIES PROGRAMMABLE Digital timer 15A N7,000 PROGRAMMABLE Digital timer 25A N9,000 BATTERY BALANCER /EQUALIZER 48V -------------35,000 BATTERY BALANCER EQUALIZER 24V ---------------#30,000 BATTERY VOLTMETER INDICATOR ------------------#1,700 DC SURGE ARRESTOR 800VDC------------------------------------N26,000 INSTALLATION KITS L.FOOT N1,000 (MINIMUM ORDER 10 PIECES) MID CLAMP N1,000 (MINIMUM ORDER 10 PIECES) END CLAMP N1,000 (MINIMUM ORDER 10 PIECES) DC IRON 150WATTS #9,000 COMPLETE SOLAR SOLUTION Call-07058562938 Bright Solar Power WHATSSAP 08187995847 FOR PURCHASE/ DELIVERY /INSTALLATION NATIONWIDE https:///send?phone=2348187995847 visit our updated website www.brightsenergy.com |
Re: Solar Energy, A Complement To FTA by JUO(m): 4:09am On May 20, 2019 |
Saipro:what is the essence of using small inverter at night, to conserve energy? |
Re: Solar Energy, A Complement To FTA by Saipro(m): 8:05am On May 20, 2019 |
JUO:Think - fewer batteries (with all the benefits like fewer failure points, lesser maintenance hassles, cost benefits, etc) - shallower cycling - same derived utility Let me paint the picture: overnight, consumption altogether culminates to about 2,000W max on any given night. On a typical night, my energy use averages 1,300W. This includes the inverter's tare load. Specifically, my inverter claims about 130W max from that figure. My daytime inverter on the other hand has a tare consumption of a minimum 1,200W overnight! In essence, the inverter on its own is able to drain the batteries as might the entire house household. Oversimplifying the maths, the inverter literally doubles my night-time consumption. Here's the interesting conclusion: since my house runs entirely from panels during the day, the batteries come into play at night. If I halve my cycling depth, I can theoretically double my cycle life. If my bank might have lasted me 4 years with my PowerStar inverter, it should take me 8 years with the Victron. Another way to look at it is, I could halve the size of my battery bank while retaining the same days of autonomy, should the sun misbehave (which is purely a myth at this point for my panels are sufficiently oversized to take me to absorb everyday even if they don't do float on sunless days). That way, I can go for an extra 2 nights should something catastrophically go wrong with my panels (insufficient insolation no longer being an issue). And this is a mere 3kWp of PV. Fewer panels required to get the job done - an unintended benefit. The panels had been there before the new inverter and were about 50% oversized. Effectively, I'm now 100% oversized. All these and lots more by merely having a night-time inverter. The cost savings are within the first year and the benefits until the said inverter croaks. Or a guru here decides to test it with his trusted hammer (that hammer has acquired Mjölnir-like attributes). Of course, all the aforementioned presume optimisation of your system. 1 Like |
Re: Solar Energy, A Complement To FTA by JUO(m): 8:41am On May 20, 2019 |
Saipro:but must people are not aware of this energy conservation. My inverter is 14w and 3.5kw 48v at that. I can't use any inverter that the idle consumption is more than 20w henceforth. Any good system should survive with 120ah over night with basic load. Nice one with your logic 1 Like |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 8:46am On May 20, 2019 |
tsiriman: For ruggedness buy Indian inverter, though u v to find a means to boost ur charging current(either solar or external charger) as they come with low charging current. Call/whatapp 08117398294 to order. 3.6kva Microtek - 170k 1 Like |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 9:19am On May 20, 2019 |
Mercury battery available and affordable 200ah - 95k Call/whatapp 08117398294 to order now
|
Re: Solar Energy, A Complement To FTA by Saipro(m): 10:06am On May 20, 2019 |
JUO:Brand and model of inverter? |
(1) (2) (3) ... (530) (531) (532) (533) (534) (535) (536) ... (1853) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: 3 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 107 |