Re: Solar Energy, A Complement To FTA by justcallmenuel(m): 8:20am On Jun 26, 2024 |
8kva 48v felicity ivem hybrid inverter available, #1,100,000. Call/WhatsApp me on 08168986461 1 Like
|
Re: Solar Energy, A Complement To FTA by HeavenlyBang(m): 8:20am On Jun 26, 2024 |
justcallmenuel: That's the largest wattage panel I've seen so far. |
Re: Solar Energy, A Complement To FTA by Ooreofegrace: 8:43am On Jun 26, 2024 |
Good day bosses in the house... Abeg make una help me with solutions to the below problem .. Did 4.2kw 24v installation with two 220ah tubular batteries abt 2mths ago. Now the customer sent me a message this morning that for abt one week now the batteries goes off around 2-3am with just DC bulb load (10pices of 5W each). Load use on the battery.. 1HP pumping machine.. Once in abt 3 and days,running hrs like 1hr max during the day. Inverter fridge and freezer from 8am to 6pm now reduced to 3pm And the DC bulb for night useage.. Kindly note that the batteries get alot of charge before the sun goes of.. It always in the float state before it comes down to the normal 50% battery level and still sound for low battery warning even without much load around 3am max.. What can i do to rewake or b boost the batteries pls..? Thanks all. |
Re: Solar Energy, A Complement To FTA by Drgreatone: 9:39am On Jun 26, 2024 |
Ooreofegrace:What type of inverter are u using and the nos/type of panels u used? Suspecting sms though. How are u sure they are not putting extra loads and not mentioning it. Its either that or the batteries aren't charging well sha 2 Likes |
Re: Solar Energy, A Complement To FTA by Drgreatone: 9:54am On Jun 26, 2024 |
Anyone used this controller before? The mppt has solid history so hoping this wont disappoint. Like the LiPO4 ability.
|
Re: Solar Energy, A Complement To FTA by Haykay2001: 9:57am On Jun 26, 2024 |
.. Drgreatone: |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 10:02am On Jun 26, 2024 |
Ooreofegrace: U DIDNT MENTION ANYTHING about solar panels?. max load you shud put on the system without damaging it is 20amps x 24volts wch is about 500watts....that pumping machine, have you checked the actual draw?..same for the freezer. what of battery charge voltage algorithm...what voltages did u set the inverter to?..abi you just left it on default? check the SG of the battery electrolyte with a hydrometer and be sure its good |
Re: Solar Energy, A Complement To FTA by HeavenlyBang(m): 10:15am On Jun 26, 2024 |
earthrealm: Umm, explain this. Why? 1 Like |
Re: Solar Energy, A Complement To FTA by Drgreatone: 10:25am On Jun 26, 2024 |
HeavenlyBang:Using the recommended C10 discharge rate for tubular batteries 4 Likes |
Re: Solar Energy, A Complement To FTA by bigrovar(m): 10:27am On Jun 26, 2024 |
jonescosmos: Besides, the bigger danger is the earth is not energized which should never be the case especially when you consider lots of appliances and metal frame are suppose to be connected to earth. This is why RCD is very important for a TT system. It is meant to spot a differential between live and neutral then trip to ensure safety. |
Re: Solar Energy, A Complement To FTA by Ooreofegrace: 10:45am On Jun 26, 2024 |
Hybrid Inverter.... Wilion 4.2kw Jinko panel.. 580w x3.. Brand new..all in series input volt btw 130v and 150v It's always on flot 27. v during suning hrs even with pumping machine on it.. No additional load.. Their tv is 35w..32" led TV which they use only during the weekend in the afternoon.. Drgreatone: |
Re: Solar Energy, A Complement To FTA by Ooreofegrace: 10:51am On Jun 26, 2024 |
