Re: Solar Energy, A Complement To FTA by Wazari: 10:07am On Jul 22, 2018 |
People get misled all the time. If you have correctly calculated that a cable needs a certain size of breaker to protect it, please do not just use the next higher size that is readily available. The MCB will only function as a switch and offers a false sense of safety. If you cannot find the correct breaker, upsize the cables. If you decide to use the higher rated MCB for the same cable, you need to understand that it is a risk and maybe it will make you more vigilant (constantly looking out for any signs of a fire). To prevent a fire, you should use an MCB with a lower amp rating than the cable not higher. 6 Likes |
Re: Solar Energy, A Complement To FTA by NextDayPP: 10:59am On Jul 22, 2018 |
Ogas Wazari and S007, please let this rest, even those of us that started yesterday know that cables don't have to get to 'firing' point before breakers come to action. Thank you both for your explanations. #Firing��� Wazari: 2 Likes |
Re: Solar Energy, A Complement To FTA by primefaith1: 11:04am On Jul 22, 2018 |
Flames Solar Panels : 150w mono ...... ₦ 23,000. 200w mono........ ₦33,000. 250w mono..........₦40,000. 300w mono.........₦47,000. Call/whatsapp: 08084858853. |
Re: Solar Energy, A Complement To FTA by richmon74(m): 11:20am On Jul 22, 2018 |
makavele: I have a lot of things I would want to comment on this installation but for some reasons I might not be able to. One of such reasons is the fact that I enjoy reading comments from others. Some very honestly 'wrong' corrections and some I have to learn from though. Over time I have seen some people who use to ask basic questions here become pro advisers. It means this thread has built a lot of people. There's one thing that I want to mention (maybe someone else has already mentioned because I am yet to read through the whole comment but there's nothing wrong in repeating). It is about the busbars. Please always endeavour to use a 100% STAINLESS STEEL bolt anytime you have to deal with electrical contacts especially in the DC circuits. You might be loosing current with the bolt/nuts you are using at the moment and over time it will get worse. Worse than loosing current is the risk of fire that might emanate from the heat from the iron with the wood beneath it. We have had to correct this error in most of the installations we are contracted to correct. We have even seen situations where those ordinary steel bolts for battery terminals which will heat up sending electrons away in the heat. When you are using wood to mount electrical circuits care should be taken to ensure that the conductive surfaces doesn't come in contact with the wood especially surfaces that are prone to heat. In your own case here, The iron bolt you are using (wrongly) is directly on the wood. One simple way to know if the bolt is stainless steel is to use a magnet to test. There shouldn't be any iron in it. Just the level of my knowledge. I am always open for correction. 7 Likes 1 Share |
Re: Solar Energy, A Complement To FTA by pranil(m): 11:44am On Jul 22, 2018 |
makavele: The wires to the CC breaker and CC are at an odd angle. The wires should come out at least 1 -2 inch and then bent in a hook shape not immediately after existing the MCB |
Re: Solar Energy, A Complement To FTA by pranil(m): 11:54am On Jul 22, 2018 |
kiekie1: since we are on DC breaker please ensure polarity is correct.( unless the breaker is non polarized) the attached document is very clear for the D.i>Y installer. https://drive.google.com/file/d/1W44FlBLvVdz6lTJ0nfHZLzFLVQlIguox/view?usp=sharing |
Re: Solar Energy, A Complement To FTA by pranil(m): 12:16pm On Jul 22, 2018 |
