Re: Solar Energy, A Complement To FTA by loluskysat(m): 11:44am On Jun 28 |
FRESHTWANYE: Check if the inverter is modified sine wave inverter. The waves generated by the inverter can interfere with the heart beat. Try using PSW if its MSW. |
Re: Solar Energy, A Complement To FTA by loluskysat(m): 11:56am On Jun 28 |
RickyM: Relocate your inverter, CC and batteries to a location that is less prone to lightning. Avoid places directly facing the window or high places. |
Re: Solar Energy, A Complement To FTA by SaintUlot: 12:08pm On Jun 28 |
SaintUlot: Sold 1 Like |
Re: Solar Energy, A Complement To FTA by FRESHTWANYE: 12:31pm On Jun 28 |
Obnoxious2001:
|
Re: Solar Energy, A Complement To FTA by FRESHTWANYE: 12:39pm On Jun 28 |
loluskysat:The inverter is pure sine wave because every other inductive load work perfectly. It strange to me am just thinking maybe inverters generate EMI( Electromagnetic interference) |
Re: Solar Energy, A Complement To FTA by obitobe: 1:20pm On Jun 28 |
FRESHTWANYE: some mercury 2.4kva inverter are modified sine wave and not pures sine wave, so that could be what might be affection the other decoder |
Re: Solar Energy, A Complement To FTA by loluskysat(m): 1:43pm On Jun 28 |
FRESHTWANYE: Can you try using a PSW inverter? |
Re: Solar Energy, A Complement To FTA by FRESHTWANYE: 1:50pm On Jun 28 |
obitobe:Thanks but the inverter is pure sine wave because i have ups msw and i know the difference from my fans with the humming sound from the ups but the inverter run the fans smoothly with no noise just like nepa or grid. Please is anyone using inverter for dstv extraview, please share your opinion or experience |
Re: Solar Energy, A Complement To FTA by Drgreatone: 3:11pm On Jun 28 |
SaintUlot:Finally, Congrats.. 6 Likes |
Re: Solar Energy, A Complement To FTA by dollarnaira: 5:12pm On Jun 28 |
ojesymsym: Jinko pv available. Confirm the originality yourself before payment. Pay on delivery LAGOS ONLY. Products are from Fouani direct. 475 145k 555 160k 580 175k 625 185k |
Re: Solar Energy, A Complement To FTA by Ferdiwar: 7:11pm On Jun 28 |
Always detailed and on point. Kudos. jonescosmos: 5 Likes |
Re: Solar Energy, A Complement To FTA by Mud3x(m): 8:33pm On Jun 28 |
Good evening senior men, I have 6kw growatt and I'm trying to understand the mppt The maximum volt is 500 Is the 500vdc limited to each string or both strings on the inverter? For example, 330v for pv1 string and 330v for pv2 string or 330v shared among both strings? |
Re: Solar Energy, A Complement To FTA by mank1234(m): 9:00pm On Jun 28 |
jonescosmos: 1 and 2 is going overboard. Lightening do also happen before it rain and sometimes while grid is ON. 3-5 is where he should focus his energy. I would suggest he check the following: -if his thunder arrestor is properly earthed. There's a building that the tape was cut during renovation and they kept experiencing what he's experiencing until it was fixed. -if house earthing is separate from thunder arrestor earthing. Bonding means the discharge appear briefly as voltages at grounding terminals. So SPD is needed to keep this potential within limit. -if thunder arrestor cabling is running in close proximity to any of his power line. This causes induced voltages/flash over on the power line. -if he has SPD. To electronics, having thunder arrestor without SPD is more dangerous than not having thunder arrestor at all. Also, having SPD incorrectly installed causes harm rather than removing it. 1 Like |
Re: Solar Energy, A Complement To FTA by Dam5reey(m): 9:19pm On Jun 28 |
Mud3x: It has 2 independent trackers 500V each and is limited by 16A input current. MPPT Solar Charging Mode Max. PV Array Power 4000W+4000W Max. PV Input Current 16A+16A Start-up Voltage 150Vdc±10Vdc PV Array MPPT Voltage Range 120Vdc~450Vdc Max. PV Array Open Circuit Voltage 500Vdc |
Re: Solar Energy, A Complement To FTA by RickyM: 9:58pm On Jun 28 |
zeestone99:I’m using the system for business for ice making so turning it off when I’m not at home means it will set it back for certain hours. |
Re: Solar Energy, A Complement To FTA by RickyM: 10:00pm On Jun 28 |
jonescosmos:My installation is off grid completely and not connected to grid. Can I have your contact? |
Re: Solar Energy, A Complement To FTA by jonescosmos(m): 10:13pm On Jun 28 |
Check my signature RickyM: |
Re: Solar Energy, A Complement To FTA by Mud3x(m): 10:53pm On Jun 28 |
Dam5reey: Thank you |
Re: Solar Energy, A Complement To FTA by Mud3x(m): 11:04pm On Jun 28 |
Dam5reey: I noticed the 5kw growatt has 18A input current and 450vdc and some models has 22A While 6kw growatt has 16A |
Re: Solar Energy, A Complement To FTA by obitobe: 9:01am On Jun 29 |
Please i need expert knowledge here, i have four 220ah tubular battery, i just noticed that when the battery is fully charge and i start using it for the night, @136w(5pm-10pm) and 98w ( 10pm -7am). i noticed that the battery will be 24.2v @2-3am then between 3-4am the battery voltage drops to 23.4v and this will get me to the morning. Recently i had to set the battery SOC from 50% to 70% because at 50% the battery goes off at 5-5:30am but at 70% it takes me till the morning. What could be causing the sharp drop in voltage. With a battery monitor, i am getting this readings in the morning Batt 1: 11.95v Batt 2: 10.99v batt 3: 10.95v Batt 4: 11.94v |
