Re: Solar Energy, A Complement To FTA by Namzy(m): 9:02am On Aug 06, 2019 |
ceaser:It's 205 liters with net capacity of 198l[written on the back] final watts after being on for about 6 hours is 56watts |
Re: Solar Energy, A Complement To FTA by Namzy(m): 9:06am On Aug 06, 2019 |
ceaser:Yes but I measured the watts during grid power as the rains have been too much and we have been having stable grid power |
Re: Solar Energy, A Complement To FTA by Valto(m): 9:26am On Aug 06, 2019 |
ceaser:thanks for this, already thinking my battery must have depreciated. mine normally reads between 25.4 and 25.5 during evenings, when there is no solar power, but 27.2 when fully charged with solar. |
Re: Solar Energy, A Complement To FTA by SolnergyPower: 10:03am On Aug 06, 2019 |
This is deep. Thanks for the insight. ceaser: |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 10:54am On Aug 06, 2019 |
olatade: what do u see on the screen of your cc?, abi you are asking a hypothetical question? if you hv 600w panel hooked up on a 12v system as you describe, under ideal conditions, which include panel orientation and angle, panel make and efficiency, proper cable sizing etc, max current you would expect to get is 600w/12v -- 50amps, but since we know nothing is ideal in nature, your max instantenous harvest maybe 500w or 42amps, though the avg wud be btw 200w n 350w, thus 20amps to 30amps, wch is ok for a 12v 200ah battery. |
Re: Solar Energy, A Complement To FTA by dejidotun2000(m): 1:18pm On Aug 06, 2019 |
Thanks ceaser: |
Re: Solar Energy, A Complement To FTA by dejidotun2000(m): 1:23pm On Aug 06, 2019 |
Thanks for taking out time to reply. That 1.5KW is very brief, hardly up to 100milliseconds, your unit does exactly the same thing sometimes (ALL AC motors experience inrush current). You just haven't noticed because it a very fleeting event. ceaser: |
Re: Solar Energy, A Complement To FTA by BetaTechnicians: 2:52pm On Aug 06, 2019 |
ceaser: What's the model and cost of that inverter, does it also have charging capability ? |
Re: Solar Energy, A Complement To FTA by olatade(m): 3:28pm On Aug 06, 2019 |
earthrealm: I'm planning on buying the mppt charge controller but for now I have the 12 volts luminous hybrid with pwm CC to make do with. thanks for the info |
Re: Solar Energy, A Complement To FTA by lexi28(m): 3:46pm On Aug 06, 2019 |
ceaser: the sqflex is a submersible pump. though it will pump if it is submerged with inlet at least 18" below water surface. so it will work from a shallow body of water as long as conditions are met. lift of the sqflex 2.5 is 250m max, but flow rate improves the smaller the head required. I.e the deeper the borehole the lower the flow rate and vice versa. here's a link to purchase: grundfos sqflex http://www.solarshopnigeria.com/accessories/grundfos-water-pumps/grundfos-sqflex-2-5-2.html Lorentz pump: https:///agege/plumbing-and-water-supply/lorentz-ps2-1800-c-sj5-12-solar-submersible-pump-system-for-4-wells-6005750.html https:///lagos-mainland/plumbing-and-water-supply/lorentz-ps2-4000-c-sj3-32-solar-submersible-pump-system-for-4-wells-12359108.html these links should give you a head start on.your enquiries. I have personally worked with both pumps they are good. good pump impellers, mppt function. here's a link for literature: https://www.lenntech.com/uploads/grundfos/95027330/Grundfos_SQF-2-5-2.pdf https://www.lorentz.de/products-and-technology/downloads https://partnernet.lorentz.de/files/lorentz_ps2_product-brochure_en.pdf http://www.solar23.com/pompe_grundfos_sqflex.html you will need 8nos of 300wp panels, storage tanks, pv pole mount, reticulation e.t.c to complete your setup. cheers. disclaimer: I do not represent any of the above companies. I am not sure if posting the Eauxwell reps number here is acceptable. anyways, you could forge ahead with the above info. 2 Likes 2 Shares |
Re: Solar Energy, A Complement To FTA by lexi28(m): 5:26pm On Aug 06, 2019 |