Panels are 568w x3 The only heavy load put on the system is the pump.. Which is abt 750 or so watt.. The fridge and freezer is inverter which sometimes stayed btw 114 and 60w.. Tv is below 30w also decoder.. Then bulbs.. Abt the charging parameters, it was left on default. Will hv to get battery charger to check the level.. earthrealm: |
Re: Solar Energy, A Complement To FTA by earthrealm(m): 11:04am On Jun 26, 2024 |
Ooreofegrace: ok panels check out, WELION inverter, you need to put it on flooded battery setting, not default or choose user and set bulk to 14.7v and float to 13.8v........and activate equalization immediately and set monthly equalization too for 4hrs at 31v. am assuming the batterys are brand new, so electrolyte SG is correct, just that its not being charged and mixing well cos of the low/wrong voltage. higher/correct charge voltage and the periodic equalization shud sort you out real quick.. your leaving the inverter on default is the likely cause of this issue, and most average installers are guilty of this as well. also the pump load is a bit high, but if you run it only during the day, with solar panels kicking in juice, you shud be fine 3 Likes |
Re: Solar Energy, A Complement To FTA by Dam5reey(m): 11:17am On Jun 26, 2024 |
Ooreofegrace: you are running about a 1KW load on 2 Tubular batteries. this is a stale story. these batteries are for light loads. 1 Like |
Re: Solar Energy, A Complement To FTA by Dam5reey(m): 11:30am On Jun 26, 2024 |
Drgreatone: This will work as a PWM charging, nothing much to expect. it has an LFP profile so you can configure it to charge based on 2 two-stage LFP CC/CV charging methods. |
Re: Solar Energy, A Complement To FTA by S007: 11:39am On Jun 26, 2024 |
justcallmenuel: This is a joke.... Right ![]() Just asking 1 Like |
Re: Solar Energy, A Complement To FTA by Drgreatone: 11:52am On Jun 26, 2024 |
bigrovar:Just saw this RCD, looks like what installers use as breaker between high voltage inverter and battery |
Re: Solar Energy, A Complement To FTA by FEGEITOK: 12:08pm On Jun 26, 2024 |
Trippledots: The grid connection was an oversight. I intended to disconnect. This isn't my first time traveling and leaving the stuff connected. I don't know if it makes a difference but my house is next to an AEDc transformer. And I know they do proper earthing for those things. One of the transformer earth rods in my compound. I'll seek advice if I can link my own earthing to that one. |
Re: Solar Energy, A Complement To FTA by Ooreofegrace: 2:52pm On Jun 26, 2024 |
Thanks alot for this chief.. Will go back there and run this steps.. earthrealm: |
Re: Solar Energy, A Complement To FTA by Ooreofegrace: 2:55pm On Jun 26, 2024 |
Are you saying two 220ah tubular batteries can comfortably run 1HP pumping machine? will tell them to use gen for now and study the set up,although hv always run my installation with pumping machine and other low load and it runs fine for yrs with no issues. Dam5reey: |
Re: Solar Energy, A Complement To FTA by Drgreatone: 3:17pm On Jun 26, 2024 |
Dam5reey:Just want something as back up if the day ever comes that my hybrid inverter decides to act up as I already av a back up inverter |
Re: Solar Energy, A Complement To FTA by Namzy(m): 4:36pm On Jun 26, 2024 |
Ooreofegrace: A battery can be 70% charged and charge controller will enter float especially those charge controllers that don't have automatic absorption time. So you can deplete your battery and the next day your default 2 hours absorption time won't even take the battery pass 70% before the charge controller enters float because the 2 hours of absorption has reached you should get a battery monitor with lead acid battery. Another crude method is when the charge controller is in float, switch off the inverter and check how many watts the charge controller uses to maintain the float voltage if it's above say 200w or more then you have a long way to go 2 Likes |
