Re: Solar Energy, A Complement To FTA by rhosymedre: 7:38am On Oct 08 |
bassdow:
These should do. Guess the pumping machine is between 0.5, 0.75 and 1HP. Probably run the heavier items during the day Thanks again, appreciated. I will still be grateful for further input especially on this issue: " I am confused whether 2 x 200ah Lifepo4 will be enough or whether a single 7.5kwh Lifepo4 battery is necessary ...." |
|
Re: Solar Energy, A Complement To FTA by HeavenlyBang(m): 9:26am On Oct 08 |
rhosymedre:
Thanks again, appreciated.
I will still be grateful for further input especially on this issue: " I am confused whether 2 x 200ah Lifepo4 will be enough or whether a single 7.5kwh Lifepo4 battery is necessary ...."
Lifepo4 batteries are built for different voltages, unlike tubular that's only in 12v. You have to be more specific than "2x200ah". A 12v 200aH Lifepo4 battery is 2.56kwh A 24v 200aH is 5.12kwh A 48v 200aH is 10.24kwh 2 Likes |
Re: Solar Energy, A Complement To FTA by Sakopower: 9:45am On Oct 08 |
Sako always available for your power backup needs. Call/Whatsapp: 08033213577 |
Re: Solar Energy, A Complement To FTA by GloryJoyeux: 10:01am On Oct 08 |
rhosymedre: Hello everyone, both expert contributors and all others.
I have been quietly reading here for some time to learn more. I would be grateful for your help on one or two things.
1. What really is the capacity of a 200ah Lifepo4 battery? We are planning a system, excluding air conditioners, with four 580w Jinko panels and a 7.5kva Inverter; I am confused whether 2 x 200ah Lifepo4 will be enough or whether a single 7.5kwh Lifepo4 battery is necessary as someone has suggested to me.
2. Please advise on whether the Felicity Lifepo4 batteries are reliable.
3. Please advise on whether the Felicity 7.5kva transformer based inverter is reliable.
Many many thanks in advance. Hello, When sizing your system an energy consumption audit is one of the most crucial steps. I can see that you also listed the electrical loads you intend on carrying in a latter post. Although this is different from a comprehensive energy consumption audit, I will work with that figure. Firstly, you must understand there is always a strong tendency to improve on a solar system after it has been installed so a lot of folks just go big from the get go if they are able to afford it. A crucial question is: are you sure you really do not ever want to run that air conditioner? I’m asking because it seems like you really want it included, but the truth is, if you want it down the line, you will have to upgrade your system. Now, the ability to upgrade your system down the line is also a major advantage of residential ess, it means you can do what you can afford now and with time get to were you want it to be. Answering your questions: I will assumes you are comparing 48v batteries because using a 7.5kw inverter with anything less than 48v batteries system is poor design choice. Battery size : Two paralleled 200ah battery is 51.2v x 400ah = 20kwh. That is over double the capacity of a single 7.5kwh battery. Both of these can power your air conditioner and other systems mentioned during the day with your 7.5kw inverter. However, at night, if you use the air conditioner with the 7.5kwh battery, you will quickly run out of stored energy. But the 20kwh battery will be more than enough to run your ‘inverter’ air conditioners over night. By now I’m sure you are understanding the concept? Bigger batteries mean more energy stored for when there is no sunlight, it means longer run time of electrical load and means an extra day or two of autonomy. Days of Autonomy : this is also a major factor when designing systems. In Nigeria right now we are at the raining season and this means poor solar yield. You therefore need to design a system that can go through at least a day of poor solar yield i.e. a full raining day where your batteries would just add 10 percent charge. The larger 20kwh battery will enable you to plan 12kwh for the night, and the balance 8kwh for the next night incase there is poor solar yield due to rainfall. The 7.5kwh battery means you will have to plan 4.5kwh for the night and 3kwh for the next night incase of poor solar yield. Now, it all depends on energy consumption. Someone might be very okay on 7.5kwh inclusive of days of autonomy, while another will be okay with 20kwh, some have up to 90kwh as home ess. Solar generation : I see you listed 4 units of 580w solar panels. This is 4 x 580w =2,320 W. Now, you must understand that you will hardly get a sustained 2,320w of solar yield. Always aim for 90 percent solar yield which is 0.9 x 2320w =2,088 W. Now you must consider inefficiencies when converting current and voltage to charge the batteries. Expensive inverters and solar charge controllers like those made by victron offer way higher conversion efficiency. But, most cheaper inverters we use offer poor efficiency. So let’s go with 85 percent conversion efficiency. We have 0.85 x 2088w=1,774.8 W. Since you battery is 51.2v, it will charge at average of 53v so we have, 1,774.8w / 53v = 33.4 amps. Take note of the figure 33.4 amps. If you go with the 7.5kwh battery which is 150ah. It will take up to 150ah / 33.4amps = 4.5hrs sunlight to charge. Now notice if you go with the 20kwh battery which is 400ah it will take up to 400ah / 33.4amps = 12hrs sunlight to charge This above is only accurate if you are not running a single day time load. Once you are running a load during the day eg your freezer is turned on. Then, your 1,774.8w from solar panel will need to power those loads first, before sending the balance to the battery, meaning you will be looking at 27amps or even just 25amps charging current. Now, not all sunlight is equal. Just because it’s daytime doesn’t mean you will be generating such high sustained figures. For a fact, you can only expect such sustained performance all day only during the dry