generationz: that would be a good deal. things to watch out for: 1. the Dc input socket. mine burnt out when an 80w panel was connected to the port.mine was basically undersized for the possible 5amps max the panel could produce. this leads to my second question 2. has your seller/vendor connected a 150w panel to the Powerbank before? some units have current limit on their charging circuits. 3. some vendors will tell you that a max of 100w only can be loaded on the Powerbank even though they sell it with a 300-500w modified sine wave inverter. practically however, in use I observed a smell of burnt wires when the power bank was loaded to only 50watts. and don't ever try to charge it with a small generator. the pack will pack up much sooner. lol when i connected the 80w panel to the Powerbank, I noticed on the digital display that the voltage was rising close to the panels Voc of 21volts.it was supposed to stop at 19v when the power bank was fully charged. (at least according to the seller). I noticed the bank overheating when a load was connected to the power bank while the panel was charging the unit. the power bank I am using is the popular black unit (CT/ZINOX). I think now I would prefer a unit built with thicker cables and connectors, these Naija built blue packs with evident BMS may be better. I hope your offer is better. cheers |
Re: Solar Energy, A Complement To FTA by ceaser: 6:20pm On Aug 06, 2019 |
Namzy: So measuring on grid power you got 70 watts consumption? 205 litres? Abeg where person fit buy that model, Online? Showrooms? And please what is the model again? I wan sell Thermocool buy Hisense wey get more sense. I have good experience with their 65" smart TV, so I think they have reliable products on offer. EDITED ON AFTERTHOUGHT: By saying "grid power" do you mean that the freezer is connected DIRECTLY to the grid or thru the inverter which in turn is plugged into the grid? Cos if that is the case, the freezer is still technically plugged into your 24 volt system and the wattmeter will still give the same readings as when the inverter is on solar alone. To be doubly sure, unplug the freezer from the inverter, then plug it directly into the mains thru the wattmeter and check the readings again. |
Re: Solar Energy, A Complement To FTA by ceaser: 6:39pm On Aug 06, 2019 |
BetaTechnicians: Neither solar charging nor grid charging capacity. Got it off of AliExpress. Got delivered to me in 12 days. |
Re: Solar Energy, A Complement To FTA by ceaser: 6:43pm On Aug 06, 2019 |
lexi28: Thanks for these details. Much appreciation. |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 7:02pm On Aug 06, 2019 |
I have an alternative hypothesis - the watts consumed by an appliance changes at different stages of work/duty cycle the appliance is in, other factors like mechanical state, maintenance e.t.c may influence the wattage e.g an electric iron may consume 1.3kw at full power when heating up the element but say 800w at a lower power setting and even less watts in standby. What you are experiencing as different watt readings has no correlation to battery or mains voltage within a standard operating band, rather it is the device's operating efficiency and amount of work being done that drive the watts consumed - so a freezer may start up at 1000w briefly then go to 180w then after 24hours and all food frozen go to 70w. If you opened the freezer a bit, compressor may kick on again and go back to 180w. The amps drawn by a device will vary based on the voltage of the power source so if measuring DC amps, the same wattage load may show twice the amps or more if measured at 24v source vs. 12v source. To clarify the science, if all other factors are held constant, the watts an appliance consumes will be influenced only by the device's design/operating efficiency and the stage of work cycle the device is at. The amps draw on the other hand will vary with the operating voltage of the source being measured. If you are measuring thesame device and getting different wattage readings, it is either different stages of the work cycle or calibration error of the measuring instrument. ceaser: |
Re: Solar Energy, A Complement To FTA by Namzy(m): 9:53pm On Aug 06, 2019 |
ceaser:It's grid power although my axpert inverter has bypass mode but I use grid more often and allow the inverter rest |
Re: Solar Energy, A Complement To FTA by babniyen(m): 7:58am On Aug 07, 2019 |
15KVA Relay Stabilizer for quick disposal (good price) Reason: Undersized Text: 08158402376
|
Re: Solar Energy, A Complement To FTA by durumibaka(m): 11:43am On Aug 07, 2019 |
Hello experts, my 3 solar panels are 300w/ 24v, CC 20a/12v/24v and UPS 1.5kva/24v. The intaller joined the 3 negative from the panel together ane deed same with the positive but i want to ask is the connection ok or ur advice. Thanks n waiting for ur response... |