S007: The DC breakers have two different tripping points ( magnetic - for short circuit ) and Thermal for overload - Without complicating things the breaker can have different curves ( B,C,D ) for the same rated current and the correct one should be chosen to avoid nuisance tripping . The rated current marked on breaker is In ( nominal) which it can continuously carry For those interested can go through the attached document but short summary is in the picture . https://drive.google.com/file/d/0B6eOIBrQmTfLYXJfaTZhejRSbnc/view?usp=sharing When it comes to electrical safety I would rather be more cautious than going for a higher value because it just might trip The best protection in DC circuits is not the 440 AC fusebox normally seen in Nigeria but[b] CLASS T fuse followed by Circuit breaker[/b] which ensures minimal let through energy by it's fast action - https://www.amazon.com/Blue-Sea-Systems-5502-225-400/dp/B076GTZ6PY https://www.aliexpress.com/item/Free-shipping-5pcs-A3T250-CLASS-T-Ferraz-Shawmut-French-Roland-fuse-250A300V-brand-new/32839022494.html https://www.aliexpress.com/snapshot/0.html?spm=a2g0s.9042647.6.2.2e2e4c4dU1TYtt&orderId=502844851612310&productId=32812689338 https://zerohomebills.com/product/enwitec-battery-safety-breaker-slim-250-75v-250a/ 1 Like
|
Re: Solar Energy, A Complement To FTA by Wazari: 12:17pm On Jul 22, 2018 |
NextDayPP: Chief NextDayPP, if you know all about cables, breakers and "firings", then you do not need to pay attention to my explanations. I have seen far too much false information being bandied around in Nigeria causing system failures and accidents. I know there are many people who have a bad opinion of solar because someone they know invested in solar and lost a lot of money. It is definitely in our interest in this forum to correct misinformation as much as possible and in a civilized manner. 4 Likes |
Re: Solar Energy, A Complement To FTA by pranil(m): 12:34pm On Jul 22, 2018 |
Wazari: When it comes to electrical installation safety better be safe than sorry. Just because somebody has not seen a fire yet does not mean it did not happen. All the standards and regulations are designed for that 1 % probability when something can go wrong and ensure safety. maybe we do not see many incidences in Nigeria due to low penetration and lower capacities Normally the risk is minimized, as switches are designed to fail safely. to become a fire hazard, there would need to be ignition while being switched off under load and the switch housing or cable would have to fail. Also Flammable material would also need to be close by.( wood !!) 1 Like |
Re: Solar Energy, A Complement To FTA by Wazari: 12:43pm On Jul 22, 2018 |
pranil: Exactly my point. Although in many cases, the flammable material might only be the cable insulation. |
Re: Solar Energy, A Complement To FTA by makavele: 1:16pm On Jul 22, 2018 |
pranil: Strain relief, okay I get that . Thanks |
Re: Solar Energy, A Complement To FTA by makavele: 1:18pm On Jul 22, 2018 |
pranil: We are all humans and prone to mistakes but I think polarity issues is one mistake I cannot make because I quaudruple check before giving it the breathe of life. Although I have a couple of non polarized mcbs, sitting somewhere, if my memory serves me right 1 Like |
Re: Solar Energy, A Complement To FTA by S007: 1:35pm On Jul 22, 2018 |
@ Waziri and @Pranil. Thanks so much for your comments. God bless you. @kiekie I have no intention to disparage anybody. My aim is never to win an argument here. All I desire is just to pass the right information across. Sometimes I think it is a duty. I have friends who have been seriously injured, properties burnt and millions lost before. Part of the root cause is information gaps. I think we all have a moral obligation to always seek the truth. One holy book says the truth will make us free. I think I am done with this CB topic. 1 Like |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 2:28pm On Jul 22, 2018 |
pranil: Yes Boss .. We always observe polarity whilst installing ! Thanks for your contribution as usual Sir ! |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 2:29pm On Jul 22, 2018 |