season in the south, except you are living up north in Nigeria. We can therefore conclude that your solar panel is completely underpowered. How to size your solar panels : I will give you my personal calculation that works for me always. If you are resident in the south of Nigeria, size your panels to fully charge your batteries with just 1.8hrs of sunlight i.e 1hr 48mins of sustained peak solar pv should charge your battery to full. If you are in the North use 2.5hrs of sunlight for your calculation. This means that, to size your panels divide your total battery capacity by 1.8 if you live in the south and 2.5 if you live in the north. So 20kwh battery / 1.8 = 11,000w total panels and 7.5kwh battery / 1.8 = 4,160w total panels. I can assure you, if you size your panels this way and factor in days of autonomy for battery size. Come rain come sun, out of 365 days a year, you will always get full charge for a minimum of 340 days. The remaining less than 25days which translates to 4 times a month in the rainy season, you can expect minimum of 50 percent charge. Regarding questions 2 and 3. Do not buy from some alaba marketers, to be safe just go straight to their official distributors and buy from them. I have seen situations where they print new stickers with higher capacity and paste on their batteries to deceive unsuspecting customers. Do you research and ensure you purchase from the right source or you will not get value for your money. For the inverter part, you can maybe google search the name of the inverter and add words like ‘repair’ , ‘fault’ , ‘common issues’, ‘problems’ and see if you can find any known issues documented online. This is a neat trick for researching any electrical device you intend to buy. *sorry for any typos, I didn’t proofread this. 19 Likes 3 Shares |
Re: Solar Energy, A Complement To FTA by bassdow: 10:21am On Oct 08 |
rhosymedre:
Many thanks for reply.
For now we have decided to exclude air conditioners; so, something like
* 1 medium/large TV e.g. 40 inches and 4 small TVs of 24 inches each * 1 standard fridge (nothing big) and one small deep freezer * 1 water pumping machine * About 8 standing fans (will go for low power consuming fans) * All electric bulbs in a 5 bedroom house
Thanks again. Mentioning appliances such as Fridge or Freezer, or even Pumping machine, without mentioning their capacities means we either make guesses or give information that could end up being wrong. We don't even know if your pumping machine is surface or submersible, let alone knowing it's capacity. Even TV's power rating needs be stated as I have seen TVs that consume power like community cinema. At end of the day, a larger battery bank would always server better than a smaller one irrespective of the number of units. In other words, 2pcs of 12v 200AH battery would always out perform 1pcs of 200AH battery all things being equal. Now you probably are comparing 2 types of batteries => Lithium and Tubular/GEL/AGM batteries. Just understand that quality Lithium batteries gives much more power than Tubular/GEL/AGM of comparable capacity. Note: I didn't just say Lithium battery is superior BUT I said Quality Lithium battery Major advantage Lithium technology has over Tubular/GEL/AGM is, you could run Lithium batteries lower (though help if you don't) BUT for the likes of Tubular/GEL/AGM batteries, you need ensure you don't run beyond 50% of it's stated capacity else it wouldn't be there to serve you for long. NB: A lot of us want to quickly respond to comments and get on our way. Abeg no give us reason to stress our brain unnecessarily. Consuming information such as "2pcs of 12v 200AH battery" is much quicker than saying "4.8kwh" BECAUSE we have to mentally do things such as convert 12-volts 200AH to kWh i.e; 200AH x 12v = 2,400 watts ÷ 1000 = 2.4 kWhAnyway sha, the 2pcs of 200Ah batteries is much smaller and wouldn't last long in terms of years.. You would have better luck going with the 7.5kwh battery so long it ain't over-rated or low quality. Once again, the above information could be wrong as capacity of the appliances especially the Fridge , Freezer , and Pumping machine weren't mentioned. Didn't even ask how long you intends powering them daily sef. 2 Likes |
Re: Solar Energy, A Complement To FTA by bassdow: 10:35am On Oct 08 |
GloryJoyeux:
Hello,
When sizing your system an energy consumption audit is one of the most crucial steps. I can see that you also listed the electrical loads you intend on carrying in a latter post. Although this is different from a comprehensive energy consumption audit, I will work with that figure.
Firstly, you must understand there is always a strong tendency to improve on a solar system after it has been installed so a lot of folks just go big from the get go if they are able to afford it.
A crucial question is: are you sure you really do not ever want to run that air conditioner? I’m asking because it seems like you really want it included, but the truth is, if you want it down the line, you will have to upgrade your system. Now, the ability to upgrade your system down the line is also a major advantage of residential ess, it means you can do what you can afford now and with time get to were you want it to be.
Answering your questions:
Battery size : Two paralleled 200ah battery is 51.2v x 400ah = 20kwh. That is over double the capacity of a single 7.5kwh battery. Both of these can power your air conditioner and other systems mentioned during the day with your 7.5kw inverter. However, at night, if you use the air conditioner with the 7.5kwh battery, you will quickly run out of stored energy. But the 20kwh battery will be more than enough to run your ‘inverter’ air conditioners over night.
By now I’m sure you are understanding the concept? Bigger batteries mean more energy stored for when there is no sunlight, it means longer run time of electrical load and means an extra day or two of autonomy.