Re: Solar Energy, A Complement To FTA by brightk(m): 9:11am On Jun 29 |
mank1234:if lightning arrestor earth pit is different from house earthing pit, do you subscribe to bonding both earth pits together to keep the potentials as low as possible? If no do you prefer one earth pit for both house earthing and lightning? Would you use one. Earth rod for ac and dc spds? |
Re: Solar Energy, A Complement To FTA by mahkanjuh: 9:52am On Jun 29 |
Please house, how good is welion inverter wants to get a 1kva hybrid with 40mppt charge control for an 1000ah lithium battery |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 9:55am On Jun 29 |
RickyM:If that's the case you have to invest in proper earthing and thunder arestor equipment |
Re: Solar Energy, A Complement To FTA by Edrizz(m): 9:56am On Jun 29 |
With the individual battery voltage u shared, nothing is actually wrong with ur system, u only need to add/install a battery equaliser/balancer to ur system n everything will be fine. Ur 48volt inverter will continue to run provided that the battery voltage is still above 10.5v per piece, once the inverter detects a voltage drop of below 10.50v it would off itself... ur installer ought to have equalised the battery before installing them though obitobe: 1 Like |
Re: Solar Energy, A Complement To FTA by obitobe: 10:03am On Jun 29 |
Edrizz: Thank you for your response, i have battery equalizer installed to the batteries and also the system is a 24 voltage system. I thought my batteries were already getting weak. |
Re: Solar Energy, A Complement To FTA by Edrizz(m): 10:15am On Jun 29 |
obitobe: Recheck n confirm that the battery equaliser is installed correctly cos I don't see it performing it functions of equalising the battery voltage according to the voltages u shared earlier.... ordinarily you're not suppose to have any disparity between the battery voltages... |
Re: Solar Energy, A Complement To FTA by mank1234(m): 10:42am On Jun 29 |
brightk:Personally, I'll do lightening arrestor earthing separate from house earthing. I'll put house AC and DC on same earthing. However, panel frame would have a separate one or go with thunder arrestor earthing with a different wire conection. My logic: anything that would have contact with lightening, I wouldn't put it with my house earthing. If you want to go with texbook recommendation, you'll then use bare copper tape or wire to bond them together inside ground. Personally I wouldn't do the last part - because I don't have a means of checking how good the earthing is. The above would protect the house but is not enough to protect sensitive equipments. You still need an SPD to be connected in the manner of the picture below, taking note to ensure that the total distance of Va and Vb is less than 50cm. Taking your supply directly from the terminals of the SPD (live, neutral and earth) makes Va+Vb to be zero, thus ensuring that connected equipment won't see voltage above Up of the SPD. It's assume the supply has a suitable breaker upstream. SPD to be selected at the point of protection for AC should be one with Up of 1500V or less, Un of 275V. For DC, Un of your controller limit, Up of 2200V or less if HV controller or Up of 1500V or less if 200V controller and below. Computer and most electronics with processors have withstand voltage of 1500 while HV controllers have 2500V.
|
Re: Solar Energy, A Complement To FTA by Sapiosexuality(m): 12:27pm On Jun 29 |
Please, is this odour an inverter produces when it sound increases normal? What is responsible for the smell? It only happens once the sound increases suggesting, to me, a heating problem. I've been perceiving the smell from day 1. It comes out from the fan area of the inverter. |
Re: Solar Energy, A Complement To FTA by swagifted(m): 12:41pm On Jun 29 |
people using the felicity 5kw hybrid inverter......any of you have any one that have lasted 2 years and counting with zero issues? |
Re: Solar Energy, A Complement To FTA by GloriousGbola: 12:44pm On Jun 29 |
mank1234: Unless your earthing is done but professionals it will not be tested so you have no idea how reliable it is. People have had instances where lighting current goes to ground encounters resistance and then goes back into your home electrical installation. So it is preferable to put your lighting arrester seperate. Also note that unless your house is actually the tallest in the area, you may never have a lightning strike I also advise that you install the arrester not on your building but in your detached overhead water tank gantry. That way you don't have to worry about surge currents induced by lighting current. |
Re: Solar Energy, A Complement To FTA by Syber(m): 5:05pm On Jun 29 |
... 1 Like |
Re: Solar Energy, A Complement To FTA by emyfine08: 6:56pm On Jun 29 |
Syber: How many v 24v or 48v |
(1) (2) (3) ... (1755) (1756) (1757) (1758) (1759) (1760) (1761) ... (1853) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: adrusa
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 77 |