Re: Solar Energy, A Complement To FTA by Alejoc(m): 6:16pm On Jul 15, 2018 |
Pls I have some Suoer 350watt Inverter showing red fault light not supplying power.....pls what could be wrong with these inverter.... They were previously working before showing the faulty red light and I have adjusted the cable several times already with no success |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 7:30pm On Jul 15, 2018 |
I have been attempting to DIY an automatic transfer switch and testing the device in three locations - two out of three are working good but the third location suffers from chronic low mains voltage (relay coil rated 220v sees 172v to 180v from PHCN) and this causes 'chattering' and ultimately the relay burns out. I have attached a rough schematic and actual picture below - you will see from the schematic that I shorted signal/coil (live from PHCN) to Common on the source side and shorted NC to NO on the load side since I am using two separate power sources (Mains from PHCN has priority and inverter with timer attached for fixed hours of run time if no mains) to power one load. I became concerned how the switch/relay chattered and failed when subjected to low voltage far below the coil rating and I am thinking of a way to handle this fault condition gracefully - the only thing I could come up with is a circuit breaker on the mains side closer to the relay even though the live wire feed from PHCN is already protected at the distribution board same for the inverter output. Suggestions and ideas on how to make this work safely are welcome - the schematic only shows the live wires being switched and then common neutral being done outside the switch for simplicity.
|
Re: Solar Energy, A Complement To FTA by pranil(m): 7:48pm On Jul 15, 2018 |
NiyiOmoIyunade: it is rather simple. Buy a 12 V coil relay and ded the coil through aAC /DC power supply ( you can find one easily ) popularly known as battery eliminator I do this for all my control circuits as it makes them safe to handle. also the 12 V control parts are cheaper and easier to find on both continents ( US , UK ) alternatively, use this which has batter contact rating for mains then the omron one you are using as it is nor rated to pen inductive loads https://www.aliexpress.com/item/CJX2-CJX2-0910-LC1-ac-contactor-24V-AC-9A-50HZ-60HZ-orginal-lc1-0910-24v-free/856880658.html every contractor has duty cycle and for load changeover you need 7-A or 7 B duty cycle to ensure long life https://en.wikipedia.org/wiki/Utilization_categories |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 8:32pm On Jul 15, 2018 |
Many thanks Oga Pranil Introducing an AC/DC power supply to energize the coil is another possible point of failure which I want to avoid if possible. And yes I will use a beefy contactor if I plan to switch large loads although that 10a rated Omron relay is rated for 2a of inductive loads I think. Would a circuit breaker in line help interrupt the power if the contacts begin to chatter and avoid catastrophic failure? One interesting thing I found in my experimentation is that the relays seemed to achieve nearly instantaneous changeover even better than normal inverter transfer times - 8ms per the spec sheet with most loads including a fridge not even noticing the changeover but it is much slower when using a contactor. pranil: |
Re: Solar Energy, A Complement To FTA by BRIGHTSOLAR(m): 8:38pm On Jul 15, 2018 |