Days of Autonomy : this is also a major factor when designing systems. In Nigeria right now we are at the raining season and this means poor solar yield. You therefore need to design a system that can go through at least a day of poor solar yield i.e. a full raining day where your batteries would just add 10 percent charge.
The larger 20kwh battery will enable you to plan 12kwh for the night, and the balance 8kwh for the next night incase there is poor solar yield due to rainfall.
The 7.5kwh battery means you will have to plan 4.5kwh for the night and 3kwh for the next night incase of poor solar yield.
Now, it all depends on energy consumption. Someone might be very okay on 7.5kwh inclusive of days of autonomy, while another will be okay with 20kwh, some have up to 90kwh as home ess.
Solar generation : I see you listed 4 units of 580w solar panels. This is 4 x 580w =2,320 W. Now, you must understand that you will hardly get a sustained 2,320w of solar yield. Always aim for 90 percent solar yield which is 0.9 x 2320w =2,088 W. Now you must consider inefficiencies when converting current and voltage to charge the batteries. Expensive inverters and solar charge controllers like make by victron offer way higher conversion efficiency. But, most cheaper inverters we use offer poor efficiency. So let’s go with 85 percent conversion efficiency. We have 0.85 x 2088w=1,774.8 W. Since you battery is 51.2v, it will charge at average of 53v so we have, 1,774.8w / 53v = 33.4 amps.
Take note of the figure 33.4 amps. If you go with the 7.5kwh battery which is 150ah. It will take up 150ah / 33.4amps = 4.5hrs sunlight to charge. Now notice if you go with the 20kwh battery which is 400ah it will take up to 400ah / 33.4amps = 12hrs sunlight to charge
This above is only accurate if you are not running a single day time load. Once you are running a load during the day eg your freezer is turned on. Then, your 1,774.8w from solar panel will need to power those loads first, before sending the balance to the battery, meaning you will be looking at 27amps or even just 25amps charging current.
Now, not all sunlight is equal. Just because it’s daytime doesn’t mean you will be generating such high sustained figures. For a fact, you can only expect such sustained performance all day only during the dry season in the south, except you are living up north in Nigeria.
We can therefore conclude that your solar panel is completely underpowered.
How to size your solar panels : I will give you my personal calculation that works for me always. If you are resident in the south of Nigeria, size your panels to fully charge your batteries with just 1.8hrs of sunlight i.e 1hr 48mins of sustained peak solar pv should charge your battery to full. If you are in the North use 2.5hrs of sunlight for your calculation.
This means that, to size your panels divide your total battery capacity by 1.8 if you live in the south and 2.5 if you live in the north. So 20kwh battery / 1.8 = 11,000w total panels and 7.5kwh battery / 1.8 = 4,160w total panels.
I can assure you, if you size your panels this way and factor in days of autonomy for battery size. Come rain come sun, out of 365 days a year, you will always get full charge for a minimum of 340 days. The remaining less than 25days which translates to 4 times a month in the rainy season, you can expect minimum of 50 percent charge.
Regarding questions 2 and 3. Do not buy from some alaba marketers, to be safe just go straight to their official distributors and buy from them. I have seen situations where they print new stickers with higher capacity and paste on their batteries to deceive unsuspecting customers. Do you research and ensure you purchase from the right source or you will not get value for your money. For the inverter part, you can maybe google search the name of the inverter and add words like ‘repair’ , ‘fault’ , ‘common issues’, ‘problems’ and see if you can find any known issues documented online. This is a neat trick for researching any electrical device you intend to buy.
*sorry for any typos, I didn’t proofread this.
Have done things such as this which was even more straight to point. Issue is most ain't ready to read though all pages. Most don't have such patience. You posting this, would mostly generate a couple of LIKEs and SHAREs and that's it. Either way, we appreciate your time. As for your suggestion of Not buying from some Alaba marketers, abeg expand to inform them Alaba marketers are everywhere even inAbuja. Make dem no go dey think say na only for Alaba market. Most (or some) sha prefer to Fall first, before listening 3 Likes |
Re: Solar Energy, A Complement To FTA by GloryJoyeux: 11:02am On Oct 08 |
bassdow:
Have done things such as this which was even more straight to point. Issue is most ain't ready to read though all pages. Most don't have such patience. You posting this, would mostly generate a couple of LIKEs and SHAREs and that's it. Either way, we appreciate your time.
As for your suggestion of Not buying from some Alaba marketers, abeg expand to inform them Alaba marketers are everywhere even inAbuja. Make dem no go dey think say na only for Alaba market. Most (or some) sha prefer to Fall first, before listening “If any one wants to learn, he/she must be willing to read.” If anyone finds an article, book, story etc too long to read it simply means they aren’t fully interested in that particular thing. The long write up is for those interested and thus willing to read. What is of importance is that the information there in is accurate. 3 Likes |
Re: Solar Energy, A Complement To FTA by GloryJoyeux: 11:46am On Oct 08 |
GloryJoyeux:
Hello,
When sizing your system an energy consumption audit is one of the most crucial steps. I can see that you also listed the electrical loads you intend on carrying in a latter post. Although this is different from a comprehensive energy consumption audit, I will work with that figure.
