Re: Solar Energy, A Complement To FTA by agent52(m): 11:24pm On Dec 12, 2020
Gurus in the house, pls My 100ah AGM battery makes a hissing or boiling sound when ever d voltage reaches 14.2 during charging....what can b d problem. Am using 250 watts single panel with pwn charge controller. this also happens when charging with a 20amp suoer battery charger .....
Re: Solar Energy, A Complement To FTA by Tolutopsy: 4:52am On Dec 13, 2020
Hi, I plan on installing a 2kva solar system in my apartment, could someone help me with an estimated cost to get this done?

Also, does one power his apartment only on the batteries, or can the apartment be powered directly, that is there's power in the apartment while the battery keeps charging?

1 Like

Re: Solar Energy, A Complement To FTA by mctfopt: 7:20am On Dec 13, 2020
agent52:
Gurus in the house, pls My 100ah AGM battery makes a hissing or boiling sound when ever d voltage reaches 14.2 during charging....what can b d problem. Am using 250 watts single panel with pwn charge controller. this also happens when charging with a 20amp suoer battery charger .....

I hope the battery is not being overcharged. Does this occur throughout the charging process?
Re: Solar Energy, A Complement To FTA by BetaTechnicians: 8:14am On Dec 13, 2020
mctfopt:


I hope the battery is not being overcharged. Does this occur throughout the charging process?

Possibly, it is most likely taking in more than 10A
Re: Solar Energy, A Complement To FTA by BetaTechnicians: 8:16am On Dec 13, 2020
Tolutopsy:
Hi, I plan on installing a 2kva solar system in my apartment, could someone help me with an estimated cost to get this done?

Also, does one power his apartment only on the batteries, or can the apartment be powered directly, that is there's power in the apartment while the battery keeps charging?

Start by telling the house what is in your apartment.
Re: Solar Energy, A Complement To FTA by Tolutopsy: 11:13am On Dec 13, 2020
BetaTechnicians:

Start by telling the house what is in your apartment.

18 energy saving bulbs in total ( their ratings are unknown)
My laptop rated 150w
A 32inch tv ( plan on getting a 55-60' later on)
Sound system (total max power 300w)
A standing cooler rated 65w
Refrigerator/freezer rated input 100w

That's all I have for now.

There's a future plan of getting a 1.5hp air conditioner and a 1hp air conditioner (I don't think I want to load that on the system tho, but maybe with the energy saving types they make now) and a front load washing machine.

Thanks.
Re: Solar Energy, A Complement To FTA by BetaTechnicians: 11:20am On Dec 13, 2020
kiekie1:


Hello ,
- Approx 1500 cycle on 30% DOD , 1300 cycle on 50
- It's an improved technology to the older lead acid , comes with thicker plates and accepts faster charging as entailed in snapshot below
- Yes distilled water which I also have available at affordable price !
This battery would also need the periodic equalization right?
Re: Solar Energy, A Complement To FTA by BetaTechnicians: 11:21am On Dec 13, 2020
Tolutopsy:


18 energy saving bulbs in total
My laptop rated 150w
A 32inch tv ( plan on getting a 55-60' later on)
Sound system
A standing cooler rated 65w
Refrigerator/freezer rated input 100w

That's all I have for now.

There's a future plan of getting a 1.5hp air conditioner and a 1hp air conditioner (I don't think I want to load that on the system tho, but maybe with the energy saving types they make now) and a front load washing machine.

Thanks.



What's the rating of each energy saving bulb? Add that detail too to your post.
Re: Solar Energy, A Complement To FTA by adrusa: 11:33am On Dec 13, 2020
NiyiOmoIyunade:
A 63A breaker is rated to carry 63A indefinitely - it may or may not trip at 70A.

The breaker response to current depends on the current response curve rating - Type A, B, C, D e.t.c Most of the breakers I see locally are C-Curve.

If you have a very rapid rise in amps over and above the rated current (such as a short circuit) then a breaker is likely to trip quickly. A slow and steady ramp up may not cause a trip.

See screenshots below for the various ratings and working tolerances.

This is one of the reasons why there is a market for those electronic voltage and current protection devices you sell since they have a much more precise response. I have yet to see a DC version though.