richmon74: Good point Sir ! I sure know of two modes which we have here...; >>New feature "Likers association of Nairaland" LAN >>"Discreet observers association of Nairaland" DOAN 1 Like |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 2:31pm On Jul 22, 2018 |
pranil: Thanks for the summary.. Quite vivid & lucid ! |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 2:42pm On Jul 22, 2018 |
S007: Lol case has ended to me since ... I just type briefly & move back to "observation mode" as an old school forumite ! I knowingly pop out to type outside adverts sometimes ..Let's just keep praying we don't experience fire outbreaks by Gods grace as most inverters or pv installations i have seen don't even have saftety breakers , more also the simple phcn cutouts don't even specify the appropriate mm² looping strand to be used when bought at electrical stores , so what more can we say .. One love ! Gracias 2 Likes
|
Re: Solar Energy, A Complement To FTA by Oshomo12(m): 3:02pm On Jul 22, 2018 |
kiekie1: I love the way the issue (CB) started and ended (especially with ur summary/finishing up there). Seriously, how this country is still standing without any known code or standard baffled me. Over the few years I ve stay alive( just a little above 10yrs), I ve seen quite a number of accidents as a result of electrical mismatch. They burn as if petrol was used on them! 1 Like |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 3:12pm On Jul 22, 2018 |
Oshomo12: Lovely point.. I am marvelled! SON lacks integrity in ensuring standards .. We can rarely differentiate original items from fakes this days in almost all goods in the open market ! Average phcn staff takes bribe and goes his way, same with Lagos state building control agency takes bribe and so on"Ambode sacked GM & 3 others some years ago" but same keeps happening #decayed-spoilt-system ! God help us all !! 1 Like |
Re: Solar Energy, A Complement To FTA by BRIGHTSOLAR(m): 3:20pm On Jul 22, 2018 |
DROP SHIPPING AND ONLINE DELIVERY OF RENEWABLE ENERGY MATERIALS INVERTER MICROTECH INVERTER 900VA,12V N46,000 1.1KVA,12V N53,000 1.6KVA/24V N72,000 2KVA/24V N80,000 2.6KVA/36V N105,000 3.6KVA/48V N170,000 5.2KVA/48V N340,000. 5.5KVA/96V N340,000 10KVA/180V N790,000 PRAG INVERTER 1.1KVA,12V N70,000 1.2KVA,12V N90,000 1.5KVA/24V N110,000 2.5KVA/24V N125,000 4KVA/24V N270,000. 7.5KVA/120V N500,000 MUST POWER STAR INVERTER 4kva 3000W 24V N 220,000 4kva 3000W 48V N 260,000 5kva 4000W 48V N 350,000 6kva 5000W 48V N 400,000 7.5kva 6000W 48V N 450,000 10kva/48V 8000W 48V N 950,000 HYBRID INVERTER VOLTRON SERIES 1.4KVA/12(30A N65,000 2.4KVA/24V50A N97,000 3KVA /48V 60A MPPT N220,000 5KVA /48V 60A MPPT N310,000 7.5KVA /48V 60A MPPT N430,000 10KVA /48V 100A MPPT N750,000 15KVA /48V 60A MPPT N850,000 15KVA /48V 120A MPPT N890,000 GENEXTECH SERIES 2KVA/24V(600W MPPT) #138,000 3KVA/24V(600W MPPT) #149,000 3KVA/24V(1500W MPPT) #194,000 3KVA/48V(3000W MPPT) #202,000 5KVA/48V(3000W MPPT) #306,000 10KW/48V(14850W MPPT) #1,660,000 STABILIZER VOLTRON STABLIZER 6KVA WALL MOUNT RELAY REGULATOR #45,000 6KVA WALL MOUNT SERVO REGULATOR #65,000 12KVA WALL MOUNT RELAY REGULATOR #90,000 12KVA WALL MOUNT SERVO REGULATOR #120,000 PRAG STABLIZER 10KVA WALL MOUNT SERVO REGULATOR #130,000 12KVA WALL MOUNT RELAY REGULATOR #120,000 15KVA WALL MOUNT RELAY REGULATOR #140,000 15KVA WALL MOUNT SERVO REGULATOR #240,000 20KVA RELAY REGULATOR #195,000 20KVA SERVO REGULATOR #370,000 30KVA SERVO REGULATOR #470,000 BATTERY GENEX BATTERY 12V/200AH N 120,000 LONG BATTERY 12V/200AH N 120,000 MONBAT BATTERY 12V/200AH N 125,000 MONBAT BATTERY 12V/210AH N 120,000 ELSON BATTERY 12V/200AH N 115,000 MICROTEC BATTERY 12V/200AH N 105,000 M POWER BATTERY 12V/200AH N 105,000 EASTMAN 12V/200AH TALL TUBULAR BATTERY N115,000 GLT BATTERY 12V/200AH N 90,000 ZEEDIX BATTERY 12V/200AH N 95,000 RITAR BATTERY 12V/200AH N 130,000 PRAG BATTERY 12V/200AH N 140,000 PATTERN BATTERY 12V/200AH N100,000 QUANTA BATTERY 12V/200AH N 130,000 BATTERY RACK BATTERY RACK 2 BATTERY N 15,000 BATTERY RACK 4 BATTERIES N 30,000 BATTERY RACK 8 BATTERIES N 50,000 CHARGE