Re: Solar Energy, A Complement To FTA by mctfopt: 5:45pm On Jul 09, 2020 |
jmaine: The fan sure looks like a clone or should I say a lookalike of Xiaomi Smartmi standing 2S fan. How much did you procure it? I like the pricing of the Canadian solar too. If you don't mind can you share contact of PV seller? 2 Likes |
Re: Solar Energy, A Complement To FTA by ojtech8291: 5:54pm On Jul 09, 2020 |
I don't have battery balancer now. How can I balance two batteries in series with a difference in voltage of 1V? |
Re: Solar Energy, A Complement To FTA by Trippledots(m): 5:56pm On Jul 09, 2020 |
ceaser: I used tugrow once. Although we had some issues with delay in clearing the items which unfortunately seems to be his Achilles heels, but i eventually got my items.. He was apologetic over the inconvenience when i got to his office too.... The choice of logistics is yours eventually though. |
Re: Solar Energy, A Complement To FTA by Trippledots(m): 5:57pm On Jul 09, 2020 |
earthrealm:As at last month, I was told $6/kg. 2 Likes |
Re: Solar Energy, A Complement To FTA by Trippledots(m): 6:00pm On Jul 09, 2020 |
mctfopt: Lol... His name is Tugrow. Already shared up there |
Re: Solar Energy, A Complement To FTA by Trippledots(m): 6:11pm On Jul 09, 2020 |
mctfopt: You noticed too right? Lol.. Pls price of fan oh, bros. |
Re: Solar Energy, A Complement To FTA by jmaine: 6:25pm On Jul 09, 2020 |
mctfopt: Sure it's the Xiaomi Smartmi Pedestal fan look alike. It was procured for 40K .... Deciding to purchase locally than Importing with the current Aliexpress logistics debacle was a no brainer. Your Legit Canadian solar plug is right here.... okaniudemba (08039489441).... He has been here all along..... 1 Like |
Re: Solar Energy, A Complement To FTA by mctfopt: 6:32pm On Jul 09, 2020 |
earthrealm: I use a Samsung Inverter Fridge. It is rated 140W but it can drop to around 90w after running for some time. Got it around 5 years ago. Still running. 2 Likes 1 Share
|
Re: Solar Energy, A Complement To FTA by mctfopt: 6:44pm On Jul 09, 2020 |
jmaine: Well, that makes lots of sense. Why import the Smartmi if you can get it here, right? Never knew him, I guess he (okaniudemba) is not that active in this section that is why I'm just seeing the username. |
Re: Solar Energy, A Complement To FTA by mctfopt: 6:45pm On Jul 09, 2020 |
Trippledots: Hard to miss that Still waiting for your cheap plug in third party shipping biz |
Re: Solar Energy, A Complement To FTA by jmaine: 6:51pm On Jul 09, 2020 |
mctfopt: Absolutely.... mctfopt: Yeah, he is not active in this section. he just does his stuff at the sides... stumbled on his offer on one of my rigorous Canadian solar price search/reviews... 3 Likes |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 7:50pm On Jul 09, 2020 |
jmaine: Chooi. Gennextech and co have smiling happily to the bank, selling 60k and above 3 Likes |
Re: Solar Energy, A Complement To FTA by jmaine: 7:52pm On Jul 09, 2020 |
earthrealm: Lolz... Such is life... 2 Likes |
Re: Solar Energy, A Complement To FTA by kadorzy(m): 7:56pm On Jul 09, 2020 |
Re: Solar Energy, A Complement To FTA by ojeysky(m): 8:30pm On Jul 09, 2020 |
ojtech8291: Is that a lithium battery? 1 Like |
Re: Solar Energy, A Complement To FTA by mctfopt: 8:57pm On Jul 09, 2020 |
earthrealm: That was my first thought too...some Nigerian company just love ripping off their customers for no reason at all. 2 Likes |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 10:05pm On Jul 09, 2020 |
PROMO! PLACE YOUR ORDER NOW!! - Quanta 200a 12v battery "white carton" ......147k per unit, 146,000(above 2 units) - Schneider homaya 1.5kva pure sinewave solar inverter .....75,000 - Axpert 3kva 24v pure sinewave solar inverter .....95,000 - Quanta 7a 12v ups, electric fence battery ...... 9,500 Contact, Smartcell global services CALL::: 081-350-31951 WHATSAPP::: https:///2348170385620 1 Like
|
Re: Solar Energy, A Complement To FTA by generalstingz(m): 10:10pm On Jul 09, 2020 |
8S 24V LFP BMS for grabs
|
Re: Solar Energy, A Complement To FTA by ojtech8291: 10:18pm On Jul 09, 2020 |
ojeysky:Gel Lead-acid Battery |
Re: Solar Energy, A Complement To FTA by Oshomo12(m): 4:56am On Jul 10, 2020 |
@Jmaine, u are a wonderful person to work with, I always enjoyed our talks. Enjoy our setup, U PAID for it. |
Re: Solar Energy, A Complement To FTA by jmaine: 5:26am On Jul 10, 2020 |
Oshomo12: Yeah, real fun times it was working together while having a good chat .. Looking forward to more collaborations with you... |
Re: Solar Energy, A Complement To FTA by ojeysky(m): 7:09am On Jul 10, 2020 |
ojtech8291: Okay, I have balancers for lithium |
Re: Solar Energy, A Complement To FTA by Monlo(m): 7:33am On Jul 10, 2020 |
Good day all. Take a look: https://www.nairaland.com/5980873/15000-nipost-workers-lose-jobs Just hope is not what am thinking.Because these guys have never one day disappointed me in terms of package delivery for the past 8 years I have been using their logistics...... Solar all the way. |
Re: Solar Energy, A Complement To FTA by mctfopt: 7:47am On Jul 10, 2020 |
Monlo: Same here, after 300+ package with non missing, I'll say NIPOST is doing well. Let's hope it never gets to them carrying out the threat of striking. |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 8:04am On Jul 10, 2020 |
