Re: Inverter Users : Lets Have Your Experience by coderXO(m): 8:51pm On Nov 12, 2015
It depends at what rate the battery charger/inverter charges at.

The higher the charge rate (10A, 20A, 30A, 40A), the larger the power needed to run it.

Think of it like an AC.
Re: Inverter Users : Lets Have Your Experience by spinola: 8:36am On Nov 13, 2015
A small price to pay! mercurydirect.com.ng

Re: Inverter Users : Lets Have Your Experience by kiekie1(m): 11:07am On Nov 14, 2015
kiekie1:
HURRY ! HURRY !! DISCOUNT SALES !!!!!!

USA TROJAN L16-RE Premium Line Flooded Lead Acid Battery 6V (410AH)20hr Rate ..... @ 75k

USA TROJAN J185P-AC Signature Line Flooded Lead-Acid Battery 12V (205AH) 20hr Rate .... "NOW IN STOCK"....@65k

Distilled water for flooded batteries ... 5L upwards

Solarworld mono panels 255w ,260w,265w "made in Germany" etc now in stock at very discounted prices.........

JOY SOLAR MODULES

POLY SOLAR PANEL:
80W N10000. 100W N13500. 120W N16000. 130W N16500. 160W N23000. 170W N25000. 180W N26000. 250W N30000. 280W N40000.

MONO SOLAR PANEL:
80W N12000. 100W N15000. 110W N15500. 120W N18000. 130W 20000.180W N28000.

Latest model 10kva wall mount servo stab (AC input range 80V-270V)....... @50k

Must power star light inverters with charge current adjustable variable,LCD display,wall mount,remote port,load wattage display,flooded/gel/agm battery settings,battery equalisation and desulphation settings...
1kw 12v =50k
1.5kw 12v =60k
2kw 12v =75k
2kw 24v =75k
3kw"4kva" 24v =120k
4kw 24v/48v =140k
5kw 24v/48v =160k
6kw"7.5kva"24/48v=210k
8kw 192v. =350k
10kw 96v. =380k

Must power inverter boards ...@25k

Programmable timer switch with LCD display 220vac 16a........ @4k

The EP Solar "I TRACER" 60a mppt controller is simply rugged compared to Morningstar price and has excellent features like: -inbuilt LCD display,
-high efficiency energy harvest with advanced mppt algorithm
-dual core (ARM CPU+DSP) control architecture
-run data and event recording
-multi phase synchronous rectification tech realizing peak conversion efficiency 98%
-high reliabilty including reverse connection, over current and load short protection etc
-diversified load control mode
-monitor software supplement and firmware update
-extensive communication capabilities (RS232, RS485 with modbus protocol, CAN bus extendable)....@


*AUTHORIZED DEALER SOLAR SHOP LTD PRODUCTS*
All our products come with 1 year Warranty

For best affordable prices,contact Smartcell Global Services,Lagos Nigeria. Simply call Sir Frankie "08135031951" for purchase,fast delivery and waybills .. Thanks !!!

Good morning all, Trojan J185p is almost out of stock... Thanks and remain blessed !
Re: Inverter Users : Lets Have Your Experience by Nobody: 1:09am On Nov 18, 2015
how many hours does it take to charge two inverter batteries with 2.4kva inverter?
Re: Inverter Users : Lets Have Your Experience by KOLAPO3(m): 5:49am On Nov 18, 2015
teeowl:
how many hours does it take to charge two inverter batteries with 2.4kva inverter?

I am also having some challenges with my mercury 2.4 inverter and 2 genus batteries 200ah. I purchased the system 3months ago
Since phcn has been better over the last 3 months in my area I have enjoyed the set up.
But now things are back to a bad state.i have a lot of questions. It takes almost 24hrs to get the batteries charge to full.
Eg 7 hours of charge (5hrs generator 2 Nepa)
Only lasted for 3hrs with just 2 ceiling of fans
I am really confused
Please help
Re: Inverter Users : Lets Have Your Experience by Nobody: 6:52am On Nov 18, 2015
how many KVA is your generator?