Firstly, you must understand there is always a strong tendency to improve on a solar system after it has been installed so a lot of folks just go big from the get go if they are able to afford it.
A crucial question is: are you sure you really do not ever want to run that air conditioner? I’m asking because it seems like you really want it included, but the truth is, if you want it down the line, you will have to upgrade your system. Now, the ability to upgrade your system down the line is also a major advantage of residential ess, it means you can do what you can afford now and with time get to were you want it to be.
Answering your questions:
I will assumes you are comparing 48v batteries because using a 7.5kw inverter with anything less than 48v batteries system is poor design choice.
Battery size : Two paralleled 200ah battery is 51.2v x 400ah = 20kwh. That is over double the capacity of a single 7.5kwh battery. Both of these can power your air conditioner and other systems mentioned during the day with your 7.5kw inverter. However, at night, if you use the air conditioner with the 7.5kwh battery, you will quickly run out of stored energy. But the 20kwh battery will be more than enough to run your ‘inverter’ air conditioners over night.
By now I’m sure you are understanding the concept? Bigger batteries mean more energy stored for when there is no sunlight, it means longer run time of electrical load and means an extra day or two of autonomy.
Days of Autonomy : this is also a major factor when designing systems. In Nigeria right now we are at the raining season and this means poor solar yield. You therefore need to design a system that can go through at least a day of poor solar yield i.e. a full raining day where your batteries would just add 10 percent charge.
The larger 20kwh battery will enable you to plan 12kwh for the night, and the balance 8kwh for the next night incase there is poor solar yield due to rainfall.
The 7.5kwh battery means you will have to plan 4.5kwh for the night and 3kwh for the next night incase of poor solar yield.
Now, it all depends on energy consumption. Someone might be very okay on 7.5kwh inclusive of days of autonomy, while another will be okay with 20kwh, some have up to 90kwh as home ess.
Solar generation : I see you listed 4 units of 580w solar panels. This is 4 x 580w =2,320 W. Now, you must understand that you will hardly get a sustained 2,320w of solar yield. Always aim for 90 percent solar yield which is 0.9 x 2320w =2,088 W. Now you must consider inefficiencies when converting current and voltage to charge the batteries. Expensive inverters and solar charge controllers like those made by victron offer way higher conversion efficiency. But, most cheaper inverters we use offer poor efficiency. So let’s go with 85 percent conversion efficiency. We have 0.85 x 2088w=1,774.8 W. Since you battery is 51.2v, it will charge at average of 53v so we have, 1,774.8w / 53v = 33.4 amps.
Take note of the figure 33.4 amps. If you go with the 7.5kwh battery which is 150ah. It will take up to 150ah / 33.4amps = 4.5hrs sunlight to charge. Now notice if you go with the 20kwh battery which is 400ah it will take up to 400ah / 33.4amps = 12hrs sunlight to charge
This above is only accurate if you are not running a single day time load. Once you are running a load during the day eg your freezer is turned on. Then, your 1,774.8w from solar panel will need to power those loads first, before sending the balance to the battery, meaning you will be looking at 27amps or even just 25amps charging current.
Now, not all sunlight is equal. Just because it’s daytime doesn’t mean you will be generating such high sustained figures. For a fact, you can only expect such sustained performance all day only during the dry season in the south, except you are living up north in Nigeria.
We can therefore conclude that your solar panel is completely underpowered.
How to size your solar panels : I will give you my personal calculation that works for me always. If you are resident in the south of Nigeria, size your panels to fully charge your batteries with just 1.8hrs of sunlight i.e 1hr 48mins of sustained peak solar pv should charge your battery to full. If you are in the North use 2.5hrs of sunlight for your calculation.
This means that, to size your panels divide your total battery capacity by 1.8 if you live in the south and 2.5 if you live in the north. So 20kwh battery / 1.8 = 11,000w total panels and 7.5kwh battery / 1.8 = 4,160w total panels.
I can assure you, if you size your panels this way and factor in days of autonomy for battery size. Come rain come sun, out of 365 days a year, you will always get full charge for a minimum of 340 days. The remaining less than 25days which translates to 4 times a month in the rainy season, you can expect minimum of 50 percent charge.
Regarding questions 2 and 3. Do not buy from some alaba marketers, to be safe just go straight to their official distributors and buy from them. I have seen situations where they print new stickers with higher capacity and paste on their batteries to deceive unsuspecting customers. Do you research and ensure you purchase from the right source or you will not get value for your money. For the inverter part, you can maybe google search the name of the inverter and add words like ‘repair’ , ‘fault’ , ‘common issues’, ‘problems’ and see if you can find any known issues documented online. This is a neat trick for researching any electrical device you intend to buy.
*sorry for any typos, I didn’t proofread this.
