Re: Solar Energy, A Complement To FTA by babaegun(m): 8:45am On Nov 26, 2019 |
ojeysky: simydan: I use the 1.5HP GenCool. Its great. I have a Power Meter attached to it. I noticed if you put it in the GenMode, It will peak at 850Watts or slightly less. It is great. You can give it a try. 1 Like 1 Share |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 10:06am On Nov 26, 2019 |
ojeysky: i thought you said your bank is 24v 300ah?...i guess you have 4 units of 150ah 12v battery,, what tyoe of batteries are they, cos am certain u can send 25amps to most 150ah deep cycle batteries, and since you have 2, thats about 50amps. some would even take more, so cross check..so you be sure the gassing you talk about occur more during equalization, which is every 1, 2, 3months..as you desire, i do mine every month, u can simply open the windows, and place a standing fan to blow the fumes away, for the 4 to 8 hrs, you may choose to do the equalization |
Re: Solar Energy, A Complement To FTA by Valto(m): 12:24pm On Nov 26, 2019 |
.. |
Re: Solar Energy, A Complement To FTA by ojeysky(m): 2:47pm On Nov 26, 2019 |
earthrealm: Yes you are correct 4x150Ah 12v = 300ah 24v. The battery has max charge written on it to be 45ah so I was using that to determine the limit for the string. However from your message it seem I should double it so my charge limit will then be 90ah correct?
It means it does occur during normal operations? The house is relatively small and have got kids but will look into that option in future though.
|
Re: Solar Energy, A Complement To FTA by earthrealm(m): 3:45pm On Nov 26, 2019 |
ojeysky: Yeah 45amps per batt, since ur string is in parallel and series, then u can send 90amps charging current to the bank theoritically, though personally i wud try n keep it under 80amps, However..your 2kw array can only do 60amps @24v. Since ur CC is 60amps, so you shud be fine. @ gassing yes again.gassing is minimal during normal charging,, unless if you set ur charging voltage setpoints rather high, then u will perceive acid vapours more often.. People hv been ingenious and designed workable systems for indoor installation of fla batts from using compact cooler container, to waterproofing the insides of a wooden rate and running piping to evacuate the gas |
Re: Solar Energy, A Complement To FTA by TommyAnthem(m): 5:53pm On Nov 26, 2019 |
Question for the guru's in the house: If I have a setup of solar panels of 600w and my battery is 200ah, is it possible enjoying the surplus wattage generated by the solar panel while the battery is charging? ojeysky: |
Re: Solar Energy, A Complement To FTA by simydan(m): 7:45pm On Nov 26, 2019 |
TommyAnthem: It all depends on the type of inverter you're using as well as the load. As long as it does not exceed far more than the excess power from your panels. But know that, you pay for what you get as most inverters with this function comes with a cost. You can see from the picture below! 1 Like
|
Re: Solar Energy, A Complement To FTA by mahkanjuh: 10:16pm On Nov 26, 2019 |
Please, Good evening house, my target is 24/7 light. My appliances are one 40inches TV, 2 decoders, 1 sound system, 2 fans and 4 bulbs. Please, what should be my budget and the break down of the things that I will buy to serve this purpose. Thanks please |
Re: Solar Energy, A Complement To FTA by mahkanjuh: 10:17pm On Nov 26, 2019 |
Topmost11:How much does this your 24/7 light cost you? |
Re: Solar Energy, A Complement To FTA by ojeysky(m): 10:29pm On Nov 26, 2019 |
earthrealm: Oh okay cool, I have learnt a new thing. However..your 2kw array can only do 60amps @24v. Since ur CC is 60amps, so you shud be fine. Actually my CC is 80amps but yes I have a array limitation for now.
Interesting indeed. Thanks |
Re: Solar Energy, A Complement To FTA by ofemigeorge(m): 6:54am On Nov 27, 2019 |
Redberyl:there is a video on youtube on how to correct the line Dont need to call anyone do it yiour self it requires cleaning a particular place |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 10:06am On Nov 27, 2019 |
HURRY! LIMITED QUANTITY!! BRAND NEW MADE IN GERMANY SOLARWORLD SOLAR PANELS UP FOR SALE! Solarworld 280W mono= 15 (70,000) Solarworld 315W mono= 9 (75,000) Solarworld 340W mono= 8 (80,000) Solarworld 175W poly= 14 (45,000) Contact, Smartcell global services 081-350-31951 WHATSAPP::: https:///2348170385620 |
Re: Solar Energy, A Complement To FTA by mahkanjuh: 10:18am On Nov 27, 2019 |
Please house, my target is 24/7 light. My appliances are one 40inches TV, 2 decoders, 1 sound system, 2 fans and 4 bulbs. Please, what should be my budget and the break down of the things that I will buy to serve this purpose. Thanks please |
Re: Solar Energy, A Complement To FTA by Nobody: 10:30am On Nov 27, 2019 |
ofemigeorge:pls can u send me the link or name of the YouTube account .thanks |
Re: Solar Energy, A Complement To FTA by ofemigeorge(m): 10:49am On Nov 27, 2019 |
Redberyl:I stumbled on itvwatched it three days ago try typing your findings search |
Re: Solar Energy, A Complement To FTA by ofemigeorge(m): 10:50am On Nov 27, 2019 |
|
Re: Solar Energy, A Complement To FTA by Nobody: 11:00am On Nov 27, 2019 |
ofemigeorge:ok.. Thanks |
Re: Solar Energy, A Complement To FTA by simydan(m): 11:27am On Nov 27, 2019 |