DROPSHIPPING AND ONLINE DELIVERY OF RENEWABLE ENERGY MATERIALS INVERTER MICROTECH INVERTER 900VA,12V N46,000 1.1KVA,12V N53,000 1.6KVA/24V N72,000 2KVA/24V N80,000 2.6KVA/36V N105,000 3.6KVA/48V N170,000 5.2KVA/48V N340,000. 5.5KVA/96V N340,000 10KVA/180V N790,000 PRAG INVERTER 1.1KVA,12V N70,000 1.2KVA,12V N90,000 1.5KVA/24V N110,000 2.5KVA/24V N125,000 3KVA/24V N170,000 4KVA/48V N320,000. 5KVA/96V N300,000 7.5KVA/120V N500,000 710KVA/180V N600,000 KELVIN INVERTER 2.5KVA/36V N125,000 2.5KVA/48V N125,000 3 KVA/48V N170,000 5KVA/48V N340,000. 5KVA/96V N290,000 7.5KVA/120V N550,000 10KVA/180V N750,000 MUST POWER STAR INVERTER 4kva 3000W 24V N 220,000 4kva 3000W 48V N 260,000 5kva 4000W 48V N 350,000 6kva 5000W 48V N 400,000 7.5kva 6000W 48V N 450,000 HYBRID INVERTER VOLTRON SERIES 1.4KVA/12(30A N65,000 2.4KVA/24V50A N97,000 3KVA /48V 60A MPPT N220,000 5KVA /48V 60A MPPT N310,000 7.5KVA /48V 60A MPPT N430,000 10KVA /48V 100A MPPT N750,000 15KVA /48V 60A MPPT N850,000 15KVA /48V 120A MPPT N890,000 STABILIZER VOLTRON SERIES 6KVA WALL MOUNT RELAY REGULATOR #45,000 6KVA WALL MOUNT SERVO REGULATOR #65,000 12KVA WALL MOUNT RELAY REGULATOR #90,000 12KVA WALL MOUNT SERVO REGULATOR #120,000 BATTERY GENEX BATTERY 12V/200AH N 120,000 LONG BATTERY 12V/200AH N 120,000 MONBAT BATTERY 12V/200AH N 125,000 MONBAT BATTERY 12V/210AH N 120,000 ELSON BATTERY 12V/200AH N 115,000 MICROTEC BATTERY 12V/200AH N 105,000 EASTMAN 12V/200AH TALL TUBULAR BATTERY N115,000 GLT BATTERY 12V/200AH N 90,000 ZEEDIX BATTERY 12V/200AH N 90,000 RITAR BATTERY 12V/200AH N 125,000 PRAG BATTERY 12V/200AH N 140,000 PATTERN BATTERY 12V/200AH N105,000 QUANTA BATTERY 12V/200AH N 130,000 BATTERY RACK BATTERY RACK 2 BATTERY N 15,000 BATTERY RACK 4 BATTERIES N 30,000 BATTERY RACK 8 BATTERIES N 50,000 CHARGE CONTROLLER ROY SOLAR SERIES 20A 12/24V PWM CONTROLLER N 20,000 30A 12/24V PWM CONTROLLER N 25,000 40A 48v PWM controller (LED) N 50,000 30A 96v PWM controller (LCD) N 120,000 60A 48v PWM controller (LCD) N 95,000 COWIN SERIES 20A 12/24V PWM CONTROLLER N 15,000 30A 12/24V PWM CONTROLLER N 20,000 40A 12/24V PWM CONTROLLER N 25,000 50A 12/24V PWM CONTROLLER N 32,000 60A 12/24V PWM CONTROLLER N 41,000 40A 48v PWM controller (LED) N 25,000 50A 48v PWM controller (LED) N 32,000 60A 48v PWM controller (LED) N 50,000 COWIN MPPT SERIES 40A 12/24/48v MPPT controller (LCD) N 80,000 60A 12/24/48V MPPT controller (LCD) N 130,000 EPEVER MPPT SERIES 12/24/48 /45A N 145,000 12/24/48 /60A N165,000 FANGUNPSUN MPPT SERIES 30A 24V N40,000 60A 48v N140,000 80A 48v N170,000 SOLAR PANELS JOY SOLAR PANEL 150w MONO -N32,000 200w MONO -N33,000 260w MONO -N54,000 320w MONO -N73,000 TRINA SOLAR PANEL 300w MONO -N85,000 320w MONO -N110,000 YINGLIN SOLAR PANEL 100w POLY -N22,000 150w POLY -N33,000 200w POLY -N39,000 260w POLY -N51,000 310w POLY -N62,000 100w MONO-N25,000 150w MONO -N33,000 200w MONO -N39,000 260w MONO -N59,000 320w MONO -N74,000 CANADIAN SOLAR PANEL MONO- 290w. N60,000 330w. N66,000 POLY 270w. N45,000 275w. N59,000 ACCESSORIES PROGRAMMABLE Digital timer 15A N7,000 PROGRAMMABLE Digital timer 25A N9,000 BATTERY BALANCER DIGITAL HA02 48V 35K BATTERY BALANCER ANALOGUE HA02 48V 28K DC CIRCUIT BREAKER 63A/120V---500V 2 POLE N 8,000 DC CIRCUIT BREAKER 125A/500V 2 POLE N 14,000 DC TV 17INCHES DC TV 31,000 24INCHES DC TV 40,000 28INCHES DC TV 48,000 32INCHES DC TV 65,000 DC IRON 150WATTS 9,000 DC IRON 300WATTS 15,000 COMPLETE SOLAR SOLUTION Call-07058562938 Bright Solar Power WHATSSAP 08187995847 FOR PURCHASE/ DELIVERY INSTALLATION NATIONWIDE https:///send?phone=2348187995847 |
Re: Solar Energy, A Complement To FTA by makavele: 8:55pm On Jul 15, 2018 |
work in progess,,,stay tuned
|
Re: Solar Energy, A Complement To FTA by mank1234(m): 10:29pm On Jul 15, 2018 |
makavele: With this picture a work of 10min may turn to 1hr. 2 Likes |
Re: Solar Energy, A Complement To FTA by makavele: 1:14am On Jul 16, 2018 |
mank1234: lol |
Re: Solar Energy, A Complement To FTA by makavele: 1:31am On Jul 16, 2018 |
still tryna make a decision; along came the bus bar. . . can handle 200A of current
|
Re: Solar Energy, A Complement To FTA by makavele: 1:32am On Jul 16, 2018 |
Inverter mounted; thanks for wifey who helped me drill...
