Welcome, Guest: Register On Nairaland / LOGIN! / Trending / Recent / NewStats: 3,208,440 members, 8,002,626 topics. Date: Thursday, 14 November 2024 at 02:17 PM |
Nairaland Forum / Science/Technology / The Downstream Optical Amplifier Board Does Not Report MUT_LOS (1116 Views)
These Are Some Of The Strangest Optical Illusions Known To Science / In The Downstream Direction / Some Optical Ports Reported The IN_PWR_ABN Alarm Because Optical Modules Were No (2) (3) (4)
(1) (Reply)
The Downstream Optical Amplifier Board Does Not Report MUT_LOS by jorna: 4:13am On Apr 18, 2016 |
The downstream optical amplifier board does not report MUT_LOS when the service between the upstream optical amplifier board and the FIU board is interrupted. Product OptiX Metro 6100 OptiX Metro 6040 Fault Type Service Interruption Optical Power Abnormity Optical Multiplexer and Demultiplexing Unit Optical Amplifier Unit MUT_LOS Symptom The downstream optical amplifier board does not report MUT_LOS when the service between the upstream optical amplifier board and the FIU board is interrupted because of fiber jumper failure. Cause Analysis The transmit optical power of the SC2 ranges from 0 dBm to -4 dBm. The threshold for the downstream optical amplifier board to report MUT_LOS is -35 dBm. Assume that the transmit optical power of the upstream SC2 is -2 dBm. When the loss on the line side is no less than 19.5 dB (35-2-1.5-12, where 1.5 is the insertion loss of the FIU and 12 is the isolation of the FIU), the downstream optical amplifier board reports the MUT_LOS alarm. When the WDM equipment is used in a MAN, the line loss is normally smaller than 19.5 dB. In this case, the downstream optical amplifier board does not report the MUT_LOS alarm when there is a fiber cut between the upstream optical amplifier board and the FIU. Procedure Check the output optical power of the upstream optical amplifier board. The output optical power is within the normal range. Check the input optical power of the upstream FIU. The input optical power is very low. This indicates that the fiber between the optical amplifier board and the FIU is faulty. Replace the fiber between the upstream optical amplifier board and the FIU. Then, the services become normal. Reference Information None. |
(1) (Reply)
Ramadan Calendar 2016 Timings / Passenger Rescue Drone Airborne 'by 2020' / What’s The Difference Between 3G, 4G And LTE?
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 10 |