CONTROLLER ROY SOLAR SERIES 20A 12/24V PWM CONTROLLER N 20,000 30A 12/24V PWM CONTROLLER N 25,000 40A 48v PWM controller (LED) N 50,000 30A 96v PWM controller (LCD) N 120,000 60A 48v PWM controller (LCD) N 95,000 COWIN SERIES 20A 12/24V PWM CONTROLLER N 15,000 30A 12/24V PWM CONTROLLER N 20,000 40A 12/24V PWM CONTROLLER N 25,000 50A 12/24V PWM CONTROLLER N 32,000 60A 12/24V PWM CONTROLLER N 41,000 40A 48v PWM controller (LED) N 25,000 50A 48v PWM controller (LED) N 32,000 60A 48v PWM controller (LED) N 50,000 COWIN MPPT SERIES 40A 12/24/48v MPPT controller (LCD) N 80,000 60A 12/24/48V MPPT controller (LCD) N 130,000 EPEVER MPPT SERIES 12/24/48 /45A N 145,000 12/24/48 /60A N165,000 FANGUNPSUN MPPT SERIES 30A 24V N40,000 60A 48v N140,000 80A 48v N170,000 SOLAR PANELS JOY SOLAR PANEL 150w MONO -N32,000 200w MONO -N33,000 260w MONO -N54,000 150w POLY –N27,000 200w POLY -N31,000 260w POLY -N52,000 TRINA SOLAR PANEL 300w MONO -N85,000 320w MONO -N110,000 YINGLIN SOLAR PANEL 100w POLY -N22,000 150w POLY -N33,000 200w POLY -N39,000 260w POLY -N51,000 310w POLY -N62,000 100w MONO-N25,000 150w MONO -N33,000 200w MONO -N39,000 260w MONO -N59,000 320w MONO -N74,000 CANADIAN SOLAR PANEL MONO- 290w. N60,000 (BULK PURCHASE ONLY) 330w. N66,000 (BULK PURCHASE ONLY) POLY 270w. N45,000 (BULK PURCHASE ONLY) 275w. N59,000 (BULK PURCHASE ONLY) ACCESSORIES PROGRAMMABLE Digital timer 15A N7,000 PROGRAMMABLE Digital timer 25A N9,000 BATTERY BALANCER /EQUALIZER 48V 35,000 BATTERY BALANCER EQUALIZER 24V #30,000 BATTERY VOLTMETER INDICATOR #1,700 DC CIRCUIT BREAKER 63A/120V---500V 2 POLE N 8,000 DC CIRCUIT BREAKER 125A/500V 2 POLE N 14,000 DC TV 17INCHES DC TV #31,000 24INCHES DC TV #40,000 28INCHES DC TV #48,000 32INCHES DC TV #65,000 DC IRON 150WATTS #9,000 DC IRON 300WATTS #15,000 COMPLETE SOLAR SOLUTION Call-07058562938 Bright Solar Power WHATSSAP 08187995847 FOR PURCHASE/ DELIVERY INSTALLATION NATIONWIDE https:///send?phone=2348187995847 |
Re: Solar Energy, A Complement To FTA by mcTrinity(m): 3:25pm On Jul 22, 2018 |
wow... A lot have been said about the CB. nevertheless, I have a small observation with a small question... It has been stated that most of these DC breakers are polarized and the polarity must be strictly adhered to. I've observed that sometimes a 2-pole DC breaker is used to break only the positive cable. What is been done is that the strand of the positive cable will be divided between the two poles of the 2-ploe breaker. I've seen it on a Sukam/Mopower 5kva/48v Inverter. A 2-pole breaker was used for the Battery disconnect for only the positive cable. what I can't remember was whether the breaker was actually polarized. so, is a right practice. as a matter of fact, I just installed the breaker in the attached pic where I did something like that. used it for INVERTER-BATTERY disconnect and also for the SCC-BATTERY disconnect on only the +ve cables with the strands divided... "You're dead the day you stop learning"
|
Re: Solar Energy, A Complement To FTA by mank1234(m): 4:34pm On Jul 22, 2018 |
pranil:In lay man's parlance, 1) highest voltage expected must be less than Vn on breaker. 2) (a) current rating of conductor must be higher than rating of breaker to protect wire(b) rating of breaker must be at least 1.25 of expected current to avoid nuisance tripping 3) short circuit rating of breaker must be greater than possible short circuit in the connection else the breaker will fail to trip in some short circuit situation. If you see an unsafe act, stop it. If you can't stop it, report it. |
Re: Solar Energy, A Complement To FTA by mank1234(m): 5:02pm On Jul 22, 2018 |
@makavele: your setup is neat and lovely. consider using a contactor for automatic changeover instead of 2 separate switches which can both be turned on accidentally |
Re: Solar Energy, A Complement To FTA by makavele: 5:08pm On Jul 22, 2018 |