KOLAPO3:


I am also having some challenges with my mercury 2.4 inverter and 2 genus batteries 200ah. I purchased the system 3months ago
Since phcn has been better over the last 3 months in my area I have enjoyed the set up.
But now things are back to a bad state.i have a lot of questions. It takes almost 24hrs to get the batteries charge to full.
Eg 7 hours of charge (5hrs generator 2 Nepa)
Only lasted for 3hrs with just 2 ceiling of fans
I am really confused
Please help
Re: Inverter Users : Lets Have Your Experience by Nobody: 7:14am On Nov 18, 2015
Spinola, I have gone to that website. My questions are:
1.) How many hours does it take to charge Mercury 1.2kva Complete Inverter System using a 2.5kva generator - FULL CHARGE
2.) How long can 3 ceiling fans last after full charge on Mercury 1.2kva Complete Inverter System.

spinola:
A small price to pay! mercurydirect.com.ng



Re: Inverter Users : Lets Have Your Experience by coderXO(m): 8:36am On Nov 18, 2015
teeowl:
Spinola, I have gone to that website. My questions are:
1.) How many hours does it take to charge Mercury 1.2kva Complete Inverter System using a 2.5kva generator - FULL CHARGE
2.) How long can 3 ceiling fans last after full charge on Mercury 1.2kva Complete Inverter System.


I doubt your batteries were fully charged.

You said it charged for 7hrs.

Your inverter battery charger will not have more than a 10a charger at best (this is an estimation), it might be even 5A.

So...charged it for 7hrs x 10a = 70A, this is not a full charge.

1 Like

Re: Inverter Users : Lets Have Your Experience by coderXO(m): 8:37am On Nov 18, 2015
teeowl:
Spinola, I have gone to that website. My questions are:
1.) How many hours does it take to charge Mercury 1.2kva Complete Inverter System using a 2.5kva generator - FULL CHARGE
2.) How long can 3 ceiling fans last after full charge on Mercury 1.2kva Complete Inverter System.


I doubt your batteries were fully charged.

You said it charged for 7hrs.

Your inverter battery charger will not have more than a 10a charger at best (this is an estimation), it might be even 5A.

So...charged it for 7hrs x 10a = 70Ah, this is not a full charge if the batteries were dead or near dead
Re: Inverter Users : Lets Have Your Experience by KOLAPO3(m): 10:15am On Nov 18, 2015
teeowl:
how many KVA is your generator?


My generator is 6.5kva
Re: Inverter Users : Lets Have Your Experience by adanny01(m): 6:41pm On Nov 18, 2015
coderXO:


I doubt your batteries were fully charged.

You said it charged for 7hrs.

Your inverter battery charger will not have more than a 10a charger at best (this is an estimation), it might be even 5A.

So...charged it for 7hrs x 10a = 70Ah, this is not a full charge if the batteries were dead or near dead

I have a mercury 1.2kva inverter that is rated 20a. It charges my 200ah battery in about 8hrs.
Re: Inverter Users : Lets Have Your Experience by coderXO(m): 3:21am On Nov 19, 2015
adanny01:


I have a mercury 1.2kva inverter that is rated 20a. It charges my 200ah battery in about 8hrs.


ok...great. then maybe i was wrong. how do you like the inverter? which model is it?
Re: Inverter Users : Lets Have Your Experience by adanny01(m): 9:49am On Nov 19, 2015
coderXO:


ok...great. then maybe i was wrong. how do you like the inverter? which model is it?

The one with the display.
Re: Inverter Users : Lets Have Your Experience by kiekie1(m): 12:26am On Nov 20, 2015
kiekie1:


Good morning all, Trojan J185p is almost out of stock... Thanks and remain blessed !

Hoppecke still in stock !
Re: Inverter Users : Lets Have Your Experience by Nobody: 11:42am On Nov 22, 2015
Hello Mr. Adanny01, i have been following your review on 1.2kva mercury inverter, i am thinking of buying this inverter just to power 3 standing fans at night - does your standing fan make noise when it is on your modified sine wave inverter - 1.2kva mercury inverter?

i am asking because i just need an affordable modified sine wave inverter to power 3 standing fans so that everybody in my house can sleep soundly at night and i heard fans on modified sine wave inverters make too much noise.

adanny01:


I love that inverter even though i have never used it. It seems well built as per quality and data sheet. I am particularly thrilled with the inbuilt AVR, power factor, wall mount ability, display etc.

The downside is that since a switch between UPS or Inverter mode isnt mention coupled with the fact that the data sheet only mentioned 150-280v operating range, i am scared. In my area, we do have low voltage supply on grid so it will be bad if the above is only applicable. Right now my inverter with inverter mode range of 90-280v is struggling to charge since saturday night when our supply voltage dropped below 90v.

Power factor is 9.5-1 avcording to the datat sheet so 0.9 can be assumed very save. It means you can power your inverter to 1.35kilowatts. I wouldnt go beyond 1000watts. Besides, i will lose hours of backup with more load. If ever you need to run fridge, start generator.