Re: Solar Energy, A Complement To FTA by Dam5reey(m): 5:00pm On Jun 26, 2024 |
Namzy: this is what most don't take note of, you cant really know the SOC on the lead Acid unless there is a capacity meter that most don't use. people will assume they only pump during the day without noting that battery maybe on float and it will take some time for controller to go back to bulk harming the batteries without knowing. Because of poor charging algorithm, efficiency tubular and lead acid is just a no no for me. especially in 2024 where price of LFP has fallen. 1 Like |
Re: Solar Energy, A Complement To FTA by FEGEITOK: 5:26pm On Jun 26, 2024 |
brightk: fegeitok at Yandex dot com |
Re: Solar Energy, A Complement To FTA by gadgetplanetng: 5:27pm On Jun 26, 2024 |
What does this mean on an Axpert inverter? It's been this way all day today The solar charging line isn't showing
|
Re: Solar Energy, A Complement To FTA by Dam5reey(m): 5:46pm On Jun 26, 2024 |
gadgetplanetng: what is the PV input Voltage, snap the side of the inverter where the specifications are. show the PV voltage page on the inverter as well. what is your panel configuration, total voc. It may mean the starting voltage has not reached yet. this is what I experienced at some point. the starting voltage is 150V. I watched the PV input voltage reach 149, but it didn't start. 1 Like |
Re: Solar Energy, A Complement To FTA by Drgreatone: 5:49pm On Jun 26, 2024 |
gadgetplanetng:Could be cloudy or shadows on ur panel so its not supplying |
Re: Solar Energy, A Complement To FTA by gadgetplanetng: 6:10pm On Jun 26, 2024 |
I've attached the photos. It might be the weather very cloudy today I noticed it some days ago too when my battery was full but once I put load on it it started charging again so was confused seeing it today weather is dull. Dam5reey: It's really cloudy today though. Drgreatone:
|
Re: Solar Energy, A Complement To FTA by Dam5reey(m): 6:28pm On Jun 26, 2024 |
gadgetplanetng: Zero Current from PV is interesting. |
Re: Solar Energy, A Complement To FTA by zeestone99(m): 6:30pm On Jun 26, 2024 |
Hello House The following are available now. INVERTER Sukam falcon 1kva/12v pure sine wave inverter - 140k Mpower 1.1kva/12v pure sine wave inverter - out of stock Afripower 1.7kva/24v pure sine wave inverter - 225k Afripower 2kva/24v pure sine wave inverter - 240k Afripower 2.5kva/24v pure sine wave inverter - 290k Cloud 1kva 50a pwm solar hybrid inverter - 175k 2kva 12v sunfield 80a mppt hybrid inverter - 295k Welion 4.2kva 24v 120a mppt solar hybrid inverter - 420k 6.2kva E-way 120a mppt hybrid inverter - 550k 8.2kva E-way 160a mppt inverter (2 trackers ) - 750k Sunmart vmii 5.5kw 48v 100a hybrid inverter 500vdc - out of stock Sunmart Vmii 3.5kw 24v 100a hybrid inverter 500vdc - 490k Sunmart Vmiii plus 3.5kw 24v 100a hybrid inverter 500vdc - 515k Sunmart Vmiii plus 5.5kw 48v 100a hybrid inverter 500vdc - (out of stock) Sorotec Revo Vmii 5.5kw 48v 100a hybrid inverter 500vdc - (out of stock) Sorotec Revo Vmii 3.5kw 24v 100a hybrid 5500w mppt inverter 500vdc - Sorotec 5.5kw 48v 100a hybrid 5500w mppt inverter 500vdc parallel version (includes parrallel kit) - 730k Sorotec 3.5kw 24v 100a hybrid 5500w mppt inverter 500vdc parallel version (includes parrallel kit)- 560k Sorotec Revo vmiii 5.5kw 48v 100a hybrid inverter 500vdc - out of stock Sorotec Revo vmiii 3.5kw 