Welcome, Guest: Register On Nairaland / LOGIN! / Trending / Recent / NewStats: 3,207,876 members, 8,000,689 topics. Date: Tuesday, 12 November 2024 at 01:47 PM |
Nairaland Forum / Entertainment / TV/Movies / Satellite TV Technology / Solar Energy, A Complement To FTA (2382642 Views)
UPS Back-up, Also A Complement To FTA / FTA Frequency / Cctv Installation A Complement To Fta And Solar Energy (2) (3) (4)
(1) (2) (3) ... (491) (492) (493) (494) (495) (496) (497) ... (1853) (Reply) (Go Down)
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 6:30pm On Jan 09, 2019 |
Looks like possible overcharging? What is your absorb voltage set to? How often do you equalize? Do you top a lot of water regularly or just a few MLs a week (like a syringeful per battery cell) olatade: |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 8:35pm On Jan 09, 2019 |
olatade: high charging voltage, i suspect your inverter or charge controller is outputing >15v per battery for charging, if filled properly, it shud stay 2 to 3 months btw top ups |
Re: Solar Energy, A Complement To FTA by DMerciful(m): 9:08pm On Jan 09, 2019 |
Epsolar has honoured their warranty twice for me and fangpusun once for my friend....They are awesome! bigrovar: |
Re: Solar Energy, A Complement To FTA by Trippledots(m): 11:17am On Jan 10, 2019 |
dapsyra: That means it can work as an ats right? If so, link or where to purchase one pls. Thanks |
Re: Solar Energy, A Complement To FTA by Trippledots(m): 11:21am On Jan 10, 2019 |
NiyiOmoIyunade: Pls explain bolded... Thanks |
Re: Solar Energy, A Complement To FTA by NextDayPP: 5:19pm On Jan 10, 2019 |
@Niyi I will be needing a Felicity inverter soon, who do I contact for price pls. Will a 2kva inverter be able to handle (2) 100W deep freezers, keeping in mind the surge at start up. Thank you. |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 5:42pm On Jan 10, 2019 |
Felicity's entry level 24v inverter is a 2.5kva - this should do the job with ease - but you have to size the batteries appropriately for the load. How do you plan to recharge the batteries? PHCN, Gen, Solar or a combo? You can reach us on sales@luminanttechsystems.com for an evaluation and price quotes. Thank you. NextDayPP: |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 8:05pm On Jan 10, 2019 |
Please see diagram below - A1 and A2 are the signals to the coil (live and neutral respectively). [1,R1,R3,3] are the COMMON side while [2,R2,R4,4] are the LOAD side. The question you have asked is about the load side wiring. The ideal relay/contactor is a double throw switch such that although multiple power sources (PHCN and Gen) are setup on the COMMON side, ONLY ONE power source at a time can feed the load side - for this reason one is able to use a terminal block or other arrangement to feed the load with 2 power sources [bond the load side...] knowing that only 1 power source can feed the load at any time. One may also use TWO NO contactors but "mechanically interlocked" for safety. As always, please ensure appropriate breakers/fuses are installed at source and load for safety. In this diagram PHCN has priority! Trippledots: 1 Like
|
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 8:18pm On Jan 10, 2019 |
Yes any suitably rated relay/contactor with at least 1 each of NO and NC contacts such as LC1D25008 can serve as an ATS - please see example diagram below; You may need additional circuitry to switch your Gen OFF/ON after power transfer though. Trippledots: 1 Like
|
Re: Solar Energy, A Complement To FTA by zeestone99(m): 9:34pm On Jan 10, 2019 |
NextDayPP: I ll advice u go for a 3.5kva, u won't have to wori about switching off other loads b4 putting on ur freezers, it even prepares u for futuristic loads.. Secondly do ur ba3 sizing well, if possible add solar panels if phcn is an issue in ur area 4 Likes |
Re: Solar Energy, A Complement To FTA by johnmba: 6:44am On Jan 11, 2019 |
kiekie1: How much is your miniclamp meter |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 10:31am On Jan 11, 2019 |
|
Re: Solar Energy, A Complement To FTA by bode4real(m): 7:18pm On Jan 11, 2019 |
My Oga, It will be safer if additional auxiliary contact is added to d contactor, and the Gen Off is wired to the NO of the aux contact. Wit this the GEn goes off immediately PHCN comes in. Just a blink in the Supply NiyiOmoIyunade: 2 Likes |
Re: Solar Energy, A Complement To FTA by NiyiOmoIyunade(m): 8:47pm On Jan 11, 2019 |
My Oga, Your advice makes perfect sense! I upvoted your post. bode4real: |
Re: Solar Energy, A Complement To FTA by mank1234(m): 11:21pm On Jan 12, 2019 |
My charge controller (Morningstar Tristar ts-mppt-60 )will be up for sales in 3 weeks times as I plan to downgrade or upgrade to MPPSolar. Price N200,000 Also up for grab will be my rugged cyberpower 3.5kva CIP model. Price N150,000 2 " 325W solar panel at N55,000 each Victron battery balancer at N25,000 All in perfect working conditions Interested buyers can signify interest by sending pm. |