The advantage of my properly sized ess. It has been raining since morning, however the rain has just stopped for an hour but you can see that in that 1 hour of less than ideal solar irradiation, the inverter has been able to store 100ah into the battery. Now, surely the rain will continue in the next hour or two, but between now and that time, I would have a full charge. This is despite 5 days straight of daily rainfall, I still get 100 percent charge within the very few windows of sunshine when the rain stops then continues. The other thing is to make sure you always use quality panels, you can see my jinko PV1 is producing 5,156w out of a rated 5,280w. PV2 is also producing similar and all these is with the heavy loads in the house turned on. 6 Likes |
Re: Solar Energy, A Complement To FTA by drizzle0007(m): 11:47am On Oct 08 |
justcallmenuel: 220Ah 12v super speed tubular battery available, #250,000. Call/whatsapp me on 08168986461 Do you offer warranty? |
Re: Solar Energy, A Complement To FTA by Drgreatone: 1:57pm On Oct 08 |
Dam5reey1: Ibadan
DIY Build Are the 2 batteries connected or u retiring the sako? |
Re: Solar Energy, A Complement To FTA by Obnoxious2001(m): 2:21pm On Oct 08 |
2 Likes |
Re: Solar Energy, A Complement To FTA by bassdow: 3:14pm On Oct 08 |
Ithream:
I was discouraged by the prices. Moreover there is light in my area to an extent. Instead I add on top the money go buy land in one area of Ogun state. I’m now a landlord instead of a solarlord. I support your mind set. Landed property to me is better investment. if you still single, and not a family man, you could get away with spending much less or focus on other more important things. At least you reason go that side. Not everyone does 1 Like |
Re: Solar Energy, A Complement To FTA by Dam5reey(m): 3:14pm On Oct 08 |
Drgreatone:
Are the 2 batteries connected or u retiring the sako? Both in parallel. |
Re: Solar Energy, A Complement To FTA by drizzle0007(m): 3:52pm On Oct 08 |
Good day everyone. Please I would like recommendations for a turbular battery of great quality. 220/12v preferable.
My budget is 250 and below. I would also appreciate recommendation for a 1100/12v inverter.
Please quote with your recommendations. Thank you so much |
Re: Solar Energy, A Complement To FTA by Drgreatone: 4:53pm On Oct 08 |
drizzle0007: Good day everyone. Please I would like recommendations for a turbular battery of great quality. 220/12v preferable.
My budget is 250 and below. I would also appreciate recommendation for a 1100/12v inverter.
Please quote with your recommendations. Thank you so much Curious, why do u still want a tubular battery with all you have read here sir? 1 Like |
Re: Solar Energy, A Complement To FTA by Drgreatone: 4:54pm On Oct 08 |
|
Re: Solar Energy, A Complement To FTA by HeavenlyBang(m): 5:11pm On Oct 08 |
drizzle0007: Good day everyone. Please I would like recommendations for a turbular battery of great quality. 220/12v preferable.
My budget is 250 and below. I would also appreciate recommendation for a 1100/12v inverter.
Please quote with your recommendations. Thank you so much Why tubular when you can get a Lifepo4 battery that's been tested to perform exactly as specced for just a little bit above that budget. 2 Likes |
Re: Solar Energy, A Complement To FTA by odimbannamdi(m): 5:13pm On Oct 08 |
Ithream:
I was discouraged by the prices. Moreover there is light in my area to an extent. Instead I add on top the money go buy land in one area of Ogun state. I’m now a landlord instead of a solarlord. ...this gave me a very good laugh now...lol... Now, let's get serious. The truth is, solar inverter is a necessary evil that inevitably awaits anybody that values his comforts, productivity and wants cost-savings. This because as long as you remain in this country, it is only a matter of time before the cycle of epileptic power supply either catches up with your area or they move your area to "Bandit A" and you will begin to wonder whether someone is putting hands into your pocket and zapping your resources through power bills. By then, you may then have to cough out x2 of your current budget to achieve what you could have achieve today. Personal story: Last October, it cost 450k to convert my SUV to use CNG at NIPCO station. The money sounded very big and I disapproved it further by saying fuel was just 400+/litre, so why spend 450k to convert my car. I was so foolish... Fast forward today, I spend nearly 200k every single month on fuel even though I drive sparingly. CNG conversion is now a whooping 950k, with serious shakara and lobbying. I am full of deep regrets for not doing it last year. By now, i would have finished bleeding off the 450k and recouped it through cost-savings At the end, it is ultimately your decision 13 Likes |
Re: Solar Energy, A Complement To FTA by Dam5reey1(m): 6:12pm On Oct 08 |
GloryJoyeux:
The advantage of my properly sized ess. It has been raining since morning, however the rain has just stopped for an hour but you can see that in that 1 hour of less than ideal solar irradiation, the inverter has been able to store 100ah into the battery. Now, surely the rain will continue in the next hour or two, but between now and that time, I would have a full charge. This is despite 5 days straight of daily rainfall, I still get 100 percent charge within the very few windows of sunshine when the rain stops then continues.
The other thing is to make sure you always use quality panels, you can see my jinko PV1 is producing 5,156w out of a rated 5,280w. PV2 is also producing similar and all these is with the heavy loads in the house turned on. Unfortunately these Junctek guys removed these robust information and left the basic information on the WiFi model |
Re: Solar Energy, A Complement To FTA by rhosymedre: 6:41pm On Oct 08 |
HeavenlyBang:
Lifepo4 batteries are built for different voltages, unlike tubular that's only in 12v. You have to be more specific than "2x200ah".