With 75A charger, thats very suitable for very fast charging of 2 batteries. 75A can even do 3 batteries well.
Re: Inverter Users : Lets Have Your Experience by Nobody: 11:45am On Nov 22, 2015
Mr. KOLAPO3, does your ceiling fan make noise when it is on mercury 2.4 modified sine wave inverter?

what brand of ceiling fans are you using?

KOLAPO3:


I am also having some challenges with my mercury 2.4 inverter and 2 genus batteries 200ah. I purchased the system 3months ago
Since phcn has been better over the last 3 months in my area I have enjoyed the set up.
But now things are back to a bad state.i have a lot of questions. It takes almost 24hrs to get the batteries charge to full.
Eg 7 hours of charge (5hrs generator 2 Nepa)
Only lasted for 3hrs with just 2 ceiling of fans
I am really confused
Please help
Re: Inverter Users : Lets Have Your Experience by adanny01(m): 11:51am On Nov 22, 2015
teeowl:
Hello Mr. Adanny01, i have been following your review on 1.2kva mercury inverter, i am thinking of buying this inverter just to power 3 standing fans at night - does your standing fan make noise when it is on your modified sine wave inverter - 1.2kva mercury inverter?

i am asking because i just need an affordable modified sine wave inverter to power 3 standing fans so that everybody in my house can sleep soundly at night and i heard fans on modified sine wave inverters make too much noise.


For my standing fan, the noise difference is not significant as i can barely hear it when its on inverter but the ceiling fans is more significant. It wont stop most people from sleeping soundly though.

1 Like

Re: Inverter Users : Lets Have Your Experience by Nobody: 12:29pm On Nov 22, 2015
thanks man... i would use standing fan since the noise level is lesser...

adanny01:


For my standing fan, the noise difference is not significant as i can barely hear it when its on inverter but the ceiling fans is more significant. It wont stop most people from sleeping soundly though.

1 Like

Re: Inverter Users : Lets Have Your Experience by Nobody: 5:58pm On Nov 22, 2015
Just one quick question Mr. Adanny... do you use your modified sine wave inverter for your laptop and flat screen TV also?... these are expensive devices, i don't want to risk damage on them.

adanny01:


For my standing fan, the noise difference is not significant as i can barely hear it when its on inverter but the ceiling fans is more significant. It wont stop most people from sleeping soundly though.
Re: Inverter Users : Lets Have Your Experience by abunafiu(m): 4:17pm On Nov 23, 2015
I would like to throw this issue up for discussion. I installed a number of 1.5kva 24v inverters(safepower, luminous, genius , sukham etc). After 10 months thereabout, the clients notified me of reduced number of hours of backup. Preliminary checkes revealed a failing battery and in most cases, the most negative battery. The same happens with INDIAN 48v inverters too. Lets discuss the possible causes and solution. My integrity has been badly affected as a result because I promised most of them 2yrs of useful battery life. The most annoying part is most clients are my senior colleagues at work...u all know what it means.

1 Like

Re: Inverter Users : Lets Have Your Experience by pointstores(m): 8:37pm On Nov 23, 2015
for DOES THAT HAVE PROBLEM WITH SLOW CHARGEING WE HAVE THE SOLUTION WE HAVE 20AH,50AH,60AH, EXTERNAL CHARGER ERISSON AND EMERSON IN STOCK AVAILABLE IN 24VOLT 48VOLT 96VOLT WHAT WE DO WE BUILD AND REPAIR INVERTER ,SOLAR PANEL AND AUTOMATIC CHANGE OVER WE SPECAL ON PURE SINE WAVE,SINE WAVE,SQUARE WAVE AND MODIFIED SINE WAVE VISIT REPAIRELECTRONICS.COM.NG FOR MORE INFO OR CALL 08166117634
Re: Inverter Users : Lets Have Your Experience by adanny01(m): 10:42pm On Nov 23, 2015
teeowl:
Just one quick question Mr. Adanny... do you use your modified sine wave inverter for your laptop and flat screen TV also?... these are expensive devices, i don't want to risk damage on them.


Yes, i do.

My 32" LED tv + Dstv + home theatre are almost always powered on except when sleeping.

