Re: Solar Energy, A Complement To FTA by SolnergyPower: 5:58pm On Oct 16, 2019 |
Re: Solar Energy, A Complement To FTA by dragnet: 6:14pm On Oct 16, 2019 |
SolnergyPower: scaffold 1 Like |
Re: Solar Energy, A Complement To FTA by SolnergyPower: 6:14pm On Oct 16, 2019 |
Re: Solar Energy, A Complement To FTA by eleojo23: 6:57pm On Oct 16, 2019 |
dragnet: The scaffold points towards the sky so based on the technicality, he is right! 1 Like |
Re: Solar Energy, A Complement To FTA by SolnergyPower: 7:04pm On Oct 16, 2019 |
Re: Solar Energy, A Complement To FTA by ceaser: 7:34pm On Oct 16, 2019 |
Topmost11: For your first question, yes that is Li-ion, the 18650 (186mm by 50mm dimension) battery. Except if it is used, fake or with a falsely declared may rating, each costs nothing less than 1,500 naira. So I doubt the 4200mah that costs 500 naira each for that offer. Also the highest mah any quality Li-ion like NR Samsung 18650 batteries have is 3000 nah. I have yet to see an 18560 with more than 3000 mah capacity. So that battery you have there, if new, is likely fake. At worst, a used one. But you can test the authenticity of the declared capacity if you have a Li-ion charge-discharge meter or a rough estimate if you have a mini weighing scale to just estimate the weight and compare it with the expected weight for the declared capacity (you can get those reference values online) 1 Like |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 7:43pm On Oct 16, 2019 |
Oshomo12: He said he did 2 panels in series for a 12v setup using a pwm controller and it works fine. Why are you asking him to parallel. |
Re: Solar Energy, A Complement To FTA by ceaser: 7:47pm On Oct 16, 2019 |
BetaTechnicians: Finally someone looked the way of my question. I had decided to go with experimentation the way I got around a couple of hitches that remained unanswered here. At least I will be glad to relay back here the success or otherwise of the experiment. @BetaTech, I still think going with a high ampere rating than the one in the circuit will fall within safety limits. I still intend to go with the experiment when I have the opportuned time, but I still welcome more guidance as yours from others. |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 7:48pm On Oct 16, 2019 |
zeestone99: . omo i yaff give up, mek dem continue with whatever works for them...........................hope newbies, wouldnt go and copy wrong info if you can tune in now. morningstarcorp is doing a webinar and this pwm/mppt issue is being thrashed out. https://applauncher.gotowebinar.com/#join/attendee/en_US/e0-nJLihqkTUgXqxVUs2nqZPgGG02PBQ/e0-nJLihqkTUgXqxVUs2nqZPgGG02PBQhJkvJkRHatTHYcf4XIKjQnecEmZyS6jkATXAg5x-UkqyUnQGVQWqib845unLHOvzhcYVYp2MoXk-o5iRvYq-9pekegpJwxW7Sb-lFfvEFZa9s8GfzyCAID6Vk7mSzyVAxZ_vXcMnnpaHZ0gnLjEPKmb1aeQxzwjR-HItzdtt67HR6zwExtIbSmTsMARyoD_iJJ2D8Nwhz-T3ifZniyb00cfOBcmHjXnnpC_TrEkRtCkUL8HaBB3vLE6TP5HVs0xFvkVuQHSqrpPA2tpxuqYtls37Xoz5xiyJic4PqOz8wAGxgj27k27iQWKXYMoa2C0Jo1Ltv-86VZYoP9kr0sZPe4lmLMiqgvVJBQKxY8ILE05UxSbBThSTPOaq6BiYxS0eXkRF7SyfUXWNh-5ms-nnY5drZYYuaV-AZF_9YzQMB-2R-ZDBxB8ddZVtV4jpmGsxZLPcB-zcrm4Nqn2LVHvRiLYLzdGVlhZhzghH-3rge13CBrSqbHJ3tASgM0q6er39hAsAKj_eEoPJ40cuyqg9e1T5sk8OC2OGX5gfjrl-0O6WVHVqUdoBneaLHc5x9OEHumeHHXxDJlX2QKdLVN8eHlPQ8xZ7Wpijh-45-JH6ziK6UTIZelr3CHeR1SRArtwELBmwxqRD_r9sctTzNXs576-XEm2d5OxlGikd7RKbS9JH2lELTCpz3LV7O8vLRM/7773548709664034561/843139428 |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 7:48pm On Oct 16, 2019 |
SolnergyPower: Please share stats with us. |
Re: Solar Energy, A Complement To FTA by ceaser: 7:59pm On Oct 16, 2019 |
BetaTechnicians: Well, generally Modified Sine inverters always output rough, jagged RMS in their AC output while PSW inverters have fine outputs. Some Modified Wave inverters have cleaner output than others and therefore can still be used within safety limits for some equipments than those with rougher outputs. And with all modified wave inverters, while it may work with your capacitance loads or IC loads like TVs, sound systems and laptops, what you get is undesirable humming feedbacks in the circuit that manifests as lound hums from the TVs or sound system. I have experimented a Modified PWM with a table fridge once before and while it worked for a day, the compressor got unbearably hot, something I believed was due to the modified wave input from the inverter. I have placed an automatic gate opener (with AC RMS motor) on a modified wave inverters and it worked but there is this same high humming sound that the motor makes when it works. You can safely use a modified inverter with most rugged TVs and even with most decoders (since their power pack is external) but most other sensitive equipments may have shortened lifespan. |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 8:09pm On Oct 16, 2019 |