mahkanjuh: You need to know the wattage of every thing you intend to use and the hours of usage before you get a reasonable quotation. |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 12:06pm On Nov 27, 2019 |
<> |
Re: Solar Energy, A Complement To FTA by ojeysky(m): 3:48pm On Nov 27, 2019 |
babaegun: Thanks for your response, do you think if I get a 1HP there will be significant reduction in the consumption compared to 1.5HP that does 850w? |
Re: Solar Energy, A Complement To FTA by tonididdy(m): 11:21pm On Nov 27, 2019 |
ojeysky:Hi, pls what does this power in your home and what's the standby time at night? |
Re: Solar Energy, A Complement To FTA by mahkanjuh: 12:57am On Nov 28, 2019 |
simydan:let's say the total wattage is 750wat and expecting to run over 18hrs to 24hrs?? Please, what would I need and what would be the cost? |
Re: Solar Energy, A Complement To FTA by Malevonent: 6:39am On Nov 28, 2019 |
So my mustpower 4kva 48v inverters has started acting up.. Its back feeding its3lf, and powering itself+other household loads not on the inverter load line.. The problem is puzzling in that. Digital meter readings at its ac input side is normal/zero.....however once the breaker is on..somehow the circuit is complete and a reading of 230v is obtained. Am wondering if this is a house electrical fault or an inverter fault..am leaning towards an electrical fault in the house, but strange that it would suddenly just start, since no work has been done on the house wiring lately |
Re: Solar Energy, A Complement To FTA by babaegun(m): 7:18am On Nov 28, 2019 |
ojeysky: Yes. It will likely be between 640 -700 Watts or less. Just give it a try. Am sure you will be glad |
Re: Solar Energy, A Complement To FTA by Penuelseun(m): 7:43am On Nov 28, 2019 |
Malevonent:I think you should disconnect the ac input side, then check it for any faults with your multimeter when you power it on 1 Like |
Re: Solar Energy, A Complement To FTA by simydan(m): 8:26am On Nov 28, 2019 |
mahkanjuh: For a 750w to run 18hrs: 750×18=13500w 13500+2700=16200w For 750w to run 24hrs 750×24=18000w 18000+3600=21600w To run a 16200watts or 21600watts load, you need about 15pcs to 20pcs of 200ah battery 2kw inverter. Charge Controller 3000watts panels or more... Cables and breakers. That will cost a fortune, seriously talking of millions. But, in the real sense a 750w load will not be run at once so, practically you may end up running say about 400w or even less at any given time so that makes the system cost effective and more realistic. You can contact me for proper costing and advice. |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 11:10am On Nov 28, 2019 |
XMAS SALES BY SMARTCELL! DONT MISS OUT!! (1) Monbat 200a 12v made in EU fta die-hard batteries (June/July manufactured) ... 116,000 per unit , 115k 4 upwards ! (2) USA Trojan 12v 205a die-hard deep cycle batteries fresh from the oven .... (3) Durable Made in China Oliter 12v 200a agm battery ... 92,000 per unit , 90k for two units upwards (4) Morningstar 45a mppt charge controller ... 140,000 (5) Morningstar 60a mppt charge controller ....190,000 (6) Schneider 1.5kva 24v solar inverter ...... 68000 per unit , 66000 two units above (7) Set of foreign solar panel roof mounts which can take up to 4 units of 300 to 400w panels ... 28,000 ( Quanta amaron 200a white carton battery ... 122000 per unit , 120000 for two upwards What are you still waiting for ?? PLACE YOUR ORDERS NOW !!! Contact, Smartcell global services 081-350-31951 WHATSAPP::: https:///2348170385620
|
Re: Solar Energy, A Complement To FTA by kiekie1(m): 11:15am On Nov 28, 2019 |
kiekie1: NOTE: If seriously interested in Black Friday sales opportunity for unit purchase of Trojan, Ultron , axpert Ms,Schneider & tbb inverters.. feel free to contact me! |
Re: Solar Energy, A Complement To FTA by eltolu: 12:44pm On Nov 28, 2019 |
Hello All, Is it possible to connect the AC output of an inverter (5KVA) to the AC input of a second inverter (1.5KVA)? Planning to do this to charge a second battery bank that does not have solar attached to it. Also, the second inverter and battery bank will power other isolated equipment. What do you experts recommend? |
Re: Solar Energy, A Complement To FTA by mctfopt: 2:09pm On Nov 28, 2019 |
eltolu: Is it possible to do that? Yes. But is it advisable to do that? The answer is NO. If you have little power from PHCN, I'd suggest you charge only the 1.5kva with it and use it as a backup inverter while running the 5kva 24/7. Or if the solar panels is enough, you can always add the other batteries to the 5kva and run only one system. I'm assuming the batteries are of the same age, size and everything. But it is not a good idea to try to charge another system from a bigger one. Are you trying to pull off a perpetual motion machine? JK. Disclaimer: not an expert 1 Like |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 7:19pm On Nov 28, 2019 |
NEW ARRIVAL! Made in Italy high quality solar panels .. Foreign European Panel for customers who don’t simply want Made in China solar modules ! Feel free to contact me for it's datasheet & purchase as usual.. Contact, Smartcell global services 081-350-31951 WHATSAPP::: https:///2348170385620
|
(1) (2) (3) ... (612) (613) (614) (615) (616) (617) (618) ... (1853) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: 2 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 69 |