Re: Solar Energy, A Complement To FTA by twinskenny(m): 5:16pm On Jan 04 |
I need a used 1kva or 1.5kva inverter if you have for sale kindly quote me.. must be 12v |
Re: Solar Energy, A Complement To FTA by twinskenny(m): 5:27pm On Jan 04 |
emmy9500: Not all at the same time 1 Like |
Re: Solar Energy, A Complement To FTA by Akbil: 7:59pm On Jan 04 |
olopan: 3nos x 1.5hp ACs 18w x 15nos LED Light fittings, 5nos laptops, 40w x 8nos security lighting, 250l deep freezer, water treatment plant, microwave, 8nos x 55w standing fans etc etc 2 storey building. Roof top measures around 10m x 12m 1 Like |
Re: Solar Energy, A Complement To FTA by dacool1(m): 8:09pm On Jan 04 |
jikaseo: Tell us the power ratings of the gadgets you power. Whosoever advised you to power up a 5kva inverter with two 220ah battery needs flogging. You can only power about 300watts (total wattage of the appliances) with those batteries as your inverter will use up about 80watts doing nothing. My advice is you dispose those batteries and buy new ones atleast 4 batteries then double your panels. Ideally, you don't need more than a 1.7kva inverter. Plus don't you power bulbs, you need to factor in those things. In renewable energy, you energy supply is limited. Even common phone charger draws about 20watts. Get a proper energy audit done for proper advice. Those appliances you listed up there may consume about 400w in total and it's alot of power to be drawn from 2 tubular batteries. You will have just about 4 to 5 hours back up after sun down 6 Likes |
Re: Solar Energy, A Complement To FTA by Edrizz(m): 8:44pm On Jan 04 |
Yes, but u need to be sure that the panels are arranged facing the proper direction n more so get the total cumulation of ur load to ascertain that the DC energy generated is sufficient for use during sunny hours n at night jikaseo: 1 Like |
Re: Solar Energy, A Complement To FTA by olopan(m): 10:36pm On Jan 04 |
Thanks for the heads up, i'll see to it and revert back so you can make adjustments Akbil: |
Re: Solar Energy, A Complement To FTA by jikaseo(f): 12:52am On Jan 05 |
Total load is over 600watts. Edrizz: |
Re: Solar Energy, A Complement To FTA by jikaseo(f): 2:10am On Jan 05 |
Load is over 600watts. How about if I get a 2000watts sachet inverter with the two extra panels? I'm looking at optimizing the output with not much cost.. dacool1: |
Re: Solar Energy, A Complement To FTA by dacool1(m): 7:42am On Jan 05 |
jikaseo: Well, that might help improve your performance. Your freezer and other appliances should only be used during the day, you will have to reduce your "sun-down" loads to a max of 200w. If you are lucky not to have damaged your batteries your inverter should go off around 1 - 2am. In order to continuously power the load of over 600watts after sunlight till the next sun light you need a minimum of 10 220ah batteries. If you buy less than that be ready to replace your batteries in about 12 to 18 months. So my advice, power the heavy loads during the day and manage your load once it's sundown. Your current battery back up can only support a about 100w after sundown till the next sunlight. 2 Likes |
Re: Solar Energy, A Complement To FTA by ewizard1: 8:39am On Jan 05 |
dacool1:10 x 220ah batteries to power 600W load for about 20hours? 1 Like |
Re: Solar Energy, A Complement To FTA by jikaseo(f): 8:41am On Jan 05 |
Thank you so much for this insight. I'm so grateful. dacool1: 1 Like |
Re: Solar Energy, A Complement To FTA by dacool1(m): 9:41am On Jan 05 |
ewizard1: Actually that's for 14 hours. Is it too little or too much |
Re: Solar Energy, A Complement To FTA by sharks776(m): 3:47pm On Jan 05 |
Something happened about an hour ago where I went to buy felicity inverter at Garki modern market, Abuja for those that are familiar with the place. A man came to buy felicity lead acid battery 12v 200ah. He needed 2pcs for 24v system. He came with a battery tester exactly like the one shown below. The shop attendant brought two new batteries but after the test, one showed "good battery" while the second one showed "replace battery". The customer rejected the second battery and demanded a replacement which caused an exchange of words btw the shop and the customer as the shop owner refused replacing the second battery. My question is has anyone here ever used this battery tester and how reliable is it 1 Like