Re: Solar Energy, A Complement To FTA by ojeysky(m): 8:19am On Jan 13, 2019 |
mank1234: Where are you getting your MPPSolar and what spec is this? |
Re: Solar Energy, A Complement To FTA by hardywaltz(m): 1:13pm On Jan 13, 2019 |
Please house I need to find out the best option for batteries. Seal maintenance free batteries Or Flooded batteries. It's for a location that is unoccupied for most part of the year so regular topping of battery acid maybe impossible. The recent I'm asking is coz a lot of people say they prefer flooded batteries to smf. Thanks |
Re: Solar Energy, A Complement To FTA by GeorgeD1(m): 3:08pm On Jan 13, 2019 |
hardywaltz, i think you have answered the question yourself. if the location will be unoccupied for the better part of the year, then it's better to install sealed maintenance free batteries. flooded batteries are not advisable except you plan going to top them up on a regular basis or sending someone else to do it for you. there are provisions for auto water fillers in after market purchases but that is a different kettle of fish altogether. 4 Likes |
Re: Solar Energy, A Complement To FTA by bigrovar(m): 3:19pm On Jan 13, 2019 |
hardywaltz: The part in bold answers your question. Sealed Maintenance free are called that for a reason and are best for places what are unoccupied for most part of the year as long as they get sufficiently charged. |
Re: Solar Energy, A Complement To FTA by NoMoreTrolling: 4:00pm On Jan 13, 2019 |
earthrealm: The issue is that batteries in Nigeria in general are terrible, anyways our problems are about solved. |
Re: Solar Energy, A Complement To FTA by NoMoreTrolling: 4:04pm On Jan 13, 2019 |
We just ordered for a couple battleborns Lifepo4 12v 100ah batteries and they are in transit to Nigeria. I must say that I'm very very excited at the thought of having a battery that delivers 100% of it's rated capacity over a long period of time. I will keep the house posted when they arrive and on how they perform and if indeed Lithium is the future. From the way I see it, even at current prices, they may already be more cost effective than their lead acid counterparts, especially the ones from Nigeria. 3 Likes |
Re: Solar Energy, A Complement To FTA by Dam5reey(m): 4:27pm On Jan 13, 2019 |
NoMoreTrolling: Nice, abeg provide Link and purchase process. This one can deliver 100A for 1 hour gud stuff for short term heavy loads |
Re: Solar Energy, A Complement To FTA by mank1234(m): 4:55pm On Jan 13, 2019 |
ojeysky: AliExpress and PIP5048MK |
Re: Solar Energy, A Complement To FTA by mank1234(m): 7:38pm On Jan 13, 2019 |
Available for sale at the following offer price: Morningstar Tristar 60A MPPT charge controller @ N200,000 2 " 325W solar panel at N55,000 each Victron battery balancer at N25,000 Current location: Eket |
Re: Solar Energy, A Complement To FTA by ojeysky(m): 6:23am On Jan 14, 2019 |
mank1234: Am also saving to get the 3024GK but the cheapest shipping I have seen so far is about 100USD. How are you getting around the shipping cost? |
Re: Solar Energy, A Complement To FTA by mank1234(m): 9:01am On Jan 14, 2019 |
ojeysky: Try Lstar4real moniker. |
Re: Solar Energy, A Complement To FTA by ojeysky(m): 9:42am On Jan 14, 2019 |
mank1234: Crisvicmall is actually cheaper, still looking for one that can beat their option. |
Re: Solar Energy, A Complement To FTA by Saipro(m): 1:04pm On Jan 14, 2019 |
GeorgeD1:You're my brother indeed! 1 Like |
Re: Solar Energy, A Complement To FTA by panini(m): 1:30pm On Jan 14, 2019 |
Hello Solar Gurus in the forum, I just got a small solar system of a 300W solar panel, a PWM charge controller, a 1000W inverter and a used 200Ah battery. My laptop charger is 65W and the system lasts 3 hours at night. I would like to know if I plug a fan of same wattage (65W) as the laptop without plugging the laptop, would I have the same number of hours? My thought goes into the induction coil in the fan. I am being careful as I got a fairly used battery and I don't want to put too much strain on it. Please help on this. |
Re: Solar Energy, A Complement To FTA by Saipro(m): 2:17pm On Jan 14, 2019 |
My primary 12V charger died after about 10 years of meritorious service. Not keen on rewinding the transformer nor tampering with the FETs (done that once before and it wasn't quite the same). Any recommendations for something cheap and reliable? Needn't exceed 20A (max 30A). Currently rigged a spare 250W panel with a spare CC to help people maintain batteries kept with me. |
(1) (2) (3) ... (491) (492) (493) (494) (495) (496) (497) ... (1853) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: Hero2t, Deesmo07, mrmachine and 2 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 73 |