earthrealm: |
Re: Solar Energy, A Complement To FTA by ceaser: 8:30pm On Oct 16, 2019 |
earthrealm: With that your link that you posted, you're not even worried about that bot that bans arbitrarily. I dislike that bot with passion. |
Re: Solar Energy, A Complement To FTA by Oshomo12(m): 10:20pm On Oct 16, 2019 |
zeestone99: Sorry my brother, just trying to make him see that his system at that instant current of about 20A is quite disheartening If he has very good panels(Trina, Canadian, etc, of 600w at 12V I may accept 43A instantaneous current, but I will push for around 46A). For a 24v system of 510 w panel, around 26 v, I have seen/recorded 20A instant current and it was steady for about 1 min. |
Re: Solar Energy, A Complement To FTA by Oshomo12(m): 10:34pm On Oct 16, 2019 |
SolnergyPower: This is the efficiency of the panels (min I can take), so ur 600w panel @ 80% will now be 480w (if u install tier 1 solar panels, u can get more than this). ur distance is quite high 15 m, that is when u need to install mppt controller(they are made for this kind of situation) @bolded 480w(I*V)/14.2(V) u should get 34 A, thereabout (which is still not acceptable by me). |
Re: Solar Energy, A Complement To FTA by Wazari: 1:59am On Oct 17, 2019 |
SolnergyPower: SolnergyPower, you have a fundamental misunderstanding of what PWM is and how it works. Connecting your panel in series as long as it is below the maximum allowed by the controller will work but will not give you the best yield. If you connect panels in series to give 150v and connect via a pwm controller to a 12v battery, your whole pv string will produce power at 12v which will be very inefficient. What this means is that if you connected 4 panels to get 150v, then each panel is operating at 3v each. To understand why this is a bad idea you need to check the power curve of a pv panel. On the flip side, if the panels are connected in parallel (as long as Voc is higher than battery voltage), each panel will work at 12v and have a higher yield on its power curve. Pls check the PV voltage on the charge controller with a multimeter and see if it is the same as the battery voltage. 4 Likes |
Re: Solar Energy, A Complement To FTA by mctfopt: 3:50am On Oct 17, 2019 |
SolnergyPower: I guess since the 150w by 4 = 600w, at 80% efficiency, i.e 80% of 600w, we have 480w. Given that the system is 12v, at bulk charging stage you should have around 14.2v for gel battery. Therefore using the Ohms law, current (I) = 480w÷14.2v = 33.80A which I guess got approximated to 35A Edit: my bad, someone already answered it. 5 Likes |
Re: Solar Energy, A Complement To FTA by JUO(m): 8:08pm On Oct 17, 2019 |
wilfrik200:I have done that |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 8:41pm On Oct 17, 2019 |
Here us the link for the recorded morningstar corp webinar, those interested in understanding thoroughly this mppt, pwm and other solar issues should try and listen to it. Lemme know if the link isnt working so i try another method. https://attendee.gotowebinar.com/recording/viewRecording/7773548709664034561/4347555140372977676/aionline@yahoo.com?registrantKey=8818820329706734349&type=ATTENDEEEMAILRECORDINGLINK 2 Likes |
Re: Solar Energy, A Complement To FTA by BetaTechnicians: 6:52am On Oct 18, 2019 |
ceaser: It is good to experiment and have first hand experience but you should do it with the metrics in mind, remember that majority of those timers were designed for AC circuits and those designed for DC and the relay in them can handle little DC currents, also remember that it takes a lot to extinguish a DC arc which is why we have dedicated DC breakers. |
Re: Solar Energy, A Complement To FTA by BetaTechnicians: 6:54am On Oct 18, 2019 |
ceaser:I appreciate the share |
Re: Solar Energy, A Complement To FTA by BetaTechnicians: 6:57am On Oct 18, 2019 |