A 12v 200aH Lifepo4 battery is 2.56kwh A 24v 200aH is 5.12kwh A 48v 200aH is 10.24kwh I'm very grateful; I'm going to go and use this to study/research further before I commit with the installer. Thanks again. |
Re: Solar Energy, A Complement To FTA by rhosymedre: 6:49pm On Oct 08 |
GloryJoyeux:
Hello,
When sizing your system an energy consumption audit is one of the most crucial steps. I can see that you also listed the electrical loads you intend on carrying in a latter post. Although this is different from a comprehensive energy consumption audit, I will work with that figure.
Firstly, you must understand there is always a strong tendency to improve on a solar system after it has been installed so a lot of folks just go big from the get go if they are able to afford it.
A crucial question is: are you sure you really do not ever want to run that air conditioner? I’m asking because it seems like you really want it included, but the truth is, if you want it down the line, you will have to upgrade your system. Now, the ability to upgrade your system down the line is also a major advantage of residential ess, it means you can do what you can afford now and with time get to were you want it to be.
Answering your questions:
I will assumes you are comparing 48v batteries because using a 7.5kw inverter with anything less than 48v batteries system is poor design choice.
Battery size : Two paralleled 200ah battery is 51.2v x 400ah = 20kwh. That is over double the capacity of a single 7.5kwh battery. Both of these can power your air conditioner and other systems mentioned during the day with your 7.5kw inverter. However, at night, if you use the air conditioner with the 7.5kwh battery, you will quickly run out of stored energy. But the 20kwh battery will be more than enough to run your ‘inverter’ air conditioners over night.
By now I’m sure you are understanding the concept? Bigger batteries mean more energy stored for when there is no sunlight, it means longer run time of electrical load and means an extra day or two of autonomy.
Days of Autonomy : this is also a major factor when designing systems. In Nigeria right now we are at the raining season and this means poor solar yield. You therefore need to design a system that can go through at least a day of poor solar yield i.e. a full raining day where your batteries would just add 10 percent charge.
The larger 20kwh battery will enable you to plan 12kwh for the night, and the balance 8kwh for the next night incase there is poor solar yield due to rainfall.
The 7.5kwh battery means you will have to plan 4.5kwh for the night and 3kwh for the next night incase of poor solar yield.
Now, it all depends on energy consumption. Someone might be very okay on 7.5kwh inclusive of days of autonomy, while another will be okay with 20kwh, some have up to 90kwh as home ess.
Solar generation : I see you listed 4 units of 580w solar panels. This is 4 x 580w =2,320 W. Now, you must understand that you will hardly get a sustained 2,320w of solar yield. Always aim for 90 percent solar yield which is 0.9 x 2320w =2,088 W. Now you must consider inefficiencies when converting current and voltage to charge the batteries. Expensive inverters and solar charge controllers like those made by victron offer way higher conversion efficiency. But, most cheaper inverters we use offer poor efficiency. So let’s go with 85 percent conversion efficiency. We have 0.85 x 2088w=1,774.8 W. Since you battery is 51.2v, it will charge at average of 53v so we have, 1,774.8w / 53v = 33.4 amps.
Take note of the figure 33.4 amps. If you go with the 7.5kwh battery which is 150ah. It will take up to 150ah / 33.4amps = 4.5hrs sunlight to charge. Now notice if you go with the 20kwh battery which is 400ah it will take up to 400ah / 33.4amps = 12hrs sunlight to charge
This above is only accurate if you are not running a single day time load. Once you are running a load during the day eg your freezer is turned on. Then, your 1,774.8w from solar panel will need to power those loads first, before sending the balance to the battery, meaning you will be looking at 27amps or even just 25amps charging current.
Now, not all sunlight is equal. Just because it’s daytime doesn’t mean you will be generating such high sustained figures. For a fact, you can only expect such sustained performance all day only during the dry season in the south, except you are living up north in Nigeria.
We can therefore conclude that your solar panel is completely underpowered.
How to size your solar panels : I will give you my personal calculation that works for me always. If you are resident in the south of Nigeria, size your panels to fully charge your batteries with just 1.8hrs of sunlight i.e 1hr 48mins of sustained peak solar pv should charge your battery to full. If you are in the North use 2.5hrs of sunlight for your calculation.
This means that, to size your panels divide your total battery capacity by 1.8 if you live in the south and 2.5 if you live in the north. So 20kwh battery / 1.8 = 11,000w total panels and 7.5kwh battery / 1.8 = 4,160w total panels.
I can assure you, if you size your panels this way and factor in days of autonomy for battery size. Come rain come sun, out of 365 days a year, you will always get full charge for a minimum of 340 days. The remaining less than 25days which translates to 4 times a month in the rainy season, you can expect minimum of 50 percent charge.
Regarding questions 2 and 3. Do not buy from some alaba marketers, to be safe just go straight to their official distributors and buy from them. I have seen situations where they print new stickers with higher capacity and paste on their batteries to deceive unsuspecting customers. Do you research and ensure you purchase from the right source or you will not get value for your money. For the inverter part, you can maybe google search the name of the inverter and add words like ‘repair’ , ‘fault’ , ‘common issues’, ‘problems’ and see if you can find any known issues documented online. This is a neat trick for researching any electrical device you intend to buy.
*sorry for any typos, I didn’t proofread this.