You can never hope to balance out a 1v difference with a conventional lead acid balancer - these move on average about 1-5amps per label specs but in reality usually less than 1amp balancing current. Their biggest failure is that they use voltage equilibrium to approximate battery SoC balance and this is very very incorrect. What you should do is charge the batteries to full individually in 2 or 3 charge, discharge, recharge cycles and then put them back together again in series. If pressed for time, you can slap one standalone charger on each battery, set the charger absorb voltage above normal inverter absorb voltage and allow the chargers to individually charge each battery to full charge. You are doing this simultaneously e.g two separate 12v chargers attached to a live 24v battery system and charging each battery in tandem with inverter charging. The chargers can share thesame AC power source as inverter but you must never cross the DC inputs!!! If you do it correctly, the DC voltage of the chargers will at some point override the inverter's and take your weak battery on to a full charge. Run this over a few cycles and disconnect after you see the two batteries now staying in sync under discharge and also getting to fully charged within a few minutes of each other. If no positive changes after 10 cycles, then you have a permanent capacity mismatch that will never be fixed. You can no longer use your battery pair in series and must either purchase replacement batteries or switch to 12v in parallel. This procedure is simple and safe but requires a thorough understanding of the physics of electron flow in a DC circuit, do not attempt if in any way you feel afraid or incompetent to see it through. As a standalone 12v charger you can either purchase adjustable voltage smart 12v charger (if such exists locally) or as I do, use a laptop charger or AC/DC converter btw 15v to 22v DC voltage output - feed the DC output of your AC/DC charger into the PV input of a decent PWM controller and you have a DIY adjustable voltage smart 12v DC charger right there. Don't forget to set an appropriate charge algorithm on your PWM charger. ojtech8291: 4 Likes 1 Share |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 10:54am On Jul 10, 2020 |
RENEPV 340 WATTS BLACK MONO SOLAR PANEL AVAILABLE FOR ORDER!! PRICE : 53,000 Contact, Smartcell global services CALL::: 081-350-31951 WHATSAPP::: https:///2348170385620
|
Re: Solar Energy, A Complement To FTA by ojtech8291: 8:22pm On Jul 10, 2020 |
NiyiOmoIyunade:Thank you very much. Can the PWM charge controller current rating matter? Or the charger current rating? If so, what is the recommended current for the 12V200AH for faster charging? |
Re: Solar Energy, A Complement To FTA by ojeysky(m): 9:14pm On Jul 10, 2020 |
ojeysky: Still available 1 Like |
Re: Solar Energy, A Complement To FTA by bbally: 11:06pm On Jul 10, 2020 |
Oshomo12: God forbid, it was just one of those Sharp thunderstorm that sharply trip the power supply to the entire neighborhood while the inverter was charging and just like that, the inverter went bad. I will get the AC and DC SPD since I cant do digging of the compound to do earthing. |
Re: Solar Energy, A Complement To FTA by bbally: 11:28pm On Jul 10, 2020 |
mank1234: thanks, I guess the power guard is good enough for over and under voltage? |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 11:44pm On Jul 10, 2020 |
Ah boss! SPD is entirely useless and potentially even dangerous if there is no earth/ground to send the fault current to. Putting a copper rod in the ground for protective earth is not an elaborate affair as such - anywhere in the compound from where you can run cable to your own flat/house is alright. We have used flower bed, just beside a ground floor window, just outside the compound beside a gutter, side of wall or fence..... People just hammer the rod into the ground but this will only work with suitable soil - ideally you want to dig/auger a narrow hole like say 4 inches wide, put your copper rod in the center of the hole and backfill with suitable enhancement material - budget installs use industrial charcoal ground to a fine powder mixed with cement for a permanent earth. I would say 2 copper rods driven at least 16 feet apart is the minimum for safely channeling large surges from lightning e.t.c - if all you can do is one rod then it is better than nothing - just make sure it is the 8foot length type. If all else fails, you can bond to a large metal body that is firmly connected to earth e.g the metal work frame that carries an overhead tank, car port or the water corporation metal pipe buried horizontally several meters length. Half of my array is ground mounted sitting atop a large metallic frame embedded deep in the ground via 5 heavy duty concrete bases/legs - I did not bother to earth the frame the panels sit on as the entire assembly already has a firm connection to ground in Lekki saltwater soil. bbally: 4 Likes |
(1) (2) (3) ... (794) (795) (796) (797) (798) (799) (800) ... (1856) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: 2 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 70 |