Good info.
Re: Solar Energy, A Complement To FTA by BetaTechnicians: 11:36am On Dec 13, 2020
mctfopt:


If you can closely match the open circuit voltage (VOC) of the 250/300w panel then you are good. Though you may lose some power due to mismatch, but your overall yield will be much better than running only the five 150watts.

So in practice, most VoC range of 150w is from 18v to 20v and that of 250w is from 36v to 40v. So if you connect two 150w in series and parallel it with the other two, you will have one left unconnected. You may need one more 150w to balance up the VoC then you can parallel with a 250w or 300w. The power loss then will be minimal. Still better than running only the five 150 watts cool

Or to avoid the headache, just buy more 150w or sell off the 150w and go full 300w or 250w.

Nice...
On a lighter note, I'm wondering why oga Niyi skipped this question but answered the one below it. Maybe because that one na Victron level smiley
Re: Solar Energy, A Complement To FTA by Tolutopsy: 11:38am On Dec 13, 2020
BetaTechnicians:

What's the rating of each energy saving bulb? Add that detail too to your post.

I don't know their ratings, but it's all these pop bulbs
Re: Solar Energy, A Complement To FTA by BetaTechnicians: 11:45am On Dec 13, 2020
omotoda:


They ain't located on same side.One is west while one is east but roof structure is virtually flat

I believe you were not able to use rails to mount your panels due to the asbestos roof right? But how were you able to hold them in place?
Re: Solar Energy, A Complement To FTA by kiekie1(m): 12:14pm On Dec 13, 2020
BetaTechnicians:

This battery would also need the periodic equalization right?

Yes Sir but electrolyte gasing losses are minimal since recommended equalisation charge voltage isn't even upto 14.9vdc .. Cheer's


Contact,
Smartcell global services
CALL:: 081-350-31951
WHATSAPP::: https:///2348170385620

Re: Solar Energy, A Complement To FTA by mctfopt: 2:27pm On Dec 13, 2020
BetaTechnicians:

Nice...
On a lighter note, I'm wondering why oga Niyi skipped this question but answered the one below it. Maybe because that one na Victron level smiley

grin
Re: Solar Energy, A Complement To FTA by earthrealm(m): 3:13pm On Dec 13, 2020
Who has in stock this variant of current limiter, with kwh display,?
I need it asap, cant wait for AE

1 Like 1 Share

Re: Solar Energy, A Complement To FTA by earthrealm(m): 3:18pm On Dec 13, 2020
agent52:
Gurus in the house, pls My 100ah AGM battery makes a hissing or boiling sound when ever d voltage reaches 14.2 during charging....what can b d problem. Am using 250 watts single panel with pwn charge controller. this also happens when charging with a 20amp suoer battery charger .....

You obviously are charging it beyond manufacturers charge voltage recommendation.
Is the agm battery quanta?... Its the make that easily comes to mind cos it has the lowest charge voltages i have seen.

Simply check the float and absorb sertings as written on your battery and set your charge controller and inverter accordingly
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 4:43pm On Dec 13, 2020
I have one new unit and one used.


earthrealm:
Who has in stock this variant of current limiter, with kwh display,?
I need it asap, cant wait for AE

1 Like

Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 4:45pm On Dec 13, 2020
So sorry boss, I missed it reading and typing from my phone. I actually read the thread backwards from the last post so my Nairaland time may run out before I see all posts.


BetaTechnicians:

Nice...
On a lighter note, I'm wondering why oga Niyi skipped this question but answered the one below it. Maybe because that one na Victron level smiley
Re: Solar Energy, A Complement To FTA by kiekie1(m): 12:22pm On Dec 14, 2020
USA TROJAN BATTERY AVAILABLE!

Get your trojan batteries with outstanding number of cycles and durability for your power inverter , solar ESS applications. Trojan above does; 1000 cycles at 80% DOD , 1700 cycles at 50% DOD , 3250 cycles at 40% DOD

Trojan 12v 205a .... N190,000

For enquiry or purchase,

Contact,
Smartcell global services
CALL:: 081-350-31951
WHATSAPP::: https:///2348170385620

Re: Solar Energy, A Complement To FTA by kiekie1(m): 12:26pm On Dec 14, 2020
earthrealm:
Who has in stock this variant of current limiter, with kwh display,?
I need it asap, cant wait for AE

63a Available at discounted price ..