24v 100a hybrid inverter 500vdc - 560k Sorotec Revo vmiv 5.6kw 48v 120a hybrid inverter 500vdc (RGB LED LIGHTS) - out of stock Sorotec Revo vmiv pro 6kw 48v 120a hybrid inverter 500vdc RGB LED LIGHTS (dual outputs, smart load management) - 750k Powmr 3.2kva 24v 80a 450vdc mppt hybrid inverter - 370k Powmr 3.5kva 24v 100a 500vdc mppt hybrid inverter - 530k Powmr 5.5kva 48v 100a mppt hybrid inverter - 600k Snadi 2kva 24v inverter wall mount transformer based (works with lithium, can set LVD up to 24v) - 295k Snadi 3kva 24v inverter wall mount transformer based (works with lithium, can set LVD up to 24v) - 360k Snadi 3.5kva 24v inverter wall mount transformer based (works with lithium, can set LVD up to 24v) - 430k Snadi 5.5kva 24v inverter wall mount transformer (works with lithium, can set LVD up to 48v) - 580k Snadi 5.5kva 48v inverter wall mount transformer (works with lithium, can set LVD up to 48v) - 580k CHARGE CONTROLLER Epever triron 40a mppt charge controller - 170k Epever tracer 60a mppt charge controller - 285k Epever tracer 100a mppt charge controller - 450k Must 100a mppt solar charge controller - (out of stock) Must 60a mppt solar charge controller - 200k Must 80a mppt solar charge controller - (out of stock) Fangpusun flexmax 80a mppt charge controller - 450k Fangpusun flexmax 60a mppt charge controller - (out of stock) Fangpusun 50a 12/24v - 145k 40amps mppt lumiax Bluetooth controller(mobile app compatible)- out of stock 60amps lumiax Bluetooth mppt controller(Mobile app compatible) - 220k 40amps sunfield mppt controller - out of stock 80amps sunfield mppt charge controller - 220k 100amps sms mppt controller - 235k 140amps sms mppt controller 48v - 260k 60amps 12/24/36/48v powermr mppt new model - 140k Battery Cworth 5kwh 48v lifepo4 battery- 1.25m Cworth 5kwh 24v lifepo4 battery- 1.25m Cworth 10kwh 48v lifepo4 battery- 2.6m Cworth 15kwh 48v lifepo4 battery- 3.2m SMS 5kwh 48v lifepo4 battery- 1.23m Greenpole 48v 100ah 5kwh lithium battery - 1.55m Deye 5kwh lithium battery - ?? Kartel 220ah tubular battery - 290k Starplus 220ah tubular battery - 265k Mpower 220ah tubular battery - ?? AVR Avr(under n over voltage regulator)/current limiter 60a - 13k Avr(under n over voltage regulator)/current limiter 60a (Tomzn) - 15k Avr/current limiter/Energy meter 60a 3in1 (Tomzn) - 19k Avr (under n over voltage regulator)/current limiter 63a 4pole 3 Phase (tomzn) - 38k BREAKERS/SPDs Change over breaker/MTS - 8k Change over breaker/MTS 4pole - 18k DC SPD 500v - 13k DC SPD 500v (Tomzn) - 15k DC spd 1000v (tomzn)- 17k Ac spd 275v (worldsunlight )- 10k Ac spd 275v (tomzn) - 13k Ac spd 4 pole - 18k RCBO 63A TOMZN - 15K RCBO 63A 4POLE 3PHASE - 25K VOLTMETERS/ ENERGY METER DC Voltmeter (5v- 120v ) - 6k DC Voltmeter (8v- 100v / with battery indicator and %) - 8k (out of stock) DC Battery and energy Meter 200a - 25k 6 in 1 Ac Energy meter ( watts, voltage,kWh,amps, freq, power factor) - 28k Kill a Watt meter - 18k MC4 CONNECTORS Mc4 connectors - 1k Mc4 y connector 2 in 1 - 5k Mc4 y connector 3 in 1- 7k Mc4 y connector 4 in 1 - 13k PROGRAMMABLE TIMER Programmable timer 15a UK pkug - 13k Programmable timer 25a - 13k BREAKERS/ DC FUSE HOLDERS solar DC fuse holder 1 pole (tomzn) - 3.5k Solar DC fuse holder 2 pole (tomzn)- 6k Solar DC fuse (10a/16a/20a/25a/30a) - 2k DC breaker 10a 600v double pole (tomzn)- 8k DC breaker 16a 600v double pole (tomzn) - 8k DC breaker 20a 600v double pole (tomzn) - 8k DC breaker 25a 600v double pole (tomzn) - 8k DC breaker 125a double pole (tomzn) - 14k DC breaker 125a single pole (tomzn) - 8k DC breaker 100a double pole (tomzn) - 13k DC breaker single pole (32-63a) - 3.5k DC breakers double pole 63a - 7k DC breakers double pole 40a - 7k DC breaker double pole 100a - 12.5k Dc breaker double pole 125a - 13k 250a DC mccb breaker double pole (Tomzn) - 37k 250a DC mccb breaker double pole (CSQ) - 35k 125a DC mccb breaker double pole (CSQ) - 25k Ac breaker double pole 10a (Tomzn)- 6k Ac breaker double pole 16a (Tomzn)- 6k Ac breaker double pole 32a (Tomzn)- 6k Ac breaker double pole 63a (Tomzn)- 6k Ac breaker double pole 10a (Chint)- 6.5k Ac breaker double pole 16a (Chint)- 6.5k Ac breaker double pole 32a (Chint)- 6.5k Ac breaker double pole 63a (Chint)- 6.5k BATTERY EQUALIZER Ha02 battery balancer 48v - out of stock Ha02 battery equalizer 24v - out of stock AUTOMATIC TRANSFER SWITCH(ATS) Automatic transfer switch (ATS) din rail 100a (tomzn) - 38k Automatic transfer switch (ATS) 125a din rail (tomzn) - 39k Automatic transfer switch (ATS) 63a wall mount (tomzn) - 45k Automatic transfer switch (ATS) 125a wall mount (tomzn) - 48k Automatic transfer switch (ATS) 100a 4pole 3 phase 4 pole din rail (tomzn) - 60k Automatic transfer switch (ATS) 125a 3 phase 4pole wall mount (tomzn) -70k ENCLOSURE BOX/ BUSBAR 4way breaker enclosure - 4k 6way breaker enclosure - 5k 8 way breaker enclosure -7k 12 way breaker enclosure - 9k Busbar (Red and Black) imported - 38k Busbar +ve and -ve (local) - 23k Battery terminal ( Red and Black) - 5k DM for other items. Call/chat - 08 one 1739 829 four
|
Re: Solar Energy, A Complement To FTA by gadgetplanetng: 6:31pm On Jun 26, 2024 |
I'm suspecting there's an error somewhere. I turned off the breaker for the panels but nothing changed. I'd wait when it's dark and turn off the battery let me see what happens in the morning. Dam5reey: |
Re: Solar Energy, A Complement To FTA by isangjohnson: 8:09pm On Jun 26, 2024 |
Ooreofegrace:The person you did the installation for may be having serious issue with load management. You're not there with them and I'm very sure their consumption is more than what they reported to you. What is the idle power consumption of the 4.2kva 24v inverter? The max inverter capacity I give for 24v system is 3.2kw. In summary, add the inverter idle power consumption, add the hidden loads, reduce the 50% usable dod battery capacity to 75%, and you will know what to tell them. I may not know the name of your tubular batteries and I may not know the purchase source as well but you should know that about 80% of these product's capacity are overrated. My first installed system has 4 pcs of 230ah Genus tubular batteries with 5.5kwh usable dod capacity but I reduced the usable capacity to 4.1kwh (75%) and I've never discharged them below 60%. This is what made the batteries to last till I sold them and the person who bought them are still using them today without any issue. Advise them to buy a good battery meter reading like Victron BMV. The 1Hp pump maybe consuming 1kw depending on the distance of the installed machine and the cable size and parts of the consumption may as well pick up from the battery without their knowledge. 1 Like |
(1) (2) (3) ... (1753) (1754) (1755) (1756) (1757) (1758) (1759) ... (1997) (Reply)
Free To Air Satellite Tv General Thread
Viewing this topic: inspired4real, KaylaDeriy(f) and 2 guest(s)
(Go Up)
Sections: politics (1) business autos (1) jobs (1) career education (1) romance computers phones travel sports fashion health religion celebs tv-movies music-radio literature webmasters programming techmarket Links: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Nairaland - Copyright © 2005 - 2025 Oluwaseun Osewa. All rights reserved. See How To Advertise. 102 |