Wow wow wow! I'm thoroughly and totally blown and I am truly and deeply very grateful The thing is that from what I have read here my understanding was that 2x200ah Lifepo4 (of the spec you've used i.e. 48v if I recall correctly) is a better option than a single 7.5v. I was therefore surprised when the installer suggested the single 7.5 over the two 2x200s. I am now going to calmly and carefully go through your incredible post for better understanding as part of my research ahead of choosing/agreeing the system. I am truly very very grateful once again .... but don't be surprised if I come up with more questions or seek further clarification in the next few days please. Thanks again. 2 Likes |
Re: Solar Energy, A Complement To FTA by rhosymedre: 6:59pm On Oct 08 |
bassdow:
Mentioning appliances such as Fridge or Freezer, or even Pumping machine, without mentioning their capacities means we either make guesses or give information that could end up being wrong.
We don't even know if your pumping machine is surface or submersible, let alone knowing it's capacity.
Even TV's power rating needs be stated as I have seen TVs that consume power like community cinema.
At end of the day, a larger battery bank would always server better than a smaller one irrespective of the number of units. In other words, 2pcs of 12v 200AH battery would always out perform 1pcs of 200AH battery all things being equal.
Now you probably are comparing 2 types of batteries => Lithium and Tubular/GEL/AGM batteries. Just understand that quality Lithium batteries gives much more power than Tubular/GEL/AGM of comparable capacity.
Note: I didn't just say Lithium battery is superior BUT I said Quality Lithium battery
Major advantage Lithium technology has over Tubular/GEL/AGM is, you could run Lithium batteries lower (though help if you don't) BUT for the likes of Tubular/GEL/AGM batteries, you need ensure you don't run beyond 50% of it's stated capacity else it wouldn't be there to serve you for long.
NB: A lot of us want to quickly respond to comments and get on our way. Abeg no give us reason to stress our brain unnecessarily. Consuming information such as "2pcs of 12v 200AH battery" is much quicker than saying "4.8kwh" BECAUSE we have to mentally do things such as convert 12-volts 200AH to kWh i.e; 200AH x 12v = 2,400 watts ÷ 1000 = 2.4 kWh
Anyway sha, the 2pcs of 200Ah batteries is much smaller and wouldn't last long in terms of years.. You would have better luck going with the 7.5kwh battery so long it ain't over-rated or low quality.
Once again, the above information could be wrong as capacity of the appliances especially the Fridge , Freezer , and Pumping machine weren't mentioned. Didn't even ask how long you intends powering them daily sef. Thanks sooo much; I'm truly grateful and will be studying this your post further as part of my research. Thanks once again. |
Re: Solar Energy, A Complement To FTA by Ithream: 7:06pm On Oct 08 |
odimbannamdi:
...this gave me a very good laugh now...lol...
Now, let's get serious.
The truth is, solar inverter is a necessary evil that inevitably awaits anybody that values his comforts, productivity and wants cost-savings.
This because as long as you remain in this country, it is only a matter of time before the cycle of epileptic power supply either catches up with your area or they move your area to "Bandit A" and you will begin to wonder whether someone is putting hands into your pocket and zapping your resources through power bills. By then, you may then have to cough out x2 of your current budget to achieve what you could have achieve today.
Personal story: Last October, it cost 450k to convert my SUV to use CNG at NIPCO station. The money sounded very big and I disapproved it further by saying fuel was just 400+/litre, so why spend 450k to convert my car. I was so foolish...
Fast forward today, I spend nearly 200k every single month on fuel even though I drive sparingly. CNG conversion is now a whooping 950k, with serious shakara and lobbying. I am full of deep regrets for not doing it last year. By now, i would have finished bleeding off the 450k and recouped it through cost-savings
At the end, it is ultimately your decision Very true. I totally agree. I can’t regret my decision cos my money is invested. I just hope I can raise another money to get an inverter system soonest b4 the prices gets worse off. Thanks for the advice though 🙏 2 Likes |
Re: Solar Energy, A Complement To FTA by rhosymedre: 8:42pm On Oct 08 |
rhosymedre:
Wow wow wow! I'm thoroughly and totally blown and I am truly and deeply very grateful
The thing is that from what I have read here my understanding was that 2x200ah Lifepo4 (of the spec you've used i.e. 48v if I recall correctly) is a better option than a single 7.5v. I was therefore surprised when the installer suggested the single 7.5 over the two 2x200s.
I am now going to calmly and carefully go through your incredible post for better understanding as part of my research ahead of choosing/agreeing the system. I am truly very very grateful once again .... but don't be surprised if I come up with more questions or seek further clarification in the next few days please.
Thanks again.