Penuelseun: Can you please be more open with this hack, the process and more pictures or kindly point me to where there's a better tutorial for it. Thanks. I'll prefer this for some smaller setups than having two smaller panels. |
Re: Solar Energy, A Complement To FTA by Penuelseun(m): 7:31am On Oct 18, 2019 |
BetaTechnicians:start with this https://www.instructables.com/id/How-to-change-36V-to-12V-Solar-Cell/ 2 Likes |
Re: Solar Energy, A Complement To FTA by idsolar(m): 11:13am On Oct 18, 2019 |
Topmost11: yes. I believe what u are thinking is that if d system is 12v u should have panel exactly 12v. no sir. ur panel is for 12v setup while a 24v setup panels volt range higher up to 38v. now ur CC is ok. u can use it for 12v or 24v setup as far as u maintain setpoint of 50volt. |
Re: Solar Energy, A Complement To FTA by tchijioke: 1:51pm On Oct 18, 2019 |
Warm greetings to all the gurus that's giving life to this thread... Pls I need your input to get the best possible setup with the available items: 1. 40amps mppt charge controller. Find detailed spec in pix attached 2. 6pcs 200watts solar Panels. Find detailed spec in pix attached. Spec: Vpm =36.21v, Ipm=5.11amp 3. 12v battery bank already installed QST: what would be the best panel connection/arrangement for optimal performance. Thanks in advance for your responses.
|
Re: Solar Energy, A Complement To FTA by Penuelseun(m): 5:40pm On Oct 18, 2019 |
tchijioke:I don't think your cc can handle the current that the panel can produce for a 12v system(about 60amp simultaneous current on a good day) How many batteries do you have by the way? You will be better off with a 24v system, but if you want to go ahead, you can go with a 2s3p configuration 1 Like |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 6:40pm On Oct 18, 2019 |
ONE WEEK PROMO !!! Schneider 1500va 24v pure sinewave solar Inverter .... Unit price:N68,000 Kindly Contact, Smartcellglobal 08135031951 2 Likes
|
Re: Solar Energy, A Complement To FTA by ojeysky(m): 7:55pm On Oct 18, 2019 |
dragnet: Bros please can you tell me which of the options in the URL would match the attached picture
|
Re: Solar Energy, A Complement To FTA by Papertrail11(m): 1:25am On Oct 19, 2019 |
Hello folks, I ama noob when it comes to solar power technicalities but i have series of questions i would love to ask with regards solar What is the best config to consider for going totally offgrid I have 2 tvs about 20lights fans, 3fans, xbox, a fridge, AC conditioner some phone ports to charge how many solar panels would i need. Based on the appliances i have how many hours on an avg can i power my house for. Which is the best quality of solar panels to consider in the market. |
Re: Solar Energy, A Complement To FTA by ojeysky(m): 1:50am On Oct 19, 2019 |
Papertrail11: You need to provide more details, will all the bulbs remain on at the same time? What's your concurrent total wattage? How many hours on power supply do you desire in a day? as it's easier to plan with those information. That said, my quick take is that you remove those 2 items in bold from your list then your budget will be less 1m but with those 2 items, you are looking at over 2m budget to get reasonable number of hours in a day. |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 8:39am On Oct 19, 2019 |
USA Trojan SPRE 12 225 (Solar Premium Line Flooded Battery 12V 225Ah) Availability: In stock PRICE: ₦140,000.00 Quick Overview, Model: SPRE 12 225 Voltage: 12 Battery: Deep Cycle Flooded/Advanced Lead-Acid Battery Capacity: 12V 200Ah / 20Hr Rate Cyclic Use: 30% DOD - 3500 cycles Cyclic Use: 50% DOD - 1900 cycles Dimensions (LxBxH): 380mm x 176mm x 351mm Terminal Height: 374mm Weight: 60kg Absorbtion Charge: 14.7V, Float charge: 13.5V, Equalization Charge: 16.20V Color: Maroon Material: Polypropylene Contact: Smartcellglobal services 08135031951 WHATSAPP::: https:///2348170385620 1 Like
|
Re: Solar Energy, A Complement To FTA by dragnet: 9:20am On Oct 19, 2019 |
ojeysky:it is complicated because the ones in the link are all in parallel but the one in the shared picture has both series and parallel connection. |
(1) (2) (3) ... (598) (599) (600) (601) (602) (603) (604) ... (1854) (Reply)
FTA Live Football Matches Announcement Thread / Free To Air Satellite Tv General Thread
Viewing this topic: zeestone99(m) and 1 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2024 Oluwaseun Osewa. All rights reserved. See How To Advertise. 61 |