Others are standing fan, laptop, phone chargers, 8 18w economy bulbs, 3 ceiling fans and a blender all when required. I usually turn off most lights especially the 2 outside when power fails. My kids bedroom is lighted and the standing fan in my room is powered all night.
Re: Inverter Users : Lets Have Your Experience by coderXO(m): 7:12am On Nov 24, 2015
pointstores:
for DOES THAT HAVE PROBLEM WITH SLOW CHARGEING WE HAVE THE SOLUTION WE HAVE 20AH,50AH,60AH, EXTERNAL CHARGER ERISSON AND EMERSON IN STOCK AVAILABLE IN 24VOLT 48VOLT 96VOLT WHAT WE DO WE BUILD AND REPAIR INVERTER ,SOLAR PANEL AND AUTOMATIC CHANGE OVER WE SPECAL ON PURE SINE WAVE,SINE WAVE,SQUARE WAVE AND MODIFIED SINE WAVE VISIT REPAIRELECTRONICS.COM.NG FOR MORE INFO OR CALL 08166117634

People want to see products and prices on "product" websites.
Re: Inverter Users : Lets Have Your Experience by pointstores(m): 7:33am On Nov 24, 2015
is a service website not ecommerce website
Re: Inverter Users : Lets Have Your Experience by Nobody: 9:40am On Nov 24, 2015
all these using 2 batteries on a 1.2kva modified sinewave inverter? it is more impressive than i thought, i was only thinking of using it for fan at night.

adanny01:


Yes, i do.

My 32" LED tv + Dstv + home theatre are almost always powered on except when sleeping.

Others are standing fan, laptop, phone chargers, 8 18w economy bulbs, 3 ceiling fans and a blender all when required. I usually turn off most lights especially the 2 outside when power fails. My kids bedroom is lighted and the standing fan in my room is powered all night.
Re: Inverter Users : Lets Have Your Experience by coderXO(m): 10:04am On Nov 24, 2015
teeowl:
all these using 2 batteries on a 1.2kva modified sinewave inverter? it is more impressive than i thought, i was only thinking of using it for fan at night.


2 batteries because it is 24v
Re: Inverter Users : Lets Have Your Experience by Nobody: 10:15am On Nov 24, 2015
Okay you are using two 12V 200AH Batteries?


coderXO:


2 batteries because it is 24v
Re: Inverter Users : Lets Have Your Experience by coderXO(m): 10:51am On Nov 24, 2015
teeowl:
Okay you are using two 12V 200AH Batteries?



not me, those who are using two batteries on a 1.2kva system are likely using it because they need to make up 24v.

if it is a 12v system, then they are using it to add more back up time.
Re: Inverter Users : Lets Have Your Experience by kiekie1(m): 10:21pm On Nov 24, 2015
HURRY ! HURRY !! DISCOUNT SALES !!!!!!

USA TROJAN L16-RE Premium Line Flooded Lead Acid Battery 6V (410AH)20hr Rate ..... @ 75k

USA TROJAN J185P-AC Signature Line Flooded Lead-Acid Battery 12V (205AH) 20hr Rate .... "NOW IN STOCK"....@65k

Solarworld mono panels 255w ,260w,265w "made in Germany" etc now in stock at very discounted prices.........

JOY SOLAR MODULES

POLY SOLAR PANEL:
80W N10000. 100W N13500. 120W N16000. 130W N16500. 160W N23000. 170W N25000. 180W N26000. 250W N30000. 280W N40000.

MONO SOLAR PANEL:
80W N12000. 100W N15000. 110W N15500. 120W N18000. 130W 20000.180W N28000.

Latest model 10kva wall mount servo stab (AC input range 80V-270V)....... @50k

Must power star light inverters with charge current adjustable variable,LCD display,wall mount,remote port,load wattage display,flooded/gel/agm battery settings,battery equalisation and desulphation settings...
1kw 12v =50k
1.5kw 12v =60k
2kw 12v =75k
2kw 24v =75k
3kw"4kva" 24v =120k
4kw 24v/48v =140k
5kw 24v/48v =160k
6kw"7.5kva"24/48v=210k
8kw 192v. =350k
10kw 96v. =380k

Must power inverter boards ...@25k

Programmable timer switch with LCD display 220vac 16a........ @4k

The EP Solar "I TRACER" 60a mppt controller is simply rugged compared to Morningstar price and has excellent features like: -inbuilt LCD display,
-high efficiency energy harvest with advanced mppt algorithm
-dual core (ARM CPU+DSP) control architecture
-run data and event recording
-multi phase synchronous rectification tech realizing peak conversion efficiency 98%
-high reliabilty including reverse connection, over current and load short protection etc
-diversified load control mode
-monitor software supplement and firmware update
-extensive communication capabilities (RS232, RS485 with modbus protocol, CAN bus extendable)....@


*AUTHORIZED DEALER SOLAR SHOP LTD PRODUCTS*
All our products come with 1 year Warranty

For best affordable prices,contact Smartcell Global Services,Lagos Nigeria. Simply call Sir Frankie "+2348135031951" for purchase,fast delivery and waybills .. Thanks !!!
Re: Inverter Users : Lets Have Your Experience by kiekie1(m): 10:23pm On Nov 24, 2015
kiekie1:
HURRY ! HURRY !! DISCOUNT SALES !!!!!!