|
Re: Solar Energy, A Complement To FTA by Obnoxious2001(m): 4:53pm On Jan 05 |
sharks776: This battery Analyser is not accurate 1 Like |
Re: Solar Energy, A Complement To FTA by Jefferyzz(m): 5:11pm On Jan 05 |
Abeg Wu get connect of where I fit get sachet inverter. |
Re: Solar Energy, A Complement To FTA by chris81964(m): 5:15pm On Jan 05 |
Re: Solar Energy, A Complement To FTA by dollarnaira: 5:58pm On Jan 05 |
@juror Pls how do I get SRNE pwm cc? |
Re: Solar Energy, A Complement To FTA by Valto(m): 6:23pm On Jan 05 |
chris81964:no be small thing when i say most of the popular brand in Nigerian market are fake capacity and also used grade C cells, they will say i am a marketer and attack me. hope una de see am 3 Likes |
Re: Solar Energy, A Complement To FTA by sharks776(m): 7:06pm On Jan 05 |
https://youtube.com/shorts/0a_6CW609hg?si=8G3XchSSHpgq6KDf This is felicity battery as well using old cells |
Re: Solar Energy, A Complement To FTA by Olarewajub: 7:46pm On Jan 05 |
Good evening, house. So, for almost a year, I have been off the grid. But recently, I decided to connect back to the grid. My installer made a connection between the power from the grid and my inverter. So, if they take the light, it automatically switches to the battery power. Now, my dilemma is that I share a prepaid meter with four other (4) tenants. Would this connection not increase the electricity bill? PS: My panel is enough to charge my battery, except for this period, I don't get enough sunlight due to their orientation on the roof. I will switch back to off-grid in the coming month. |
Re: Solar Energy, A Complement To FTA by Valentinooo: 8:38pm On Jan 05 |
Olarewajub: It will increase it. That thing dey gulp prepaid like mad. Once in a while I use PHCN to charge my battery too and I notice a significant drop in my remaining unit. It also depends on your battery capacity sha. 4 Likes |
Re: Solar Energy, A Complement To FTA by Olarewajub: 8:53pm On Jan 05 |
Valentinooo: Thanks for the response. I will stick with manually using the changeover to switch between the inverter and PHCN. That way, my battery won't get charged with PHCN. |
Re: Solar Energy, A Complement To FTA by mctfopt: 9:01pm On Jan 05 |
sharks776: I have this tester, and I can confidently tell you it ain't reliable. 6 Likes |
Re: Solar Energy, A Complement To FTA by Jefferyzz(m): 9:02pm On Jan 05 |
Pls who has sachet inverter and AC charger seller contact |
Re: Solar Energy, A Complement To FTA by TechGeek777: 9:08pm On Jan 05 |
Jefferyzz: Boss, what happen to your Grovolt inverter? |
Re: Solar Energy, A Complement To FTA by mctfopt: 9:16pm On Jan 05 |
sharks776: Currently fighting with my Chinese battery supplier because he has only Grade B cells. So my people be buying Grade D cells in Naija 3 Likes |
Re: Solar Energy, A Complement To FTA by chris81964(m): 5:17am On Jan 06 |
chris81964:This video must have hit a sore spot. This is the fastest I have reached over 300 views in more than one year. There is a lot of pain in our market. A lot of deception too. Buyer beware. 1 Like 1 Share |
Re: Solar Energy, A Complement To FTA by ewizard1: 7:47am On Jan 06 |
mctfopt: IMO, Grade A cells aren't accessible to random end users. |
Re: Solar Energy, A Complement To FTA by ewizard1: 7:48am On Jan 06 |
dacool1: Pardon me... you're rigth! Was thinking it was too much! 1 Like |
Re: Solar Energy, A Complement To FTA by Jefferyzz(m): 7:59am On Jan 06 |
It's Ricco crown not growvolt boss. It's still working 5n o. I'm installing new system with lead acid n sachet inverter dey friendly with battery consumption. I think 5w TechGeek777: 1 Like |
Re: Solar Energy, A Complement To FTA by dollarnaira: 8:04am On Jan 06 |
Pls who is currently using a pwm cc for any lithium? I need the brand name of one urgently. Pls share! |
Re: Solar Energy, A Complement To FTA by mctfopt: 9:21am On Jan 06 |
ewizard1: sellers ain't lying. just pushing my luck 1 Like |
(1) (2) (3) ... (1541) (1542) (1543) (1544) (1545) (1546) (1547) ... (1855) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: Ntente(m), idsolar(m), kewhos(m), omonla5, amicdan(m) and 7 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 51 |