mank1234: thanks but i dont understand what u mean by 2 seperate switches which can both be turned on accidentally. there is only 1 dedicated switch for generator or mains input which is drawn from the main db and one for output; thus they can both be and should be left on then the fancy white privacy box for changeover between inverter, mains/generator and total darkness(neutral) so please elucidate |
Re: Solar Energy, A Complement To FTA by makavele: 5:12pm On Jul 22, 2018 |
mank1234: without resorting to speaking too much English, well said !!! |
Re: Solar Energy, A Complement To FTA by mank1234(m): 5:15pm On Jul 22, 2018 |
makavele: I thought both were for input from different power source. Congrats once again. |
Re: Solar Energy, A Complement To FTA by makavele: 5:18pm On Jul 22, 2018 |
mank1234: Oh okay, i am trying to design labels and warning stickers which would be placed appropriately for identification and clarification of what does what etc thanks once again 1 Like |
Re: Solar Energy, A Complement To FTA by bigrovar(m): 5:26pm On Jul 22, 2018 |
@pranil On the axpert inverters particularly the ipowerplus model. I finally figured out a way to log the inverter output/inputs without buying the $60 AICC software. It basically hs to do with probing the /dev/hidraw0 interface directly and formatting the output to json and uploading it to emoncms. The problem I am now having is the current shunt measurement seem to limited to power load above 100w. anything below 100w is recorded as 0 watt output and 0 system load. I see this even on the inverter display.. I need to be pulling about 120w before the inverter registers the output. This is a problem for me because my night load is often times below 80w (especially when the house goes to bed) and during that period inverter records 0 output.. defeating the whole essence of logging in the first place. Do you experience this same issue with AICC? I am using the 3kva 24v model |
Re: Solar Energy, A Complement To FTA by pranil(m): 6:28pm On Jul 22, 2018 |
mcTrinity: The other pole should break negative and not positive of the array if you want to save money/space . basically Higher voltage + should be on positive and ve should be on negative for Battery to inverter + of the battery to + of the breaker for PV array + ve of solar to +ve of the breaker
|
Re: Solar Energy, A Complement To FTA by bigrovar(m): 6:36pm On Jul 22, 2018 |
Decided its time to let go of this my trusted inverter. It was sent to be bench because I decided to go the transformerless inverter route and got the ipower plus. I decided to keep the latter mostly because of its communication capabilities. This inverter has been in the box for a while but I have to kill sentiment and let it go. You can read up on my review of the inverter here http://bobby.com.ng/2017/06/28/felicity-inverter-a-short-review/ Price is 95k Specs 3.5kva 24v Max charge amp 35A Selectable charge profile (for volts and amps) Ability to disable charging. |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 11:23pm On Jul 22, 2018 |
Oga BigRovar Please how do you disable charging on this unit? I know one can set the charge amps to very low - as low as 5-10amps but I never knew you could disable it entirely? Could it be setting number '0' on the voltage profile selection? bigrovar: |
Re: Solar Energy, A Complement To FTA by bigrovar(m): 4:58am On Jul 23, 2018 |
NiyiOmoIyunade: 2 ways of disabling charging on the unit. Via the Battery type selector choose "not used" you can also do it via the charging current settings. Choose 0%. Those two options disables charging from the unit completely. (used the Victron battery monitor to verify that indeed charging was disabled when those options are selected) If you are on a pre paid meter and you have sufficient solar pv. It is better to disable inverter charging to better utilise your solar and reduce electricity bills. 1 Like |
(1) (2) (3) ... (436) (437) (438) (439) (440) (441) (442) ... (1821) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: zenith4biz(m) and 2 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 109 |