USA TROJAN L16-RE Premium Line Flooded Lead Acid Battery 6V (410AH)20hr Rate ..... @ 75k

USA TROJAN J185P-AC Signature Line Flooded Lead-Acid Battery 12V (205AH) 20hr Rate .... "NOW IN STOCK"....@65k

Solarworld mono panels 255w ,260w,265w "made in Germany" etc now in stock at very discounted prices.........

JOY SOLAR MODULES

POLY SOLAR PANEL:
80W N10000. 100W N13500. 120W N16000. 130W N16500. 160W N23000. 170W N25000. 180W N26000. 250W N30000. 280W N40000.

MONO SOLAR PANEL:
80W N12000. 100W N15000. 110W N15500. 120W N18000. 130W 20000.180W N28000.

Latest model 10kva wall mount servo stab (AC input range 80V-270V)....... @50k

Must power star light inverters with charge current adjustable variable,LCD display,wall mount,remote port,load wattage display,flooded/gel/agm battery settings,battery equalisation and desulphation settings...
1kw 12v =50k
1.5kw 12v =60k
2kw 12v =75k
2kw 24v =75k
3kw"4kva" 24v =120k
4kw 24v/48v =140k
5kw 24v/48v =160k
6kw"7.5kva"24/48v=210k
8kw 192v. =350k
10kw 96v. =380k

Must power inverter boards ...@25k

Programmable timer switch with LCD display 220vac 16a........ @4k

The EP Solar "I TRACER" 60a mppt controller is simply rugged compared to Morningstar price and has excellent features like: -inbuilt LCD display,
-high efficiency energy harvest with advanced mppt algorithm
-dual core (ARM CPU+DSP) control architecture
-run data and event recording
-multi phase synchronous rectification tech realizing peak conversion efficiency 98%
-high reliabilty including reverse connection, over current and load short protection etc
-diversified load control mode
-monitor software supplement and firmware update
-extensive communication capabilities (RS232, RS485 with modbus protocol, CAN bus extendable)....@


*AUTHORIZED DEALER SOLAR SHOP LTD PRODUCTS*
All our products come with 1 year Warranty

For best affordable prices,contact Smartcell Global Services,Lagos Nigeria. Simply call Sir Frankie "+2348135031951" for purchase,fast delivery and waybills .. Thanks !!!

Mercury Tubular / Flooded deep cycle batteries 12v 220a .Bonanza sales .(1 year & half warranty) ....... 55k only
Re: Inverter Users : Lets Have Your Experience by adanny01(m): 6:52am On Nov 25, 2015
teeowl:
all these using 2 batteries on a 1.2kva modified sinewave inverter? it is more impressive than i thought, i was only thinking of using it for fan at night.


Point of correction. I have only 1 12v 200ah battery with 1.2kva 20a modified sinewave inverter. The battery wasn't even bought new.

I get well over 12hrs of back up when i manage the power consumption well.

My family knows the connection well and everyone goes into power saving mode once mains is off. All power sockets in the house is directly mains so we know when the lights on the sockets of inverter or fridge goes off. The drill i taught them is to turn off all lights and fan not being used immediately mains go off.

1 Like

Re: Inverter Users : Lets Have Your Experience by adanny01(m): 7:04am On Nov 25, 2015
coderXO:


not me, those who are using two batteries on a 1.2kva system are likely using it because they need to make up 24v.

if it is a 12v system, then they are using it to add more back up time.

I think they were refering to me but i use one battery.

Infact the battery i use was given to me by a friend who bought 2 of them but later purchased a 900va 12v inverter with 20a charger. We realised he couldnt charge both batteries well with 20a so he disconnected one and let me have it.

Its either he gets a 40a charger or manage one.

When next am buying an inverter, now i know that its charger is as important as the battery bank.

I have realised too that it is better to have a 48v system running on 4 12v batteries than a 24v on the same battery bank even if the charging capacity is same.

3 Likes

(1) (2) (3) ... (35) (36) (37) (38) (39) (40) (41) ... (168) (Reply)

How To Hack Any Wifi Network Password Using Cmd / Huawei USB Modem Unlocker - Download Here! / Post Your Computer (PC) Troubles Here.

Viewing this topic: 1 guest(s)

(Go Up)

Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health
religion celebs tv-movies music-radio literature webmasters programming techmarket

Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)

Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 72
Disclaimer: Every Nairaland member is solely responsible for anything that he/she posts or uploads on Nairaland.