|
Re: Solar Energy, A Complement To FTA by makavele: 1:33am On Jul 16, 2018 |
found a board; cut it to shape and mounted it. . stripped a little bit of the edge by accident but will cover it up later
|
Re: Solar Energy, A Complement To FTA by makavele: 1:34am On Jul 16, 2018 |
Now the calculation and drawings to make sure everything is dead center and accurate. dont blame me, i am a perfectionist and i love it so
|
Re: Solar Energy, A Complement To FTA by makavele: 1:35am On Jul 16, 2018 |
And it's taking shape 1 Like
|
Re: Solar Energy, A Complement To FTA by makavele: 1:36am On Jul 16, 2018 |
Moving ahead
|
Re: Solar Energy, A Complement To FTA by makavele: 1:37am On Jul 16, 2018 |
It was past 12 am by now and i gotta be at the office tomorrow; so i quit here; will continue in the evening.
|
Re: Solar Energy, A Complement To FTA by makavele: 1:40am On Jul 16, 2018 |
In retrospect; this was how I started. Do not despise the days of little beginnings 2 Likes
|
Re: Solar Energy, A Complement To FTA by richmon74(m): 1:44am On Jul 16, 2018 |
ANEB: only one advice for you; NO LOAD CONSUMPTION IS OVER 200W 2 Likes |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 3:59am On Jul 16, 2018 |
makavele: Beautiful 1 Like |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 4:08am On Jul 16, 2018 |
Contact us for neat and proffesional installations of cctv, inverter and solar panels for organisations, home and offices... Call/whatapp 08117398294 for proffesional consult Email - Info@monzpowersolutions.com Instagram- @monzpowersolutions 1 Like
|
Re: Solar Energy, A Complement To FTA by kiekie1(m): 8:26am On Jul 16, 2018 |
makavele: Lovely ! I can see them all ready for action .. Observe the wall mounted 5kw psw inverter is very firm on wall ! Goodluck ! |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 8:27am On Jul 16, 2018 |
Must Power Star Light inverters with LCD display 1000w 12v=87k 1500w 12v=97k 3kva(2000w)-12v=115,000 4kva(3000w)-24v=150,000 5kva(4000w)-24=200,000 6kva(5000w)-24/48= 230,000 7.5kva(6000w)-24/48= 250,000 EP Solar 12/24/36/48v 60a mppt(i tracer) solar charge controller @ 127k EP Solar 12/24v 40a MPPT(a series ep ever) solar charge controller @ 70k Trojan 12v 200a J200re USA flooded batteries @ 129k...(limited quantity in stock) Trojan 12v 205a agm batteries ... 164k Trojan 6v 375a agm battery .... Arriving soon USA Mnspd DC / AC ..... 50k Schneider DC SPD ..........30k Quanta Amaron 12v 200a vrla battery @ ...125k Long battery 12v 200a agm battery @..... Solution battery 12v 200a agm battery @82k Flames 300w mono .... 47k Watts meter "kill-a-watt meter" ....9k Yachi solar panels ; 150w poly panels........@35k 260w poly panels.......@47k "limited stock" 310w poly panels........@58k "limited stock" DISCOUNTED PRICES ! CALL US NOW !! Magnum 4348 USA inverter ....@900k Victron multiplus 3kva 48v .....@600k Canadian 330w solar panel.....@65,500 bulk price Sunshine solar modules : 130w poly 23000 250w poly 39000 300w Mono 52,000 Protek 200L solar water heater...245k With 30k , I can offer you a set of pro solar roof mounts including ; 2 qty solar mount rail "4200mm" , 4 qty rack end clamp, 6 qty mid clamp, 6 qty L feet with rubber & special screw.... Same goes to angle positioning solar kits; - Adjustable front leg - Adjustable rear leg - Rail splice kit - Grounding lug *AUTHORISED DEALER PRAGMATIC TECHNOLOGIES* All our prag products comes with reliable warranty *AUTHORIZED DEALER INDIAN INVERTERS / BATTERIES ... Luminous PRODUCTS* All our products come with 1 year Warranty *AUTHORIZED DEALER SOLAR SHOP LTD PRODUCTS* All our products come with 1 year Warranty For best affordable prices , contact Smartcell Global Services,Lagos Nigeria. Simply call Sir Frankie "08135031951" for purchase,fast delivery and waybills .. Thanks !! |