Contact,
Smartcell global services
CALL:: 081-350-31951
WHATSAPP::: https:///2348170385620

Re: Solar Energy, A Complement To FTA by earthrealm(m): 12:46pm On Dec 14, 2020
kiekie1:


63a Available at discounted price ..

Contact,
Smartcell global services
CALL:: 081-350-31951
WHATSAPP::: https:///2348170385620

The specific one i require as attached has a 3rd element, kwh display.
Yours doesnt have it

1 Like

Re: Solar Energy, A Complement To FTA by wilmaria14: 1:05pm On Dec 14, 2020
Tolutopsy:


18 energy saving bulbs in total ( their ratings are unknown)
My laptop rated 150w
A 32inch tv ( plan on getting a 55-60' later on)
Sound system (total max power 300w)
A standing cooler rated 65w
Refrigerator/freezer rated input 100w

That's all I have for now.

There's a future plan of getting a 1.5hp air conditioner and a 1hp air conditioner (I don't think I want to load that on the system tho, but maybe with the energy saving types they make now) and a front load washing machine.

Thanks.


all dis for just 2kva setup boss?

5 Likes

Re: Solar Energy, A Complement To FTA by Tolutopsy: 1:28pm On Dec 14, 2020
Ah no sabi anything about am ni boss... I Sha want make light dey dey 24/7 grin
wilmaria14:
all dis for just 2kva setup boss?
Re: Solar Energy, A Complement To FTA by kiekie1(m): 2:05pm On Dec 14, 2020
earthrealm:


The specific one i require as attached has a 3rd element, kwh display.
Yours doesnt have it

All available Sir .. Cheer's
Re: Solar Energy, A Complement To FTA by kiekie1(m): 2:09pm On Dec 14, 2020
Fairly used 200a battery up for sale ..

Flatrate price: 55,000

Location : Abule egba, Lagos but can be waybilled to any state as usual under buyers expense.

Contact,
Smartcell global services
CALL:: 081-350-31951
WHATSAPP::: https:///2348170385620

Re: Solar Energy, A Complement To FTA by lat55(f): 2:33pm On Dec 14, 2020
The sheer madness!!! I don’t even want to get started. I have just accepted the sad reality that it takes me n every other willing individual to start off the change we want to see n we must do so in a timely fashion (especially in matters concerning basic human needs) else we will keep having people die from easily preventable causes while waiting on our govt to get their act together.


ceaser:


Citizens in a whole community who are likely mostly peasants having to provide something as basic as portable water for 'emselves.

And that yèyé government is concerned about one useless self serving "water resources bill".
Re: Solar Energy, A Complement To FTA by wilmaria14: 5:15pm On Dec 14, 2020
Tolutopsy:
Ah no sabi anything about am ni boss... I Sha want make light dey dey 24/7 grin
Ok but 2kva a will not carry all of dat try bring it up to 3,5kva
Re: Solar Energy, A Complement To FTA by saint2ace(m): 7:15pm On Dec 14, 2020
Tolutopsy:
Ah no sabi anything about am ni boss... I Sha want make light dey dey 24/7 grin


This is not realistic on ur budget and estimated load, except u're going solar and ur batter bank will be quite an investment.....
Re: Solar Energy, A Complement To FTA by saint2ace(m): 7:16pm On Dec 14, 2020
wilmaria14:
Ok but 2kva a will not carry all of dat try bring it up to 3,5kva


The capacity of the inverter is not the issue, the main issue here is the capacity of his battery bank for someone wanting 24hrs power
Re: Solar Energy, A Complement To FTA by wilmaria14: 7:51pm On Dec 14, 2020
saint2ace:



The capacity of the inverter is not the issue, the main issue here is the capacity of his battery bank for someone wanting 24hrs power
yes boss but if u give an inverter offer load it will kill it quick and it will always go off

(1) (2) (3) ... (908) (909) (910) (911) (912) (913) (914) ... (1783) (Reply)

FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread

Viewing this topic: dollarnaira, jmaine and 2 guest(s)

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 44
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.