@GloryJoyeux (and at all) I've been carefully reading through that your great post and picking things and, like I said, with questions to follow. So my first question/s please: Assuming I stick to a 5KVA inverter, will a 24v system (instead of 48v) work and, if so, will a single 24v 200ah and 5.12kvh Lifepo4 battery work; and, assuming I want to use two 24v 200ah and 5.12kvh Lifepo4 batteries, will the system need to change to a 48 v system? Thanks again. |
Re: Solar Energy, A Complement To FTA by drizzle0007(m): 10:10pm On Oct 08 |
Drgreatone:
Curious, why do u still want a tubular battery with all you have read here sir? I sincerely believe it lasts longer. I have used a turbular battery and I could use it to work for more than 16 hours(2 work days) on a full charge. I don't think I can get that battery life with portable power I've read. |
Re: Solar Energy, A Complement To FTA by drizzle0007(m): 10:14pm On Oct 08 |
Drgreatone:
Curious, why do u still want a tubular battery with all you have read here sir? I haven't read much sir. I've used both a turbular battery and a portable power battery and the turbular battery last me x2 as more. I have a really small set up and I just want something that would be great. What do you recommend? |
Re: Solar Energy, A Complement To FTA by jonescosmos(m): 9:30am On Oct 09 |
I respect your decision to buy land first, It's very good but don't also forget that the cost materials to develop that land will not wait around the corner till you are ready to develop it. Same goes to Solar and its likes. Most of us who invested heavily in Solar have already became "Houses Lords" and we thought going solar should be a means of mitigating recurrent subscription based energy expenses. One thing you should do is try to balance the savings, while you are trying to save to buy/build a house why not go solar now so that the money you would have used to pay for energy expenses will be diverted into the saving for the property of your dream. Ithream:
I was discouraged by the prices. Moreover there is light in my area to an extent. Instead I add on top the money go buy land in one area of Ogun state. I’m now a landlord instead of a solarlord. 2 Likes |
Re: Solar Energy, A Complement To FTA by kiekie1(m): 9:55am On Oct 09 |
UP FOR SALE!
Victron bluesolar 12-48v 70a MPPT
Condition: Fairly used but functional . "LCD might need replacement"
Firm price: 180k
Location: Lagos but can be waybilled under buyers expense.
O8O35O31951 |
Re: Solar Energy, A Complement To FTA by bassdow: 11:07am On Oct 09 |
jonescosmos: I respect your decision to buy land first, It's very good but don't also forget that the cost materials to develop that land will not wait around the corner till you are ready to develop it. Same goes to Solar and its likes.
Most of us who invested heavily in Solar have already became "Houses Lords" and we thought going solar should be a means of mitigating recurrent subscription based energy expenses.
One thing you should do is try to balance the savings, while you are trying to save to buy/build a house why not go solar now so that the money you would have used to pay for energy expenses will be diverted into the saving for the property of your dream.
Land is an Asset, Solar is a liability, except of course it powers your business. Land appreciates, Solar doesn't. Now even if all He's got is the 400,000 naira and he uses it to buy land, and does foundation on it as form of security to avoid Omo`Onile wahala. He could always sell the land above what he initially paid later. Same can't be said of Solar. Now you might want to say not everyOne has got money to do foundation at this time BUT I tell you, for as low as 50,000 , you can do something very basic just to secure it. Omo`Onile would look elsewhere the moment they see as little as 4 coaches on it. Just be smart to do on both sides so they don't cut your 1-plot into 2. There's this client of mine I met here on nairaland. I kept suggesting to this man to go solar but Oga no gree. As at then, a brand new quality solar panel sells for around 46,000 naira to 50,000 naira. My first epEver 40Amp MPPT charge controller then sells for about 70,000 naira. Na early last year he finally went solar and the money He spent, me sef pity am. The cost of batteries alone would have done a lot. But I doubt he has any regrets probably because He had his priorities then and now was time for such. if not for nature of my job + my mini Server farm, I wouldn't run solar at the scale I currently do. We don't know the young man's current state hence reason I applauded his resolve. Me ma sef no fit drive car of 500,000 naira when I live in a face-me-I-face-You apartment. Except of course that Car dey generate money for me. In our previous compound, a man who lives in self-contained apartment, has 2 flashy cars but the landlord wey dey live for 3 or 4 bedroom apartment no get keke. The man works at Ladipo hence mostly drives those Cars on weekends. I met them in that compound, and I left them in same compound. I was the first to go Solar in that street then, but before I left, I helped a few that I was able to convince go Solar. A lot of them who didn't come onboard could afford it hence money wasn't an issue. Another issue most people have with Solar is the high initial cost of acquisition. They see it as expensive hence prefers Petrol based generator. Guess most need to live in a Solar powered apartment for just a week to understand what they're missing BUT then again, if your pocket never FAT, you don't deserve such comfort as it could make you remain poor. hopefully, said young man ain't using expensive phones else all these talk of buying land, instead of buying Solar becomes counter productive. Some people's phone costs upwards 200,000 naira YET they earn less than 100,000 naira a month, and lives in rented apartment. What I would suggest he does, if not in a hurry, is to be on look out for bargain sales and take opportunity. BUT this person we dey call Young man, fit be Big person Ooo who just ain't ready (or seen reason) for such expenses 4 Likes |
Re: Solar Energy, A Complement To FTA by bassdow: 11:11am On Oct 09 |
kiekie1: UP FOR SALE!
Victron bluesolar 12-48v 70a MPPT
Condition: Fairly used but functional . "LCD might need replacement"
Firm price: 180k
Location: Lagos but can be waybilled under buyers expense.
O8O35O31951 This actually is among top recognized brands when you talk about charge Controllers wey sabi dem work. 1 Like |
Re: Solar Energy, A Complement To FTA by bassdow: 11:12am On Oct 09 |
drizzle0007:
I haven't read much sir. I've used both a turbular battery and a portable power battery and the turbular battery last me x2 as more.
I have a really small set up and I just want something that would be great. What do you recommend? what do you mean by "portable power battery" ? |