Re: Solar Energy, A Complement To FTA by makavele: 8:41am On Jul 16, 2018 |
kiekie1: Very heavy on hand, but feels like paper when hanged, It's a beast though! |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 9:12am On Jul 16, 2018 |
Great work boss. I have said it before and I'll say it again - your DIY skills are above par - many a professional installer would be unable to do such a neat job as you have done - all aesthetics to be sure but a key and desirable aspect of the job regardless. A few observations/questions if I may; 1) DC Bus bar placement - I hate to see the +ve and -ve so close together - think what could happen in the event of an inadvertent or malicious short!!! e.g you tightening something with a spanner and spanner slips - your entire battery bank would be dumped through the short with disastrous results. My reco is to saw that wooden base in half and relocate one terminal at least 2 feet away. 2) What are those two 13amp sockets on the wooden board meant to power or do? 3) White breaker like device - is that some sort of SPD or just a circuit breaker or combiner box? Please tell us more about it as I couldn't make out the details on it makavele: 5 Likes |
Re: Solar Energy, A Complement To FTA by ANEB(m): 9:49am On Jul 16, 2018 |
Thanks alot. That's really helpful richmon74: |
Re: Solar Energy, A Complement To FTA by makavele: 10:11am On Jul 16, 2018 |
NiyiOmoIyunade: Thank you sir! Do not fret for the busbars will be encased in 2 different compartments, i can access one terminal to screw and unscrew while the other remains closed. But after careful thought, i think i best follow your method, a very easy way out. The 13 amp sockets, just wait for it. You will see. The white box; just a fanciful changeover switch to replace the commonplace knife switch. i am beginning to fear for lack of space on the main board so as I continue to install, i will make deletions and/or modifications. Should round up today though. Thanks |
Re: Solar Energy, A Complement To FTA by makawhy201: 9:49pm On Jul 16, 2018 |
Oga Bright solar, what is the diff btw battery balancer Ha02 analogue and digital? BRIGHTSOLAR: |
Re: Solar Energy, A Complement To FTA by makawhy201: 10:21pm On Jul 16, 2018 |
A very neat job, DIY like a professional..i observed the breaker carries +ve of PV and Battery...is knife switch not better than the socket you introduce to break off d PV before putting ON the PV/batt breaker? Jst saying. I completed my PV upgrade last week but robot has been banning and deleting my reviews, dont knw why. makavele: |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 8:26am On Jul 17, 2018 |
Its amazing to know your individual batteries are doing great just with the help of individual battery LCD monitor .. The battery balancer has duo functions ; -works on SOC mode -works on DOD mode Therefore, it works whilst the batteries undergoes charging and also whilst in use (backing up) as illustrated in night snapshot below.... Feel free to contact us for your LCD designs and battery equalizer in 24v & 48v specs. Smartcell global services 081-350-31951 1 Like
|
Re: Solar Energy, A Complement To FTA by kiekie1(m): 8:27am On Jul 17, 2018 |
makavele: Good stuff ! Keep us updated Sir ......... |
Re: Solar Energy, A Complement To FTA by CAROLYN19: 11:45am On Jul 17, 2018 |
Call us on 08066332919
|
Re: Solar Energy, A Complement To FTA by Barezzi(m): 3:46pm On Jul 17, 2018 |
Nice one Makavele. Any updates? |
Re: Solar Energy, A Complement To FTA by makavele: 5:01pm On Jul 17, 2018 |
2 Likes |
(1) (2) (3) ... (433) (434) (435) (436) (437) (438) (439) ... (1821) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: 2 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 77 |