Re: Solar Energy, A Complement To FTA by ojtech8291: 12:14pm On Aug 07, 2019 |
durumibaka:The modules connection is in parallel, it is okay but your CC might burn because of the excessive current from the module set up. |
Re: Solar Energy, A Complement To FTA by harizonal123(m): 2:10pm On Aug 07, 2019 |
harizonal123: I finally bought a sunfit agm battery of 12v200ah as a back up plan for my toplight gel battery. I don't intend to combine both cos of their different chemistry. I am currently doing a design to enable both charge and supply separately with the aid of double change over. So that when I am using one the other can be charging & the next day vice versa .I will update when I'm done with my connection 1 Like
|
Re: Solar Energy, A Complement To FTA by Trippledots(m): 3:12pm On Aug 07, 2019 |
generationz: Off the top of my head. -3used 100w panels connected in parallel -a 12v pwm charge controller -a 200ahr used or new. Or --3used 100w panels connected in parallel - one of them 18650 battery packs made from recycled cells -laptop adapter and phone charging ports too. For both options u may need to up your budget a little. Cheers |
Re: Solar Energy, A Complement To FTA by generationz(f): 4:34pm On Aug 07, 2019 |
Trippledots:Okay 1 Like |
Re: Solar Energy, A Complement To FTA by olaolu11(m): 5:12pm On Aug 07, 2019 |
harizonal123: . I am currently doing a design to enable both charge and supply separately with the aid of double change over. Pls show pix of the double change over. I am interested |
Re: Solar Energy, A Complement To FTA by oluwaslimzzy(m): 8:08pm On Aug 07, 2019 |
Available now !!! 7ah 12v, 12ah 12v, 18ah 12v, 100ah 12v, 150ah 12v slum, 200ah 12v Britelite AGM Deep Cycle Premium Battery at wholesale Prices with 12months warranty with T&C Applied... Call 08037748901 if you are tired of complaining about low quality batteries in the market. We only get better and never compromise. #NewArrivals #EjaNlaStraightFromTheOcean #AsEdeyHot #KingOfAGMs
|
Re: Solar Energy, A Complement To FTA by ojeysky(m): 9:01pm On Aug 07, 2019 |
harizonal123: Will be good to read your experience on the batteries, I am using sunfit panels and so far so good. |
Re: Solar Energy, A Complement To FTA by ojeysky(m): 10:31pm On Aug 07, 2019 |
Folks if your system supports equalization do ensure to do it, am not sure if this was a coincidence but I think my batteries are doing better since my first equalization. |
Re: Solar Energy, A Complement To FTA by BetaTechnicians: 4:34am On Aug 08, 2019 |
ceaser:Ok thanks. |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 5:26am On Aug 08, 2019 |
ojeysky: of course!, anybody using flooded batteries and not equalizing is just looking for trouble. 1 Like |
Re: Solar Energy, A Complement To FTA by ojeysky(m): 5:38am On Aug 08, 2019 |
earthrealm: Hahahaha I saw you cross out system I meant the backup system setup, not body system lol. Fyi, am on AGM. |
Re: Solar Energy, A Complement To FTA by Penuelseun(m): 6:22am On Aug 08, 2019 |
ceaser:Pls link of the seller and if possible pictures |
Re: Solar Energy, A Complement To FTA by Dishtech(m): 7:32am On Aug 08, 2019 |
generationz:For I have small package like that, 2 used 40ah LiFePo4 battery (10k each), 250watt solar panel (33k) 40A pwn charge controller ordered from China (6.5k) and a homemade inverter made by my self (7k), cable (3k) TOTAL #69,500. This power my 32" Led TV, home theater, decoder, my standing fan, charge my phones, and 4 Led bulbs. Am usually home from 7pm which my appliances comes on then, till 11:30pm or 12am bed time TV is off leaving light and fan till 3 or 4am when weather is cold fan is off leaving light till day break. If am home I equally use the system when battery is charged from noon and the system is running smoothly for 6 months going. Below are my setup! 7 Likes
|
Re: Solar Energy, A Complement To FTA by generationz(f): 8:03am On Aug 08, 2019 |
Dishtech: Thanks so much. This your inverter is strong o I envy you guys that can just couple things together and get what you want. All those wires dey fear me. Make I no go burn house down. Please, help a sister out where did you get the batteries? I believe I can use a. Ups for this. |
(1) (2) (3) ... (563) (564) (565) (566) (567) (568) (569) ... (1854) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: abbey086(m), dacool1(m), Deesmo07 and 4 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 104 |